smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.19.0-15-generic] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron RealSSD C300/M500
Device Model: Crucial_CT240M500SSD3
Serial Number: 1351095F8F0D
LU WWN Device Id: 5 00a075 1095f8f0d
Firmware Version: MU03
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: < 1.8 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is: Fri Jul 10 22:23:52 2015 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 16) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 1115) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 18) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 0
5 Reallocated_Sector_Ct 0x0033 100 100 000 Pre-fail Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 5580
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 822
171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0
172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0
173 Wear_Leveling_Count 0x0032 099 099 000 Old_age Always - 40
174 Unexpect_Power_Loss_Ct 0x0032 100 100 000 Old_age Always - 332
180 Unused_Rsvd_Blk_Cnt_Tot 0x0033 000 000 000 Pre-fail Always - 4066
183 SATA_Iface_Downshift 0x0032 100 100 000 Old_age Always - 1
184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 043 019 000 Old_age Always - 57 (Min/Max 0/81)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 16
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0
202 Percent_Lifetime_Used 0x0031 099 099 000 Pre-fail Offline - 1
206 Write_Error_Rate 0x000e 100 100 000 Old_age Always - 0
210 Success_RAIN_Recov_Cnt 0x0032 100 100 000 Old_age Always - 0
246 Total_Host_Sector_Write 0x0032 100 100 --- Old_age Always - 6370807274
247 Host_Program_Page_Count 0x0032 100 100 --- Old_age Always - 204622467
248 Bckgnd_Program_Page_Cnt 0x0032 100 100 --- Old_age Always - 449884032
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Self-test routine in progress 90% 5579 -
# 2 Vendor (0xff) Completed without error 00% 5576 -
# 3 Vendor (0xff) Completed without error 00% 5573 -
# 4 Vendor (0xff) Completed without error 00% 5571 -
# 5 Vendor (0xff) Completed without error 00% 5569 -
# 6 Vendor (0xff) Completed without error 00% 5569 -
# 7 Vendor (0xff) Completed without error 00% 5568 -
# 8 Vendor (0xff) Completed without error 00% 5567 -
# 9 Vendor (0xff) Completed without error 00% 4722 -
#10 Vendor (0xff) Completed without error 00% 5567 -
#11 Vendor (0xff) Completed without error 00% 5566 -
#12 Vendor (0xff) Completed without error 00% 5565 -
#13 Vendor (0xff) Completed without error 00% 5546 -
#14 Vendor (0xff) Completed without error 00% 5539 -
#15 Vendor (0xff) Completed without error 00% 5531 -
#16 Vendor (0xff) Completed without error 00% 5528 -
#17 Vendor (0xff) Completed without error 00% 5527 -
#18 Vendor (0xff) Completed without error 00% 5523 -
#19 Vendor (0xff) Completed without error 00% 5513 -
#20 Vendor (0xff) Completed without error 00% 5508 -
#21 Vendor (0xff) Completed without error 00% 5499 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.