# Helpful information: | |
# https://github.com/Excodibur/ioBroker.schwoerer-ventcube/blob/master/src/lib/schwoerer/parameters.ts | |
# https://github.com/fgoettel/wgt/blob/main/wgt/lueftungsanlage.py | |
# https://knx-user-forum.de/forum/öffentlicher-bereich/knx-eib-forum/diy-do-it-yourself/1822296-modbus-schwörer-heizung?p=1906252#post1906252 | |
################## | |
# MODBUS SENSORS # | |
################## | |
modbus: | |
- name: BIC_VentCube | |
delay: 2 | |
timeout: 3 | |
type: tcp | |
host: !secret wgt_ip | |
port: 502 | |
sensors: | |
- name: VentCube Betriebsart | |
slave: 1 | |
unique_id: ventcube_betriebsart | |
address: 100 | |
# Translated with template sensor | |
# Translated with input_select Automation | |
- name: VentCube Manuelle Luftstufe | |
slave: 1 | |
unique_id: ventcube_manuelle_luftstufe | |
address: 101 | |
# Translated with input_select Automation | |
- name: VentCube Aktuelle Luftstufe | |
slave: 1 | |
unique_id: ventcube_aktuelle_luftstufe | |
address: 102 | |
- name: VentCube Status Stoßlüftung | |
slave: 1 | |
unique_id: ventcube_status_stosslueftung | |
address: 111 | |
# Translated with template sensor | |
- name: VentCube Restlaufzeit Stoßlüftung | |
slave: 1 | |
unique_id: ventcube_restlaufzeit_stosslueftung | |
address: 112 | |
unit_of_measurement: min | |
device_class: duration | |
min_value: 0 | |
max_value: 60 | |
- name: VentCube Status Wärmepumpe | |
slave: 1 | |
unique_id: ventcube_status_waermepumpe | |
address: 114 | |
# Translated with template sensor | |
- name: VentCube Status Nachheizregister | |
slave: 1 | |
unique_id: ventcube_status_nachheizregister | |
address: 116 | |
# Translated with template sensor | |
- name: VentCube Status Gebläse Zuluft | |
slave: 1 | |
unique_id: ventcube_status_geblaese_zuluft | |
address: 117 | |
# Translated with template sensor | |
- name: VentCube Status Gebläse Abluft | |
slave: 1 | |
unique_id: ventcube_status_geblaese_abluft | |
address: 118 | |
# Translated with template sensor | |
- name: VentCube Zustand Bypass | |
slave: 1 | |
unique_id: ventcube_bypass_zustand | |
address: 123 | |
# Translated with template sensor | |
- name: VentCube Zustand Außenklappe | |
slave: 1 | |
unique_id: ventcube_zustand_aussenklappe | |
address: 131 | |
# Translated with template sensor | |
- name: VentCube Status Vorheizregister | |
slave: 1 | |
unique_id: ventcube_status_vorheizregister | |
address: 133 | |
# Translated with template sensor | |
- name: VentCube aktuelle Luftleistung Zuluft | |
slave: 1 | |
unique_id: ventcube_aktuelle_luftleistung_zuluft | |
address: 142 | |
state_class: measurement | |
unit_of_measurement: "%" | |
min_value: 0 | |
max_value: 100 | |
scale: 1 | |
precision: 0 | |
- name: VentCube aktuelle Luftleistung Abluft | |
unique_id: ventcube_aktuelle_luftleistung_abluft | |
slave: 1 | |
address: 143 | |
state_class: measurement | |
unit_of_measurement: "%" | |
min_value: 0 | |
max_value: 100 | |
scale: 1 | |
precision: 0 | |
- name: VentCube aktuelle Drehzahl Zuluft | |
unique_id: ventcube_aktuelle_drehzahl_zuluft | |
slave: 1 | |
address: 144 | |
state_class: measurement | |
unit_of_measurement: "rpm" | |
min_value: 0 | |
max_value: 10000 | |
precision: 0 | |
- name: VentCube aktuelle Drehzahl Abluft | |
unique_id: ventcube_aktuelle_drehzahl_abluft | |
slave: 1 | |
address: 145 | |
state_class: measurement | |
unit_of_measurement: "rpm" | |
min_value: 0 | |
max_value: 10000 | |
precision: 0 | |
- name: VentCube T2 Temperatur nach Vorheizregister | |
slave: 1 | |
unique_id: ventcube_t2_temperatur_nach_vorheizregister | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 201 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T3 Temperatur vor Nacherwärmung | |
slave: 1 | |
unique_id: ventcube_t3_temperatur_vor_nacherwaermung | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 202 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T4 Temperatur nach Nacherwärmung | |
slave: 1 | |
unique_id: ventcube_t4_temperatur_nach_nacherwaermung | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 203 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T5 Temperatur Abluft | |
slave: 1 | |
unique_id: ventcube_t5_temperatur_abluft | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 204 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T6 Temperatur im Wärmetauscher | |
slave: 1 | |
unique_id: ventcube_t6_temperatur_im_waermetauscher | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 205 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T10 Temperatur Außen | |
slave: 1 | |
unique_id: ventcube_t10_temperatur_aussen | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 209 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube Heiz- Kühlfunktion | |
slave: 1 | |
unique_id: ventcube_heiz_kuehlfunktion | |
address: 230 | |
# Translated with template sensor | |
# Translated with input_select Automation | |
- name: VentCube Wärmepumpe Heizen | |
slave: 1 | |
unique_id: ventcube_wp_heizen | |
address: 231 | |
- name: VentCube Wärmepumpe Kühlen | |
slave: 1 | |
unique_id: ventcube_wp_kuehlen | |
address: 232 | |
- name: VentCube Druckwächter aktiv | |
slave: 1 | |
unique_id: ventcube_druckwachter_aktiv | |
address: 242 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube EVU Sperre aktiv | |
slave: 1 | |
unique_id: ventcube_evu_sperre_aktiv | |
address: 243 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Wartungstür offen | |
slave: 1 | |
unique_id: ventcube_wartungstur_offen | |
address: 244 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Gerätefilter verschmutzt | |
slave: 1 | |
unique_id: ventcube_geratefilter_verschmutzt | |
address: 245 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Vorgelagerter Filter verschmutzt | |
slave: 1 | |
unique_id: ventcube_vorgelagerter_filter_verschmutzt | |
address: 246 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Zuluft zu kalt | |
slave: 1 | |
unique_id: ventcube_zuluft_zu_kalt | |
address: 254 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Restlaufzeit Gerätefilter | |
slave: 1 | |
unique_id: ventcube_restlaufzeit_geratefilter | |
address: 265 | |
unit_of_measurement: d | |
min_value: 0 | |
max_value: 255 | |
device_class: duration | |
- name: VentCube Temperatur Wohnzimmer IST | |
slave: 1 | |
unique_id: ventcube_temperatur_wohnzimmer_ist | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 360 | |
scale: 0.1 | |
precision: 1 | |
min_value: 0 | |
max_value: 100 | |
switches: | |
- name: VentCube Freigabe WP auf Heizen | |
slave: 1 | |
address: 231 | |
command_on: 0x1 # Freigabe | |
command_off: 0x0 # Gesperrt | |
write_type: holdings | |
verify: | |
input_type: holding | |
state_on: 0x1 | |
state_off: 0x0 | |
delay: 5 | |
unique_id: ventcube_set_waermepumpe_heizen | |
- name: VentCube Freigabe WP auf Kühlen | |
slave: 1 | |
address: 232 | |
command_on: 0x1 # Freigabe | |
command_off: 0x0 # Gesperrt | |
write_type: holdings | |
verify: | |
input_type: holding | |
state_on: 0x1 | |
state_off: 0x0 | |
delay: 5 | |
unique_id: ventcube_set_waermepumpe_kuehlen | |
climates: | |
- name: "VentCube Soll-Temperatur" | |
unique_id: ventcube_soll_temperatur | |
slave: 1 | |
address: 400 | |
max_temp: 30 | |
min_temp: 10 | |
offset: 0 | |
precision: 0 | |
scale: 0.1 | |
target_temp_register: 400 | |
target_temp_write_registers: true | |
temp_step: 1 | |
temperature_unit: °C | |
- name: "VentCube Basis-Temperatur" | |
unique_id: ventcube_basis_temperatur | |
slave: 1 | |
address: 420 | |
max_temp: 30 | |
min_temp: 18 | |
offset: 0 | |
precision: 0 | |
scale: 0.1 | |
target_temp_register: 420 | |
target_temp_write_registers: true | |
temp_step: 1 | |
temperature_unit: °C | |
##################################################### | |
# Select Options which require separate Automations # | |
##################################################### | |
input_select: | |
ventcube_manuelle_luftstufe: | |
name: VentCube Manuelle Luftstufe | |
options: | |
- "0 - Aus" | |
- "1 - Stufe 1" | |
- "2 - Stufe 2" | |
- "3 - Stufe 3" | |
- "4 - Stufe 4" | |
