Zabbix SNMP monitoring template for DELL Openmanage Server Administrator
<?xml version="1.0" encoding="UTF-8"?>
<zabbix_export>
<version>2.0</version>
<date>2014-06-18T02:56:36Z</date>
<groups>
<group>
<name>Templates</name>
</group>
</groups>
<templates>
<template>
<template>Template SNMP DELL OpenManage</template>
<name>Template SNMP DELL OpenManage</name>
<groups>
<group>
<name>Templates</name>
</group>
</groups>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<items>
<item>
<name>OM: Chassis Express Service Code Name</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.300.10.1.49.1</snmp_oid>
<key>chassisExpressServiceCodeName</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>1</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>This attribute defines the express service code of the system.</description>
<inventory_link>9</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap/>
</item>
<item>
<name>OM: Chassis Intrusion Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.30.1</snmp_oid>
<key>systemStateChassisIntrusionStatusCombined</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the intrusion status of all intrusion detection devices in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Chassis Model Name</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.300.10.1.9.1</snmp_oid>
<key>chassisModelName</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>1</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the system model type for this chassis.</description>
<inventory_link>29</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap/>
</item>
<item>
<name>OM: Chassis Service Tag NameName</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.300.10.1.11.1</snmp_oid>
<key>chassisServiceTagName</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>1</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the service tag name for this chassis.</description>
<inventory_link>8</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap/>
</item>
<item>
<name>OM: Chassis Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.4.1</snmp_oid>
<key>systemStateChassisStatus</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the system status of this chassis.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Event Log Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.41.1</snmp_oid>
<key>systemStateEventLogStatus</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the overall status of this chassis (ESM) event log.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Fan Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.21.1</snmp_oid>
<key>systemStateCoolingDeviceStatusCombined</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>This attribute defines the cooling device status of all cooling devices in this chassis. The results is returned as a combined status value. The value has the same definition type as DellStatus.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Fan Unit Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.44.1</snmp_oid>
<key>systemStateCoolingUnitStatusCombined</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the combined status of all cooling units of this chassis.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Global System Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.2.1</snmp_oid>
<key>systemStateGlobalSystemStatus</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the global system status of all chassis being monitored by this instrumentation instance.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Memory Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.27.1</snmp_oid>
<key>systemStateMemoryDeviceStatusCombined</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the status of all memory devices in this chassis.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Power Supply Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.9.1</snmp_oid>
<key>systemStatePowerSupplyStatusCombined</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the status of all power supplies in this chassis.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Processor Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.50.1</snmp_oid>
<key>systemStateProcessorDeviceStatusCombined</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the combined status of all processor devices of this chassis.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Temperature Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.24.1</snmp_oid>
<key>systemStateTemperatureStatusCombined</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the status of all temperature probes in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
<item>
<name>OM: Voltage Status</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.200.10.1.12.1</snmp_oid>
<key>systemStateVoltageStatusCombined</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description/>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item>
</items>
<discovery_rules>
<discovery_rule>
<name>OM: Discovery arrayDisk</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.130.4.1.2</snmp_oid>
<key>arrayDisk.discovery</key>
<delay>3600</delay>
<status>0</status>
<allowed_hosts/>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<delay_flex/>
<params/>
<ipmi_sensor/>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<filter>:</filter>
<lifetime>7</lifetime>
<description>Identifies the current state of the array disk.</description>
<item_prototypes>
<item_prototype>
<name>OM: Array Disk Smart Alert Indication ({#SNMPVALUE})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.130.4.1.31.{#SNMPINDEX}</snmp_oid>
