You can use ssacli
(smart storage administrator command line interface) tool to manage any of supported HP Smart Array Controllers in your Proxmox host without need to reboot your server to access Smart Storage Administrator in BIOS. That means no host downtime when managing your storage.
CLI is not as convenient as GUI interface provided by BIOS or desktop utilities, but still allows you to fully manage your controller, physical disks and logical drives on the fly with no Proxmox host downtime.
ssacli
replaces older hpssacli
, but shares the same syntax and adds support for newer servers and controllers.
Installation process of the ssacli
package on Proxmox is the same as on any other Debian based system.
NOTE: HP does not provide Buster repository for Debian 10/Proxmox 6.x, but we can still use Stretch repository even that it's targeted for Debian 9/Proxmox 5.x.
To add HP's MCP repository to apt
sources list use this command:
echo "deb http://downloads.linux.hpe.com/SDR/repo/mcp stretch/current non-free" > /etc/apt/sources.list.d/hp-mcp.list
Public keys are needed by apt
to verify repository signatures, so we need to download and add them. There are four of them and we need to download and them all:
wget -q -O - http://downloads.linux.hpe.com/SDR/hpPublicKey1024.pub | apt-key add -
wget -q -O - http://downloads.linux.hpe.com/SDR/hpPublicKey2048.pub | apt-key add -
wget -q -O - http://downloads.linux.hpe.com/SDR/hpPublicKey2048_key1.pub | apt-key add -
wget -q -O - http://downloads.linux.hpe.com/SDR/hpePublicKey2048_key1.pub | apt-key add -
First, we need to update available packages:
apt update
And then we can install the ssacli
package:
apt install ssacli
Command short and long names
All commands have a short name to reduce the length of the total input provided to the ssacli
tool. You can use short or long name. Here is a list of all commands and their long and short names:
- chassisname = ch
- controller = ctrl
- logicaldrive = ld
- physicaldrive = pd
- drivewritecache = dwc
- licensekey = lk
You can specify disks also as:
- A range of drives (bay 1 to 3): 1I:1:1-1I:1:3
- Drives that are unassigned: allunassigned
Here are few examples of ssacli
commands that you can use to diagnose and manage your HP Smart Storage Controller.
Show available controllers
ssacli ctrl all show
Show controllers status
ssacli ctrl all show status
Show detailed controllers information
ssacli ctrl all show detail
Show controllers configuration
ssacli ctrl all show config
Rescan for new devices Useful after swapping disks in bays, etc...
ssacli rescan
Show all physical disks (or their status) (controller slot 0)
ssacli ctrl slot=0 pd all show
ssacli ctrl slot=0 pd all show status
Show all physical disks detailed information (controller slot 0)
ssacli ctrl slot=0 pd all show detail
Show logical drives (or their status) (controller slot 0, all or specific logical drive(s))
ssacli ctrl slot=0 ld all show
ssacli ctrl slot=0 ld all show status
ssacli ctrl slot=0 ld 1 show
ssacli ctrl slot=0 ld 1 show status
Show detailed logical drives information (controller slot 0, all or specific logical drive(s))
ssacli ctrl slot=0 ld all show detail
ssacli ctrl slot=0 ld 1 show detail
Show array information (controller slot 0, array A)
ssacli ctrl slot=0 array a show
Show array status (controller slot 0, all arrays)
ssacli ctrl slot=0 array all show status
Create new RAID 0 logical drive (controller slot 0, disk in port 1I:box 1:bay 1)
ssacli ctrl slot=0 create type=ld drives=1I:1:1 raid=0
Create new RAID 1 logical drive (controller slot 0, disks in port 1I:box 1:bay 1 and 2)
ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
