Save AMajland/6ffc6814df2a92e99cff2c901447efee to your computer and use it in GitHub Desktop.
# Automations.yaml | |
alias: PV to EV Dynamic | |
trigger: | |
- platform: time_pattern | |
seconds: /20 | |
condition: [] | |
action: | |
- choose: | |
- conditions: | |
- condition: state | |
entity_id: input_select.ev_test_charge | |
state: Solar 3 Phase | |
sequence: | |
- service: easee.set_circuit_dynamic_limit | |
data: | |
charger_id: CHARGERID | |
currentP1: >- | |
{% set min_voltage = | |
min(states('sensor.ams_cf58_u1'),states('sensor.ams_cf58_u2'),states('sensor.ams_cf58_u3')) | |
%} {% set current = ( ((states('sensor.pv_to_ev_power') | float) | |
) / (min_voltage | float ) / 3.0 + 0.5) %} {%if current < 6.0 | |
%}{% set current = 6.0 %} {% endif %} {{ current }} | |
currentP2: >- | |
{% set min_voltage = | |
min(states('sensor.ams_cf58_u1'),states('sensor.ams_cf58_u2'),states('sensor.ams_cf58_u3')) | |
%} {% set current = ( ((states('sensor.pv_to_ev_power') | float) | |
) / (min_voltage | float ) / 3.0 + 0.5) %} {%if current < 6.0 | |
%}{% set current = 6.0 %} {% endif %} {{ current }} | |
currentP3: >- | |
{% set min_voltage = | |
min(states('sensor.ams_cf58_u1'),states('sensor.ams_cf58_u2'),states('sensor.ams_cf58_u3')) | |
%} {% set current = ( ((states('sensor.pv_to_ev_power') | float) | |
) / (min_voltage | float ) / 3.0 + 0.5) %} {%if current < 6.0 | |
%}{% set current = 6.0 %} {% endif %} {{ current }} | |
time_to_live: "1" | |
- conditions: | |
- condition: state | |
entity_id: input_select.ev_test_charge | |
state: Solar 1 Phase | |
sequence: | |
- service: easee.set_circuit_dynamic_limit | |
data: | |
charger_id: CHARGERID | |
currentP1: >- | |
{% set current = ( ((states('sensor.pv_to_ev_power') | float) ) / (states('sensor.ams_cf58_u1') | float) ) + 1.4 %} | |
{%if current > 16.0 %}{% set current = 16.0 %} | |
{% endif %} | |
{{ current }} | |
currentP2: "0" | |
currentP3: "0" | |
time_to_live: "1" | |
mode: single | |
alias: PV to EV Phases | |
description: >- | |
Change 1 to 3 phases - check every 1 min. 10min min for 10min to change to 3. | |
Avererage below for 10min to go back | |
trigger: | |
- platform: time_pattern | |
minutes: /1 | |
condition: | |
- condition: not | |
conditions: | |
- condition: template | |
value_template: "{{ states('sensor.CHARGERID_status') == 'disconnected' }}" | |
action: | |
- choose: | |
- conditions: | |
- condition: state | |
entity_id: input_select.ev_test_charge | |
state: Scheduled | |
sequence: | |
- service: easee.set_circuit_dynamic_limit | |
data: | |
charger_id: CHARGERID | |
currentP1: "32" | |
currentP2: "32" | |
currentP3: "32" | |
time_to_live: "15" | |
- conditions: | |
- condition: state | |
entity_id: input_select.ev_test_charge | |
state: Solar 1 Phase | |
for: | |
hours: 0 | |
minutes: 10 | |
seconds: 0 | |
- condition: numeric_state | |
entity_id: sensor.pv_to_ev_power_10m_min | |
above: 3680 | |
sequence: | |
- service: input_select.select_option | |
target: | |
entity_id: input_select.ev_test_charge | |
data: | |
option: Solar 3 Phase | |
- conditions: | |
- condition: state | |
entity_id: input_select.ev_test_charge | |
state: Solar 3 Phase | |
for: | |
hours: 0 | |
minutes: 10 | |
seconds: 0 | |
- condition: numeric_state | |
entity_id: sensor.pv_to_ev_power_10_min_avg | |
below: 3680 | |
sequence: | |
- service: input_select.select_option | |
target: | |
entity_id: input_select.ev_test_charge | |
data: | |
option: Solar 1 Phase | |
mode: single | |
#configuration.yaml | |
sensor: | |
- platform: statistics | |
name: PV to EV Power (10m min) | |
unique_id: sensor.pv_to_ev_power_10m_min | |
entity_id: sensor.pv_to_ev_power | |
state_characteristic: value_min | |
max_age: | |
minutes: 10 | |
- platform: statistics | |
name: PV to EV Power (10 min avg) | |
unique_id: sensor.pv_to_ev_power_10m_avg | |
entity_id: sensor.pv_to_ev_power | |
state_characteristic: average_linear | |
max_age: | |
minutes: 10 | |
- platform: statistics | |
name: PV to EV Power (2 min avg) | |
unique_id: sensor.pv_to_ev_power_2m_avg | |
entity_id: sensor.pv_to_ev_power | |
state_characteristic: average_linear | |
max_age: | |
minutes: 2 | |
- platform: statistics | |
name: N1 Meter Power Netto (10 min avg) | |
unique_id: sensor.n1_meter_power_netto_avg | |
entity_id: sensor.n1_meter_power_netto | |
state_characteristic: average_linear | |
max_age: | |
minutes: 10 | |
template: | |
- sensor: | |
- name: "PV to EV Power" | |
unique_id: sensor.pv_to_ev_power | |
unit_of_measurement: W | |
device_class: power | |
state: > | |
{% set surplus = (0.001 + ((states("sensor.CHARGERID_power") | float(0)) - (states("sensor.n1_meter_power_netto") | float(0))) | round(0) ) %} | |
{% if surplus < 0.0 %}{% set surplus = 0.0 %} | |
{% endif %} | |
{{ surplus }} | |
See above from line 150. That is just a helper to calculate available power.
It looks at currente charge rate and the export and a bit of rounding.
If you are charging with 6kW and exporting 4kW you have 10kW available for charging.
The reason i've done it that way is that it was easy to add statistics sensors that looks at 2 and 10 min averages as welle as minimum.
I use those to decide when its time to change between 1 and 3 phase charging. In the above i will first change to 3 fase when the minum surplus has been over 3680W for 10 minutes. The other way it will first drop down to 1 phase again when the average has been below 3680W for 10minutes.
So on a day with many clous the min drop often and it will stay on one phase charging..
On a good sunny day it will stay on 3 phase even troug i use a lot of power for a short while for i.e a cup of coffe (if its get below 6A it will pause for a while)
what sensor is this: sensor.pv_to_ev_power