- "5 - Automatik" | |
- "6 - Linearbetrieb" | |
icon: mdi:fan | |
ventcube_betriebsart: | |
name: VentCube Betriebsart | |
options: | |
- "0 - Aus" | |
- "1 - Handbetrieb" | |
- "2 - Winterbetrieb" | |
- "3 - Sommerbetrieb" | |
- "4 - Sommer Abluft" | |
icon: mdi:fan | |
ventcube_heiz_kuehlfunktion: | |
name: VentCube Heiz- Kühlfunktion | |
options: | |
- "0 - Aus" | |
- "1 - Heizen" | |
- "2 - Kühlen" | |
- "3 - Auto T-Außen" | |
- "4 - Auto Digitaler Eingang" | |
icon: mdi:fan | |
#################### | |
# TEMPLATE SENSORS # | |
#################### | |
sensor: | |
- platform: template | |
sensors: | |
ventcube_betriebsart_text: | |
unique_id: ventcube_betriebsart_text | |
friendly_name: "VentCube Betriebsart" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'Handbetrieb', | |
'2': 'Winterbetrieb', | |
'3': 'Sommerbetrieb', | |
'4': 'Sommer Abluft'} %} | |
{% set state = states.sensor.ventcube_betriebsart.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_bypass_zustand_text: | |
unique_id: vebtcube_bypass_zustand_text | |
friendly_name: "VentCube Zustand Bypass" | |
value_template: > | |
{% set mapper = { | |
'0': 'Geschlossen', | |
'1': 'Offen (Kühlen)', | |
'2': 'Offen (Heizen)'} %} | |
{% set state = states.sensor.ventcube_bypass_zustand.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_zustand_aussenklappe_text: | |
unique_id: ventcube_zustand_aussenklappe_text | |
friendly_name: "VentCube Zustand Außenklappe" | |
value_template: > | |
{% set mapper = { | |
'0': 'Geschlossen', | |
'1': 'Offen'} %} | |
{% set state = states.sensor.ventcube_zustand_aussenklappe.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_waermepumpe_text: | |
unique_id: ventcube_status_waermepumpe_text | |
friendly_name: "VentCube Status Wärmepumpe" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'5': 'WP Heizen', | |
'49': 'WP Kühlen'} %} | |
{% set state = states.sensor.ventcube_status_waermepumpe.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_heiz_kuehlfunktion_text: | |
unique_id: ventcube_heiz_kuehlfunktion_text | |
friendly_name: "VentCube Status Heiz- Kühlfunktion" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'Heizen', | |
'2': 'Kühlen', | |
'3': 'Auto T-Außen', | |
'4': 'Auto Digitaler Eingang'} %} | |
{% set state = states.sensor.ventcube_heiz_kuehlfunktion.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_nachheizregister_text: | |
unique_id: ventcube_status_nachheizregister_text | |
friendly_name: "VentCube Status Nachheizregister" | |
value_template: > | |
{% set mapper = { | |
'0': 'Inaktiv', | |
'1': 'Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_nachheizregister.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_vorheizregister_text: | |
unique_id: ventcube_status_vorheizregister_text | |
friendly_name: "VentCube Status Vorheizregister" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'VHR1 Aktiv', | |
'2': 'VHR2 Aktiv', | |
'3': 'VHR1+2 Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_vorheizregister.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_stosslueftung_text: | |
unique_id: ventcube_status_stosslueftung_text | |
friendly_name: "VentCube Status Stoßlüftung" | |
value_template: > | |
{% set mapper = { | |
'0': 'Inaktiv', | |
'1': 'Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_stosslueftung.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_geblaese_zuluft_text: | |
unique_id: ventcube_status_geblaese_zuluft_text | |
friendly_name: "VentCube Status Gebläse Zuluft" | |
value_template: > | |
{% set mapper = { | |
'0': 'Deaktiviert', | |
'1': 'Anlaufphase', | |
'2': 'Aktiv', | |
'5': 'Standby', | |
'6': 'Fehler'} %} | |
{% set state = states.sensor.ventcube_status_geblaese_zuluft.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_geblaese_abluft_text: | |
unique_id: ventcube_status_geblaese_abluft_text | |
friendly_name: "VentCube Status Gebläse Abluft" | |
value_template: > | |
{% set mapper = { | |
'0': 'Deaktiviert', | |
'1': 'Anlaufphase', | |
'2': 'Aktiv', | |
'5': 'Standby', | |
'6': 'Fehler'} %} | |
{% set state = states.sensor.ventcube_status_geblaese_abluft.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
template: | |
- binary_sensor: | |
- name: "VentCube Meldung Druckwächter Aktiv" | |
unique_id: ventcube_meldung_druckwachter_aktiv | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_druckwachter_aktiv.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung EVU Sperre aktiv" | |
unique_id: ventcube_meldung_evu_sperre_aktiv | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_evu_sperre_aktiv.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Wartungstür offen" | |
unique_id: ventcube_meldung_wartungstur_offen | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_wartungstur_offen.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Gerätefilter verschmutzt" | |
unique_id: ventcube_meldung_geratefilter_verschmutzt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_geratefilter_verschmutzt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Vorgelagerter Filter verschmutzt" | |
unique_id: ventcube_meldung_vorgelagerter_filter_verschmutzt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'on', | |
'1': 'off'} %} | |
{% set state = states.sensor.ventcube_vorgelagerter_filter_verschmutzt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Zuluft Zu Kalt" | |
unique_id: ventcube_meldung_zuluft_zu_kalt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_zuluft_zu_kalt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
@JavanXD und @VRage Mega großes Dankeschön, funktioniert!
Das Stoßlüften-Skript hatte ich schon von hier quasi 1:1 ausprobiert, allerdings reicht mein copy/paste Halbwissen nicht um herauszufinden, warum der augenscheinlich gleiche Code mit anderen Einrückungen funktioniert und der aus dem KNX-Forum nicht. Aber hey, Haken dran dank Eurer Hilfe!
warum der augenscheinlich gleiche Code mit anderen Einrückungen funktioniert
weil yaml der größte 💩 seit JavaScript ist 😋
Ich bekomme im Bedienteil noch immer folgende Fehlermeldung:
Fehler 02-04
Kommunikation Bus-Sensor
Außerdem steht der Sensor "VentCube Temperatur Wohnzimmer IST" seit einer Woche auf 19,5° C - sowohl in HA als auch auf dem Bedienteil!
Kann einer von Euch einen Hinweis geben, wo ich ansetzen kann?
Im Protokoll werden weiterhin hundertfach Fehler geworfen, sie zeigen allerdings nicht auf die korrespondierende Adresse 360, sondern weiterhin auf die aktuellen Drehzahlen:
Pymodbus: BIC_VentCube: Error: device: 1 address: 142 -> pymodbus returned isError True
Pymodbus: BIC_VentCube: Error: device: 1 address: 145 -> pymodbus returned isError True
Pymodbus: BIC_VentCube: Error: device: 1 address: 143 -> pymodbus returned isError True
Ich bekomme im Bedienteil noch immer folgende Fehlermeldung:
Fehler 02-04
Kommunikation Bus-SensorAußerdem steht der Sensor "VentCube Temperatur Wohnzimmer IST" seit einer Woche auf 19,5° C - sowohl in HA als auch auf dem Bedienteil!
Kann einer von Euch einen Hinweis geben, wo ich ansetzen kann?
Im Protokoll werden weiterhin hundertfach Fehler geworfen, sie zeigen allerdings nicht auf die korrespondierende Adresse 360, sondern weiterhin auf die aktuellen Drehzahlen:
Pymodbus: BIC_VentCube: Error: device: 1 address: 142 -> pymodbus returned isError True
Pymodbus: BIC_VentCube: Error: device: 1 address: 145 -> pymodbus returned isError True
Pymodbus: BIC_VentCube: Error: device: 1 address: 143 -> pymodbus returned isError True
Da würde ich auf ein Fehler im Bedienteil schließen. Schonmal die IT- Silverbullet probiert und das Ding neugestartet? Also komplett mit Sicherung raus für Bedien und Leistungsteil, paar sekunden warten und wieder einschalten?! Ansonsten musst du dich bei Schwörer melden und fragen ob sie dir ein Update haben.
Meine Anlage ist 2.15, in der Doku wird 2.25 genannt. Anfrage nach Update ist raus.
@hessebubmaddin laut parameterliste ist Stoßlüften auf Adresse 111 gelegt und kann geschrieben werden ( mit 0 "inaktiv" und 1 "aktiv" ). Ob das wirklich über modbus Funktioniert müsste ich erst daheim ausprobieren.