Create new RAID 5 logical drive (controller slot 0, diks in port 1I:box 1:bay 1 to 4)
ssacli ctrl slot=0 create type=ld drives=1I:1:1-1I:1:4 raid=5
Delete logical drive (controller slot 0, logical drive 1)
ssacli ctrl slot=0 ld 1 delete
Add new physical disks to logical drive (controller slot 0, logical drive 1, disks in port 1I:box 1:bay 6 and 7)
ssacli ctrl slot=0 ld 2 add drives=1I:1:6,1I:1:7
Add spare disks (controller slot 0, logical drive 1, array A, disks in port 1I:box 1:bay 6 and 7)
ssacli ctrl slot=0 array a add spares=1I:1:6,1I:1:7
Add global spare disks (controller slot 0, logical drive 1, all arrays, disks in port 1I:box 1:bay 6 and 7)
ssacli ctrl slot=0 array all add spares=1I:1:6,1I:1:7
Turn on/off blink logical drive LED (controller slot 0, logical drive 1)
ssacli ctrl slot=0 ld 1 modify led=on
ssacli ctrl slot=0 ld 1 modify led=off
Turn on/off blink physical disk LED (controller slot 0, physical disk port 1I:box 1:bay 1)
ssacli ctrl slot=0 pd 1I:1:1 modify led=on
ssacli ctrl slot=0 pd 1I:1:1 modify led=off
Modify smart array cache read and write ratio (controller slot 0, cacheratio 80% read/20% write)
ssacli ctrl slot=0 modify cacheratio=80/20
Show physical drive write cache status (controller slot 0)
ssacli ctrl slot=0 modify dwc=?
Enable/disable physical drive write cache (controller slot 0) Important: Because physical drive write cache is not battery-backed, you could lose data if a power failure occurs during a write process. To minimize this possibility, use a backup power supply.
ssacli ctrl slot=0 modify dwc=enable
ssacli ctrl slot=0 modify dwc=disable
Show status of smart array write cache when no battery is present (no-battery write cache option, controller slot 0)
ssacli ctrl slot=0 modify nbwc=?
Enable/disable smart array write cache when no battery is present (no-battery write cache option, controller slot 0)
ssacli ctrl slot=0 modify nbwc=enable
ssacli ctrl slot=0 modify nbwc=disable
Enable/disable smart array cache for certain Logical Volume (controller slot 0, logical drive 1)
ssacli ctrl slot=0 ld 1 modify arrayaccelerator=enable
ssacli ctrl slot=0 ld 1 modify arrayaccelerator=disable
Enable/disable SSD Smart Path (controller slot 0, array A)
ssacli ctrl slot=0 array a modify ssdsmartpath=enable
ssacli ctrl slot=0 array a modify ssdsmartpath=disable
Show spare activation mode
ssacli ctrl slot=0 modify spareactivationmode=?
Set spare activation mode
ssacli ctrl slot=0 modify spareactivationmode=predictive
ssacli ctrl slot=0 modify spareactivationmode=failure
Show rebuild priority
ssacli ctrl slot=0 modify rp=?
Modify rebuild priority
ssacli ctrl slot=0 modify rp=low
ssacli ctrl slot=0 modify rp=medium
ssacli ctrl slot=0 modify rp=mediumhigh
ssacli ctrl slot=0 modify rp=high
Erase Physical Drive (controller slot 0, physical disk port 1I:box 1:bay 1)
ssacli ctrl slot=0 pd 1I:1:1 modify erase
You need to create 4 separate logical drives, each with one physical drive. You can do this either from CLI or using ORCA utility on Boot.
CLI:
First make sure that physical drives that you will use are not assigned to any logical drives, then this might work:
ssacli ctrl slot=0 create type=ld drives=1I:1:1 raid=0
ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
ssacli ctrl slot=0 create type=ld drives=2I:1:5 raid=0
ssacli ctrl slot=0 create type=ld drives=2I:1:6 raid=0
ORCA:
F6 if I remember correctly, but check with your BIOS, it was quite a hassle for me to find the right key & moment to access ORCA but it as far as I know every HP Smart Array should make it possible to configure from ORCA. But once you are in, it is even easier than from CLI, so I recommend to take this route.
Good luck :)