A snippet of the basic additional sensors configuration needed to track Panel production, on a SolarEdge single inverter, single battery system, along with the configuration used on the Power Flow Plus card.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
template: | |
- sensor: | |
- name: "Solar Panel Production W" | |
unique_id: solar_panel_production_w | |
unit_of_measurement: "W" | |
icon: mdi:solar-power | |
state: > | |
{% set i1_dc_power = states('sensor.solaredge_i1_dc_power') | float(0) %} | |
{% set b1_dc_power = states('sensor.solaredge_b1_dc_power') | float(0) %} | |
{% if (i1_dc_power + b1_dc_power <= 0) %} | |
0 | |
{% else %} | |
{{ (i1_dc_power + b1_dc_power) }} | |
{% endif %} | |
availability: > | |
{{ states('sensor.solaredge_i1_dc_power') | is_number and states('sensor.solaredge_b1_dc_power') | is_number }} | |
- name: "Solar House Consumption W" | |
unique_id: solar_house_consumption_w | |
unit_of_measurement: "W" | |
icon: mdi:home | |
state: > | |
{% set i1_ac_power = states('sensor.solaredge_i1_ac_power') | float(0) %} | |
{% set m1_ac_power = states('sensor.solaredge_m1_ac_power') | float(0) %} | |
{% if (i1_ac_power - m1_ac_power <= 0) %} | |
0 | |
{% else %} | |
{{ (i1_ac_power - m1_ac_power) }} | |
{% endif %} | |
availability: > | |
{{ states('sensor.solaredge_i1_ac_power') | is_number and states('sensor.solaredge_m1_ac_power') | is_number }} | |
- name: Solar Inverter Consumption w | |
unique_id: solar_inverter_consumption_w | |
unit_of_measurement: "W" | |
icon: mdi:mdi:home-lightning-bolt-outline | |
state: > | |
{% set i1_ac_power = states('sensor.solaredge_i1_ac_power') | float(0) %} | |
{% set i1_dc_power = states('sensor.solaredge_i1_dc_power') | float(0) %} | |
{% if (i1_ac_power > i1_dc_power < 0) %} | |
{{ (i1_ac_power - i1_dc_power)| round(2) }} | |
{% else %} | |
{{ ( i1_dc_power - i1_ac_power)| round(2)}} | |
{% endif %} | |
availability: > | |
{{ states('sensor.solaredge_i1_ac_power') | is_number and states('sensor.solaredge_i1_dc_power') | is_number }} | |
- name: "Solar Imported Power W" | |
unique_id: solar_imported_power_w | |
unit_of_measurement: "W" | |
icon: mdi:transmission-tower-export | |
state: > | |
{% set m1_ac_power = states('sensor.solaredge_m1_ac_power') | float(0) %} | |
{% if (m1_ac_power < 0) %} | |
{{ (m1_ac_power * -1) }} | |
{% else %} | |
0 | |
{% endif %} | |
availability: > | |
{{ states('sensor.solaredge_m1_ac_power') | is_number}} | |
- name: "Solar Exported Power W" | |
unique_id: solar_exported_power_w | |
unit_of_measurement: "W" | |
icon: mdi:transmission-tower-import | |
state: > | |
{% set m1_ac_power = states('sensor.solaredge_m1_ac_power') | float(0) %} | |
{% if (m1_ac_power > 0) %} | |
{{ (m1_ac_power) }} | |
{% else %} | |
0 | |
{% endif %} | |
availability: > | |
{{ states('sensor.solaredge_m1_ac_power') | is_number }} | |
sensor: | |
- platform: integration | |
source: sensor.solar_panel_production_w | |
method: left | |
unit_prefix: k | |
name: solar_panel_production_kwh | |
- platform: integration | |
source: sensor.solar_house_consumption_w | |
method: left | |
unit_prefix: k | |
name: solar_house_consumption_kwh | |
- platform: integration | |
source: sensor.solar_imported_power_w | |
method: left | |
unit_prefix: k | |
name: solar_imported_power_kwh | |
- platform: integration | |
source: sensor.solar_exported_power_w | |
method: left | |
unit_prefix: k | |
name: solar_exported_power_kwh | |
utility_meter: | |
solar_panel_production_daily: | |
source: sensor.solar_panel_production_kwh | |
name: Solar Panel Production Daily | |
cycle: daily | |
solar_house_consumption_daily: | |
source: sensor.solar_house_consumption_kwh | |
name: Solar House Consumption Daily | |
cycle: daily | |
solar_imported_power_daily: | |
source: sensor.solar_imported_power_kwh | |
name: Solar Imported Power Daily | |
cycle: daily | |
solar_exported_power_daily: | |
source: sensor.solar_exported_power_kwh | |
name: Solar Exported Power Daily | |
cycle: daily | |
solar_imported_power_weekly: | |
source: sensor.solar_imported_power_kwh | |
name: Solar Imported Power Weekly | |
cycle: weekly | |
solar_house_consumption_weekly: | |
source: sensor.solar_house_consumption_kwh | |
name: Solar House Consumption Weekly | |
cycle: weekly | |
solar_panel_production_weekly: | |
source: sensor.solar_panel_production_kwh | |
name: Solar Panel Production Weekly | |
cycle: weekly | |
solar_exported_power_weekly: | |
source: sensor.solar_exported_power_kwh | |
name: Solar Exported Power Weekly | |
cycle: weekly | |
solar_imported_power_monthly: | |
source: sensor.solar_imported_power_kwh | |
name: Solar Imported Power Monthly | |
cycle: monthly | |
solar_house_consumption_monthly: | |
source: sensor.solar_house_consumption_kwh | |
name: Solar House Consumption Monthly | |
cycle: monthly | |
solar_panel_production_monthly: | |
source: sensor.solar_panel_production_kwh | |
name: Solar Panel Production Monthly | |
cycle: monthly | |
solar_exported_power_monthly: | |
source: sensor.solar_exported_power_kwh | |
name: Solar Exported Power Monthly | |
cycle: monthly | |
solar_imported_power_yearly: | |
source: sensor.solar_imported_power_kwh | |
name: Solar Imported Power Yearly | |
cycle: yearly | |
solar_house_consumption_yearly: | |
source: sensor.solar_house_consumption_kwh | |
name: Solar House Consumption Yearly | |
cycle: yearly | |
solar_panel_production_yearly: | |
source: sensor.solar_panel_production_kwh | |
name: Solar Panel Production Yearly | |
cycle: yearly | |
solar_exported_power_yearly: | |
source: sensor.solar_exported_power_kwh | |
name: Solar Exported Power Yearly | |
cycle: yearly |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
type: custom:power-flow-card-plus | |
title: Power Flow | |
entities: | |
home: | |
entity: sensor.solar_house_consumption_w | |
color_icon: solar | |
color_value: true | |
fossil_fuel_percentage: | |
entity: sensor.grid_fossil_fuel_percentage | |
icon: mdi:pine-tree | |
color_icon: true | |
display_zero: false | |
name: Green Import | |
state_type: power | |
color_value: true | |
grid: | |
name: Grid | |
entity: sensor.solaredge_m1_ac_power | |
display_state: one_way | |
color_circle: true | |
invert_state: true | |
solar: | |
icon: mdi:solar-panel-large | |
entity: sensor.solar_panel_production_w | |
color_value: true | |
color_icon: true | |
battery: | |
name: Battery | |
entity: sensor.solaredge_b1_dc_power | |
display_state: one_way | |
color_icon: true | |
color_circle: true | |
invert_state: true | |
state_of_charge: sensor.solaredge_b1_state_of_energy | |
color_state_of_charge_value: true | |
clickable_entities: true | |
display_zero_lines: | |
mode: hide | |
transparency: 50 | |
grey_color: | |
- 189 | |
- 189 | |
- 189 | |
use_new_flow_rate_model: true | |
w_decimals: 0 | |
kw_decimals: 1 | |
min_flow_rate: 0.75 | |
max_flow_rate: 6 | |
max_expected_power: 6000 | |
min_expected_power: 0.01 | |
watt_threshold: 750 | |
dashboard_link: /energy | |
dashboard_link_label: Energy Summary |
I've settled on using the SolarEdge cloud integration for energy, as i can handle the 15 min delay (for billing and historical use) and they can do the heavy lifting of sampling and calculating energy flows.
I am using the Modbus integration for power, sampling at 5 sec, and use recorder exclusions to prevent storing these. Like you, I am using this in automations to decide when to turn things on (hot water and ventilation fans) and to increase/decrease charging rate to my EV based on current solar output.
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
I prefer a near real time view as to what's going on, like when you use the SE app so I'm polling every 8 seconds. Depending on how many devices you have connected to your SE inverter the response time from it varies. In my environment I found it typically responds within 2-4 seconds so lifting it to 8 seconds to add some buffer.
For me, I'm polling more frequently as our house only uses elec, apart from the gas boiler, so the increased frequency of polling lets me spot a load above what the inverter can supply and then delay that consumption to reduce import. For example washing machine, kettle, dishwasher, cooker etc. can often pause 1-2 minutes ready for it's turn. Some of that delay is manual, some is automatic. The API sync to SE at 15minutes just didn't let me achieve that.
I used to keep 60 days of data with some filtering filtered and my DB was about 5-6GB (I know!). I have 30 zigbee devices so they were also polluting it a little by storing all the devices related entity data in attributes ("Home Assistant legacy entity attributes" in Z2MQTT), so I've been able to turn that off now which will also help.
I've recently gone down to storing just 14 days and make more use of HA statistics data. Currently DB is about 1.5GB. I'm using MariaDB.
Today doing my ROI calculations, I actually still go back to the data captured using the SolarEdge app/website and export CSVs to look at generation/import/export, and then use HA identify our house load.