discovery_switch_debug.out
LibreNMS Discovery
SQL[select `migration` from `migrations` order by `id` desc limit 1 [] 178.84ms]
SQL[select count(*) as aggregate from `migrations` limit 1 [] 207.35ms]
SQL[SELECT version() [] 195.67ms]
===================================
Version info:
Commit SHA: 5c6a9ab623aa913f892038d547ff32f725ed1fa8
Commit Date: 1556573781
DB Schema: 2019_02_10_220000_add_dates_to_fdb (132)
PHP: 7.1.28-1+0~20190412071216.17+stretch~1.gbpbe9b36
MySQL: 10.1.37-MariaDB-0+deb9u1
RRDTool: 1.6.0
SNMP: NET-SNMP 5.7.3
==================================DEBUG!
Updating os_def.cache...
Done
Override discovery modules: sensors, os
SQL[SELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `device_id` = '55' AND poller_group IN(3) ORDER BY device_id DESC [] 167.92ms]
SQL[SELECT * FROM devices_attribs WHERE `device_id` = ? [55] 191.81ms]
switch.hostname 55 powerconnect [FPING] /usr/bin/fping -e -q -c 3 -p 500 -t 500 switch.hostname
array (
'xmt' => '3',
'rcv' => '3',
'loss' => '0',
'min' => '1.23',
'max' => '1.31',
'avg' => '1.26',
'exitcode' => 0,
)
SQL[INSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`,`debug`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW(),:debug) {"xmt":"3","rcv":"3","loss":"0","min":"1.23","max":"1.31","avg":"1.26","device_id":55,"debug":"[]"} 171.13ms]
SNMP Check response code: 0
SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [55,"poll_mib"] 185.56ms]
Attempting to initialize OS: powerconnect
OS initialized: LibreNMS\OS\Powerconnect
Modules status: Global+
OS
Device
#### Load disco module core ####
SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQn' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'sysName.0' 'sysObjectID.0' 'sysDescr.0']
.*.*.0 = SWITCH-NAME
.*.*.0 = .*.4.1.674.10895.3031
.*.*.0 = 48G Ethernet Switch
>> Runtime for discovery module 'core': 0.1410 seconds with 976 bytes
>> SNMP: [2/0.28s] MySQL: [4/0.72s] RRD: [0/0.00s]
#### Unload disco module core ####
Modules status: Global+
OS+
Device
#### Load disco module sensors ####
ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'entPhysicalDescr']
entPhysicalDescr.64 = Stack
entPhysicalDescr.67108992 = PowerConnect 5548
entPhysicalDescr.67109185 = PowerSupply
entPhysicalDescr.67109249 = Fan
entPhysicalDescr.67109250 = Fan
entPhysicalDescr.68157952 = Slot
entPhysicalDescr.68420352 = PowerConnect 5548
entPhysicalDescr.68420481 = Thermal Sensor
entPhysicalDescr.68424704 = GT_98DX4122
entPhysicalDescr.68424769 =
entPhysicalDescr.68424770 =
entPhysicalDescr.68424771 =
entPhysicalDescr.68424772 =
entPhysicalDescr.68424773 =
entPhysicalDescr.68424774 =
entPhysicalDescr.68424775 =
entPhysicalDescr.68424776 =
entPhysicalDescr.68424777 =
entPhysicalDescr.68424778 =
entPhysicalDescr.68424779 =
entPhysicalDescr.68424780 =
entPhysicalDescr.68424781 =
entPhysicalDescr.68424782 =
entPhysicalDescr.68424783 =
entPhysicalDescr.68424784 =
entPhysicalDescr.68424785 =
entPhysicalDescr.68424786 =
entPhysicalDescr.68424787 =
entPhysicalDescr.68424788 =
entPhysicalDescr.68424789 =
entPhysicalDescr.68424790 =
entPhysicalDescr.68424791 =
entPhysicalDescr.68424792 =
entPhysicalDescr.68428800 = GT_98DX4123
entPhysicalDescr.68428865 =
entPhysicalDescr.68428866 =
entPhysicalDescr.68428867 =
entPhysicalDescr.68428868 =
entPhysicalDescr.68428869 =
entPhysicalDescr.68428870 =
entPhysicalDescr.68428871 =
entPhysicalDescr.68428872 =
entPhysicalDescr.68428873 =
entPhysicalDescr.68428874 =
entPhysicalDescr.68428875 =
entPhysicalDescr.68428876 =
entPhysicalDescr.68428877 =
entPhysicalDescr.68428878 =
entPhysicalDescr.68428879 =
entPhysicalDescr.68428880 =
entPhysicalDescr.68428881 =
entPhysicalDescr.68428882 =
entPhysicalDescr.68428883 =
entPhysicalDescr.68428884 =
entPhysicalDescr.68428885 =
entPhysicalDescr.68428886 =
entPhysicalDescr.68428887 =
entPhysicalDescr.68428888 =
entPhysicalDescr.68428889 =
entPhysicalDescr.68428890 =
entPhysicalDescr.134217856 = PowerConnect 5548
entPhysicalDescr.201326720 = PowerConnect 5548
entPhysicalDescr.268435584 = PowerConnect 5548
entPhysicalDescr.335544448 = PowerConnect 5548
entPhysicalDescr.402653312 = PowerConnect 5548
entPhysicalDescr.469762176 = PowerConnect 5548
entPhysicalDescr.536871040 = PowerConnect 5548
entPhysicalNameSNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'entPhysicalName']
entPhysicalName.64 = Stack
entPhysicalName.67108992 =
entPhysicalName.67109185 = Main PowerSupply
entPhysicalName.67109249 = Fan1
entPhysicalName.67109250 = Fan2
entPhysicalName.68157952 = Slot
entPhysicalName.68420352 = PowerConnect 5548
