package de.wenzlaff;
import java.time.LocalDateTime;
import org.eclipse.paho.client.mqttv3.IMqttDeliveryToken;
import org.eclipse.paho.client.mqttv3.MqttCallback;
import org.eclipse.paho.client.mqttv3.MqttClient;
import org.eclipse.paho.client.mqttv3.MqttException;
import org.eclipse.paho.client.mqttv3.MqttMessage;
import org.json.JSONArray;
import org.json.JSONException;
import org.json.JSONObject;
/**
* Paho MQTT-CO2 Client.
*
* Beispiele siehe
*
* http://www.wenzlaff.info
*
* @author Thomas Wenzlaff
*
*/
public class MqttCo2Client {
/** Der Server mit dem MQTT Broker. */
private static final String DEFAULT_SERVER = "localhost";
/** Der abonnierte Topic. */
private static final String TOPIC = "co2";
/** ID Prefix für den Client. */
private static final String CLIENT_ID = "id-";
private static int co2WertInPpm;
public enum LÜFTUNGSAMPEL {
/** Kohlendioxid-Leitwert als Lüftungsampel. */
GRÜN, GELB, ROT
}
public static int getCo2WertInPpm() {
return co2WertInPpm;
}
/**
* Startet eine MQTT Client der an den Topic co2 abonniert ist. Im Hintergurnd
* werden die Werte mit Bewertung auf System.out ausgegeben.
*
* @param args der Server
* @throws MqttException bei verbindungs Problemen
* @throws Exception bei Fehler
*/
public static void start() throws Exception {
MqttClient client = new MqttClient("tcp://" + DEFAULT_SERVER, generateClientId());
System.out.println("Starte den CO2 MQTT-Client mit Server " + DEFAULT_SERVER + " und ID: " + client.getClientId() + " ...");
client.setCallback(new MqttCallback() {
@Override
public void connectionLost(Throwable throwable) {
}
@Override
public void messageArrived(String topic, MqttMessage nachricht) throws Exception {
leseCo2(nachricht);
}
private void leseCo2(MqttMessage nachricht) {
JSONObject jsonNachricht = new JSONObject(nachricht.toString());
try {
JSONArray nachrichten = jsonNachricht.getJSONObject("messung").getJSONArray("satz");
JSONObject satz = (JSONObject) nachrichten.get(1);
int co2 = satz.getInt("co2");
System.out.println("CO2: " + co2 + " ppm");
co2WertInPpm = co2;
bewertungUBAausgeben(co2);
} catch (JSONException e) {
System.err.println(e);
}
}
@Override
public void deliveryComplete(IMqttDeliveryToken t) {
}
});
client.connect();
client.subscribe(TOPIC);
}
/**
* Quelle:
* https://www.hamburg.de/contentblob/1016516/7073fd694816ce7e8edd0eb82a2593e6/data/gesundheitliche-bewertung-co2.pdf
*
* https://www.dguv.de/medien/ifa/de/pub/rep/pdf/reports2013/innenraumarbeitsplaetze/kapitel_12_4_1.pdf
*
* @param co2 Wert in ppm
*/
static LÜFTUNGSAMPEL bewertungUBAausgeben(int co2) {
if (co2 < 1000) {
System.out.println("Laut UBA GRÜN: Hygienisch unbedenklich, keine weiteren Maßnahmen");
return LÜFTUNGSAMPEL.GRÜN;
} else if (co2 >= 1000 && co2 < 2000) {
System.out.println("Laut UBA GELB: Hygienisch auffällig, Lüftungsmaßnahmen erhöhen, Lüftungsverhalten überprüfen und verbessern");
return LÜFTUNGSAMPEL.GELB;
} else {
System.out.println("Laut UBA ROT: Hygienisch inakzeptabel, Belüftbarkeit des Raumes prüfen ggf. weitergehende Maßnahmen prüfen");
return LÜFTUNGSAMPEL.ROT;
}
}
private static String generateClientId() {
return CLIENT_ID + LocalDateTime.now();
}
}
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment