Assumed:
- 33 °C - ambient temperature (T hot), from the experiment with tap water cooling;
- Infinite - the cooling power at T hot;
- Use only the Adaptive 2-stage Peltier module (190 Couples, 16.2W 2.8A 15.7V, 30x30mm).
Stage | Qc, W | Tc, °C | Th, °C | ΔT, °C | Modules | I, A | P, W |
---|---|---|---|---|---|---|---|
1 | 4.3 | -60 | -20.35 | 39.65 | 1 | 2.1 | 18.23 |
2 | 22.52 | -20.35 | 33 | 53.35 | 4 | 2.1 | 100.67 |
- Qc/module, W: 0.86
- P total, W: 118.9
Stage | Qc, W | Tc, °C | Th, °C | ΔT, °C | Modules | I, A | P, W |
---|---|---|---|---|---|---|---|
1 | 2.43 | -60 | -22.61 | 37.39 | 1 | 1.4 | 8.05 |
2 | 10.48 | -22.61 | 33 | 55.62 | 2 | 2.1 | 50.49 |
- Qc/module, W: 0.81
- P total, W: 58.53
Stage | Qc, W | Tc, °C | Th, °C | ΔT, °C | Modules | I, A | P, W |
---|---|---|---|---|---|---|---|
1 | 1.13 | -60 | -34.98 | 25.02 | 1 | 0.7 | 1.97 |
2 | 3.1 | -34.98 | 33.01 | 67.99 | 1 | 2.1 | 25.66 |
- Qc/module, W: 0.57
- P total, W: 27.63