entPhysicalName.68420481 =
entPhysicalName.68424704 = GT_98DX4122
entPhysicalName.68424769 =
entPhysicalName.68424770 =
entPhysicalName.68424771 =
entPhysicalName.68424772 =
entPhysicalName.68424773 =
entPhysicalName.68424774 =
entPhysicalName.68424775 =
entPhysicalName.68424776 =
entPhysicalName.68424777 =
entPhysicalName.68424778 =
entPhysicalName.68424779 =
entPhysicalName.68424780 =
entPhysicalName.68424781 =
entPhysicalName.68424782 =
entPhysicalName.68424783 =
entPhysicalName.68424784 =
entPhysicalName.68424785 =
entPhysicalName.68424786 =
entPhysicalName.68424787 =
entPhysicalName.68424788 =
entPhysicalName.68424789 =
entPhysicalName.68424790 =
entPhysicalName.68424791 =
entPhysicalName.68424792 =
entPhysicalName.68428800 = GT_98DX4123
entPhysicalName.68428865 =
entPhysicalName.68428866 =
entPhysicalName.68428867 =
entPhysicalName.68428868 =
entPhysicalName.68428869 =
entPhysicalName.68428870 =
entPhysicalName.68428871 =
entPhysicalName.68428872 =
entPhysicalName.68428873 =
entPhysicalName.68428874 =
entPhysicalName.68428875 =
entPhysicalName.68428876 =
entPhysicalName.68428877 =
entPhysicalName.68428878 =
entPhysicalName.68428879 =
entPhysicalName.68428880 =
entPhysicalName.68428881 =
entPhysicalName.68428882 =
entPhysicalName.68428883 =
entPhysicalName.68428884 =
entPhysicalName.68428885 =
entPhysicalName.68428886 =
entPhysicalName.68428887 =
entPhysicalName.68428888 =
entPhysicalName.68428889 =
entPhysicalName.68428890 =
entPhysicalName.134217856 =
entPhysicalName.201326720 =
entPhysicalName.268435584 =
entPhysicalName.335544448 =
entPhysicalName.402653312 =
entPhysicalName.469762176 =
entPhysicalName.536871040 =
entPhySensorTypeSNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'entPhySensorType']
entPhySensorType = No Such Object available on this agent at this OID
entPhySensorScaleSNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'entPhySensorScale']
entPhySensorScale = No Such Object available on this agent at this OID
entPhySensorPrecisionSNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'entPhySensorPrecision']
entPhySensorPrecision = No Such Object available on this agent at this OID
entPhySensorValueSNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'entPhySensorValue']
entPhySensorValue = No Such Object available on this agent at this OID
entPhySensorOperStatusSNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'entPhySensorOperStatus']
entPhySensorOperStatus = No Such Object available on this agent at this OID
SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [55,"ipmi_hostname"] 221.83ms]
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",55,"ipmi"] 176.2ms]
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",55,"ipmi"] 228.99ms]
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",55,"ipmi"] 194.16ms]
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",55,"ipmi"] 199.53ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MIB-Dell-10892' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'coolingDeviceTable']
coolingDeviceTable = No Such Object available on this agent at this OID
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MIB-Dell-10892' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'amperageProbeTableEntry']
amperageProbeTableEntry = No Such Object available on this agent at this OID
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MIB-Dell-10892' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'voltageProbeTable']
voltageProbeTable = No Such Object available on this agent at this OID
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MIB-Dell-10892' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'processorDeviceStatusTable']
processorDeviceStatusTable = No Such Object available on this agent at this OID
SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["processorDeviceStatusStatus"] 198.82ms]
SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [28524] 217.38ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MIB-Dell-10892' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'memoryDeviceTable']
memoryDeviceTable = No Such Object available on this agent at this OID
SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["memoryDeviceStatus"] 167.83ms]
SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [28525] 186.7ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MIB-Dell-10892' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'powerSupplyTable']
powerSupplyTable = No Such Object available on this agent at this OID
SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["powerSupplyStatus"] 178.67ms]
SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [28526] 191.9ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MIB-Dell-10892' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'intrusionTable']
intrusionTable = No Such Object available on this agent at this OID
SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["intrusionStatus"] 194.81ms]
SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [28527] 179.21ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'StorageManagement-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'controllerTable']
controllerTable = No Such Object available on this agent at this OID
SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["controllerState"] 178.23ms]
SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [28528] 185.61ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'StorageManagement-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'arrayDiskTable']
arrayDiskTable = No Such Object available on this agent at this OID
SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["arrayDiskState"] 205.76ms]
SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [28529] 168.55ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'StorageManagement-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'virtualDiskTable']
virtualDiskTable = No Such Object available on this agent at this OID
SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["virtualDiskState"] 179.24ms]
SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [28530] 207.65ms]
SQL[UPDATE `state_translations` set `state_index_id`=?,`state_descr`=?,`state_draw_graph`=?,`state_value`=?,`state_generic_value`=? WHERE `state_index_id`=? AND `state_value`=? [28530,"ready",1,1,0,28530,1] 200.57ms]
SQL[UPDATE `state_translations` set `state_index_id`=?,`state_descr`=?,`state_draw_graph`=?,`state_value`=?,`state_generic_value`=? WHERE `state_index_id`=? AND `state_value`=? [28530,"failed",1,2,2,28530,2] 233.83ms]
SQL[UPDATE `state_translations` set `state_index_id`=?,`state_descr`=?,`state_draw_graph`=?,`state_value`=?,`state_generic_value`=? WHERE `state_index_id`=? AND `state_value`=? [28530,"online",1,3,1,28530,3] 200.55ms]
SQL[UPDATE `state_translations` set `state_index_id`=?,`state_descr`=?,`state_draw_graph`=?,`state_value`=?,`state_generic_value`=? WHERE `state_index_id`=? AND `state_value`=? [28530,"offline",1,4,2,28530,4] 193.08ms]
SQL[insert into `state_translations` (`state_descr`, `state_draw_graph`, `state_generic_value`, `state_index_id`, `state_value`) values (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?) ["unknown",0,3,28530,0,"degraded",1,2,28530,6,"verifying",1,1,28530,7,"resynching",1,1,28530,15,"regenerating",1,1,28530,16,"failedRedundancy",1,2,28530,18,"rebuilding",1,1,28530,24,"formatting",1,1,28530,26,"reconstructing",1,1,28530,32,"initializing",1,1,28530,35,"backgroundInit",1,1,28530,36,"permanentlyDegraded",1,2,28530,52] 191.79ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'StorageManagement-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'batteryTable']
batteryTable = No Such Object available on this agent at this OID
SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["batteryState"] 227.48ms]
SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [28531] 197.88ms]
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MIB-Dell-10892' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'temperatureProbeTable']
temperatureProbeTable = No Such Object available on this agent at this OID
Airflow:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["airflow",55,"snmp"] 217.4ms]
Current:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["current",55,"snmp"] 221.68ms]
Charge:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["charge",55,"snmp"] 185.84ms]
Dbm:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["dbm",55,"snmp"] 196.72ms]
Fanspeed:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",55,"snmp"] 183.2ms]
Frequency:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["frequency",55,"snmp"] 190.53ms]
Humidity:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["humidity",55,"snmp"] 164.82ms]
Load:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["load",55,"snmp"] 210.87ms]
Power:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",55,"snmp"] 189.17ms]
Power_consumed:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_consumed",55,"snmp"] 199.94ms]
Power_factor:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_factor",55,"snmp"] 185.2ms]
Runtime:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["runtime",55,"snmp"] 217.06ms]
Signal:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["signal",55,"snmp"] 184.92ms]
State:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["state",55,"snmp"] 202.32ms]
Count:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["count",55,"snmp"] 172.14ms]
Temperature: SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.89.53.15.1.9.1']
41
Discover sensor: .1.3.6.1.4.1.89.53.15.1.9.1, 0, powerconnect, Internal Temperature, snmp, 1, 1, , 41, (limits: LL: 0, LW: , W: , H: 45)
SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","temperature",55,"powerconnect","0"] 182.2ms]
SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["temperature",55,"powerconnect","0"] 231.37ms]
.SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-Osqn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.5']
.*.4.1.674.10895.5000.2.6*.* No Such Object available on this agent at this OID
FTOS C-Series SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'F10-S-SERIES-CHASSIS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell:/opt/librenms/mibs/ftos' '-t' '3' 'udp:HOSTNAME:161' 'chStackUnitTemp']
MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/dell:/opt/librenms/mibs/ftos
Cannot find module (F10-S-SERIES-CHASSIS-MIB): At line 0 in (none)
chStackUnitTemp: Unknown Object Identifier (Sub-id not found: (top) -> chStackUnitTemp)
SNMP['/usr/bin/snmpbulkwalk' '-Cr30' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'F10-S-SERIES-CHASSIS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell:/opt/librenms/mibs/ftos' '-t' '3' 'udp:HOSTNAME:161' 'chStackUnitSysType']
MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/dell:/opt/librenms/mibs/ftos
Cannot find module (F10-S-SERIES-CHASSIS-MIB): At line 0 in (none)
chStackUnitSysType: Unknown Object Identifier (Sub-id not found: (top) -> chStackUnitSysType)
array (
'powerconnect' =>
array (
0 => 1,
),
)
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",55,"snmp"] 178.79ms]
0 -> powerconnect
0 -> powerconnect
Voltage:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",55,"snmp"] 174.6ms]
Snr:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["snr",55,"snmp"] 166.87ms]
Pressure:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["pressure",55,"snmp"] 176.79ms]
Cooling:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["cooling",55,"snmp"] 258.28ms]
Delay:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["delay",55,"snmp"] 176.96ms]
Quality_factor:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["quality_factor",55,"snmp"] 166.91ms]
Chromatic_dispersion:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["chromatic_dispersion",55,"snmp"] 169.76ms]
Ber:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["ber",55,"snmp"] 199.64ms]
Eer:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["eer",55,"snmp"] 175.99ms]
Waterflow:
SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["waterflow",55,"snmp"] 188.43ms]
>> Runtime for discovery module 'sensors': 19.6800 seconds with 140568 bytes
>> SNMP: [23/9.18s] MySQL: [45/8.77s] RRD: [0/0.00s]
#### Unload disco module sensors ####
Modules status: Global+
OS+
Device
#### Load disco module os ####
SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysDescr.0']
48G Ethernet Switch
SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovqn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-t' '3' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0']
.*.4.1.674.10895.3031
| 48G Ethernet Switch | .1.3.6.1.4.1.674.10895.3031 |
OS: Dell PowerConnect (powerconnect)
>> Runtime for discovery module 'os': 0.2250 seconds with 50496 bytes
>> SNMP: [2/0.22s] MySQL: [0/0.00s] RRD: [0/0.00s]
#### Unload disco module os ####
SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [55,"poll_mib"] 165.13ms]
SQL[UPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [21.823,55] 169.32ms]
Discovered in 21.823 seconds
SQL[INSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) {"type":"discover","doing":"55","start":1559648050.183159,"duration":"23.23","devices":1,"poller":"poller-mon-1-2"} 175ms]
./discovery.php 55 2019-06-04 11:34:33 - 1 devices discovered in 23.23 secs
SNMP [27/9.69s]: Get[5/0.61s] Getnext[0/0.00s] Walk[22/9.07s]
MySQL [52/10.00s]: Cell[10/1.91s] Row[-6/-1.11s] Rows[40/7.66s] Column[0/0.00s] Update[5/1.00s] Insert[3/0.54s] Delete[0/0.00s]
RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment