Temporary quirk draft for HAOZEE HY08WE
"""Map from manufacturer to standard clusters for thermostatic valves."""
import logging
from typing import Optional, Union
from zigpy.profiles import zha
import zigpy.types as t
from zigpy.zcl.clusters.general import Basic, Groups, Ota, Scenes, Time
from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
from zhaquirks.tuya import (
TuyaManufClusterAttributes,
TuyaThermostat,
TuyaThermostatCluster,
TuyaUserInterfaceCluster,
)
# from https://github.com/Koenkk/zigbee-herdsman-converters/pull/1694/
HAOZEE_SCHEDULE_WORKDAYS_AM_ATTR = (
0x0077 # schedule for workdays [8, 0, 20, 8, 1, 15, 11, 30, 15]
)
HAOZEE_SCHEDULE_WORKDAYS_PM_ATTR = (
0x0078 # schedule for workdays [13, 30, 15, 17, 0, 15, 150, 0, 15]
)
HAOZEE_SCHEDULE_WEEKEND_AM_ATTR = (
0x0079 # schedule for weekend [6, 0, 20, 8, 0, 15, 11, 30, 15]
)
HAOZEE_SCHEDULE_WEEKEND_PM_ATTR = (
0x007A # schedule for weekend [13, 30, 15, 17, 0, 15, 22, 0, 15]
)
HAOZEE_HEATING_ENABLED_ATTR = 0x0166 # [0] idle [1] heating
HAOZEE_MAX_TEMP_PROTECTION_ENABLED_ATTR = (
0x016A # minimal temp protection [0] disabled [1] enabled
)
HAOZEE_MIN_TEMP_PROTECTION_ENABLED_ATTR = (
0x016B # maximal temp protection [0] disabled [1] enabled
)
HAOZEE_ENABLED_ATTR = 0x017D # device status [0] disabled [1] enabled
HAOZEE_CHILD_LOCK_ATTR = 0x0181 # [0] unlocked [1] child-locked
HAOZEE_EXT_TEMP_ATTR = 0x0267 # external NTC sensor temp (decidegree)
HAOZEE_AWAY_DAYS_ATTR = 0x0268 # away mode duration (days)
HAOZEE_AWAY_TEMP_ATTR = 0x0269 # away mode temperature (decidegree)
HAOZEE_TEMP_CALIBRATION_ATTR = 0x026D # temperature calibration (decidegree)
HAOZEE_TEMP_HYSTERESIS_ATTR = 0x026E # temperature hysteresis (decidegree)
HAOZEE_TEMP_PROTECT_HYSTERESIS_ATTR = (
0x026F # temperature hysteresis for protection (decidegree)
)
HAOZEE_MAX_PROTECT_TEMP_ATTR = (
0x0270 # maximal temp for protection trigger (decidegree)
)
HAOZEE_MIN_PROTECT_TEMP_ATTR = (
0x0271 # minimal temp for protection trigger (decidegree)
)
HAOZEE_MAX_TEMP_LIMIT_ATTR = 0x0272 # maximum limit of temperature setting (decidegree)
HAOZEE_MIN_TEMP_LIMIT_ATTR = 0x0273 # minimum limit of temperature setting (decidegree)
HAOZEE_TARGET_TEMP_ATTR = 0x027E # target temperature (decidegree)
HAOZEE_CURRENT_ROOM_TEMP_ATTR = (
0x027F # temperature reported by MCU. Depends on sensor type. (decidegree)
)
HAOZEE_SENSOR_TYPE_ATTR = 0x0474 # sensor type [0] internal [1] external [2] both
HAOZEE_POWERON_BEHAVIOR_ATTR = 0x0475 # poweron behavior [0] restore [1] off [2] on
HAOZEE_WEEKFORMAT = 0x0476 # [0] 5+2 [1] 6+1 [2] 7 (days)
HAOZEE_CURRENT_MODE_ATTR = 0x0480 # [0] manual [1] auto [2] away
HAOZEE_FAULT_ATTR = 0x0582 # Known fault codes: [4] E2 external sensor error
#Unknown DP - descaling on/off, window detection, window detection settings
_LOGGER = logging.getLogger(__name__)
class HY08WEManufCluster(TuyaManufClusterAttributes):
"""Manufacturer Specific Cluster of some thermostatic valves."""
