# Sofar 3.3-12KTLX-G3 | |
# Note: no modbus energy meter connected | |
requests: | |
- start: 0x0404 | |
end: 0x042E | |
mb_functioncode: 0x03 | |
- start: 0x0484 | |
end: 0x04BC | |
mb_functioncode: 0x03 | |
- start: 0x0584 | |
end: 0x0589 | |
mb_functioncode: 0x03 | |
- start: 0x0684 | |
end: 0x069B | |
mb_functioncode: 0x03 | |
parameters: | |
- group: InverterDC | |
items: | |
- name: "PV1 Power" | |
class: "power" | |
state_class: "measurement" | |
uom: "W" | |
scale: 10 | |
rule: 1 | |
registers: [0x0586] | |
icon: 'mdi:solar-power' | |
- name: "PV2 Power" | |
class: "power" | |
state_class: "measurement" | |
uom: "W" | |
scale: 10 | |
rule: 1 | |
registers: [0x0589] | |
icon: 'mdi:solar-power' | |
- name: "PV1 Voltage" | |
class: "voltage" | |
state_class: "measurement" | |
uom: "V" | |
scale: 0.1 | |
rule: 1 | |
registers: [0x0584] | |
icon: 'mdi:alpha-v-circle-outline' | |
- name: "PV2 Voltage" | |
class: "voltage" | |
state_class: "measurement" | |
uom: "V" | |
scale: 0.1 | |
rule: 1 | |
registers: [0x0587] | |
icon: 'mdi:alpha-v-circle-outline' | |
- name: "PV1 Current" | |
class: "current" | |
state_class: "measurement" | |
uom: "A" | |
scale: 0.01 | |
rule: 1 | |
registers: [0x0585] | |
icon: 'mdi:current-dc' | |
- name: "PV2 Current" | |
class: "current" | |
state_class: "measurement" | |
uom: "A" | |
scale: 0.01 | |
rule: 1 | |
registers: [0x0588] | |
icon: 'mdi:current-dc' | |
- group: Inverter | |
items: | |
- name: "Inverter status" | |
class: "" | |
state_class: "measurement" | |
uom: "" | |
scale: 1 | |
rule: 1 | |
registers: [0x0404] | |
lookup: | |
- key: 0 | |
value: "Waiting" | |
- key: 1 | |
value: "Detection" | |
- key: 2 | |
value: "Grid-Connected" | |
- key: 3 | |
value: "Emergency Power Supply" | |
- key: 4 | |
value: "Recoverable Fault" | |
- key: 5 | |
value: "Permanent Fault" | |
- key: 6 | |
value: "Upgrade" | |
- key: 7 | |
value: "Self-charging" | |
icon: 'mdi:wrench' | |
- name: "Ambient temperature 1" | |
class: "temperature" | |
uom: "°C" | |
scale: 1 | |
rule: 2 | |
registers: [0x0418] | |
icon: 'mdi:thermometer' | |
- name: "Module temperature 1" | |
class: "temperature" | |
uom: "°C" | |
scale: 1 | |
rule: 2 | |
registers: [0x0420] | |
icon: 'mdi:thermometer' | |
- name: "Radiator temperature 1" | |
class: "temperature" | |
uom: "°C" | |
scale: 1 | |
rule: 2 | |
registers: [0x041A] | |
icon: 'mdi:thermometer' | |
- name: "Insulation Resistance" | |
class: "none" | |
uom: "kohm" | |
scale: 1 | |
rule: 1 | |
registers: [0x042B] | |
icon: "mdi:omega" | |
- group: OnGridOutput | |
items: | |
- name: "Frequency Grid" | |
class: "frequency" | |
uom: "Hz" | |
scale: 0.01 | |
rule: 1 | |
registers: [0x0484] | |
icon: 'mdi:sine-wave' | |
- name: "Total Active Power Output" | |
class: "energy" | |
uom: "kW" | |
scale: 0.01 | |
rule: 1 | |
registers: [0x0485] | |
icon: "mdi:solar-power" | |
- name: "Grid Voltage L1" | |
class: "voltage" | |
uom: "V" | |
scale: 0.1 | |
rule: 1 | |
registers: [0x048D] | |
icon: "mdi:alpha-v-circle-outline" | |
- name: "Grid Current L1" | |
class: "current" | |
uom: "A" | |
scale: 0.01 | |
rule: 1 | |
registers: [0x048E] | |
icon: "mdi:alpha-a-circle-outline" | |
- name: "Grid Voltage L2" | |
class: "voltage" | |
uom: "V" | |
scale: 0.1 | |
rule: 1 | |
registers: [0x0498] | |
icon: "mdi:alpha-v-circle-outline" | |
- name: "Grid Current L2" | |
class: "current" | |
uom: "A" | |
scale: 0.01 | |
rule: 1 | |
registers: [0x0499] | |
icon: "mdi:alpha-a-circle-outline" | |
- name: "Grid Voltage L3" | |
class: "voltage" | |
uom: "V" | |
scale: 0.1 | |
rule: 1 | |
registers: [0x04A3] | |
icon: "mdi:alpha-v-circle-outline" | |
- name: "Grid Current L3" | |
class: "current" | |
uom: "A" | |
scale: 0.01 | |
rule: 1 | |
registers: [0x04A4] | |
icon: "mdi:alpha-a-circle-outline" | |
- group: Generation | |
items: | |
- name: "PV Generation today" | |
class: "energy" | |
state_class: "total_increasing" | |
uom: "kWh" | |
scale: 0.01 | |
rule: 3 | |
registers: [0x0685,0x0684] | |
icon: 'mdi:solar-power' | |
- name: "PV Generation total" | |
class: "energy" | |
state_class: "total_increasing" | |
uom: "kWh" | |
scale: 0.1 | |
rule: 3 | |
registers: [0x0687,0x0686] | |
icon: 'mdi:solar-power' | |
- name: "Load consumption today" | |
class: "energy" | |
state_class: "total_increasing" | |
uom: "kWh" | |
scale: 0.01 | |
rule: 3 | |
registers: [0x0689,0x0688] | |
icon: 'mdi:lightning-bolt-outline' | |
- name: "Load consumption total" | |
class: "energy" | |
state_class: "total_increasing" | |
uom: "kWh" | |
scale: 0.1 | |
rule: 3 | |
registers: [0x068B,0x068A] | |
icon: 'mdi:solar-power' | |
- group: Alert | |
items: | |
- name: "Alert" | |
class: "" | |
state_class: "" | |
uom: "" | |
scale: 1 | |
rule: 6 | |
registers: [0x0405,0x0406,0x0407,0x0408,0x0409,0x040A,0x040B,0x040C,0x040D,0x040E,0x040F,0x0410] | |
- name: "Fault 1" | |
class: "" | |
state_class: "" | |
uom: "" | |
scale: 1 | |
rule: 1 | |
registers: [0x0405] | |
icon: 'mdi:wrench' | |
lookup: | |
- key: 0 | |
value: "No error" | |
- key: 1 | |
value: "ID01 Grid Over Voltage Protection" | |
- key: 2 | |
value: "ID02 Grid Under Voltage Protection" | |
- key: 4 | |
value: "ID03 Grid Over Frequency Protection" | |
- key: 8 | |
value: "ID04 Grid Under Frequency Protection" | |
- key: 16 | |
value: "ID05 Leakage current fault" | |
- key: 32 | |
value: "ID06 High penetration error" | |
- key: 64 | |
value: "ID07 Low penetration error" | |
- key: 128 | |
value: "ID08 Islanding error" | |
- key: 256 | |
value: "ID09 Grid voltage transient value overvoltage 1" | |
- key: 512 | |
value: "ID10 Grid voltage transient value overvoltage 2" | |
- key: 1024 | |
value: "ID11 Grid line voltage error" | |
- key: 2048 | |
value: "ID12 Inverter voltage error" | |
- key: 4096 | |
value: "ID13 Anti-backflow overload" | |
- key: 8192 | |
value: "ID14" | |
- key: 16384 | |
value: "ID15" | |
- key: 32768 | |
value: "ID16" | |
- name: "Fault 2" | |
class: "" | |
state_class: "" | |
uom: "" | |
scale: 1 | |
rule: 1 | |
icon: 'mdi:wrench' | |
registers: [0x0406] | |
lookup: | |
- key: 0 | |
value: "No error" | |
- key: 1 | |
value: "ID17 Grid current sampling error" | |
- key: 2 | |
value: "ID18 Grid current DC component sampling error (AC side)" | |
- key: 4 | |
value: "ID19 Grid voltage sampling error (DC side)" | |
- key: 8 | |
value: "ID20 Grid voltage sampling error (AC side)" | |
- key: 16 | |
value: "ID21 Leakage current sampling error (DC side)" | |
- key: 32 | |
value: "ID22 Leakage current sampling error (AC side)" | |
- key: 64 | |
value: "ID23 Load voltage DC component sampling error" | |
- key: 128 | |
value: "ID24 DC input current sampling error" | |
- key: 256 | |
value: "ID25 DC component sampling error of grid current (DC side)" | |
- key: 512 | |
value: "ID26 DC input branch current sampling error" | |
- key: 1024 | |
value: "ID27" | |
- key: 2048 | |
value: "ID28" | |
- key: 4096 | |
value: "ID29 Leakage current consistency error" | |
- key: 8192 | |
value: "ID30 Grid voltage consistency error" | |
- key: 16384 | |
value: "ID31 DCI consistency error" | |
- key: 32768 | |
value: "ID32" |
I have a 6KTLM-G3-A and using all info that you guys provided here, Ive made my own version. Hope it helps someone.
Ps. only "Alert sensor" not working
I dont know how to paste the code here, but the link is below.
https://gist.github.com/gushcs/223ca2c61af2d345238d286746617650
I tried your code but somehow it isn't working. Should this work with a LSE-3 logger and Solarman integration?
Same here. This yaml config file does not work with my KTL-X-G3 inverter and LSW3 wifi logger (serial 23500xxxxx). Status_connection shows disconnected and most values list as unavailable. The solarman integration works with config file sofar_lsw3.yaml (but this shows incorrect values in the registers since they do not map with my inverter).
If you would have any pointers on how to troubleshoot this then they would be much appreciated!
I finally got it working with this file: custom_parameters.yaml.txt (with LSMW3_15_270A_1.50 and SOFAR 8.8KTLX-G3)
I finally got it working with this file: custom_parameters.yaml.txt (with LSMW3_15_270A_1.50 and SOFAR 8.8KTLX-G3)
WORKS FOR ME AS WELL!
Glad I could help.
Yes, mine is 3 phase. So I guess it does not support CT clamps, but requires a smart meter.