Script to configure an all flash vsan cluster from scratch.
#Enable All Flash vSAN Intelligently
Import-Module -Name VMware.VimAutomation.Core -ErrorAction SilentlyContinue
$TargetHosts = Get-VMHost
#$ESXCLI = $TargetHosts | Get-EsxCli
#$Storage = $Targethosts | Get-SCSILUN
#$Storage.ScsiLun #List of Vendors and model
$CacheDiskVendor = "SanDisk"
$CacheDiskModel = "LT0400WM"
$CapacityDiskVendor = "SanDisk"
$CapacityDiskModel = "LT0800MO"
#These below numbers are based upon vSAN 6.0 configuration maximums.
$DiskGroupMax = 5
$CapacityDiskMax = 7
#$TargetHBA = "vmhba0"
# Example to tag a flash drive as capacity
#$esxcli.vsan.storage.tag("naa.6000c295be1e7ac4370e6512a0003edf","capacityFlash")
#Creates a disk group w/ two disks and one cache
#$ESXCLI.vsan.storage.add(@("naa.5001e882002837dac","naa.5001e82002837f08"),"naa.5001e82002850250")
<#Creates Disk Groups#>
[System.Collections.ArrayList]$CapacityList = @()
[System.Collections.ArrayList]$CacheList = @()
Foreach ($VMHost in $targethosts)
{
$ESXCLI = $VMHost | Get-ESXCLI
$Storage = $VMhost | Get-SCSILUN
Foreach ($SCSILUN in $Storage)
{
If ($SCSILUN.Vendor -match $CapacityDiskVendor -and $SCSILUN.Model -match $CapacityDiskModel)
{
$CapacityList += $SCSILUN
}
If ($SCSILUN.Vendor -match $CacheDiskVendor -and $SCSILUN.Model -match $CacheDiskModel)
{
$CacheList += $SCSILUN
}
}
If ($CacheList.Count -gt $DiskGroupMax)
{
Write-Host "More than $($DiskGroupMax) Cache Disks were found. Script is exiting. vSAN only supports a max of $($DiskGroupMax) disk groups. This script does not account for setups outside standards and also assumes different models of disks for cache and capacity. Manual setup will be required."
Break
}
$Ratio = ($CapacityList.Count / $CacheList.Count)
If ($Ratio -gt $CapacityDiskMax)
{
Write-Host "More than $($CapacityDiskMax) capacity disks were found per disk group. Script is exiting. vSAN only supports a max of $($CapacityDiskMax) capacity disks per disk group. This script does not account for setups outside standards. Manual setup will be required."
Break
}
}
<# Non-Integer Number Checker #>
If ($Ratio.gettype() -eq [int32])
{
Foreach ($CacheDisk in $CacheList)
{$CapacityDiskList = @()
Foreach ($Disk in ($CapacityList | select -first $Ratio))
{
$ESXCLI.vsan.storage.tag.add($Disk.CanonicalName,"capacityFlash")
$CapacityDiskList += $Disk.CanonicalName
}
$ESXCLI.vsan.storage.add($CapacityDiskList,$CacheDisk.CanonicalName)
$CapacityList.RemoveRange(0,$Ratio)
}
}
<#
In the case where capacity and cache disks are uneven equaling a decimal based ratio,
this will simply make one disk group that has the most capacity disks behind it. Then spread the rest out evenly.
#>
ElseIf ($Ratio.gettype() -eq [double])
{
$Ratio = [math]::ceiling($Ratio)
Foreach ($CacheDisk in $CacheList)
{
$CapacityDiskList = @()
Foreach ($Disk in ($CapacityList | select -first $Ratio))
{
$ESXCLI.vsan.storage.tag.add($Disk.CanonicalName,"capacityFlash")
$CapacityDiskList += $Disk.CanonicalName
}
$ESXCLI.vsan.storage.add($CapacityDiskList,$CacheDisk.CanonicalName)
$CapacityList.RemoveRange(0,$Ratio)
$CacheList.Remove($CacheDisk)
$Ratio = ($CapacityList.count / $CacheList.count)
}
}
}