<key>arrayDiskSmartAlertIndication[{#SNMPVALUE}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Indicates whether the disk has received a predictive failure.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage arrayDiskSmartAlertIndication</name>
</valuemap>
</item_prototype>
<item_prototype>
<name>OM: Array Disk State ({#SNMPVALUE})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.130.4.1.4.{#SNMPINDEX}</snmp_oid>
<key>arrayDiskState[{#SNMPVALUE}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Identifies the current state of the array disk.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage arrayDiskState</name>
</valuemap>
</item_prototype>
</item_prototypes>
<trigger_prototypes>
<trigger_prototype>
<expression>{Template SNMP DELL OpenManage:arrayDiskState[{#SNMPVALUE}].last()}#3 &amp; {Template SNMP DELL OpenManage:arrayDiskState[{#SNMPVALUE}].last()}#1</expression>
<name>DELL OMSA: pdisk({#SNMPVALUE}) is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
</trigger_prototype>
<trigger_prototype>
<expression>{Template SNMP DELL OpenManage:arrayDiskSmartAlertIndication[{#SNMPVALUE}].last()}#1</expression>
<name>DELL OMSA: Predictive failure detected on {#SNMPVALUE}</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
</trigger_prototype>
</trigger_prototypes>
<graph_prototypes/>
<host_prototypes/>
</discovery_rule>
<discovery_rule>
<name>OM: Discovery controllerRollUpStatus</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.130.1.1.37</snmp_oid>
<key>controllerRollUpStatus.discovery</key>
<delay>3600</delay>
<status>0</status>
<allowed_hosts/>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<delay_flex/>
<params/>
<ipmi_sensor/>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<filter>:</filter>
<lifetime>7</lifetime>
<description>Indicates severity of the controller state. This is the combined status of the controller and its components.</description>
<item_prototypes>
<item_prototype>
<name>OM: Controller Roll-Up Status {#SNMPINDEX}</name>
<type>4</type>
<snmp_community>public</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.130.1.1.37.{#SNMPINDEX}</snmp_oid>
<key>controllerRollUpStatus[{#SNMPINDEX}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Indicates severity of the controller state. This is the combined status of the controller and its components.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item_prototype>
</item_prototypes>
<trigger_prototypes>
<trigger_prototype>
<expression>{Template SNMP DELL OpenManage:controllerRollUpStatus[{#SNMPINDEX}].last()}&gt;4</expression>
<name>DELL OMSA: RAID controller is Error on instance {#SNMPINDEX}</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
</trigger_prototype>
</trigger_prototypes>
<graph_prototypes/>
<host_prototypes/>
</discovery_rule>
<discovery_rule>
<name>OM: Discovery memoryDeviceStatus</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.1100.50.1.8.1</snmp_oid>
<key>memoryDeviceStatus.discovery</key>
<delay>3600</delay>
<status>0</status>
<allowed_hosts/>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<delay_flex/>
<params/>
<ipmi_sensor/>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<filter>:</filter>
<lifetime>7</lifetime>
<description>Identifies the status of the memory device.</description>
<item_prototypes>
<item_prototype>
<name>OM: Memory Device Status ({#SNMPVALUE})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.1100.50.1.5.1.{#SNMPINDEX}</snmp_oid>
<key>memoryDeviceStatus[{#SNMPVALUE}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the status of the memory device.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item_prototype>
</item_prototypes>
<trigger_prototypes>
<trigger_prototype>
<expression>{Template SNMP DELL OpenManage:memoryDeviceStatus[{#SNMPVALUE}].last()}&gt;4</expression>
<name>DELL OMSA: Memory Device({#SNMPVALUE}) is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
</trigger_prototype>
</trigger_prototypes>
<graph_prototypes/>
<host_prototypes/>
</discovery_rule>
<discovery_rule>
<name>OM: Discovery processorDeviceStatus</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.1100.30.1.5.1</snmp_oid>
<key>processorDeviceStatus.discovery</key>
<delay>3600</delay>
<status>0</status>
<allowed_hosts/>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<delay_flex/>
<params/>
<ipmi_sensor/>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<filter>:</filter>
<lifetime>7</lifetime>
<description>Indicates the status of the processor device.</description>
<item_prototypes>
<item_prototype>
<name>OM: processorDeviceStatus ({#SNMPINDEX})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10892.1.1100.30.1.5.1.{#SNMPINDEX}</snmp_oid>
<key>processorDeviceStatus[{#SNMPINDEX}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Defines the status of the processor device.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item_prototype>
</item_prototypes>
<trigger_prototypes>
<trigger_prototype>
<expression>{Template SNMP DELL OpenManage:processorDeviceStatus[{#SNMPINDEX}].last()}&gt;4</expression>
<name>DELL OMSA: Processor Device is Error on instance {#SNMPINDEX}</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
</trigger_prototype>
</trigger_prototypes>
<graph_prototypes/>
<host_prototypes/>
</discovery_rule>
<discovery_rule>
<name>OM: Discovery Storage batteryRollUpStatus</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.130.15.1.2</snmp_oid>
<key>batteryRollUpStatus.discovery</key>
<delay>3600</delay>
<status>0</status>
<allowed_hosts/>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<delay_flex/>
<params/>
<ipmi_sensor/>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<filter>:</filter>
<lifetime>7</lifetime>
<description>Severity of the battery state. This is the combined status of the battery and its components.</description>
<item_prototypes>
<item_prototype>
<name>OM: Storage Battery Roll-Up Status ({#SNMPVALUE})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.130.15.1.5.{#SNMPINDEX}</snmp_oid>
<key>batteryRollUpStatus[{#SNMPINDEX}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Severity of the battery state. This is the combined status of the battery and its components.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage System Status</name>
</valuemap>
</item_prototype>
</item_prototypes>
<trigger_prototypes>
<trigger_prototype>
<expression>{Template SNMP DELL OpenManage:batteryRollUpStatus[{#SNMPINDEX}].last()}#3 &amp; {Template SNMP DELL OpenManage:batteryRollUpStatus[{#SNMPINDEX}].last()}#4</expression>
<name>DELL OMSA: RAID Battery({#SNMPVALUE}) is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
</trigger_prototype>
</trigger_prototypes>
<graph_prototypes/>
<host_prototypes/>
</discovery_rule>
<discovery_rule>
<name>OM: Discovery virtualDisk</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.140.1.1.2</snmp_oid>
<key>virtualDisk.discovery</key>
<delay>3600</delay>
<status>0</status>
<allowed_hosts/>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<delay_flex/>
<params/>
<ipmi_sensor/>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<filter>:</filter>
<lifetime>7</lifetime>
<description>Identifies the current state of this virtual disk.</description>
<item_prototypes>
<item_prototype>
<name>OM: Virtual Disk Layout ({#SNMPVALUE})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.140.1.1.13.{#SNMPINDEX}</snmp_oid>
<key>virtualDiskLayout[{#SNMPVALUE}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Indicates the virtual disk's RAID type. Possible values.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage virtualDiskLayout</name>
</valuemap>
</item_prototype>
<item_prototype>
<name>OM: Virtual Disk Read Policy ({#SNMPVALUE})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.140.1.1.11.{#SNMPINDEX}</snmp_oid>
<key>virtualDiskReadPolicy[{#SNMPVALUE}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Indicates whether the controller's read cache are used when reading from a virtual disk.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage virtualDiskReadPolicy</name>
</valuemap>
</item_prototype>
<item_prototype>
<name>OM: Virtual Disk State ({#SNMPVALUE})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.140.1.1.4.{#SNMPINDEX}</snmp_oid>
<key>virtualDiskState[{#SNMPVALUE}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Identifies the current state of this virtual disk.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage virtualDiskState</name>
</valuemap>
</item_prototype>
<item_prototype>
<name>OM: Virtual Disk Write Policy ({#SNMPVALUE})</name>
<type>4</type>
<snmp_community>{$SNMP_COMMUNITY}</snmp_community>
<multiplier>0</multiplier>
<snmp_oid>.1.3.6.1.4.1.674.10893.1.20.140.1.1.10.{#SNMPINDEX}</snmp_oid>
<key>virtualDiskWritePolicy[{#SNMPVALUE}]</key>
<delay>300</delay>
<history>7</history>
<trends>365</trends>
<status>0</status>
<value_type>3</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port>161</port>
<description>Indicates whether the controller's write cache are used when writing to a virtual disk.</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>DELL Hardware</name>
</application>
</applications>
<valuemap>
<name>Dell Open Manage virtualDiskWritePolicy</name>
</valuemap>
</item_prototype>
</item_prototypes>
<trigger_prototypes>
<trigger_prototype>
<expression>{Template SNMP DELL OpenManage:virtualDiskState[{#SNMPVALUE}].last()}#1</expression>
<name>DELL OMSA: vdisk({#SNMPVALUE}) is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
</trigger_prototype>
</trigger_prototypes>
<graph_prototypes/>
<host_prototypes/>
</discovery_rule>
</discovery_rules>
<macros/>
<templates/>
<screens/>
</template>
</templates>
<triggers>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateChassisIntrusionStatusCombined.last(0)}&gt;4</expression>
<name>DELL OMSA: Chassis Intrusion detected</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateChassisStatus.last(0)}&gt;4</expression>
<name>DELL OMSA: Chassis Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateEventLogStatus.last(0)}&gt;4</expression>
<name>DELL OMSA: Event Log Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateCoolingDeviceStatusCombined.last(0)}&gt;4</expression>
<name>DELL OMSA: Fan Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateCoolingUnitStatusCombined.last(0)}&gt;4</expression>
<name>DELL OMSA: Fan Unit Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateGlobalSystemStatus.last(0)}&gt;4</expression>
<name>DELL OMSA: Global System Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateMemoryDeviceStatusCombined.last(0)}&gt;4</expression>
<name>DELL OMSA: Memory Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStatePowerSupplyStatusCombined.last(0)}&gt;4</expression>
<name>DELL OMSA: Power Supply Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateProcessorDeviceStatusCombined.last(0)}&gt;4</expression>
<name>DELL OMSA: Processor Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateTemperatureStatusCombined.last(0)}&gt;4</expression>
<name>DELL OMSA: Temperature Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
<trigger>
<expression>{Template SNMP DELL OpenManage:systemStateVoltageStatusCombined.last(0)}&gt;4</expression>
<name>DELL OMSA: Voltage Status is Error</name>
<url/>
<status>0</status>
<priority>2</priority>
<description/>
<type>0</type>
<dependencies/>
</trigger>
</triggers>
</zabbix_export>
@complexplans
Copy link

This looks great, but when I attempt to import into Zabbix 2.2 I get the following error:
Cannot find value map "Dell Open Manage arrayDiskSmartAlertIndication" used for item prototype "OM: Array Disk Smart Alert Indication ({#SNMPVALUE})" of discovery rule "OM: Discovery arrayDisk" on "Template SNMP DELL OpenManage".

Any insight? I think I might just need all your value map settings.

@dbarnes69
Copy link

I had to go thru the OMSA SNMP Ref Guide to get the values. Quite the pain to say the least. Not sure if I can export the values I have now, or even how to export them. If need be, I can probably grab a couple of screen shots tho.....

@DavBE
Copy link

DavBE commented Oct 20, 2014

For the noobs like me out there that might get lost here : go to Administration / General. In the dropdown, select "Value Mapping". Add these mappings :

Dell Open Manage arrayDiskSmartAlertIndication
1 ⇒ No
2 ⇒ Yes

Dell Open Manage arrayDiskState
0 ⇒ Unknown
1 ⇒ Ready
2 ⇒ Failed
3 ⇒ Online
4 ⇒ Offline
6 ⇒ Degraded
7 ⇒ Recovering
11 ⇒ Removed
13 ⇒ Non-RAID
14 ⇒ Not Ready
15 ⇒ Resynching
22 ⇒ Replacing
24 ⇒ Rebuild
25 ⇒ No Media
26 ⇒ Formatting
28 ⇒ Diagnostics
34 ⇒ Predictive Failure
35 ⇒ Initializing
39 ⇒ Foreign
40 ⇒ Clear
41 ⇒ Unsupported
53 ⇒ Incompatible
56 ⇒ Read Only

Dell Open Manage System Status
1 ⇒ Other
2 ⇒ Unknown
3 ⇒ OK
4 ⇒ NonCritical
5 ⇒ Critical
6 ⇒ NonRecoverable

Dell Open Manage virtualDiskLayout
1 ⇒ Concatenated
2 ⇒ RAID-0
3 ⇒ RAID-1
7 ⇒ RAID-5
8 ⇒ RAID-6
10 ⇒ RAID-10
12 ⇒ RAID-50
19 ⇒ Concatenated RAID 1
24 ⇒ RAID-60
25 ⇒ CacheCade

Dell Open Manage virtualDiskReadPolicy
1 ⇒ Enabled
2 ⇒ Disabled
3 ⇒ LSI Read Ahead
4 ⇒ LSI Adaptive Read Ahead
5 ⇒ LSI No Read Ahead
9 ⇒ Not Applicable

Dell Open Manage virtualDiskState
0 ⇒ Unknown
1 ⇒ Ready
2 ⇒ Failed
3 ⇒ Online
4 ⇒ Offline
6 ⇒ Degraded
15 ⇒ Resynching
16 ⇒ Regenerating
24 ⇒ Rebuilding
26 ⇒ Formatting
32 ⇒ Reconstructing
35 ⇒ Initializing
36 ⇒ Background Initialization
38 ⇒ Resynching Paused
52 ⇒ Permanently Degraded
54 ⇒ Degraded Redundancy

Dell Open Manage virtualDiskWritePolicy
1 ⇒ Enabled
2 ⇒ Disabled
3 ⇒ LSI Write Back
4 ⇒ LSI Write Through
5 ⇒ Enabled Always (Adaptec only)
6 ⇒ Enabled Always (SAS only)
9 ⇒ Not Applicable

@kebueno
Copy link

kebueno commented Sep 10, 2015

Hello
I'm with this problem

my zabbix server is in version 2.4

became not supported: SNMP error: (noSuchName) There is no such variable name in this MIB.

@GOID1989
Copy link

I think here:
OM: Controller Roll-Up Status {#SNMPINDEX} need change snmp_community to {$SNMP_COMMUNITY}

@elupus
Copy link

elupus commented Feb 9, 2016

Here's the value map's so nobody else need to do it manually :)

<?xml version="1.0" encoding="UTF-8"?>
<zabbix_export>
    <version>3.0</version>
    <date>2016-02-09T18:46:16Z</date>
    <value_maps>
        <value_map>
            <name>Dell Open Manage arrayDiskSmartAlertIndication</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>No</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Yes</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>Dell Open Manage arrayDiskState</name>
            <mappings>
                <mapping>
                    <value>0</value>
                    <newvalue>Unknown</newvalue>
                </mapping>
                <mapping>
                    <value>1</value>
                    <newvalue>Ready</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Failed</newvalue>
                </mapping>
                <mapping>
                    <value>3</value>
                    <newvalue>Online</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Offline</newvalue>
                </mapping>
                <mapping>
                    <value>6</value>
                    <newvalue>Degraded</newvalue>
                </mapping>
                <mapping>
                    <value>7</value>
                    <newvalue>Recovering</newvalue>
                </mapping>
                <mapping>
                    <value>11</value>
                    <newvalue>Removed</newvalue>
                </mapping>
                <mapping>
                    <value>13</value>
                    <newvalue>Non-RAID</newvalue>
                </mapping>
                <mapping>
                    <value>14</value>
                    <newvalue>Not Ready</newvalue>
                </mapping>
                <mapping>
                    <value>15</value>
                    <newvalue>Resynching</newvalue>
                </mapping>
                <mapping>
                    <value>22</value>
                    <newvalue>Replacing</newvalue>
                </mapping>
                <mapping>
                    <value>24</value>
                    <newvalue>Rebuild</newvalue>
                </mapping>
                <mapping>
                    <value>25</value>
                    <newvalue>No Media</newvalue>
                </mapping>
                <mapping>
                    <value>26</value>
                    <newvalue>Formatting</newvalue>
                </mapping>
                <mapping>
                    <value>28</value>
                    <newvalue>Diagnostics</newvalue>
                </mapping>
                <mapping>
                    <value>34</value>
                    <newvalue>Predictive Failure</newvalue>
                </mapping>
                <mapping>
                    <value>35</value>
                    <newvalue>Initializing</newvalue>
                </mapping>
                <mapping>
                    <value>39</value>
                    <newvalue>Foreign</newvalue>
                </mapping>
                <mapping>
                    <value>40</value>
                    <newvalue>Clear</newvalue>
                </mapping>
                <mapping>
                    <value>41</value>
                    <newvalue>Unsupported</newvalue>
                </mapping>
                <mapping>
                    <value>53</value>
                    <newvalue>Incompatible</newvalue>
                </mapping>
                <mapping>
                    <value>56</value>
                    <newvalue>Read Only</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>Dell Open Manage System Status</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Other</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Unknown</newvalue>
                </mapping>
                <mapping>
                    <value>3</value>
                    <newvalue>OK</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>NonCritical</newvalue>
                </mapping>
                <mapping>
                    <value>5</value>
                    <newvalue>Critical</newvalue>
                </mapping>
                <mapping>
                    <value>6</value>
                    <newvalue>NonRecoverable</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>Dell Open Manage virtualDiskLayout</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Concatenated</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>RAID-0</newvalue>
                </mapping>
                <mapping>
                    <value>3</value>
                    <newvalue>RAID-1</newvalue>
                </mapping>
                <mapping>
                    <value>7</value>
                    <newvalue>RAID-5</newvalue>
                </mapping>
                <mapping>
                    <value>8</value>
                    <newvalue>RAID-6</newvalue>
                </mapping>
                <mapping>
                    <value>10</value>
                    <newvalue>RAID-10</newvalue>
                </mapping>
                <mapping>
                    <value>12</value>
                    <newvalue>RAID-50</newvalue>
                </mapping>
                <mapping>
                    <value>19</value>
                    <newvalue>Concatenated RAID-1</newvalue>
                </mapping>
                <mapping>
                    <value>24</value>
                    <newvalue>RAID-60</newvalue>
                </mapping>
                <mapping>
                    <value>25</value>
                    <newvalue>CacheCade</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>Dell Open Manage virtualDiskReadPolicy</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Enabled</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Disabled</newvalue>
                </mapping>
                <mapping>
                    <value>3</value>
                    <newvalue>LSI Read Ahead</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>LSI Adaptive Read Ahead</newvalue>
                </mapping>
                <mapping>
                    <value>5</value>
                    <newvalue>LSI No Read Ahead</newvalue>
                </mapping>
                <mapping>
                    <value>9</value>
                    <newvalue>Not Applicable</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>Dell Open Manage virtualDiskState</name>
            <mappings>
                <mapping>
                    <value>0</value>
                    <newvalue>Unknown</newvalue>
                </mapping>
                <mapping>
                    <value>1</value>
                    <newvalue>Ready</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Failed</newvalue>
                </mapping>
                <mapping>
                    <value>3</value>
                    <newvalue>Online</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>Offline</newvalue>
                </mapping>
                <mapping>
                    <value>6</value>
                    <newvalue>Degraded</newvalue>
                </mapping>
                <mapping>
                    <value>15</value>
                    <newvalue>Resynching</newvalue>
                </mapping>
                <mapping>
                    <value>16</value>
                    <newvalue>Regenerating</newvalue>
                </mapping>
                <mapping>
                    <value>24</value>
                    <newvalue>Rebuilding</newvalue>
                </mapping>
                <mapping>
                    <value>26</value>
                    <newvalue>Formatting</newvalue>
                </mapping>
                <mapping>
                    <value>32</value>
                    <newvalue>Reconstructing</newvalue>
                </mapping>
                <mapping>
                    <value>35</value>
                    <newvalue>Initializing</newvalue>
                </mapping>
                <mapping>
                    <value>36</value>
                    <newvalue>Background Initialization</newvalue>
                </mapping>
                <mapping>
                    <value>38</value>
                    <newvalue>Resynching Paused</newvalue>
                </mapping>
                <mapping>
                    <value>52</value>
                    <newvalue>Permanently Degraded</newvalue>
                </mapping>
                <mapping>
                    <value>54</value>
                    <newvalue>Degraded Redundancy</newvalue>
                </mapping>
            </mappings>
        </value_map>
        <value_map>
            <name>Dell Open Manage virtualDiskWritePolicy</name>
            <mappings>
                <mapping>
                    <value>1</value>
                    <newvalue>Enabled</newvalue>
                </mapping>
                <mapping>
                    <value>2</value>
                    <newvalue>Disabled</newvalue>
                </mapping>
                <mapping>
                    <value>3</value>
                    <newvalue>LSI Write Back</newvalue>
                </mapping>
                <mapping>
                    <value>4</value>
                    <newvalue>LSI Write Through</newvalue>
                </mapping>
                <mapping>
                    <value>5</value>
                    <newvalue>Enabled Always (Adaptec only)</newvalue>
                </mapping>
                <mapping>
                    <value>6</value>
                    <newvalue>Enabled Always (SAS only)</newvalue>
                </mapping>
                <mapping>
                    <value>9</value>
                    <newvalue>Not Applicable</newvalue>
                </mapping>
            </mappings>
        </value_map>
    </value_maps>
</zabbix_export>

