Tasmota Smart Meter Interface: eBZ DD3 2R06 DTA SMZ1
>D
>B
TelePeriod 60
=>sensor53 r
>M 1
; Device: eBZ DD3 2R06 DTA SMZ1
; protocol is D0 SML HEX
; 9600@7E1 for OP-type devices, 9600@8N1 for SM-type devices
+1,3,s,0,9600,SML,1
; Zählerstand zu +A, tariflos,
; Zählerstände Auflösung 10 µW*h (6 Vorkomma- und 8 Nachkommastellen)
1,77070100010800FF@100000000,Energie Bezug,kWh,1_8_0,8
; Zählerstand zu +A, Tarif 1
1,77070100010801FF@100000000,Energie Bezug T1,kWh,1_8_1,8
; Zählerstand zu +A, Tarif 2
1,77070100010802FF@100000000,Energie Bezug T2,kWh,1_8_2,8
; Zählerstand zu -A, tariflos
1,77070100020800FF@100000000,Energie Export,kWh,2_8_0,8
; Summe der Momentan-Leistungen in allen Phasen, Auflösung 0,01W (5 Vorkomma- und 2 Nachkommastellen)
1,77070100100700FF@1,Leistung,W,16_7_0,16
; Momentane Leistung in Phase Lx, Auflösung 0,01W (5 Vorkomma- und 2 Nachkommastellen)
1,77070100240700FF@1,Leistung L1,W,36_7_0,16
1,77070100380700FF@1,Leistung L2,W,56_7_0,16
1,770701004C0700FF@1,Leistung L3,W,76_7_0,16
; Spannung in Phase Lx, Auflösung 0,1V (nur über MSB)
;1,77070100200700FF@1,Spannung L1,V,32_70,1
;1,77070100340700FF@1,Spannung L2,V,52_7_0,1
;1,77070100480700FF@1,Spannung L3,V,72_7_0,1
; Statuswort, 4 Byte Information über den Betriebszustand, HEX string
; tasmota can decode one string per device only!
;1,1-0:96.5.0*255@#),Status1,,96_5_0,0
;1,1-0:96.8.0*255@#),Status2,,96_8_0,0
; Geräte-Identifikation, Nach DIN 43863-5
1,77070100000009FF@#),Identifikation,,96_1_0,0
;1,77070100000000FF@#),Identifikation,,0_0_0,0
#