# Important! This device uses offset from 2000 year for UTC time and offset from 1970 for local time
set_time_offset = 2000
set_time_local_offset = 1970
manufacturer_attributes = {
HAOZEE_HEATING_ENABLED_ATTR: ("heating_enabled", t.uint8_t),
HAOZEE_MAX_TEMP_PROTECTION_ENABLED_ATTR: (
"max_temp_protection_enabled",
t.uint8_t,
),
HAOZEE_MIN_TEMP_PROTECTION_ENABLED_ATTR: (
"min_temp_protection_enabled",
t.uint8_t,
),
HAOZEE_ENABLED_ATTR: ("enabled", t.uint8_t),
HAOZEE_CHILD_LOCK_ATTR: ("child_lock", t.uint8_t),
HAOZEE_EXT_TEMP_ATTR: ("external_temperature", t.uint32_t),
HAOZEE_AWAY_DAYS_ATTR: ("away_duration_days", t.uint32_t),
HAOZEE_AWAY_TEMP_ATTR: ("away_mode_temperature", t.uint32_t),
HAOZEE_TEMP_CALIBRATION_ATTR: ("temperature_calibration", t.int32s),
HAOZEE_TEMP_HYSTERESIS_ATTR: ("hysterisis_temperature", t.uint32_t),
HAOZEE_TEMP_PROTECT_HYSTERESIS_ATTR: (
"hysterisis_protection_temperature",
t.uint32_t,
),
HAOZEE_MAX_PROTECT_TEMP_ATTR: ("max_protection_temperature", t.uint32_t),
HAOZEE_MIN_PROTECT_TEMP_ATTR: ("min_protection_temperature", t.uint32_t),
HAOZEE_MAX_TEMP_LIMIT_ATTR: ("max_temperature", t.uint32_t),
HAOZEE_MIN_TEMP_LIMIT_ATTR: ("min_temperature", t.uint32_t),
HAOZEE_TARGET_TEMP_ATTR: ("target_temperature", t.uint32_t),
HAOZEE_CURRENT_ROOM_TEMP_ATTR: ("internal_temperature", t.uint32_t),
HAOZEE_SENSOR_TYPE_ATTR: ("sensor_settings", t.uint8_t),
HAOZEE_POWERON_BEHAVIOR_ATTR: ("poweron_behavior", t.uint8_t),
HAOZEE_WEEKFORMAT: ("week_format", t.uint8_t),
HAOZEE_CURRENT_MODE_ATTR: ("mode", t.uint8_t),
HAOZEE_FAULT_ATTR: ("fault", t.uint8_t),
}
DIRECT_MAPPED_ATTRS = {
HAOZEE_CURRENT_ROOM_TEMP_ATTR: ("local_temp", lambda value: value * 10),
HAOZEE_TARGET_TEMP_ATTR: (
"occupied_heating_setpoint",
lambda value: value * 10,
),
HAOZEE_AWAY_TEMP_ATTR: (
"unoccupied_heating_setpoint",
lambda value: value * 100,
),
HAOZEE_TEMP_CALIBRATION_ATTR: (
"local_temperature_calibration",
lambda value: value * 10,
),
HAOZEE_MIN_TEMP_LIMIT_ATTR: (
"min_heat_setpoint_limit",
lambda value: value * 100,
),
HAOZEE_MAX_TEMP_LIMIT_ATTR: (
"max_heat_setpoint_limit",
lambda value: value * 100,
),
HAOZEE_AWAY_DAYS_ATTR: ("unoccupied_duration_days", None),
}
def _update_attribute(self, attrid, value):
super()._update_attribute(attrid, value)
if attrid in self.DIRECT_MAPPED_ATTRS:
self.endpoint.device.thermostat_bus.listener_event(
"temperature_change",
self.DIRECT_MAPPED_ATTRS[attrid][0],
value
if self.DIRECT_MAPPED_ATTRS[attrid][1] is None
else self.DIRECT_MAPPED_ATTRS[attrid][1](
value
), # decidegree to centidegree
)
elif attrid == HAOZEE_ENABLED_ATTR:
self.endpoint.device.thermostat_bus.listener_event("enabled_change", value)
elif attrid == HAOZEE_HEATING_ENABLED_ATTR:
self.endpoint.device.thermostat_bus.listener_event("state_change", value)
elif attrid == HAOZEE_CURRENT_MODE_ATTR:
self.endpoint.device.thermostat_bus.listener_event("mode_change", value)
elif attrid == HAOZEE_CHILD_LOCK_ATTR:
self.endpoint.device.ui_bus.listener_event("child_lock_change", value)
class HY08WEThermostat(TuyaThermostatCluster):
"""Thermostat cluster for some thermostatic valves."""
DIRECT_MAPPING_ATTRS = {
"occupied_heating_setpoint": (
HAOZEE_TARGET_TEMP_ATTR,
lambda value: round(value / 10),
),
"unoccupied_heating_setpoint": (
HAOZEE_AWAY_TEMP_ATTR,
lambda value: round(value / 100),
),
"min_heat_setpoint_limit": (
HAOZEE_MIN_TEMP_LIMIT_ATTR,
lambda value: round(value / 100),
),
"max_heat_setpoint_limit": (
HAOZEE_MAX_TEMP_LIMIT_ATTR,
lambda value: round(value / 100),
),
"local_temperature_calibration": (
HAOZEE_TEMP_CALIBRATION_ATTR,
lambda value: round(value / 10),
),
}
def map_attribute(self, attribute, value):
"""Map standardized attribute value to dict of manufacturer values."""
if attribute in self.DIRECT_MAPPING_ATTRS:
return {
self.DIRECT_MAPPING_ATTRS[attribute][0]: value
if self.DIRECT_MAPPING_ATTRS[attribute][1] is None
else self.DIRECT_MAPPING_ATTRS[attribute][1](value)
}
if attribute == "system_mode":
if value == self.SystemMode.Off:
return {HAOZEE_ENABLED_ATTR: 0}
if value == self.SystemMode.Heat:
return {HAOZEE_ENABLED_ATTR: 1}
self.error("Unsupported value for SystemMode")
if attribute == "programing_oper_mode":
if value == self.ProgrammingOperationMode.Simple:
return {HAOZEE_CURRENT_MODE_ATTR: 0}
if value == self.ProgrammingOperationMode.Schedule_programming_mode:
return {HAOZEE_CURRENT_MODE_ATTR: 1}
if value == self.ProgrammingOperationMode.Economy_mode:
return {HAOZEE_CURRENT_MODE_ATTR: 2}
self.error("Unsupported value for ProgrammingOperationMode")
def mode_change(self, value):
"""System Mode change."""
occupancy = self.Occupancy.Occupied
if value == 0:
prog_mode = self.ProgrammingOperationMode.Simple
elif value == 1:
prog_mode = self.ProgrammingOperationMode.Schedule_programming_mode
elif value == 2:
prog_mode = self.ProgrammingOperationMode.Simple
occupancy = self.Occupancy.Unoccupied
self._update_attribute(self.attridx["programing_oper_mode"], prog_mode)
self._update_attribute(self.attridx["occupancy"], occupancy)
def enabled_change(self, value):
"""System mode change."""
if value == 0:
mode = self.SystemMode.Off
else:
mode = self.SystemMode.Heat
self._update_attribute(self.attridx["system_mode"], mode)
class HY08WEUserInterface(TuyaUserInterfaceCluster):
"""HVAC User interface cluster for tuya electric heating thermostats."""
_CHILD_LOCK_ATTR = HAOZEE_CHILD_LOCK_ATTR
class HY08WE(TuyaThermostat):
"""Haozee HY08WE Thermostatic radiator valve."""
signature = {
# endpoint=1 profile=260 device_type=81 device_version=1 input_clusters=[0, 4, 5, 61184],
# output_clusters=[25, 10]
MODELS_INFO: [("_TZE200_znzs7yaw", "TS0601")],
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaManufClusterAttributes.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.THERMOSTAT,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
HY08WEManufCluster,
HY08WEThermostat,
HY08WEUserInterface,
],
OUTPUT_CLUSTERS: [Ota.cluster_id, Time.cluster_id],
}
}
}
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment