Created
August 26, 2024 21:30
-
-
Save gerco/91e27d2b75a77ce0b055be569619bf97 to your computer and use it in GitHub Desktop.
SolarEdge inverter modbus Home Assistant config
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
modbus: | |
- name: solaredge | |
type: tcp | |
host: 10.1.7.109 | |
port: 1502 | |
sensors: | |
- name: SolarEdge Inverter Status | |
device_address: 1 | |
address: 40107 | |
- name: SolarEdge Inverter AC Energy Generated | |
device_address: 1 | |
address: 40093 | |
data_type: uint32 | |
- name: SolarEdge Inverter AC Energy Scale Factor | |
device_address: 1 | |
address: 40095 | |
data_type: uint16 | |
- name: SolarEdge Inverter AC Power Generated | |
device_address: 1 | |
address: 40083 | |
data_type: int16 | |
- name: SolarEdge Inverter AC Power Scale Factor | |
device_address: 1 | |
address: 40084 | |
data_type: int16 | |
- name: SolarEdge Inverter M2 AC Power | |
device_address: 1 | |
address: 40380 | |
data_type: int16 | |
- name: SolarEdge Inverter M2 AC Power Scale Factor | |
device_address: 1 | |
address: 40384 | |
- name: SolarEdge Inverter M2 Exported Energy | |
device_address: 1 | |
address: 40400 | |
data_type: uint32 | |
- name: SolarEdge Inverter M2 Imported Energy | |
device_address: 1 | |
address: 40408 | |
data_type: uint32 | |
- name: SolarEdge Inverter M2 Energy Scale Factor | |
device_address: 1 | |
address: 40416 | |
data_type: int16 | |
Sign up for free