EV4.3 Grounding | |
EV4.3.1 All electrically conductive parts of the vehicle (e.g. parts made of steel, (anodized) aluminum, any | |
other metal parts, etc.) which are within 100mm of any tractive system or GLV component, and any | |
driver harness mounting points, seat mounting points and driver controls must have a resistance below | |
300 mOhms (measured with a current of 1A) to GLV system ground. | |
EV4.3.2 All parts of the vehicle which may become electrically conductive (e.g. completely coated metal parts, | |
carbon fiber parts, etc.) which are within 100mm of any tractive system or GLV component, must | |
have a resistance below 5 Ohm to GLV system ground. | |
EV4.3.3 Electrical conductivity of any part may be tested by checking any point which is likely to be | |
conductive, for example the driver's harness attachment bolt, but where no convenient conductive | |
point is available then an area of coating may be removed. | |
NOTE: Carbon fiber parts may need special measures such as using copper mesh or similar to keep | |
the ground resistance below 5 Ohms. |