@oleksii-kalinin
Copy link

When i try to import this gist i have an error: Cannot find value map "Dell Open Manage arrayDiskSmartAlertIndication" used for item prototype "OM: Array Disk Smart Alert Indication ({#SNMPVALUE})" of discovery rule "OM: Discovery arrayDisk" on "Template SNMP DELL OpenManage". How i can solve this problem?

@michalzubkowicz
Copy link

@Kaliha - You have to create (in 2.x) / import (in 3.0) value mappings in Configration -> General, provided by @elupus (btw thanks @elupus! You, saved my day ;))

@philip-holmgren
Copy link

Hi. First of all thanks for providing all this!
After importing the template and name mapping I tried add the template to an SNMP client. For all the items in the template if get "No such object available on this agent on this OID".

The server I'm trying to get info from is a PowerEdgeR620; OS: Ubuntu 14.04; installed: Dell OMSA (7.4).
Just want to mention I'm an utter noob if it comes to SNMP. I have set the SNMPcommunity on the agent and in zabbix server and tested the connection with snmpwalk. These OID's are they hardware specific? Or does someone have an idea what I'm doing wrong here

@philip-holmgren
Copy link

Never mind my last comment, I needed to make a change to my snmpd settings.

I did found out that the above template needs a change to be compatible with Zabbix 3 for the discovery rules.
The SNMP OID have a different structure: it changed from ".1.3.6.1.4.1.674.10893.1.20.140.1.1.2" to "discovery[{#SNMPVALUE},.1.3.6.1.4.1.674.10893.1.20.140.1.1.2]"

@NoToR1OuS
Copy link

Okay, this is fantastic and exactly what I am looking for. I am running Dell OMSA 7.3 on Citrix Xenserver 6.5 and running Zabbix 3.0. I can see all of the disk statuses via the web UI and when I imported the value maps, that @elupus so graciously provided, and imported the template successfully. I am getting an error on the disk array, and disks and all that jazz within the discovery rules.

Here is what the discovery rules look like within the host which I am using. I have also verified that the host is listening on port 161 and I can walk the defined MIBs in the discovery rules.

us7fcim 1

[ ~]$ snmpwalk -v2c -c public 10.2.0.120 .1.3.6.1.4.1.674.10893.1.20.130.4.1.2
SNMPv2-SMI::enterprises.674.10893.1.20.130.4.1.2.1 = STRING: "Physical Disk 0:0:0"
SNMPv2-SMI::enterprises.674.10893.1.20.130.4.1.2.2 = STRING: "Physical Disk 0:0:1"
SNMPv2-SMI::enterprises.674.10893.1.20.130.4.1.2.3 = STRING: "Physical Disk 0:0:2"
SNMPv2-SMI::enterprises.674.10893.1.20.130.4.1.2.4 = STRING: "Physical Disk 0:0:3"
SNMPv2-SMI::enterprises.674.10893.1.20.130.4.1.2.5 = STRING: "Physical Disk 1:0:4"
SNMPv2-SMI::enterprises.674.10893.1.20.130.4.1.2.6 = STRING: "Physical Disk 1:0:5"
SNMPv2-SMI::enterprises.674.10893.1.20.130.4.1.2.7 = STRING: "Physical Disk 1:0:6"
SNMPv2-SMI::enterprises.674.10893.1.20.130.4.1.2.8 = STRING: "Physical Disk 1:0:7"
[ ~]$

I attempted to change the setting @colicab suggested but it broke the import of the template, I may just be changing the OID in the incorrect place and I will be the first to admit that I am still not 100% sure how the SNMP magic works within Zabbix.

Any help would be greatly appreciated!

Thank you,

@duporte
Copy link

duporte commented Jul 5, 2016

NoToR1OuS, have you solved your problem with Invalid SNMP OID ? I'm experiencing the same issue...

@tplawczyk
Copy link

Did you resolved this issue, because I also have a problem with that?

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment