"""Map from manufacturer to standard clusters for thermostatic valves.""" | |
import logging | |
from typing import Optional, Union | |
from zigpy.profiles import zha | |
import zigpy.types as t | |
from zigpy.zcl.clusters.general import Basic, Groups, Ota, Scenes, Time | |
from zhaquirks.const import ( | |
DEVICE_TYPE, | |
ENDPOINTS, | |
INPUT_CLUSTERS, | |
MODELS_INFO, | |
OUTPUT_CLUSTERS, | |
PROFILE_ID, | |
) | |
from zhaquirks.tuya import ( | |
TuyaManufClusterAttributes, | |
TuyaThermostat, | |
TuyaThermostatCluster, | |
TuyaUserInterfaceCluster, | |
) | |
# from https://github.com/Koenkk/zigbee-herdsman-converters/pull/1694/ | |
HAOZEE_SCHEDULE_WORKDAYS_AM_ATTR = ( | |
0x0077 # schedule for workdays [8, 0, 20, 8, 1, 15, 11, 30, 15] | |
) | |
HAOZEE_SCHEDULE_WORKDAYS_PM_ATTR = ( | |
0x0078 # schedule for workdays [13, 30, 15, 17, 0, 15, 150, 0, 15] | |
) | |
HAOZEE_SCHEDULE_WEEKEND_AM_ATTR = ( | |
0x0079 # schedule for weekend [6, 0, 20, 8, 0, 15, 11, 30, 15] | |
) | |
HAOZEE_SCHEDULE_WEEKEND_PM_ATTR = ( | |
0x007A # schedule for weekend [13, 30, 15, 17, 0, 15, 22, 0, 15] | |
) | |
HAOZEE_HEATING_ENABLED_ATTR = 0x0166 # [0] idle [1] heating | |
HAOZEE_MAX_TEMP_PROTECTION_ENABLED_ATTR = ( | |
0x016A # minimal temp protection [0] disabled [1] enabled | |
) | |
HAOZEE_MIN_TEMP_PROTECTION_ENABLED_ATTR = ( | |
0x016B # maximal temp protection [0] disabled [1] enabled | |
) | |
HAOZEE_ENABLED_ATTR = 0x017D # device status [0] disabled [1] enabled | |
HAOZEE_CHILD_LOCK_ATTR = 0x0181 # [0] unlocked [1] child-locked | |
HAOZEE_EXT_TEMP_ATTR = 0x0267 # external NTC sensor temp (decidegree) | |
HAOZEE_AWAY_DAYS_ATTR = 0x0268 # away mode duration (days) | |
HAOZEE_AWAY_TEMP_ATTR = 0x0269 # away mode temperature (decidegree) | |
HAOZEE_TEMP_CALIBRATION_ATTR = 0x026D # temperature calibration (decidegree) | |
HAOZEE_TEMP_HYSTERESIS_ATTR = 0x026E # temperature hysteresis (decidegree) | |
HAOZEE_TEMP_PROTECT_HYSTERESIS_ATTR = ( | |
0x026F # temperature hysteresis for protection (decidegree) | |
) | |
HAOZEE_MAX_PROTECT_TEMP_ATTR = ( | |
0x0270 # maximal temp for protection trigger (decidegree) | |
) | |
HAOZEE_MIN_PROTECT_TEMP_ATTR = ( | |
0x0271 # minimal temp for protection trigger (decidegree) | |
) | |
HAOZEE_MAX_TEMP_LIMIT_ATTR = 0x0272 # maximum limit of temperature setting (decidegree) | |
HAOZEE_MIN_TEMP_LIMIT_ATTR = 0x0273 # minimum limit of temperature setting (decidegree) | |
HAOZEE_TARGET_TEMP_ATTR = 0x027E # target temperature (decidegree) | |
HAOZEE_CURRENT_ROOM_TEMP_ATTR = ( | |
0x027F # temperature reported by MCU. Depends on sensor type. (decidegree) | |
) | |
HAOZEE_SENSOR_TYPE_ATTR = 0x0474 # sensor type [0] internal [1] external [2] both | |
HAOZEE_POWERON_BEHAVIOR_ATTR = 0x0475 # poweron behavior [0] restore [1] off [2] on | |
HAOZEE_WEEKFORMAT = 0x0476 # [0] 5+2 [1] 6+1 [2] 7 (days) | |
HAOZEE_CURRENT_MODE_ATTR = 0x0480 # [0] manual [1] auto [2] away | |
HAOZEE_FAULT_ATTR = 0x0582 # Known fault codes: [4] E2 external sensor error | |
#Unknown DP - descaling on/off, window detection, window detection settings | |
_LOGGER = logging.getLogger(__name__) | |
class HY08WEManufCluster(TuyaManufClusterAttributes): | |
"""Manufacturer Specific Cluster of some thermostatic valves.""" | |
# Important! This device uses offset from 2000 year for UTC time and offset from 1970 for local time | |
set_time_offset = 2000 | |
set_time_local_offset = 1970 | |
manufacturer_attributes = { | |
HAOZEE_HEATING_ENABLED_ATTR: ("heating_enabled", t.uint8_t), | |
HAOZEE_MAX_TEMP_PROTECTION_ENABLED_ATTR: ( | |
"max_temp_protection_enabled", | |
t.uint8_t, | |
), | |
HAOZEE_MIN_TEMP_PROTECTION_ENABLED_ATTR: ( | |
"min_temp_protection_enabled", | |
t.uint8_t, | |
), | |
HAOZEE_ENABLED_ATTR: ("enabled", t.uint8_t), | |
HAOZEE_CHILD_LOCK_ATTR: ("child_lock", t.uint8_t), | |
HAOZEE_EXT_TEMP_ATTR: ("external_temperature", t.uint32_t), | |
HAOZEE_AWAY_DAYS_ATTR: ("away_duration_days", t.uint32_t), | |
HAOZEE_AWAY_TEMP_ATTR: ("away_mode_temperature", t.uint32_t), | |
HAOZEE_TEMP_CALIBRATION_ATTR: ("temperature_calibration", t.int32s), | |
HAOZEE_TEMP_HYSTERESIS_ATTR: ("hysterisis_temperature", t.uint32_t), | |
HAOZEE_TEMP_PROTECT_HYSTERESIS_ATTR: ( | |
"hysterisis_protection_temperature", | |
t.uint32_t, | |
), | |
HAOZEE_MAX_PROTECT_TEMP_ATTR: ("max_protection_temperature", t.uint32_t), | |
HAOZEE_MIN_PROTECT_TEMP_ATTR: ("min_protection_temperature", t.uint32_t), | |
HAOZEE_MAX_TEMP_LIMIT_ATTR: ("max_temperature", t.uint32_t), | |
HAOZEE_MIN_TEMP_LIMIT_ATTR: ("min_temperature", t.uint32_t), | |
HAOZEE_TARGET_TEMP_ATTR: ("target_temperature", t.uint32_t), | |
HAOZEE_CURRENT_ROOM_TEMP_ATTR: ("internal_temperature", t.uint32_t), | |
HAOZEE_SENSOR_TYPE_ATTR: ("sensor_settings", t.uint8_t), | |
HAOZEE_POWERON_BEHAVIOR_ATTR: ("poweron_behavior", t.uint8_t), | |
HAOZEE_WEEKFORMAT: ("week_format", t.uint8_t), | |
HAOZEE_CURRENT_MODE_ATTR: ("mode", t.uint8_t), | |
HAOZEE_FAULT_ATTR: ("fault", t.uint8_t), | |
} | |
DIRECT_MAPPED_ATTRS = { | |
HAOZEE_CURRENT_ROOM_TEMP_ATTR: ("local_temp", lambda value: value * 10), | |
HAOZEE_TARGET_TEMP_ATTR: ( | |
"occupied_heating_setpoint", | |
lambda value: value * 10, | |
), | |
HAOZEE_AWAY_TEMP_ATTR: ( | |
"unoccupied_heating_setpoint", | |
lambda value: value * 100, | |
), | |
HAOZEE_TEMP_CALIBRATION_ATTR: ( | |
"local_temperature_calibration", | |
lambda value: value * 10, | |
), | |
HAOZEE_MIN_TEMP_LIMIT_ATTR: ( | |
"min_heat_setpoint_limit", | |
lambda value: value * 100, | |
), | |
HAOZEE_MAX_TEMP_LIMIT_ATTR: ( | |
"max_heat_setpoint_limit", | |
lambda value: value * 100, | |
), | |
HAOZEE_AWAY_DAYS_ATTR: ("unoccupied_duration_days", None), | |
} | |
def _update_attribute(self, attrid, value): | |
super()._update_attribute(attrid, value) | |
if attrid in self.DIRECT_MAPPED_ATTRS: | |
self.endpoint.device.thermostat_bus.listener_event( | |
"temperature_change", | |
self.DIRECT_MAPPED_ATTRS[attrid][0], | |
value | |
if self.DIRECT_MAPPED_ATTRS[attrid][1] is None | |
else self.DIRECT_MAPPED_ATTRS[attrid][1]( | |
value | |
), # decidegree to centidegree | |
) | |
elif attrid == HAOZEE_ENABLED_ATTR: | |
self.endpoint.device.thermostat_bus.listener_event("enabled_change", value) | |
elif attrid == HAOZEE_HEATING_ENABLED_ATTR: | |
self.endpoint.device.thermostat_bus.listener_event("state_change", value) | |
elif attrid == HAOZEE_CURRENT_MODE_ATTR: | |
self.endpoint.device.thermostat_bus.listener_event("mode_change", value) | |
elif attrid == HAOZEE_CHILD_LOCK_ATTR: | |
self.endpoint.device.ui_bus.listener_event("child_lock_change", value) | |
class HY08WEThermostat(TuyaThermostatCluster): | |
"""Thermostat cluster for some thermostatic valves.""" | |
DIRECT_MAPPING_ATTRS = { | |
"occupied_heating_setpoint": ( | |
HAOZEE_TARGET_TEMP_ATTR, | |
lambda value: round(value / 10), | |
), | |
"unoccupied_heating_setpoint": ( | |
HAOZEE_AWAY_TEMP_ATTR, | |
lambda value: round(value / 100), | |
), | |
"min_heat_setpoint_limit": ( | |
HAOZEE_MIN_TEMP_LIMIT_ATTR, | |
lambda value: round(value / 100), | |
), | |
"max_heat_setpoint_limit": ( | |
HAOZEE_MAX_TEMP_LIMIT_ATTR, | |
lambda value: round(value / 100), | |
), | |
"local_temperature_calibration": ( | |
HAOZEE_TEMP_CALIBRATION_ATTR, | |
lambda value: round(value / 10), | |
), | |
} | |
def map_attribute(self, attribute, value): | |
"""Map standardized attribute value to dict of manufacturer values.""" | |
if attribute in self.DIRECT_MAPPING_ATTRS: | |
return { | |
self.DIRECT_MAPPING_ATTRS[attribute][0]: value | |
if self.DIRECT_MAPPING_ATTRS[attribute][1] is None | |
else self.DIRECT_MAPPING_ATTRS[attribute][1](value) | |
} | |
if attribute == "system_mode": | |
if value == self.SystemMode.Off: | |
return {HAOZEE_ENABLED_ATTR: 0} | |
if value == self.SystemMode.Heat: | |
return {HAOZEE_ENABLED_ATTR: 1} | |
self.error("Unsupported value for SystemMode") | |
if attribute == "programing_oper_mode": | |
if value == self.ProgrammingOperationMode.Simple: | |
return {HAOZEE_CURRENT_MODE_ATTR: 0} | |
if value == self.ProgrammingOperationMode.Schedule_programming_mode: | |
return {HAOZEE_CURRENT_MODE_ATTR: 1} | |
if value == self.ProgrammingOperationMode.Economy_mode: | |
return {HAOZEE_CURRENT_MODE_ATTR: 2} | |
self.error("Unsupported value for ProgrammingOperationMode") | |
def mode_change(self, value): | |
"""System Mode change.""" | |
occupancy = self.Occupancy.Occupied | |
if value == 0: | |
prog_mode = self.ProgrammingOperationMode.Simple | |
elif value == 1: | |
prog_mode = self.ProgrammingOperationMode.Schedule_programming_mode | |
elif value == 2: | |
prog_mode = self.ProgrammingOperationMode.Simple | |
occupancy = self.Occupancy.Unoccupied | |
self._update_attribute(self.attridx["programing_oper_mode"], prog_mode) | |
self._update_attribute(self.attridx["occupancy"], occupancy) | |
def enabled_change(self, value): | |
"""System mode change.""" | |
if value == 0: | |
mode = self.SystemMode.Off | |
else: | |
mode = self.SystemMode.Heat | |
self._update_attribute(self.attridx["system_mode"], mode) | |
class HY08WEUserInterface(TuyaUserInterfaceCluster): | |
"""HVAC User interface cluster for tuya electric heating thermostats.""" | |
_CHILD_LOCK_ATTR = HAOZEE_CHILD_LOCK_ATTR | |
class HY08WE(TuyaThermostat): | |
"""Haozee HY08WE Thermostatic radiator valve.""" | |
signature = { | |
# endpoint=1 profile=260 device_type=81 device_version=1 input_clusters=[0, 4, 5, 61184], | |
# output_clusters=[25, 10] | |
MODELS_INFO: [("_TZE200_znzs7yaw", "TS0601")], | |
ENDPOINTS: { | |
1: { | |
PROFILE_ID: zha.PROFILE_ID, | |
DEVICE_TYPE: zha.DeviceType.SMART_PLUG, | |
INPUT_CLUSTERS: [ | |
Basic.cluster_id, | |
Groups.cluster_id, | |
Scenes.cluster_id, | |
TuyaManufClusterAttributes.cluster_id, | |
], | |
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id], | |
} | |
}, | |
} | |
replacement = { | |
ENDPOINTS: { | |
1: { | |
PROFILE_ID: zha.PROFILE_ID, | |
DEVICE_TYPE: zha.DeviceType.THERMOSTAT, | |
INPUT_CLUSTERS: [ | |
Basic.cluster_id, | |
Groups.cluster_id, | |
Scenes.cluster_id, | |
HY08WEManufCluster, | |
HY08WEThermostat, | |
HY08WEUserInterface, | |
], | |
OUTPUT_CLUSTERS: [Ota.cluster_id, Time.cluster_id], | |
} | |
} | |
} |
Sign up for free
to join this conversation on GitHub.
Already have an account?