15:38:19.389684 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:38:19.491478 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:38:20.396112 T00120000 Read-Data CH water pressure: 0.00 | |
15:38:20.403928 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:38:20.456327 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:38:20.504185 AF0120000 Unk-DataId CH water pressure: 0.00 | |
15:38:21.493849 T80000200 Read-Data Status: 00000010 00000000 | |
15:38:21.513543 B40000200 Read-Ack Status: 00000010 00000000 | |
15:38:22.512055 T10010600 Write-Data Control setpoint: 6.00 | |
15:38:22.555639 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:38:23.746957 T00110000 Read-Data Relative modulation level: 0.00 | |
15:38:23.754779 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:38:24.562848 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:38:24.573574 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:38:25.789496 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:38:25.799571 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:38:26.610194 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:38:26.714301 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:38:27.446287 T10010600 Write-Data Control setpoint: 6.00 | |
15:38:27.570382 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:38:28.657837 T00110000 Read-Data Relative modulation level: 0.00 | |
15:38:28.667439 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:38:29.480844 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:38:29.569415 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:38:30.706247 T001B0000 Read-Data Outside temperature: 0.00 | |
15:38:30.713645 R00770000 Read-Data DHW burner starts: 0 | |
15:38:30.726960 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:38:30.740487 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:38:31.477937 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:38:31.574433 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:38:32.775227 T10010600 Write-Data Control setpoint: 6.00 | |
15:38:32.782679 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:38:33.489019 T00110000 Read-Data Relative modulation level: 0.00 | |
15:38:33.554252 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:38:34.799233 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:38:34.806482 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:38:35.608883 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:38:35.660340 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:38:36.847825 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:38:36.943293 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:38:37.520050 T10010600 Write-Data Control setpoint: 6.00 | |
15:38:37.669792 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:38:38.919210 T00110000 Read-Data Relative modulation level: 0.00 | |
15:38:38.933137 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:38:39.727056 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:38:39.735934 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:38:40.545267 T10100A00 Write-Data Room setpoint: 10.00 | |
15:38:40.676644 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:38:41.548725 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:38:41.669234 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:38:42.584310 T10010600 Write-Data Control setpoint: 6.00 | |
15:38:42.670673 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:38:43.578608 T00110000 Read-Data Relative modulation level: 0.00 | |
15:38:43.667128 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:38:44.596308 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:38:44.688281 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:38:45.589500 T901812E8 Write-Data Room temperature: 18.91 | |
15:38:45.680231 B501812E8 Write-Ack Room temperature: 18.91 | |
15:38:46.496598 Command: PR=W | |
15:38:46.583103 PR: W=A | |
15:38:46.590426 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:38:46.701512 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:38:47.194901 Command: PR=L | |
15:38:47.200840 Command: PR=G | |
15:38:47.303781 PR: L=FXOMPC | |
15:38:47.595836 T10010600 Write-Data Control setpoint: 6.00 | |
15:38:47.692610 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:38:49.301408 T00110000 Read-Data Relative modulation level: 0.00 | |
15:38:49.317598 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:38:49.614734 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:38:49.772550 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:38:50.674007 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:38:50.689727 R00780000 Read-Data Burner operation hours: 0 | |
15:38:50.767785 B4078153C Read-Ack Burner operation hours: 5436 | |
15:38:50.779905 AC0091700 Read-Ack Remote override room setpoint: 23.00 | |
15:38:51.631621 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:38:51.641051 R80790000 Read-Data CH pump operation hours: 0 | |
15:38:51.766154 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:38:51.772446 AC0091700 Read-Ack Remote override room setpoint: 23.00 | |
15:38:52.654929 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:38:52.663295 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:38:52.765664 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:38:52.772994 AC0091700 Read-Ack Remote override room setpoint: 23.00 | |
15:38:53.644113 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:38:53.767517 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:38:54.871487 T10013A00 Write-Data Control setpoint: 58.00 | |
15:38:54.879387 BD0013A00 Write-Ack Control setpoint: 58.00 | |
15:38:55.659637 T00110000 Read-Data Relative modulation level: 0.00 | |
15:38:55.768751 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:38:56.919418 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:38:56.927985 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:38:57.741644 T00630000 Read-Data Message ID 99: 0 | |
15:38:57.748262 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:38:57.760640 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:38:57.789621 AF0630000 Unk-DataId Message ID 99: 0 | |
15:38:58.991679 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:38:59.145007 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:38:59.790679 T10013A00 Write-Data Control setpoint: 58.00 | |
15:38:59.807863 BD0013A00 Write-Ack Control setpoint: 58.00 | |
15:39:00.000475 Command: SC=15:39/6 | |
15:39:00.183987 SC: 15:39/6 | |
15:39:00.697131 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:00.787867 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:01.834323 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:01.842984 B4019280A Read-Ack Boiler water temperature: 40.04 | |
15:39:03.073411 T801A0000 Read-Data DHW temperature: 0.00 | |
15:39:03.080927 R00740000 Read-Data Burner starts: 0 | |
15:39:03.095373 BC074FFFF Read-Ack Burner starts: 65535 | |
15:39:03.106042 A701A0000 Unk-DataId DHW temperature: 0.00 | |
15:39:03.737932 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:03.868673 BC0000300 Read-Ack Status: 00000011 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:05.521558 T10013A00 Write-Data Control setpoint: 58.00 | |
15:39:05.528398 BD0013A00 Write-Ack Control setpoint: 58.00 | |
15:39:05.738718 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:05.864635 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:06.932794 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:06.960614 BC0192978 Read-Ack Boiler water temperature: 41.47 | |
15:39:07.981608 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:39:08.057449 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:39:08.820956 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:09.034262 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:09.763886 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:10.140365 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:10.865324 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:10.969042 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:11.937806 T90013A19 Write-Data Control setpoint: 58.10 | |
15:39:11.947958 B50013A19 Write-Ack Control setpoint: 58.10 | |
15:39:12.917068 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:12.929355 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:13.799865 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:13.953703 BC0192E9E Read-Ack Boiler water temperature: 46.62 | |
15:39:14.940980 T001B0000 Read-Data Outside temperature: 0.00 | |
15:39:14.955657 R80750000 Read-Data CH pump starts: 0 | |
15:39:14.978817 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:39:15.003896 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:39:16.182963 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:16.397154 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:16.946487 T90013A19 Write-Data Control setpoint: 58.10 | |
15:39:16.965615 B50013A19 Write-Ack Control setpoint: 58.10 | |
15:39:18.224544 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:18.244080 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:19.037047 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:19.055822 BC0192D26 Read-Ack Boiler water temperature: 45.15 | |
15:39:20.267761 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:39:20.285221 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:39:21.088797 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:39:21.105684 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:39:21.908445 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:22.067486 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:23.133642 T10015A00 Write-Data Control setpoint: 90.00 | |
15:39:23.149299 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:39:23.953642 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:23.971917 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:24.870232 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:24.964440 B40192657 Read-Ack Boiler water temperature: 38.34 | |
15:39:26.025144 T10101700 Write-Data Room setpoint: 23.00 | |
15:39:26.042212 BD0101700 Write-Ack Room setpoint: 23.00 | |
15:39:26.885137 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:27.082065 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:28.049150 T10015A00 Write-Data Control setpoint: 90.00 | |
15:39:28.065803 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:39:29.284035 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:29.302119 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:30.505896 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:30.522118 B401923BA Read-Ack Boiler water temperature: 35.73 | |
15:39:31.325867 T901812E8 Write-Data Room temperature: 18.91 | |
15:39:31.344008 B501812E8 Write-Ack Room temperature: 18.91 | |
15:39:31.964521 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:32.126394 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:32.963658 T10015A00 Write-Data Control setpoint: 90.00 | |
15:39:33.054601 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:39:33.942733 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:34.051351 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:35.015328 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:35.075751 B40192370 Read-Ack Boiler water temperature: 35.44 | |
15:39:36.249100 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:39:36.267445 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:39:36.302307 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:39:36.336037 AC0091700 Read-Ack Remote override room setpoint: 23.00 | |
15:39:36.971932 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:37.212011 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:37.972325 T10015A00 Write-Data Control setpoint: 90.00 | |
15:39:38.067418 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:39:39.011665 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:39.141709 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:40.086626 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:40.148574 B40192351 Read-Ack Boiler water temperature: 35.32 | |
15:39:41.158592 T00630000 Read-Data Message ID 99: 0 | |
15:39:41.178751 R00770000 Read-Data DHW burner starts: 0 | |
15:39:41.212241 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:39:41.247092 AF0630000 Unk-DataId Message ID 99: 0 | |
15:39:42.025625 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:42.265525 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:43.012172 T10015A00 Write-Data Control setpoint: 90.00 | |
15:39:43.138933 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:39:44.024032 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:44.131670 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:45.026033 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:45.132810 BC0192399 Read-Ack Boiler water temperature: 35.60 | |
15:39:46.039182 T001D0000 Read-Data Solar storage temperature: 0.00 | |
15:39:46.057927 R00780000 Read-Data Burner operation hours: 0 | |
15:39:46.139155 B4078153C Read-Ack Burner operation hours: 5436 | |
15:39:46.158911 AF01D0000 Unk-DataId Solar storage temperature: 0.00 | |
15:39:47.043049 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:47.222503 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:48.119671 T10015A00 Write-Data Control setpoint: 90.00 | |
15:39:48.138679 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:39:49.349060 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:49.368701 Medium power | |
15:39:50.169555 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:50.215554 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:51.080397 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:51.232747 BC01923F5 Read-Ack Boiler water temperature: 35.96 | |
15:39:52.091945 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:39:52.238989 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:39:53.444885 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:53.603047 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:54.247271 T10015A00 Write-Data Control setpoint: 90.00 | |
15:39:54.265587 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:39:55.329100 T00110000 Read-Data Relative modulation level: 0.00 | |
15:39:55.347442 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:39:56.312101 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:39:56.328913 B40192400 Read-Ack Boiler water temperature: 36.00 | |
15:39:57.129446 T001B0000 Read-Data Outside temperature: 0.00 | |
15:39:57.146264 R80790000 Read-Data CH pump operation hours: 0 | |
15:39:57.229655 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:39:57.241225 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:39:58.366266 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:39:58.540733 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:39:59.177741 T10015A00 Write-Data Control setpoint: 90.00 | |
15:39:59.223046 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:00.001274 Command: SC=15:40/6 | |
15:40:00.142654 SC: 15:40/6 | |
15:40:00.161386 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:00.244178 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:01.227119 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:01.245605 B40192400 Read-Ack Boiler water temperature: 36.00 | |
15:40:02.172104 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:40:02.329315 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:40:03.276693 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:03.440123 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:04.187213 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:04.330981 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:04.643984 Low power | |
15:40:05.326635 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:05.343933 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:06.550705 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:06.573658 BC01923CC Read-Ack Boiler water temperature: 35.80 | |
15:40:07.206113 T10101700 Write-Data Room setpoint: 23.00 | |
15:40:07.334728 BD0101700 Write-Ack Room setpoint: 23.00 | |
15:40:08.329720 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:08.436154 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:09.386627 Command: TC=21.00 | |
15:40:09.393620 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:09.405054 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:10.236570 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:10.328484 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:11.475439 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:11.493068 B401923B3 Read-Ack Boiler water temperature: 35.70 | |
15:40:12.244503 T101812F8 Write-Data Room temperature: 18.97 | |
15:40:12.336888 BD01812F8 Write-Ack Room temperature: 18.97 | |
15:40:13.925072 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:14.144773 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:14.237924 Command: TC=21.00 | |
15:40:14.283368 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:14.328188 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:15.565804 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:15.583749 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:16.384003 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:16.443058 B401923B3 Read-Ack Boiler water temperature: 35.70 | |
15:40:17.635093 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:40:17.654054 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:40:17.688329 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:40:17.722517 AC0091700 Read-Ack Remote override room setpoint: 23.00 | |
15:40:18.444463 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:18.679466 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:19.659552 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:19.678774 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:20.478708 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:20.498034 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:21.709058 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:21.727361 B401923B3 Read-Ack Boiler water temperature: 35.70 | |
15:40:22.315415 T00630000 Read-Data Message ID 99: 0 | |
15:40:22.333763 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:40:22.427160 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:40:22.447259 AF0630000 Unk-DataId Message ID 99: 0 | |
15:40:23.345526 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:23.497629 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:23.616135 Medium power | |
15:40:24.371109 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:24.417459 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:25.338521 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:25.433408 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:26.621276 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:26.639582 BC01923E1 Read-Ack Boiler water temperature: 35.88 | |
15:40:27.441569 T00300000 Read-Data DHW setpoint boundaries: 0 0 | |
15:40:27.497219 BC0303C28 Read-Ack DHW setpoint boundaries: 60 40 | |
15:40:28.669702 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:28.817299 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:29.494476 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:29.511168 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:31.149201 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:31.168805 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:31.387814 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:31.508452 BC0192423 Read-Ack Boiler water temperature: 36.14 | |
15:40:32.787694 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:40:32.805892 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:40:33.404731 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:33.552440 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:33.658986 Command: TC=21.00 | |
15:40:33.786648 TC: 21.00 | |
15:40:34.411470 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:34.508969 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:35.419564 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:35.515642 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:36.428761 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:36.520551 BC0192480 Read-Ack Boiler water temperature: 36.50 | |
15:40:37.434565 T001B0000 Read-Data Outside temperature: 0.00 | |
15:40:37.452339 R00740000 Read-Data Burner starts: 0 | |
15:40:37.527358 BC074FFFF Read-Ack Burner starts: 65535 | |
15:40:37.544863 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:40:38.444018 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:38.575804 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:38.976670 Low power | |
15:40:39.456554 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:39.610997 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:40.551263 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:40.609866 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:41.464950 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:41.609948 BC01924B3 Read-Ack Boiler water temperature: 36.70 | |
15:40:42.602310 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:40:42.621031 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:40:43.480682 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:43.621008 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:44.486503 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:44.611833 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:45.532425 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:45.589556 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:46.696444 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:46.714381 B401924EB Read-Ack Boiler water temperature: 36.92 | |
15:40:47.675012 T10101700 Write-Data Room setpoint: 23.00 | |
15:40:47.693784 BD0101700 Write-Ack Room setpoint: 23.00 | |
15:40:48.516129 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:48.729326 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:49.559711 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:49.614664 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:50.752471 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:50.769908 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:51.542811 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:51.635486 B40192519 Read-Ack Boiler water temperature: 37.10 | |
15:40:52.544879 T10181300 Write-Data Room temperature: 19.00 | |
15:40:52.638025 BD0181300 Write-Ack Room temperature: 19.00 | |
15:40:53.591328 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:40:53.729846 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:40:54.615119 T10015A00 Write-Data Control setpoint: 90.00 | |
15:40:54.704411 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:40:55.663480 T00110000 Read-Data Relative modulation level: 0.00 | |
15:40:55.688264 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:40:56.560380 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:40:56.692887 B4019254C Read-Ack Boiler water temperature: 37.30 | |
15:40:57.755326 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:40:57.777695 R80750000 Read-Data CH pump starts: 0 | |
15:40:57.811197 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:40:57.837675 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:40:58.570711 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:40:58.592465 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:40:58.697151 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:40:58.716332 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:40:59.556576 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:40:59.576844 R00770000 Read-Data DHW burner starts: 0 | |
15:40:59.693324 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:40:59.712148 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:41:00.000541 Command: SC=15:41/6 | |
15:41:00.108633 SC: 15:41/6 | |
15:41:00.618887 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:00.762131 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:01.848110 T10015A00 Write-Data Control setpoint: 90.00 | |
15:41:01.866195 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:41:02.669052 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:02.687363 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:03.900042 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:03.919653 BC0192599 Read-Ack Boiler water temperature: 37.60 | |
15:41:04.722198 T00630000 Read-Data Message ID 99: 0 | |
15:41:04.740377 R00780000 Read-Data Burner operation hours: 0 | |
15:41:04.772846 B4078153C Read-Ack Burner operation hours: 5436 | |
15:41:04.795723 AF0630000 Unk-DataId Message ID 99: 0 | |
15:41:05.945062 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:06.085055 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:06.765815 T10015A00 Write-Data Control setpoint: 90.00 | |
15:41:06.783403 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:41:08.008531 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:08.028668 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:08.688029 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:08.707874 BC01925CC Read-Ack Boiler water temperature: 37.80 | |
15:41:09.658968 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:09.801006 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:10.860043 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:41:10.872138 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:41:11.678873 T80310000 Read-Data Max CH setpoint boundaries: 0 0 | |
15:41:11.791554 B40314B14 Read-Ack Max CH setpoint boundaries: 75 20 | |
15:41:12.907194 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:13.033767 BC0000202 Read-Ack Status: 00000010 00000010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:13.726215 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:13.888125 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:14.956853 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:15.089121 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:15.787953 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:15.913383 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:16.393298 Command: TC=21.00 | |
15:41:16.549201 TC: 21.00 | |
15:41:16.687506 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:16.794367 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:17.823389 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:17.840475 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:19.051709 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:19.069051 BC0192300 Read-Ack Boiler water temperature: 35.00 | |
15:41:19.875828 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:41:19.891646 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:41:21.102193 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:21.241909 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:21.943985 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:21.961062 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:23.173710 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:23.192232 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:23.756399 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:23.898882 BC0192078 Read-Ack Boiler water temperature: 32.47 | |
15:41:24.785550 T001B0000 Read-Data Outside temperature: 0.00 | |
15:41:24.802925 R80790000 Read-Data CH pump operation hours: 0 | |
15:41:24.891082 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:41:24.908757 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:41:26.013907 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:26.149455 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:26.834827 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:26.891993 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:28.063964 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:28.083470 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:28.882158 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:28.893386 BC0191F11 Read-Ack Boiler water temperature: 31.07 | |
15:41:30.111504 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:41:30.130540 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:41:30.932015 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:31.112275 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:32.137847 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:32.155013 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:32.978449 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:32.995959 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:33.823872 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:33.923858 B40191E99 Read-Ack Boiler water temperature: 30.60 | |
15:41:35.050095 T10100A00 Write-Data Room setpoint: 10.00 | |
15:41:35.071637 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:41:35.839783 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:36.000140 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:36.857487 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:36.970157 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:37.852777 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:37.975057 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:39.123553 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:39.141997 BC0191E80 Read-Ack Boiler water temperature: 30.50 | |
15:41:39.942393 T10181300 Write-Data Room temperature: 19.00 | |
15:41:39.962391 BD0181300 Write-Ack Room temperature: 19.00 | |
15:41:40.872597 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:41.128920 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:41.989844 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:42.009620 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:43.219462 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:43.238608 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:43.897042 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:43.988478 BC0191E80 Read-Ack Boiler water temperature: 30.50 | |
15:41:44.901646 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:41:44.923610 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:41:45.002127 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:41:45.016037 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:41:45.919940 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:46.178027 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:46.917696 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:47.074282 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:47.930830 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:48.125136 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:48.981046 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:49.079023 BC0191E80 Read-Ack Boiler water temperature: 30.50 | |
15:41:49.941552 T00630000 Read-Data Message ID 99: 0 | |
15:41:49.947369 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:41:50.076893 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:41:50.082886 AF0630000 Unk-DataId Message ID 99: 0 | |
15:41:51.001555 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:51.117389 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:52.165507 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:52.172212 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:52.967736 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:53.075709 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:53.970489 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:54.077826 B40191E99 Read-Ack Boiler water temperature: 30.60 | |
15:41:55.107227 T10382800 Write-Data DHW setpoint: 40.00 | |
15:41:55.116314 BD0382800 Write-Ack DHW setpoint: 40.00 | |
15:41:56.276255 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:41:56.407434 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:41:56.993686 T10010600 Write-Data Control setpoint: 6.00 | |
15:41:57.086003 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:41:58.380252 T00110000 Read-Data Relative modulation level: 0.00 | |
15:41:58.386113 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:41:59.012325 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:41:59.180504 B40191E99 Read-Ack Boiler water temperature: 30.60 | |
15:42:00.007715 Command: SC=15:42/6 | |
15:42:00.065256 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:42:00.179037 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:42:01.027384 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:01.183126 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:02.095305 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:02.185099 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:03.135796 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:03.183242 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:04.112185 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:04.158777 B40191E99 Read-Ack Boiler water temperature: 30.60 | |
15:42:05.341925 T001B0000 Read-Data Outside temperature: 0.00 | |
15:42:05.348379 R00740000 Read-Data Burner starts: 0 | |
15:42:05.396860 BC074FFFF Read-Ack Burner starts: 65535 | |
15:42:05.420928 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:42:06.158081 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:06.240365 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:07.181458 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:07.187988 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:08.207007 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:08.214256 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:09.433300 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:09.453557 BC0191EB3 Read-Ack Boiler water temperature: 30.70 | |
15:42:10.252407 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:42:10.258523 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:42:11.481495 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:11.625463 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:12.185839 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:12.234389 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:13.532254 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:13.538227 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:14.125759 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:14.257811 B40191ECC Read-Ack Boiler water temperature: 30.80 | |
15:42:15.193116 T10100A00 Write-Data Room setpoint: 10.00 | |
15:42:15.235150 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:42:16.141949 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:16.257243 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:17.153452 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:17.257604 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:18.443949 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:18.449662 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:19.263724 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:19.269601 B40191EF3 Read-Ack Boiler water temperature: 30.95 | |
15:42:20.172791 T1018130C Write-Data Room temperature: 19.05 | |
15:42:20.265610 BD018130C Write-Ack Room temperature: 19.05 | |
15:42:20.705726 Command: TC=21.00 | |
15:42:20.776610 TC: 21.00 | |
15:42:21.312753 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:21.453019 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:22.207616 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:22.256050 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:23.360031 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:23.365952 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:24.202381 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:24.359782 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:42:25.408084 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:42:25.414820 R80750000 Read-Data CH pump starts: 0 | |
15:42:25.437166 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:42:25.456855 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:42:26.226523 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:26.369630 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:27.238940 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:27.362301 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:28.322487 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:28.382618 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:29.503904 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:29.510207 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:42:30.324900 T00630000 Read-Data Message ID 99: 0 | |
15:42:30.331128 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:42:30.383772 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:42:30.390397 AF0630000 Unk-DataId Message ID 99: 0 | |
15:42:31.553810 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:31.659680 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:32.256235 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:32.349785 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:33.605740 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:33.613093 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:34.419121 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:34.422935 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:42:35.426161 T90395A00 Write-Data Max CH water setpoint: 90.00 | |
15:42:35.433606 B60394B00 Data-Inv Max CH water setpoint: 75.00 | |
15:42:36.285624 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:36.451040 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:37.310552 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:37.450548 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:38.298592 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:38.452972 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:39.335762 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:39.459718 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:42:40.313644 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:42:40.448783 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:42:41.319376 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:41.459736 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:42.326856 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:42.456041 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:43.336796 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:43.453968 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:44.339703 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:44.476819 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:42:45.383607 T001B0000 Read-Data Outside temperature: 0.00 | |
15:42:45.390564 R00770000 Read-Data DHW burner starts: 0 | |
15:42:45.451770 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:42:45.502604 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:42:46.354048 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:46.450213 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:47.362745 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:47.469229 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:48.377003 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:48.458833 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:49.375055 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:49.467899 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:42:50.386634 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:42:50.475363 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:42:51.393851 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:51.580586 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:52.398424 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:52.535095 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:53.697830 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:53.704158 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:54.493384 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:54.538486 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:42:55.418209 T10100A00 Write-Data Room setpoint: 10.00 | |
15:42:55.537267 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:42:56.429864 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:42:56.576715 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:42:57.434719 T10010600 Write-Data Control setpoint: 6.00 | |
15:42:57.537125 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:42:58.586382 T00110000 Read-Data Relative modulation level: 0.00 | |
15:42:58.593091 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:42:59.815995 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:42:59.822368 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:43:00.001171 Command: SC=15:43/6 | |
15:43:00.088115 SC: 15:43/6 | |
15:43:00.638693 T10181317 Write-Data Room temperature: 19.09 | |
15:43:00.644979 BD0181317 Write-Ack Room temperature: 19.09 | |
15:43:01.461580 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:01.571678 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:02.469758 T10010600 Write-Data Control setpoint: 6.00 | |
15:43:02.562106 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:43:03.535777 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:03.650162 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:04.628194 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:04.634371 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:43:05.555837 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:43:05.562771 R00780000 Read-Data Burner operation hours: 0 | |
15:43:05.646444 B4078153C Read-Ack Burner operation hours: 5436 | |
15:43:05.653705 A40091500 Read-Ack Remote override room setpoint: 21.00 | |
15:43:06.498092 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:43:06.510760 R80790000 Read-Data CH pump operation hours: 0 | |
15:43:06.641980 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:43:06.645114 A40091500 Read-Ack Remote override room setpoint: 21.00 | |
15:43:07.505266 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:43:07.514718 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:43:07.642104 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:43:07.644807 A40091500 Read-Ack Remote override room setpoint: 21.00 | |
15:43:08.826838 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:09.004800 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:10.059125 T10010600 Write-Data Control setpoint: 6.00 | |
15:43:10.069663 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:43:10.888085 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:10.894102 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:11.692945 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:11.700133 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:43:12.925203 T00630000 Read-Data Message ID 99: 0 | |
15:43:12.931201 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:43:12.950802 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:43:12.973340 AF0630000 Unk-DataId Message ID 99: 0 | |
15:43:13.753502 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:13.841600 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:14.979197 T90013800 Write-Data Control setpoint: 56.00 | |
15:43:14.985446 B50013800 Write-Ack Control setpoint: 56.00 | |
15:43:15.798081 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:15.805056 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:16.606070 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:17.243722 BC0191F00 Read-Ack Boiler water temperature: 31.00 | |
15:43:17.837562 T80640000 Read-Data Remote override function: 00000000 | |
15:43:17.844138 R00740000 Read-Data Burner starts: 0 | |
15:43:17.865054 BC074FFFF Read-Ack Burner starts: 65535 | |
15:43:17.889841 A40640101 Read-Ack Remote override function: 00000001 | |
- Manual change priority: enable overrule (1) | |
- Program change priority: disable overrule (0) | |
15:43:18.592570 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:18.757474 BC0000300 Read-Ack Status: 00000011 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:19.592255 T90013800 Write-Data Control setpoint: 56.00 | |
15:43:19.730058 B50013800 Write-Ack Control setpoint: 56.00 | |
15:43:20.710026 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:20.717623 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:21.934216 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:21.941099 B40191F94 Read-Ack Boiler water temperature: 31.58 | |
15:43:22.751527 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:43:22.754317 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:43:23.855579 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:24.017573 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:24.801226 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:24.945063 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:26.029177 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:26.190092 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:26.849304 T10013819 Write-Data Control setpoint: 56.10 | |
15:43:26.855621 BD0013819 Write-Ack Control setpoint: 56.10 | |
15:43:27.668668 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:27.757378 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:28.897322 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:28.912598 B40192573 Read-Ack Boiler water temperature: 37.45 | |
15:43:29.715356 T001B0000 Read-Data Outside temperature: 0.00 | |
15:43:29.718246 R80750000 Read-Data CH pump starts: 0 | |
15:43:29.816097 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:43:29.822984 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:43:30.945404 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:31.109735 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:31.742675 T10013819 Write-Data Control setpoint: 56.10 | |
15:43:31.789278 BD0013819 Write-Ack Control setpoint: 56.10 | |
15:43:32.691412 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:32.826534 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:33.812925 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:33.819193 BC01927C7 Read-Ack Boiler water temperature: 39.78 | |
15:43:34.708556 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:43:34.823122 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:43:35.882932 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:43:35.889910 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:43:37.102379 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:37.240018 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:37.913815 T10015A00 Write-Data Control setpoint: 90.00 | |
15:43:37.920218 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:43:39.149421 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:39.155718 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:39.967425 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:39.974128 B4019271E Read-Ack Boiler water temperature: 39.12 | |
15:43:40.763679 T90101500 Write-Data Room setpoint: 21.00 | |
15:43:40.922888 B50101500 Write-Ack Room setpoint: 21.00 | |
15:43:41.764276 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:41.926059 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:42.823514 T10015A00 Write-Data Control setpoint: 90.00 | |
15:43:42.924036 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:43:43.784615 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:43.926219 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:44.857582 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:44.925842 B40192680 Read-Ack Boiler water temperature: 38.50 | |
15:43:45.801245 T10181321 Write-Data Room temperature: 19.13 | |
15:43:45.932493 BD0181321 Write-Ack Room temperature: 19.13 | |
15:43:46.810749 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:46.925972 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:48.155381 T10015A00 Write-Data Control setpoint: 90.00 | |
15:43:48.162567 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:43:48.829134 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:48.931991 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:49.837315 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:49.929689 BC0192666 Read-Ack Boiler water temperature: 38.40 | |
15:43:50.847002 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:43:50.853347 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:43:51.010850 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:43:51.017173 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:43:51.858076 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:43:51.864212 R00770000 Read-Data DHW burner starts: 0 | |
15:43:52.013438 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:43:52.015967 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:43:53.062755 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:43:53.066490 R00780000 Read-Data Burner operation hours: 0 | |
15:43:53.075301 B4078153C Read-Ack Burner operation hours: 5436 | |
15:43:53.083953 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:43:53.883645 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:54.025459 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:43:55.147825 T10015A00 Write-Data Control setpoint: 90.00 | |
15:43:55.154839 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:43:55.893884 T00110000 Read-Data Relative modulation level: 0.00 | |
15:43:56.010929 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:43:56.942137 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:43:56.990559 B4019264C Read-Ack Boiler water temperature: 38.30 | |
15:43:57.909959 T00630000 Read-Data Message ID 99: 0 | |
15:43:57.916186 R80790000 Read-Data CH pump operation hours: 0 | |
15:43:58.015040 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:43:58.021427 AF0630000 Unk-DataId Message ID 99: 0 | |
15:43:59.230669 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:43:59.370571 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:00.001512 Command: SC=15:44/6 | |
15:44:00.011215 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:00.034664 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:01.280010 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:44:01.286527 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:44:02.078571 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:02.084889 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:03.304669 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:03.310920 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:04.122929 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:04.129476 B40192680 Read-Ack Boiler water temperature: 38.50 | |
15:44:05.352788 T00740000 Read-Data Burner starts: 0 | |
15:44:05.357694 BC074FFFF Read-Ack Burner starts: 65535 | |
15:44:06.171857 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:06.287749 B4000020A Read-Ack Status: 00000010 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:06.991296 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:07.097482 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:08.218749 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:08.225430 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:09.044552 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:09.091028 BC0192699 Read-Ack Boiler water temperature: 38.60 | |
15:44:10.006565 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:44:10.098630 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:44:11.109913 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:11.247390 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:12.021712 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:12.116051 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:13.139839 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:13.144798 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:14.362965 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:14.366718 BC01923E8 Read-Ack Boiler water temperature: 35.91 | |
15:44:15.182692 T001B0000 Read-Data Outside temperature: 0.00 | |
15:44:15.189652 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:44:15.210365 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:44:15.230588 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:44:16.424688 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:16.538549 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:17.231768 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:17.238493 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:18.460311 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:18.463014 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:19.126645 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:19.172893 B40192105 Read-Ack Boiler water temperature: 33.02 | |
15:44:20.098376 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:44:20.186091 Command: TC=20.00 | |
15:44:20.203906 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:44:21.328879 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:21.422516 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:22.151758 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:22.195566 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:23.375103 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:23.381443 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:24.238699 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:24.245311 B40191F38 Read-Ack Boiler water temperature: 31.22 | |
15:44:25.429586 T10100A00 Write-Data Room setpoint: 10.00 | |
15:44:25.436769 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:44:26.140740 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:26.288790 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:27.370645 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:27.384845 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:28.291612 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:28.313198 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:29.519587 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:29.539081 BC0191E80 Read-Ack Boiler water temperature: 30.50 | |
15:44:30.339422 T10181321 Write-Data Room temperature: 19.13 | |
15:44:30.359723 BD0181321 Write-Ack Room temperature: 19.13 | |
15:44:31.567493 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:31.716075 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:32.311781 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:32.331586 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:33.206855 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:33.270253 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:34.195905 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:34.299885 BC0191E4C Read-Ack Boiler water temperature: 30.30 | |
15:44:35.340026 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:44:35.362568 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:44:35.388305 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:44:35.414593 A40091500 Read-Ack Remote override room setpoint: 21.00 | |
15:44:36.482673 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:44:36.508173 R00740000 Read-Data Burner starts: 0 | |
15:44:36.544378 BC074FFFF Read-Ack Burner starts: 65535 | |
15:44:36.577970 A40091500 Read-Ack Remote override room setpoint: 21.00 | |
15:44:37.325429 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:44:37.347102 R80750000 Read-Data CH pump starts: 0 | |
15:44:37.383921 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:44:37.420303 A40091500 Read-Ack Remote override room setpoint: 21.00 | |
15:44:38.225001 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:38.505960 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:39.351298 T10010600 Write-Data Control setpoint: 6.00 | |
15:44:39.410574 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:44:40.580931 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:40.604337 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:41.399397 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:41.425284 BC0191E4C Read-Ack Boiler water temperature: 30.30 | |
15:44:42.381273 T00630000 Read-Data Message ID 99: 0 | |
15:44:42.403889 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:44:42.445054 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:44:42.478545 AF0630000 Unk-DataId Message ID 99: 0 | |
15:44:43.445419 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:43.670729 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:44.675538 T90013800 Write-Data Control setpoint: 56.00 | |
15:44:44.696136 B50013800 Write-Ack Control setpoint: 56.00 | |
15:44:45.496727 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:45.517307 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:46.321644 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:46.383222 BC0191E80 Read-Ack Boiler water temperature: 30.50 | |
15:44:47.400164 T00770000 Read-Data DHW burner starts: 0 | |
15:44:47.436009 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:44:48.384324 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:48.667425 BC0000300 Read-Ack Status: 00000011 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:49.589512 T90013800 Write-Data Control setpoint: 56.00 | |
15:44:49.609430 B50013800 Write-Ack Control setpoint: 56.00 | |
15:44:50.315990 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:50.431256 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:51.578418 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:51.600962 BC0191E80 Read-Ack Boiler water temperature: 30.50 | |
15:44:52.330332 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:44:52.494021 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:44:53.339668 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:53.494182 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:54.505282 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:54.658516 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:55.358094 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:44:55.516160 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:44:56.361459 T10013819 Write-Data Control setpoint: 56.10 | |
15:44:56.476203 BD0013819 Write-Ack Control setpoint: 56.10 | |
15:44:57.368671 T00110000 Read-Data Relative modulation level: 0.00 | |
15:44:57.474343 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:44:58.602012 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:44:58.622622 B4019241E Read-Ack Boiler water temperature: 36.12 | |
15:44:59.384879 T001B0000 Read-Data Outside temperature: 0.00 | |
15:44:59.395309 R00770000 Read-Data DHW burner starts: 0 | |
15:44:59.478232 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:44:59.496794 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:45:00.001395 Command: SC=15:45/6 | |
15:45:00.091312 SC: 15:45/6 | |
15:45:00.393473 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:00.578321 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:01.401838 T10013819 Write-Data Control setpoint: 56.10 | |
15:45:01.500186 BD0013819 Write-Ack Control setpoint: 56.10 | |
15:45:02.412152 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:02.577023 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:03.538524 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:03.598669 BC019263A Read-Ack Boiler water temperature: 38.23 | |
15:45:04.425235 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:45:04.574940 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:45:05.565412 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:45:05.585314 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:45:06.587234 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:06.748675 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:07.449647 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:07.581541 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:08.851567 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:08.869825 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:09.660839 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:09.682417 B401926B3 Read-Ack Boiler water temperature: 38.70 | |
15:45:10.684712 T90101500 Write-Data Room setpoint: 21.00 | |
15:45:10.705263 B50101500 Write-Ack Room setpoint: 21.00 | |
15:45:11.481170 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:11.643799 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:12.498784 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:12.557070 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:13.756180 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:13.775155 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:14.579715 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:14.589383 B4019270F Read-Ack Boiler water temperature: 39.06 | |
15:45:15.837029 T1018132B Write-Data Room temperature: 19.17 | |
15:45:15.855930 BD018132B Write-Ack Room temperature: 19.17 | |
15:45:16.654760 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:16.750677 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:17.534201 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:17.682943 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:18.673223 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:18.691768 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:19.900239 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:19.911920 BC019274C Read-Ack Boiler water temperature: 39.30 | |
15:45:20.719578 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:45:20.726227 R00780000 Read-Data Burner operation hours: 0 | |
15:45:20.739099 B4078153C Read-Ack Burner operation hours: 5436 | |
15:45:20.750425 A40091500 Read-Ack Remote override room setpoint: 21.00 | |
15:45:21.948731 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:22.066318 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:22.572788 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:22.664665 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:24.004039 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:24.031400 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:24.815007 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:24.839259 B40192766 Read-Ack Boiler water temperature: 39.40 | |
15:45:25.636178 T00630000 Read-Data Message ID 99: 0 | |
15:45:25.663513 R80790000 Read-Data CH pump operation hours: 0 | |
15:45:25.769136 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:45:25.794886 AF0630000 Unk-DataId Message ID 99: 0 | |
15:45:26.604191 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:26.766615 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:27.618012 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:27.764210 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:28.934925 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:28.955069 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:29.729584 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:29.796234 B40192766 Read-Ack Boiler water temperature: 39.40 | |
15:45:30.401543 Command: TC=20.00 | |
15:45:30.490973 TC: 20.00 | |
15:45:30.638257 T00780000 Read-Data Burner operation hours: 0 | |
15:45:30.765456 B4078153C Read-Ack Burner operation hours: 5436 | |
15:45:31.780714 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:31.980849 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:32.654025 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:32.780687 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:33.813873 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:33.834077 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:35.065127 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:35.086897 BC019274C Read-Ack Boiler water temperature: 39.30 | |
15:45:35.873909 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:45:35.887788 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:45:37.104686 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:37.293898 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:37.697685 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:37.794274 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:38.742225 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:38.857919 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:39.909320 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:39.929079 B40192733 Read-Ack Boiler water temperature: 39.20 | |
15:45:40.793842 T001B0000 Read-Data Outside temperature: 0.00 | |
15:45:40.813392 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:45:40.848523 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:45:40.864826 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:45:41.739323 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:41.936873 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:42.862837 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:42.881170 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:43.752764 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:43.854376 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:44.498358 Command: TC=20.60 | |
15:45:44.572763 TC: 20.60 | |
15:45:44.757009 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:44.854822 BC0192719 Read-Ack Boiler water temperature: 39.10 | |
15:45:45.830223 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:45:45.850234 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:45:46.773703 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:46.918848 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:47.789010 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:47.845571 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:48.790788 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:48.955566 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:49.804837 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:49.958192 BC01926F3 Read-Ack Boiler water temperature: 38.95 | |
15:45:51.004084 T90101500 Write-Data Room setpoint: 21.00 | |
15:45:51.029456 B50101500 Write-Ack Room setpoint: 21.00 | |
15:45:51.824378 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:52.085533 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:52.855817 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:52.957910 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:53.898591 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:53.957469 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:45:55.149192 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:45:55.169448 B401926E6 Read-Ack Boiler water temperature: 38.90 | |
15:45:55.195616 Command: TC=20.50 | |
15:45:55.305893 TC: 20.50 | |
15:45:55.971766 T10181330 Write-Data Room temperature: 19.19 | |
15:45:55.986503 BD0181330 Write-Ack Room temperature: 19.19 | |
15:45:56.854670 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:45:57.109205 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:45:57.868736 T10015A00 Write-Data Control setpoint: 90.00 | |
15:45:57.969911 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:45:59.222744 T00110000 Read-Data Relative modulation level: 0.00 | |
15:45:59.242650 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:00.007402 Command: SC=15:46/6 | |
15:46:00.032814 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:00.068579 B4019270C Read-Ack Boiler water temperature: 39.05 | |
15:46:00.896614 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:46:00.915317 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:46:01.069903 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:46:01.090696 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:46:01.891469 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:46:01.911585 R00740000 Read-Data Burner starts: 0 | |
15:46:02.046365 BC074FFFF Read-Ack Burner starts: 65535 | |
15:46:02.067522 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:46:02.899020 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:46:02.919696 R80750000 Read-Data CH pump starts: 0 | |
15:46:03.048518 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:46:03.071198 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:46:04.159432 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:04.347237 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:04.957163 T10015A00 Write-Data Control setpoint: 90.00 | |
15:46:05.052324 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:46:05.930798 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:06.042987 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:07.004999 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:07.069549 BC0192740 Read-Ack Boiler water temperature: 39.25 | |
15:46:07.938727 T00630000 Read-Data Message ID 99: 0 | |
15:46:07.962384 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:46:08.045398 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:46:08.058348 AF0630000 Unk-DataId Message ID 99: 0 | |
15:46:09.059616 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:09.301989 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:10.284244 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:10.303815 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:11.101611 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:46:11.121963 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:46:11.968860 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:12.059583 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:13.156279 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:13.168676 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:14.377800 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:14.398013 B40192733 Read-Ack Boiler water temperature: 39.20 | |
15:46:15.197156 T007B0000 Read-Data DHW burner operation hours: 0 | |
15:46:15.207907 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:46:16.027299 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:16.182426 BC0000202 Read-Ack Status: 00000010 00000010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:17.245850 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:17.383460 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:18.064688 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:18.202240 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:19.293350 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:19.402338 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:20.112641 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:20.156512 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:21.047234 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:21.158993 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:22.058805 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:22.152073 BC01922E3 Read-Ack Boiler water temperature: 34.89 | |
15:46:23.071847 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:46:23.228166 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:46:24.209782 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:24.339599 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:25.085664 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:25.232113 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:26.095802 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:26.230154 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:27.112050 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:27.228562 BC01920F5 Read-Ack Boiler water temperature: 32.96 | |
15:46:28.118140 T001B0000 Read-Data Outside temperature: 0.00 | |
15:46:28.137397 R00770000 Read-Data DHW burner starts: 0 | |
15:46:28.237141 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:46:28.248545 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:46:29.534077 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:29.697995 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:30.353981 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:30.373518 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:31.173620 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:31.224799 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:32.344850 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:32.364568 BC0192028 Read-Ack Boiler water temperature: 32.16 | |
15:46:33.220546 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:46:33.285311 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:46:34.173899 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:34.335784 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:35.272773 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:35.333451 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:36.501370 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:36.520396 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:37.315834 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:37.334683 BC0191FEE Read-Ack Boiler water temperature: 31.93 | |
15:46:38.545913 T10100A00 Write-Data Room setpoint: 10.00 | |
15:46:38.566562 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:46:39.776797 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:39.910771 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:40.237322 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:40.346014 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:41.687381 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:41.705912 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:42.643747 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:42.663801 B40191FE6 Read-Ack Boiler water temperature: 31.90 | |
15:46:43.460581 T10181330 Write-Data Room temperature: 19.19 | |
15:46:43.489034 BD0181330 Write-Ack Room temperature: 19.19 | |
15:46:44.281134 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:44.577970 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:45.277877 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:45.434026 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:46.328528 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:46.434013 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:47.287802 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:47.431981 B40191FE6 Read-Ack Boiler water temperature: 31.90 | |
15:46:48.378107 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:46:48.399421 R00780000 Read-Data Burner operation hours: 0 | |
15:46:48.436045 B4078153C Read-Ack Burner operation hours: 5436 | |
15:46:48.475062 A40091480 Read-Ack Remote override room setpoint: 20.50 | |
15:46:49.303951 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:46:49.312205 R80790000 Read-Data CH pump operation hours: 0 | |
15:46:49.437813 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:46:49.459761 A40091480 Read-Ack Remote override room setpoint: 20.50 | |
15:46:50.315729 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:46:50.338872 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:46:50.431615 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:46:50.444418 A40091480 Read-Ack Remote override room setpoint: 20.50 | |
15:46:51.327018 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:51.577013 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:52.334702 T10010600 Write-Data Control setpoint: 6.00 | |
15:46:52.432716 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:46:53.343996 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:53.435904 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:54.351339 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:54.517830 B40191FFD Read-Ack Boiler water temperature: 31.99 | |
15:46:55.360164 T00630000 Read-Data Message ID 99: 0 | |
15:46:55.373430 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:46:55.512985 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:46:55.522446 AF0630000 Unk-DataId Message ID 99: 0 | |
15:46:56.569669 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:46:56.825717 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:46:57.387222 T9001334C Write-Data Control setpoint: 51.30 | |
15:46:57.523098 B5001334C Write-Ack Control setpoint: 51.30 | |
15:46:58.384321 T00110000 Read-Data Relative modulation level: 0.00 | |
15:46:58.513295 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:46:59.436326 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:46:59.480867 BC0192000 Read-Ack Boiler water temperature: 32.00 | |
15:47:00.011348 Command: SC=15:47/6 | |
15:47:00.198420 SC: 15:47/6 | |
15:47:00.403398 T806D0000 Read-Data Message ID 109: 0 | |
15:47:00.410601 R00740000 Read-Data Burner starts: 0 | |
15:47:00.514877 BC074FFFF Read-Ack Burner starts: 65535 | |
15:47:00.551230 A706D0000 Unk-DataId Message ID 109: 0 | |
15:47:01.428157 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:01.659125 BC0000300 Read-Ack Status: 00000011 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:02.424013 T9001334C Write-Data Control setpoint: 51.30 | |
15:47:02.515037 B5001334C Write-Ack Control setpoint: 51.30 | |
15:47:03.424664 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:03.520487 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:04.455247 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:04.512651 BC0192000 Read-Ack Boiler water temperature: 32.00 | |
15:47:05.580629 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:47:05.600086 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:47:06.809562 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:06.940551 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:07.628488 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:07.792913 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:08.857036 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:08.966584 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:09.677908 T9001334C Write-Data Control setpoint: 51.30 | |
15:47:09.699714 B5001334C Write-Ack Control setpoint: 51.30 | |
15:47:10.907259 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:10.925840 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:11.507165 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:11.615607 B401925D9 Read-Ack Boiler water temperature: 37.85 | |
15:47:12.543415 T001B0000 Read-Data Outside temperature: 0.00 | |
15:47:12.560689 R80750000 Read-Data CH pump starts: 0 | |
15:47:12.589155 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:47:12.630818 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:47:13.528346 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:13.661966 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:14.591709 T10013366 Write-Data Control setpoint: 51.40 | |
15:47:14.611245 BD0013366 Write-Ack Control setpoint: 51.40 | |
15:47:15.824698 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:47:15.845728 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:47:16.644230 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:16.664654 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:17.717345 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:17.738103 B4019281E Read-Ack Boiler water temperature: 40.12 | |
15:47:18.687920 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:47:18.708835 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:47:19.916453 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:20.050134 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:20.737420 T10015A00 Write-Data Control setpoint: 90.00 | |
15:47:20.757763 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:47:21.554148 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:21.646429 Medium power | |
15:47:22.719016 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:22.738789 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:23.605029 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:23.625647 BC019284C Read-Ack Boiler water temperature: 40.30 | |
15:47:24.545922 T90101480 Write-Data Room setpoint: 20.50 | |
15:47:24.632196 B50101480 Write-Ack Room setpoint: 20.50 | |
15:47:25.656209 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:25.789501 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:26.549176 T10015A00 Write-Data Control setpoint: 90.00 | |
15:47:26.657694 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:47:27.543360 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:27.632685 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:28.927427 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:28.951895 BC0192868 Read-Ack Boiler water temperature: 40.41 | |
15:47:29.747341 T10181335 Write-Data Room temperature: 19.21 | |
15:47:29.774794 BD0181335 Write-Ack Room temperature: 19.21 | |
15:47:30.565592 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:30.701223 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:31.795722 T10015A00 Write-Data Control setpoint: 90.00 | |
15:47:31.814557 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:47:32.614577 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:32.633983 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:33.842152 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:33.862041 BC0192880 Read-Ack Boiler water temperature: 40.50 | |
15:47:34.661146 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:47:34.682654 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:47:34.717775 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:47:34.741303 A40091480 Read-Ack Remote override room setpoint: 20.50 | |
15:47:35.891441 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:36.013736 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:36.709448 T10015A00 Write-Data Control setpoint: 90.00 | |
15:47:36.731711 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:47:37.119348 Low power | |
15:47:37.735234 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:37.755790 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:38.787918 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:38.811484 B40192866 Read-Ack Boiler water temperature: 40.40 | |
15:47:39.600044 T00630000 Read-Data Message ID 99: 0 | |
15:47:39.619570 R00770000 Read-Data DHW burner starts: 0 | |
15:47:39.693854 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:47:39.700836 AF0630000 Unk-DataId Message ID 99: 0 | |
15:47:40.811132 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:40.938307 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:41.624799 T10015A00 Write-Data Control setpoint: 90.00 | |
15:47:41.670397 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:47:42.741129 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:42.769362 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:43.674618 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:43.695595 BC019284C Read-Ack Boiler water temperature: 40.30 | |
15:47:44.830561 T806E0000 Read-Data Message ID 110: 0 | |
15:47:44.852569 R00780000 Read-Data Burner operation hours: 0 | |
15:47:44.881162 B4078153C Read-Ack Burner operation hours: 5436 | |
15:47:44.899537 A706E0000 Unk-DataId Message ID 110: 0 | |
15:47:45.724552 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:45.933525 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:46.825622 T10015A00 Write-Data Control setpoint: 90.00 | |
15:47:46.847879 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:47:47.749774 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:47.769981 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:48.587823 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:48.689746 B40192833 Read-Ack Boiler water temperature: 40.20 | |
15:47:49.818543 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:47:49.839205 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:47:50.565533 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:50.694025 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:51.784756 T10015A00 Write-Data Control setpoint: 90.00 | |
15:47:51.803795 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:47:52.671578 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:52.689686 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:53.566769 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:53.695428 B40192833 Read-Ack Boiler water temperature: 40.20 | |
15:47:54.731888 T001B0000 Read-Data Outside temperature: 0.00 | |
15:47:54.756371 R80790000 Read-Data CH pump operation hours: 0 | |
15:47:54.778927 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:47:54.796853 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:47:55.602739 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:47:55.873222 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:47:56.276043 Command: SC=15:47/6 | |
15:47:56.283661 Command: SR=21:02,08 | |
15:47:56.295651 Command: SR=22:7,228 | |
15:47:56.372206 SC: 15:47/6 | |
15:47:56.567672 T10015A00 Write-Data Control setpoint: 90.00 | |
15:47:56.691140 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:47:57.601801 T00110000 Read-Data Relative modulation level: 0.00 | |
15:47:57.691194 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:47:58.571542 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:47:58.690977 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:47:59.667991 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:47:59.688115 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:48:00.007940 Command: SC=15:48/6 | |
15:48:00.124287 SC: 15:48/6 | |
15:48:00.573932 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:00.826818 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:01.698399 T10015A00 Write-Data Control setpoint: 90.00 | |
15:48:01.716241 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:48:02.823687 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:02.842508 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:03.576187 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:03.691023 B40192800 Read-Ack Boiler water temperature: 40.00 | |
15:48:05.006279 T90101480 Write-Data Room setpoint: 20.50 | |
15:48:05.027245 B50101480 Write-Ack Room setpoint: 20.50 | |
15:48:05.577837 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:05.828804 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:06.616428 T10015A00 Write-Data Control setpoint: 90.00 | |
15:48:06.673777 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:48:06.962856 Command: TC=20.00 | |
15:48:07.086071 TC: 20.00 | |
15:48:07.831951 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:07.851628 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:08.659316 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:08.678162 B40192800 Read-Ack Boiler water temperature: 40.00 | |
15:48:09.822916 T1018133A Write-Data Room temperature: 19.23 | |
15:48:09.842604 BD018133A Write-Ack Room temperature: 19.23 | |
15:48:10.916118 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:11.081134 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:11.576182 T10015A00 Write-Data Control setpoint: 90.00 | |
15:48:11.694062 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:48:12.754626 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:12.772692 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:13.654707 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:13.719709 BC0192819 Read-Ack Boiler water temperature: 40.10 | |
15:48:14.574274 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:48:14.595840 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:48:14.678214 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:48:14.700988 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:48:15.632516 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:48:15.656563 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:48:15.696551 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:48:15.715610 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:48:16.579216 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:48:16.600392 R00740000 Read-Data Burner starts: 0 | |
15:48:16.682094 BC074FFFF Read-Ack Burner starts: 65535 | |
15:48:16.704239 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:48:17.671101 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:18.047090 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:18.573829 T10015A00 Write-Data Control setpoint: 90.00 | |
15:48:18.677280 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:48:19.718510 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:19.741870 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:20.950986 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:20.975947 BC019284C Read-Ack Boiler water temperature: 40.30 | |
15:48:21.766425 T00630000 Read-Data Message ID 99: 0 | |
15:48:21.787601 R80750000 Read-Data CH pump starts: 0 | |
15:48:21.821529 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:48:21.846374 AF0630000 Unk-DataId Message ID 99: 0 | |
15:48:22.587279 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:22.717769 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:23.573920 T10015A00 Write-Data Control setpoint: 90.00 | |
15:48:23.677274 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:48:24.634859 T10010600 Write-Data Control setpoint: 6.00 | |
15:48:24.685115 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:48:25.863351 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:48:25.884155 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:48:26.681206 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:26.701559 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:27.857601 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:27.878658 B40192866 Read-Ack Boiler water temperature: 40.40 | |
15:48:28.730751 T006F0000 Read-Data Message ID 111: 0 | |
15:48:28.752113 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:48:28.788893 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:48:28.826830 AF06F0000 Unk-DataId Message ID 111: 0 | |
15:48:29.959264 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:30.094789 BC0000202 Read-Ack Status: 00000010 00000010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:30.809940 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:30.939315 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:31.637177 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:31.758568 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:32.825033 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:32.945733 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:33.646287 T10010600 Write-Data Control setpoint: 6.00 | |
15:48:33.662815 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:48:34.876057 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:34.895730 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:35.693284 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:35.711440 BC0192473 Read-Ack Boiler water temperature: 36.45 | |
15:48:36.922613 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:48:36.940233 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:48:37.740187 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:37.870426 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:38.971417 T10010600 Write-Data Control setpoint: 6.00 | |
15:48:38.998234 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:48:39.789478 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:39.809294 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:40.619574 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:40.680641 BC0192251 Read-Ack Boiler water temperature: 34.32 | |
15:48:41.576624 T001B0000 Read-Data Outside temperature: 0.00 | |
15:48:41.594855 R00770000 Read-Data DHW burner starts: 0 | |
15:48:41.681920 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:48:41.704828 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:48:42.656967 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:42.959969 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:43.577607 T10010600 Write-Data Control setpoint: 6.00 | |
15:48:43.669403 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:48:44.587920 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:44.680274 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:45.572790 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:45.674032 BC0192154 Read-Ack Boiler water temperature: 33.33 | |
15:48:46.756534 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:48:46.796790 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:48:47.571512 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:47.838490 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:48.801236 T10010600 Write-Data Control setpoint: 6.00 | |
15:48:48.826166 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:48:49.619944 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:49.696421 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:50.579896 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:50.676487 B40192100 Read-Ack Boiler water temperature: 33.00 | |
15:48:51.667272 T10100A00 Write-Data Room setpoint: 10.00 | |
15:48:51.686328 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:48:52.619159 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:52.778237 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:53.677385 T10010600 Write-Data Control setpoint: 6.00 | |
15:48:53.766531 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:48:54.700424 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:54.759647 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:48:55.672695 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:48:55.762604 B401920E6 Read-Ack Boiler water temperature: 32.90 | |
15:48:57.013657 T90181345 Write-Data Room temperature: 19.27 | |
15:48:57.032463 B50181345 Write-Ack Room temperature: 19.27 | |
15:48:57.643921 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:48:57.774374 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:48:58.667721 T10010600 Write-Data Control setpoint: 6.00 | |
15:48:58.767677 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:48:59.654136 T00110000 Read-Data Relative modulation level: 0.00 | |
15:48:59.765976 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:00.000556 Command: SC=15:49/6 | |
15:49:00.126856 SC: 15:49/6 | |
15:49:00.665290 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:00.767936 B401920E6 Read-Ack Boiler water temperature: 32.90 | |
15:49:01.841406 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:49:01.859976 R00780000 Read-Data Burner operation hours: 0 | |
15:49:01.893186 B4078153C Read-Ack Burner operation hours: 5436 | |
15:49:01.913006 AC0091400 Read-Ack Remote override room setpoint: 20.00 | |
15:49:02.677540 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:49:02.697524 R80790000 Read-Data CH pump operation hours: 0 | |
15:49:02.771167 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:49:02.797005 AC0091400 Read-Ack Remote override room setpoint: 20.00 | |
15:49:03.686336 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:49:03.706426 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:49:03.782975 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:49:03.809387 AC0091400 Read-Ack Remote override room setpoint: 20.00 | |
15:49:04.773875 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:04.901294 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:06.003295 T10012799 Write-Data Control setpoint: 39.60 | |
15:49:06.025861 BD0012799 Write-Ack Control setpoint: 39.60 | |
15:49:06.822285 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:06.867079 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:07.896158 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:07.918287 B40192100 Read-Ack Boiler water temperature: 33.00 | |
15:49:08.871614 T00630000 Read-Data Message ID 99: 0 | |
15:49:08.897409 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:49:08.925011 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:49:08.946945 AF0630000 Unk-DataId Message ID 99: 0 | |
15:49:10.122347 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:10.283545 BC0000300 Read-Ack Status: 00000011 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:10.777825 T10012799 Write-Data Control setpoint: 39.60 | |
15:49:10.867919 BD0012799 Write-Ack Control setpoint: 39.60 | |
15:49:11.749277 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:11.871126 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:12.901721 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:12.923580 B40192100 Read-Ack Boiler water temperature: 33.00 | |
15:49:13.785985 T80700000 Read-Data Message ID 112: 0 | |
15:49:13.793136 R00740000 Read-Data Burner starts: 0 | |
15:49:13.861630 BC074FFFF Read-Ack Burner starts: 65535 | |
15:49:13.898414 A70700000 Unk-DataId Message ID 112: 0 | |
15:49:15.015557 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:15.163758 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:15.837217 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:16.003308 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:17.062235 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:17.209244 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:17.892128 T10012799 Write-Data Control setpoint: 39.60 | |
15:49:17.947343 BD0012799 Write-Ack Control setpoint: 39.60 | |
15:49:19.111114 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:19.117586 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:19.928633 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:19.935147 BC01926D4 Read-Ack Boiler water temperature: 38.83 | |
15:49:21.160041 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:49:21.166320 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:49:21.985405 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:22.138796 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:22.847904 T10012799 Write-Data Control setpoint: 39.60 | |
15:49:22.948868 BD0012799 Write-Ack Control setpoint: 39.60 | |
15:49:23.855768 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:23.953684 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:24.865986 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:49:24.954619 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:49:26.075869 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:26.094972 B401928F0 Read-Ack Boiler water temperature: 40.94 | |
15:49:26.893986 T001B0000 Read-Data Outside temperature: 0.00 | |
15:49:26.913022 R80750000 Read-Data CH pump starts: 0 | |
15:49:26.945566 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:49:26.992824 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:49:27.934171 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:28.062037 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:28.941190 T10015A00 Write-Data Control setpoint: 90.00 | |
15:49:29.051253 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:49:29.966125 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:30.058853 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:30.906650 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:31.051635 BC0192933 Read-Ack Boiler water temperature: 41.20 | |
15:49:32.247874 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:49:32.268810 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:49:32.924816 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:33.225909 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:33.932635 T10015A00 Write-Data Control setpoint: 90.00 | |
15:49:34.052431 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:49:34.942990 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:35.051362 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:35.947770 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:36.051676 BC0192966 Read-Ack Boiler water temperature: 41.40 | |
15:49:37.156718 T10101400 Write-Data Room setpoint: 20.00 | |
15:49:37.176742 BD0101400 Write-Ack Room setpoint: 20.00 | |
15:49:37.963901 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:38.277303 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:39.183340 T10015A00 Write-Data Control setpoint: 90.00 | |
15:49:39.202656 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:49:40.003451 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:40.136385 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:41.240542 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:41.266556 B40192980 Read-Ack Boiler water temperature: 41.50 | |
15:49:42.091951 T90181345 Write-Data Room temperature: 19.27 | |
15:49:42.154829 B50181345 Write-Ack Room temperature: 19.27 | |
15:49:43.007341 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:43.190392 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:44.015936 T10015A00 Write-Data Control setpoint: 90.00 | |
15:49:44.135421 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:49:45.022985 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:45.140698 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:46.032189 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:46.136814 B40192980 Read-Ack Boiler water temperature: 41.50 | |
15:49:47.040059 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:49:47.061575 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:49:47.135887 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:49:47.148302 AC0091400 Read-Ack Remote override room setpoint: 20.00 | |
15:49:48.048310 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:48.258712 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:49.081031 T10015A00 Write-Data Control setpoint: 90.00 | |
15:49:49.165642 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:49:50.067083 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:50.159698 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:51.470919 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:51.491452 B40192980 Read-Ack Boiler water temperature: 41.50 | |
15:49:52.293495 T00630000 Read-Data Message ID 99: 0 | |
15:49:52.320691 R00770000 Read-Data DHW burner starts: 0 | |
15:49:52.374747 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:49:52.420641 AF0630000 Unk-DataId Message ID 99: 0 | |
15:49:53.086584 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:53.365536 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:54.094687 T10015A00 Write-Data Control setpoint: 90.00 | |
15:49:54.235292 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:49:55.174142 T00110000 Read-Data Relative modulation level: 0.00 | |
15:49:55.252420 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:49:56.111685 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:49:56.237816 BC0192963 Read-Ack Boiler water temperature: 41.39 | |
15:49:57.125961 T1002010B Write-Data Master configuration: 00000001 11 | |
- Smart power: supported (1) | |
15:49:57.254550 BD002010B Write-Ack Master configuration: 00000001 11 | |
- Smart power: supported (1) | |
15:49:58.130227 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:49:58.237485 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:49:59.136206 T10015A00 Write-Data Control setpoint: 90.00 | |
15:49:59.239502 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:00.000780 Command: SC=15:50/6 | |
15:50:00.148521 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:00.171067 SC: 15:50/6 | |
15:50:00.246655 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:01.191372 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:01.252314 B4019294C Read-Ack Boiler water temperature: 41.30 | |
15:50:02.162141 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:50:02.255210 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:50:03.172580 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:04.359282 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:04.500451 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:04.510028 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:05.187074 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:05.324117 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:06.197468 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:06.336356 BC0192933 Read-Ack Boiler water temperature: 41.20 | |
15:50:07.445468 T001B0000 Read-Data Outside temperature: 0.00 | |
15:50:07.477624 R00780000 Read-Data Burner operation hours: 0 | |
15:50:07.525083 B4078153C Read-Ack Burner operation hours: 5436 | |
15:50:07.557465 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:50:08.213053 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:08.557642 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:09.355474 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:09.378132 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:10.313386 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:10.331877 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:11.502582 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:11.509371 B40192919 Read-Ack Boiler water temperature: 41.10 | |
15:50:12.360159 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:50:12.385281 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:50:13.590655 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:13.723881 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:14.407131 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:14.415951 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:15.666655 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:15.684570 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:16.284483 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:16.459289 B40192919 Read-Ack Boiler water temperature: 41.10 | |
15:50:17.684819 T10101400 Write-Data Room setpoint: 20.00 | |
15:50:17.705333 BD0101400 Write-Ack Room setpoint: 20.00 | |
15:50:18.514779 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:18.695553 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:19.323930 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:19.422211 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:20.559162 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:20.587198 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:21.371325 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:21.419575 B40192919 Read-Ack Boiler water temperature: 41.10 | |
15:50:22.601022 T9018134C Write-Data Room temperature: 19.30 | |
15:50:22.625432 B5018134C Write-Ack Room temperature: 19.30 | |
15:50:23.420896 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:23.564863 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:24.648728 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:24.667656 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:25.878345 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:25.898312 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:26.696533 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:26.716579 B4019294C Read-Ack Boiler water temperature: 41.30 | |
15:50:27.515943 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:50:27.538901 R80790000 Read-Data CH pump operation hours: 0 | |
15:50:27.577875 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:50:27.613341 AC0091400 Read-Ack Remote override room setpoint: 20.00 | |
15:50:28.376756 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:28.703212 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:29.389557 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:29.523553 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:30.793048 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:30.813659 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:31.397599 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:31.527185 BC0192966 Read-Ack Boiler water temperature: 41.40 | |
15:50:32.431897 T00630000 Read-Data Message ID 99: 0 | |
15:50:32.454616 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:50:32.537251 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:50:32.559634 AF0630000 Unk-DataId Message ID 99: 0 | |
15:50:33.415665 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:33.619008 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:34.484358 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:34.555928 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:35.708037 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:35.729063 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:36.526401 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:36.548784 B40192980 Read-Ack Boiler water temperature: 41.50 | |
15:50:37.448961 T00030000 Read-Data Slave configuration: 00000000 0 | |
15:50:37.541588 B4003410B Read-Ack Slave configuration: 01000001 11 | |
- DHW: present (1) | |
- Control type: modulating (0) | |
- Cooling: not supported (0) | |
- DHW: instantaneous (0) | |
- Master pump control: allowed (0) | |
- CH2: not present (0) | |
- Remote water filling: not available (1) | |
- Heat/cool mode control: heat (0) | |
15:50:38.575783 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:38.697135 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:39.832657 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:39.852104 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:40.729360 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:40.748578 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:41.479829 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:41.606634 BC01929CC Read-Ack Boiler water temperature: 41.80 | |
15:50:42.671502 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:50:42.703756 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:50:43.846310 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:44.144466 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:44.737032 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:44.762522 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:45.541335 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:45.603654 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:46.766421 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:46.801290 BC01929D1 Read-Ack Boiler water temperature: 41.82 | |
15:50:47.588577 T001B0000 Read-Data Outside temperature: 0.00 | |
15:50:47.613111 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:50:47.677458 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:50:47.733306 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:50:48.820856 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:49.156346 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:49.655284 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:49.700030 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:50.865225 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:50.884036 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:51.691529 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:51.711484 BC0192A00 Read-Ack Boiler water temperature: 42.00 | |
15:50:52.565327 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:50:52.707724 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:50:53.730117 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:53.855200 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:54.581302 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:54.708522 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:50:55.593569 T00110000 Read-Data Relative modulation level: 0.00 | |
15:50:55.708557 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:50:56.597454 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:50:56.706122 BC0192A05 Read-Ack Boiler water temperature: 42.02 | |
15:50:57.826690 T10101400 Write-Data Room setpoint: 20.00 | |
15:50:57.847524 BD0101400 Write-Ack Room setpoint: 20.00 | |
15:50:58.648838 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:50:58.823327 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:50:59.883015 T10015A00 Write-Data Control setpoint: 90.00 | |
15:50:59.902736 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:00.007979 Command: SC=15:51/6 | |
15:51:00.140421 SC: 15:51/6 | |
15:51:01.342988 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:01.362160 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:01.646761 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:01.736963 BC0192A33 Read-Ack Boiler water temperature: 42.20 | |
15:51:02.646777 T90181351 Write-Data Room temperature: 19.32 | |
15:51:02.809551 B50181351 Write-Ack Room temperature: 19.32 | |
15:51:03.653229 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:03.824529 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:04.793384 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:04.813028 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:05.846205 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:05.868361 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:06.820335 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:06.844956 B40192A3D Read-Ack Boiler water temperature: 42.24 | |
15:51:07.688869 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:51:07.710409 R00740000 Read-Data Burner starts: 0 | |
15:51:07.807523 BC074FFFF Read-Ack Burner starts: 65535 | |
15:51:07.830408 AC0091400 Read-Ack Remote override room setpoint: 20.00 | |
15:51:08.101076 Command: TC=22.00 | |
15:51:08.209862 TC: 22.00 | |
15:51:08.885975 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:08.997467 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:10.114647 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:10.136089 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:10.942611 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:10.968305 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:11.753654 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:11.819624 B40192A4C Read-Ack Boiler water temperature: 42.30 | |
15:51:12.982259 T00630000 Read-Data Message ID 99: 0 | |
15:51:13.002976 R80750000 Read-Data CH pump starts: 0 | |
15:51:13.040361 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:51:13.075205 AF0630000 Unk-DataId Message ID 99: 0 | |
15:51:13.800647 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:14.073544 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:14.739419 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:14.886924 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:15.850623 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:15.912089 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:16.756803 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:16.907406 B40192A80 Read-Ack Boiler water temperature: 42.50 | |
15:51:17.896399 T00120000 Read-Data CH water pressure: 0.00 | |
15:51:17.918710 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:51:17.954330 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:51:17.991704 AF0120000 Unk-DataId CH water pressure: 0.00 | |
15:51:18.862946 Command: TC=22.00 | |
15:51:18.911762 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:19.004716 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:19.974309 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:19.994431 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:20.796037 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:20.887527 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:21.993139 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:22.012436 BC0192A99 Read-Ack Boiler water temperature: 42.60 | |
15:51:23.081535 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:51:23.102027 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:51:24.041466 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:24.195667 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:24.860329 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:24.995809 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:25.843022 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:25.990027 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:26.908062 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:26.999459 BC0192A99 Read-Ack Boiler water temperature: 42.60 | |
15:51:28.092255 T001B0000 Read-Data Outside temperature: 0.00 | |
15:51:28.115044 R00770000 Read-Data DHW burner starts: 0 | |
15:51:28.152625 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:51:28.187289 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:51:28.863594 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:29.190905 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:30.188104 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:30.222508 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:31.005136 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:31.027233 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:31.888809 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:31.992333 B40192AB3 Read-Ack Boiler water temperature: 42.70 | |
15:51:33.081264 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:51:33.102910 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:51:34.292073 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:34.455333 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:35.099770 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:35.121457 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:36.105427 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:36.125116 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:37.240067 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:37.264517 BC0192ACC Read-Ack Boiler water temperature: 42.80 | |
15:51:37.969124 T10101400 Write-Data Room setpoint: 20.00 | |
15:51:38.102750 BD0101400 Write-Ack Room setpoint: 20.00 | |
15:51:39.199804 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:39.331634 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:40.019518 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:40.067129 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:40.980839 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:41.083615 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:42.063570 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:42.088249 B40192AE6 Read-Ack Boiler water temperature: 42.90 | |
15:51:43.105697 T90181351 Write-Data Room temperature: 19.32 | |
15:51:43.127163 B50181351 Write-Ack Room temperature: 19.32 | |
15:51:43.981902 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:44.310453 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:44.995446 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:45.093404 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:45.997458 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:46.093244 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:47.011541 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:47.101115 B40192AE6 Read-Ack Boiler water temperature: 42.90 | |
15:51:48.109817 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:51:48.136186 R00780000 Read-Data Burner operation hours: 0 | |
15:51:48.165008 B4078153C Read-Ack Burner operation hours: 5436 | |
15:51:48.186453 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:51:49.438004 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:51:49.470860 R80790000 Read-Data CH pump operation hours: 0 | |
15:51:49.526069 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:51:49.556290 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:51:50.256052 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:51:50.277923 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:51:50.317545 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:51:50.355064 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:51:51.074461 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:51.280617 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:52.303674 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:52.325420 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:53.059577 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:53.192100 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:54.351631 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:54.374808 B40192B00 Read-Ack Boiler water temperature: 43.00 | |
15:51:55.170997 T00630000 Read-Data Message ID 99: 0 | |
15:51:55.192824 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:51:55.232909 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:51:55.274967 AF0630000 Unk-DataId Message ID 99: 0 | |
15:51:56.097760 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:51:56.343197 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:51:57.088162 T10015A00 Write-Data Control setpoint: 90.00 | |
15:51:57.180289 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:51:58.092385 T00110000 Read-Data Relative modulation level: 0.00 | |
15:51:58.185298 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:51:59.101025 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:51:59.196768 BC0192B19 Read-Ack Boiler water temperature: 43.10 | |
15:52:00.008294 Command: SC=15:52/6 | |
15:52:00.117566 T10010600 Write-Data Control setpoint: 6.00 | |
15:52:00.134614 SC: 15:52/6 | |
15:52:00.208601 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:52:01.315372 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:52:01.337984 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:52:02.137301 T801A0000 Read-Data DHW temperature: 0.00 | |
15:52:02.185949 R00740000 Read-Data Burner starts: 0 | |
15:52:02.302788 BC074FFFF Read-Ack Burner starts: 65535 | |
15:52:02.327353 A701A0000 Unk-DataId DHW temperature: 0.00 | |
15:52:03.161986 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:03.280649 BC0000202 Read-Ack Status: 00000010 00000010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:04.144689 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:04.366602 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:05.148875 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:05.453221 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:06.160610 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:06.435966 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:07.169069 T10010600 Write-Data Control setpoint: 6.00 | |
15:52:07.260286 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:52:08.173659 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:08.268018 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:09.183449 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:09.275922 BC0192840 Read-Ack Boiler water temperature: 40.25 | |
15:52:10.349577 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:52:10.373062 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:52:11.196304 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:11.415775 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:12.375180 T10010600 Write-Data Control setpoint: 6.00 | |
15:52:12.417650 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:52:13.213995 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:13.362106 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:14.423696 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:14.444952 BC01925A6 Read-Ack Boiler water temperature: 37.65 | |
15:52:15.232776 T001B0000 Read-Data Outside temperature: 0.00 | |
15:52:15.252468 R80750000 Read-Data CH pump starts: 0 | |
15:52:15.366427 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:52:15.386121 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:52:16.478975 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:16.569495 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:17.289963 T10010600 Write-Data Control setpoint: 6.00 | |
15:52:17.347463 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:52:18.253741 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:18.368518 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:19.339135 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:19.365858 B40192430 Read-Ack Boiler water temperature: 36.19 | |
15:52:20.270095 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:52:20.367385 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:52:21.385408 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:21.549961 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:22.615950 T10010600 Write-Data Control setpoint: 6.00 | |
15:52:22.635472 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:52:23.294436 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:23.411861 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:24.303041 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:24.394691 B401923A8 Read-Ack Boiler water temperature: 35.66 | |
15:52:25.483894 T10100A00 Write-Data Room setpoint: 10.00 | |
15:52:25.513499 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:52:26.711117 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:26.847371 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:27.326449 T10010600 Write-Data Control setpoint: 6.00 | |
15:52:27.461325 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:52:28.335115 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:28.451834 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:29.589294 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:29.609821 B40192380 Read-Ack Boiler water temperature: 35.50 | |
15:52:30.399808 T90181354 Write-Data Room temperature: 19.33 | |
15:52:30.448340 B50181354 Write-Ack Room temperature: 19.33 | |
15:52:31.629102 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:31.770332 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:32.445163 T10010600 Write-Data Control setpoint: 6.00 | |
15:52:32.465574 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:52:33.372564 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:33.470698 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:34.497823 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:34.518980 B40192380 Read-Ack Boiler water temperature: 35.50 | |
15:52:35.723236 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:52:35.743639 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:52:35.780847 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:52:35.820172 A40091600 Read-Ack Remote override room setpoint: 22.00 | |
15:52:36.564619 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:52:36.585400 R00770000 Read-Data DHW burner starts: 0 | |
15:52:36.621587 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:52:36.656257 A40091600 Read-Ack Remote override room setpoint: 22.00 | |
15:52:37.404336 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:52:37.425216 R00780000 Read-Data Burner operation hours: 0 | |
15:52:37.556065 B4078153C Read-Ack Burner operation hours: 5436 | |
15:52:37.577012 A40091600 Read-Ack Remote override room setpoint: 22.00 | |
15:52:38.417535 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:38.717904 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:39.825196 T10010600 Write-Data Control setpoint: 6.00 | |
15:52:39.847200 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:52:40.639787 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:40.667076 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:41.469049 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:41.561463 B40192380 Read-Ack Boiler water temperature: 35.50 | |
15:52:42.691781 T00630000 Read-Data Message ID 99: 0 | |
15:52:42.715024 R80790000 Read-Data CH pump operation hours: 0 | |
15:52:42.751030 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:52:42.790750 AF0630000 Unk-DataId Message ID 99: 0 | |
15:52:43.452653 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:43.598376 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:44.726239 T10013900 Write-Data Control setpoint: 57.00 | |
15:52:44.752353 BD0013900 Write-Ack Control setpoint: 57.00 | |
15:52:45.555915 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:45.579252 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:46.481081 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:46.641483 B40192380 Read-Ack Boiler water temperature: 35.50 | |
15:52:47.491357 T001D0000 Read-Data Solar storage temperature: 0.00 | |
15:52:47.515465 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:52:47.648190 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:52:47.669117 AF01D0000 Unk-DataId Solar storage temperature: 0.00 | |
15:52:48.859079 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:49.206807 BC0000300 Read-Ack Status: 00000011 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:49.504931 T10013900 Write-Data Control setpoint: 57.00 | |
15:52:49.681775 BD0013900 Write-Ack Control setpoint: 57.00 | |
15:52:51.291393 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:51.299937 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:51.529584 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:51.657446 BC0192399 Read-Ack Boiler water temperature: 35.60 | |
15:52:52.925746 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:52:52.962277 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:52:53.539657 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:53.801751 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:54.563909 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:54.699391 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:55.551539 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:52:55.675956 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:52:56.560362 T90013919 Write-Data Control setpoint: 57.10 | |
15:52:56.655182 B50013919 Write-Ack Control setpoint: 57.10 | |
15:52:57.568833 T00110000 Read-Data Relative modulation level: 0.00 | |
15:52:57.665541 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:52:58.578347 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:52:58.684946 B4019295E Read-Ack Boiler water temperature: 41.37 | |
15:52:59.585245 T001B0000 Read-Data Outside temperature: 0.00 | |
15:52:59.615785 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:52:59.749212 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:52:59.771502 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:53:00.007549 Command: SC=15:53/6 | |
15:53:00.316254 SC: 15:53/6 | |
15:53:00.594190 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:00.746780 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:01.602235 T90013919 Write-Data Control setpoint: 57.10 | |
15:53:01.752919 B50013919 Write-Ack Control setpoint: 57.10 | |
15:53:02.758825 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:02.785831 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:03.615020 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:03.749538 B40192B42 Read-Ack Boiler water temperature: 43.26 | |
15:53:04.808790 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:53:04.888112 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:53:05.630845 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:53:05.728898 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:53:06.749372 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:07.013492 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:07.670943 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:07.720571 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:08.758030 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:08.783727 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:09.719648 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:09.740355 BC0192BB3 Read-Ack Boiler water temperature: 43.70 | |
15:53:10.672444 T90101600 Write-Data Room setpoint: 22.00 | |
15:53:10.834526 B50101600 Write-Ack Room setpoint: 22.00 | |
15:53:11.770114 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:12.031677 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:13.001389 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:13.027173 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:13.816655 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:13.838590 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:15.073223 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:15.093648 B40192BCF Read-Ack Boiler water temperature: 43.81 | |
15:53:15.896482 T10181359 Write-Data Room temperature: 19.35 | |
15:53:15.918289 BD0181359 Write-Ack Room temperature: 19.35 | |
15:53:16.715099 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:16.856593 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:17.911759 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:17.931293 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:19.141260 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:19.160709 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:19.960112 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:19.990310 BC0192BE6 Read-Ack Boiler water temperature: 43.90 | |
15:53:20.771742 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:53:20.803507 R00740000 Read-Data Burner starts: 0 | |
15:53:20.850919 BC074FFFF Read-Ack Burner starts: 65535 | |
15:53:20.891393 A40091600 Read-Ack Remote override room setpoint: 22.00 | |
15:53:21.753586 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:22.038866 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:22.827024 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:22.845720 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:24.056319 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:24.078195 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:24.874724 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:24.936354 B40192BD4 Read-Ack Boiler water temperature: 43.83 | |
15:53:26.103849 T00630000 Read-Data Message ID 99: 0 | |
15:53:26.124405 R80750000 Read-Data CH pump starts: 0 | |
15:53:26.159448 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:53:26.195068 AF0630000 Unk-DataId Message ID 99: 0 | |
15:53:26.923419 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:27.077066 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:28.174564 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:28.193913 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:29.000903 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:29.030267 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:29.820298 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:29.923570 BC0192BB3 Read-Ack Boiler water temperature: 43.70 | |
15:53:30.897188 T00300000 Read-Data DHW setpoint boundaries: 0 0 | |
15:53:30.925458 BC0303C28 Read-Ack DHW setpoint boundaries: 60 40 | |
15:53:31.838970 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:31.964078 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:32.834403 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:32.935461 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:33.885820 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:33.945995 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:35.114502 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:35.134215 B40192B99 Read-Ack Boiler water temperature: 43.60 | |
15:53:35.934392 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:53:35.954609 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:53:36.863891 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:37.122345 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:37.982857 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:38.036549 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:39.213482 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:39.232827 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:40.031052 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:40.053916 BC0192B80 Read-Ack Boiler water temperature: 43.50 | |
15:53:40.896455 T001B0000 Read-Data Outside temperature: 0.00 | |
15:53:40.918112 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:53:41.030427 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:53:41.049810 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:53:41.905953 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:42.213102 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:43.306142 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:43.326617 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:43.914996 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:44.043735 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:44.922405 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:45.029937 BC0192B4F Read-Ack Boiler water temperature: 43.31 | |
15:53:45.929156 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:53:46.030142 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:53:46.937509 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:47.166769 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:47.482403 Command: TC=21.50 | |
15:53:47.644192 TC: 21.50 | |
15:53:47.954512 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:48.037454 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:49.042226 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:49.061803 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:50.270744 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:50.300187 B40192B33 Read-Ack Boiler water temperature: 43.20 | |
15:53:50.964325 T90101600 Write-Data Room setpoint: 22.00 | |
15:53:51.128347 B50101600 Write-Ack Room setpoint: 22.00 | |
15:53:52.326937 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:52.448886 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:53.138240 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:53.159260 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:53.988706 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:54.108917 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:53:54.997655 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:53:55.114744 B40192B33 Read-Ack Boiler water temperature: 43.20 | |
15:53:56.000914 T90181361 Write-Data Room temperature: 19.38 | |
15:53:56.108365 B50181361 Write-Ack Room temperature: 19.38 | |
15:53:57.004451 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:53:57.128865 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:53:58.054785 T10015A00 Write-Data Control setpoint: 90.00 | |
15:53:58.100759 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:53:59.016436 T00110000 Read-Data Relative modulation level: 0.00 | |
15:53:59.109450 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:00.001322 Command: SC=15:54/6 | |
15:54:00.082024 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:00.104588 BC0192B68 Read-Ack Boiler water temperature: 43.41 | |
15:54:01.029411 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:54:01.052102 R00770000 Read-Data DHW burner starts: 0 | |
15:54:01.157441 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:54:01.186698 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:54:02.151931 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:54:02.176138 R00780000 Read-Data Burner operation hours: 0 | |
15:54:02.218130 B4078153C Read-Ack Burner operation hours: 5436 | |
15:54:02.241035 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:54:03.341303 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:54:03.362170 R80790000 Read-Data CH pump operation hours: 0 | |
15:54:03.395299 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:54:03.419129 AC0090000 Read-Ack Remote override room setpoint: 0.00 | |
15:54:04.052817 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:04.353776 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:05.171417 T10015A00 Write-Data Control setpoint: 90.00 | |
15:54:05.233520 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:54:06.071742 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:06.216599 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:07.096707 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:07.208405 B40192B99 Read-Ack Boiler water temperature: 43.60 | |
15:54:08.083019 T00630000 Read-Data Message ID 99: 0 | |
15:54:08.103801 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:54:08.212226 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:54:08.234747 AF0630000 Unk-DataId Message ID 99: 0 | |
15:54:09.113184 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:09.242834 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:10.096545 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:10.209436 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:11.160216 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:54:11.210108 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:54:12.113251 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:12.216377 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:13.208827 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:13.230107 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:14.438074 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:14.459712 BC0192B7A Read-Ack Boiler water temperature: 43.48 | |
15:54:15.256416 T80310000 Read-Data Max CH setpoint boundaries: 0 0 | |
15:54:15.281010 B40314B14 Read-Ack Max CH setpoint boundaries: 75 20 | |
15:54:16.486481 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:16.671576 BC0000202 Read-Ack Status: 00000010 00000010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:17.304481 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:17.573872 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:18.367790 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:18.480327 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:19.352703 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:19.612720 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:20.602923 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:20.622934 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:21.180003 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:21.311584 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:22.632050 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:22.717481 B40192759 Read-Ack Boiler water temperature: 39.35 | |
15:54:23.190599 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:54:23.306683 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:54:24.197060 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:24.491121 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:25.223265 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:25.312234 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:26.314685 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:26.335442 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:27.218223 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:27.310666 B4019256B Read-Ack Boiler water temperature: 37.42 | |
15:54:28.366527 T001B0000 Read-Data Outside temperature: 0.00 | |
15:54:28.399310 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:54:28.444300 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:54:28.492762 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:54:29.595558 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:29.870421 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:30.239267 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:30.336999 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:31.639916 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:31.663109 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:32.480908 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:32.508643 BC0192494 Read-Ack Boiler water temperature: 36.58 | |
15:54:33.375945 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
15:54:33.397744 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
15:54:34.272718 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:34.549113 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:35.326919 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:35.378168 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:36.381423 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:36.400989 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:37.322139 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:37.365933 B40192466 Read-Ack Boiler water temperature: 36.40 | |
15:54:38.385182 T10100A00 Write-Data Room setpoint: 10.00 | |
15:54:38.406667 BD0100A00 Write-Ack Room setpoint: 10.00 | |
15:54:39.426493 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:39.547319 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:40.655576 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:40.679539 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:41.321450 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:41.412228 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:42.720774 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:42.741389 B40192466 Read-Ack Boiler water temperature: 36.40 | |
15:54:43.389681 T90181361 Write-Data Room temperature: 19.38 | |
15:54:43.490699 B50181361 Write-Ack Room temperature: 19.38 | |
15:54:44.749740 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:45.031502 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:45.570497 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:45.587203 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:46.389546 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:46.493965 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:47.369067 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:47.493538 B40192466 Read-Ack Boiler water temperature: 36.40 | |
15:54:48.395015 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:54:48.416205 R00740000 Read-Data Burner starts: 0 | |
15:54:48.495945 BC074FFFF Read-Ack Burner starts: 65535 | |
15:54:48.520120 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:54:49.664060 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:54:49.685192 R80750000 Read-Data CH pump starts: 0 | |
15:54:49.725032 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:54:49.762026 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:54:50.489096 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:54:50.510747 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:54:50.548136 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:54:50.583982 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:54:51.711458 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:52.023311 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:52.530056 T10010600 Write-Data Control setpoint: 6.00 | |
15:54:52.551169 BD0010600 Write-Ack Control setpoint: 6.00 | |
15:54:53.409957 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:53.501506 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:54.579091 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:54.600209 B40192466 Read-Ack Boiler water temperature: 36.40 | |
15:54:55.812461 T00630000 Read-Data Message ID 99: 0 | |
15:54:55.833856 R00770000 Read-Data DHW burner starts: 0 | |
15:54:55.857078 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:54:55.883446 AF0630000 Unk-DataId Message ID 99: 0 | |
15:54:56.626496 T80000200 Read-Data Status: 00000010 00000000 | |
- CH enable: disabled (0) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:54:56.846113 B40000200 Read-Ack Status: 00000010 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:54:57.438442 T10013880 Write-Data Control setpoint: 56.50 | |
15:54:57.591894 BD0013880 Write-Ack Control setpoint: 56.50 | |
15:54:58.441436 T00110000 Read-Data Relative modulation level: 0.00 | |
15:54:58.593839 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:54:59.525715 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:54:59.571765 BC0192480 Read-Ack Boiler water temperature: 36.50 | |
15:55:00.001095 Command: SC=15:55/6 | |
15:55:00.086336 SC: 15:55/6 | |
15:55:00.461515 T10382800 Write-Data DHW setpoint: 40.00 | |
15:55:00.593136 BD0382800 Write-Ack DHW setpoint: 40.00 | |
15:55:01.560917 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:01.828886 BC0000300 Read-Ack Status: 00000011 00000000 | |
- Fault indication: no fault (0) | |
- CH mode: not active (0) | |
- DHW mode: not active (0) | |
- Flame status: flame off (0) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:02.746306 T10013880 Write-Data Control setpoint: 56.50 | |
15:55:02.765851 BD0013880 Write-Ack Control setpoint: 56.50 | |
15:55:03.479677 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:03.575096 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:04.848672 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:04.871050 BC0192480 Read-Ack Boiler water temperature: 36.50 | |
15:55:05.638667 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:55:05.660046 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:55:06.504093 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:06.625752 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:07.688405 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:07.816326 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:08.526074 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:08.680331 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:09.529833 T10013880 Write-Data Control setpoint: 56.50 | |
15:55:09.677486 BD0013880 Write-Ack Control setpoint: 56.50 | |
15:55:10.553975 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:10.676239 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:11.813379 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:11.832798 B40192A51 Read-Ack Boiler water temperature: 42.32 | |
15:55:12.635905 T001B0000 Read-Data Outside temperature: 0.00 | |
15:55:12.646239 R00780000 Read-Data Burner operation hours: 0 | |
15:55:12.679103 B4078153C Read-Ack Burner operation hours: 5436 | |
15:55:12.690397 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:55:13.557140 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:13.884618 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:14.654417 T90013899 Write-Data Control setpoint: 56.60 | |
15:55:14.674198 B50013899 Write-Ack Control setpoint: 56.60 | |
15:55:15.881537 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:55:15.905292 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:55:16.697922 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:16.718732 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:17.588200 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:17.680282 B40192C57 Read-Ack Boiler water temperature: 44.34 | |
15:55:18.594041 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:55:18.685607 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:55:19.606313 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:19.741854 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:20.793311 T10015A00 Write-Data Control setpoint: 90.00 | |
15:55:20.825361 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:55:22.023374 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:22.051213 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:22.843176 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:22.863845 B40192C80 Read-Ack Boiler water temperature: 44.50 | |
15:55:23.641842 T10101580 Write-Data Room setpoint: 21.50 | |
15:55:23.779979 BD0101580 Write-Ack Room setpoint: 21.50 | |
15:55:24.912365 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:25.219706 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:25.709235 T10015A00 Write-Data Control setpoint: 90.00 | |
15:55:25.754376 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:55:26.660506 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:26.773842 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:27.661886 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:27.776308 BC0192C99 Read-Ack Boiler water temperature: 44.60 | |
15:55:28.698065 T9018136B Write-Data Room temperature: 19.42 | |
15:55:28.743022 B5018136B Write-Ack Room temperature: 19.42 | |
15:55:29.808829 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:30.189686 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:30.685256 T10015A00 Write-Data Control setpoint: 90.00 | |
15:55:30.776311 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:55:31.852152 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:31.889436 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:32.702139 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:32.803638 B40192C97 Read-Ack Boiler water temperature: 44.59 | |
15:55:33.705875 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:55:33.727247 R80790000 Read-Data CH pump operation hours: 0 | |
15:55:33.800874 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:55:33.820876 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:55:34.740496 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:34.894220 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:35.724007 T10015A00 Write-Data Control setpoint: 90.00 | |
15:55:35.879702 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:55:36.729965 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:36.873886 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:37.739413 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:37.881614 BC0192C66 Read-Ack Boiler water temperature: 44.40 | |
15:55:38.747324 T00630000 Read-Data Message ID 99: 0 | |
15:55:38.768051 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:55:38.855833 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:55:38.873928 AF0630000 Unk-DataId Message ID 99: 0 | |
15:55:39.756513 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:39.973073 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:40.762838 T10015A00 Write-Data Control setpoint: 90.00 | |
15:55:40.855534 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:55:41.774637 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:41.876305 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:42.809627 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:42.860452 B40192C4C Read-Ack Boiler water temperature: 44.30 | |
15:55:43.819928 T90395A00 Write-Data Max CH water setpoint: 90.00 | |
15:55:43.958195 B60394B00 Data-Inv Max CH water setpoint: 75.00 | |
15:55:44.834669 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:45.170809 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:45.811410 T10015A00 Write-Data Control setpoint: 90.00 | |
15:55:45.959477 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:55:46.819579 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:46.959086 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:48.241628 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:48.271119 BC0192C33 Read-Ack Boiler water temperature: 44.20 | |
15:55:49.058661 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:55:49.081014 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:55:49.884316 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:50.229388 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:51.135134 T10015A00 Write-Data Control setpoint: 90.00 | |
15:55:51.157270 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:55:51.954423 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:51.978656 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:52.875327 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:52.969291 BC0192C00 Read-Ack Boiler water temperature: 44.00 | |
15:55:53.888641 T001B0000 Read-Data Outside temperature: 0.00 | |
15:55:53.899769 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:55:53.977228 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:55:53.984542 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:55:55.216082 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:55:55.323818 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:55:56.019082 T10015A00 Write-Data Control setpoint: 90.00 | |
15:55:56.064075 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:55:56.923277 T00110000 Read-Data Relative modulation level: 0.00 | |
15:55:57.081693 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:55:57.934056 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:55:58.060895 BC0192BE6 Read-Ack Boiler water temperature: 43.90 | |
15:55:58.930103 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:55:59.060505 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:56:00.001172 Command: SC=15:56/6 | |
15:56:00.058126 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:00.259357 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:01.058568 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:01.068812 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:01.956940 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:02.061263 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:02.972189 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:03.062631 B40192BCC Read-Ack Boiler water temperature: 43.80 | |
15:56:03.977661 T10101580 Write-Data Room setpoint: 21.50 | |
15:56:04.628025 BD0101580 Write-Ack Room setpoint: 21.50 | |
15:56:05.007987 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:05.090151 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:05.992193 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:06.085526 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:07.002922 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:07.150540 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:08.314799 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:08.321167 BC0192BE6 Read-Ack Boiler water temperature: 43.90 | |
15:56:09.126982 T90181370 Write-Data Room temperature: 19.44 | |
15:56:09.140370 B50181370 Write-Ack Room temperature: 19.44 | |
15:56:10.357755 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:10.477763 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:11.031911 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:11.143046 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:12.045083 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:12.142186 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:13.048636 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:13.141519 B40192C19 Read-Ack Boiler water temperature: 44.10 | |
15:56:14.061967 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:56:14.085608 R00740000 Read-Data Burner starts: 0 | |
15:56:14.152297 BC074FFFF Read-Ack Burner starts: 65535 | |
15:56:14.178704 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:56:15.148614 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:15.245130 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:16.097534 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:16.142524 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:17.083694 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:17.246808 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:18.168854 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:18.222181 B40192C4C Read-Ack Boiler water temperature: 44.30 | |
15:56:19.375522 T00630000 Read-Data Message ID 99: 0 | |
15:56:19.406280 R80750000 Read-Data CH pump starts: 0 | |
15:56:19.449302 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:56:19.494748 AF0630000 Unk-DataId Message ID 99: 0 | |
15:56:20.185809 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:20.375662 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:21.420939 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:21.427578 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:22.163637 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:22.252955 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:23.463864 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:23.487974 BC0192C78 Read-Ack Boiler water temperature: 44.47 | |
15:56:24.281593 T80640000 Read-Data Remote override function: 00000000 | |
15:56:24.289862 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:56:24.303256 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:56:24.317605 A40640101 Read-Ack Remote override function: 00000001 | |
- Manual change priority: enable overrule (1) | |
- Program change priority: disable overrule (0) | |
15:56:25.154960 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:25.420688 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:26.334005 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:26.349538 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:27.560873 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:27.586817 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:28.378096 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:28.393825 BC0192C99 Read-Ack Boiler water temperature: 44.60 | |
15:56:29.606432 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:56:29.625877 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:56:30.208576 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:30.353722 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:31.231637 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:31.343857 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:32.231581 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:32.343879 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:33.293502 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:33.343270 BC0192CCC Read-Ack Boiler water temperature: 44.80 | |
15:56:34.527588 T001B0000 Read-Data Outside temperature: 0.00 | |
15:56:34.565608 R00770000 Read-Data DHW burner starts: 0 | |
15:56:34.599704 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:56:34.621326 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:56:35.323956 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:35.627167 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:36.426731 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:36.445246 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:37.325637 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:37.369459 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:38.535872 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:38.556004 B40192D00 Read-Ack Boiler water temperature: 45.00 | |
15:56:39.441593 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:56:39.463988 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:56:40.667218 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:40.972215 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:41.300064 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:41.426603 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:42.715558 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:42.733696 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:43.318054 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:43.426736 BC0192D19 Read-Ack Boiler water temperature: 45.10 | |
15:56:44.762926 T10101580 Write-Data Room setpoint: 21.50 | |
15:56:44.782373 BD0101580 Write-Ack Room setpoint: 21.50 | |
15:56:45.584568 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:45.709670 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:46.386581 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:46.433105 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:47.629545 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:47.647005 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:48.368032 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:48.527714 B40192D33 Read-Ack Boiler water temperature: 45.20 | |
15:56:49.378322 T10181378 Write-Data Room temperature: 19.47 | |
15:56:49.528032 BD0181378 Write-Ack Room temperature: 19.47 | |
15:56:50.496733 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:50.619538 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:51.726044 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:51.745129 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:52.545583 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:52.563354 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:53.383371 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:53.529021 BC0192D4C Read-Ack Boiler water temperature: 45.30 | |
15:56:54.594474 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:56:54.613044 R00780000 Read-Data Burner operation hours: 0 | |
15:56:54.641292 B4078153C Read-Ack Burner operation hours: 5436 | |
15:56:54.661632 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:56:55.411928 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:56:55.536235 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:56:56.667853 T10015A00 Write-Data Control setpoint: 90.00 | |
15:56:56.687515 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:56:57.461063 T00110000 Read-Data Relative modulation level: 0.00 | |
15:56:57.505351 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:56:58.377104 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:56:58.530803 B40192D66 Read-Ack Boiler water temperature: 45.40 | |
15:56:59.510466 T00630000 Read-Data Message ID 99: 0 | |
15:56:59.531739 R80790000 Read-Data CH pump operation hours: 0 | |
15:56:59.559907 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:56:59.578169 AF0630000 Unk-DataId Message ID 99: 0 | |
15:57:00.006708 Command: SC=15:57/6 | |
15:57:00.071465 SC: 15:57/6 | |
15:57:00.376074 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:00.527248 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:01.439879 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:01.538200 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:02.405659 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:02.527789 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:03.377331 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:03.531812 BC0192D75 Read-Ack Boiler water temperature: 45.46 | |
15:57:04.424144 T00740000 Read-Data Burner starts: 0 | |
15:57:04.529203 BC074FFFF Read-Ack Burner starts: 65535 | |
15:57:05.381411 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:05.530755 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:06.470940 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:06.516604 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:07.700953 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:07.719466 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:08.523623 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:08.553504 BC0192D80 Read-Ack Boiler water temperature: 45.50 | |
15:57:09.375902 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:57:09.529551 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:57:10.376826 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:10.729329 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:11.387322 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:11.531886 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:12.398658 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:12.532036 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:13.377765 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:13.527240 B40192D99 Read-Ack Boiler water temperature: 45.60 | |
15:57:14.664140 T001B0000 Read-Data Outside temperature: 0.00 | |
15:57:14.684056 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:57:14.716315 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:57:14.750970 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:57:15.378393 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:15.680416 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:16.712475 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:16.737704 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:17.377235 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:17.531871 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:18.603445 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:18.612034 BC0192DB0 Read-Ack Boiler water temperature: 45.69 | |
15:57:19.579457 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:57:19.615691 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:57:20.374706 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:20.625051 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:21.377055 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:21.510211 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:22.466574 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:22.510449 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:23.606720 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:23.627498 BC0192DB3 Read-Ack Boiler water temperature: 45.70 | |
15:57:24.372474 T10101580 Write-Data Room setpoint: 21.50 | |
15:57:24.511835 BD0101580 Write-Ack Room setpoint: 21.50 | |
15:57:25.378648 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:25.628601 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:26.543236 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:26.561006 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:27.394574 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:27.509583 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:28.591288 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:28.610907 BC0192DB3 Read-Ack Boiler water temperature: 45.70 | |
15:57:29.820321 T10181378 Write-Data Room temperature: 19.47 | |
15:57:29.842952 BD0181378 Write-Ack Room temperature: 19.47 | |
15:57:30.640454 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:30.827073 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:31.426528 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:31.519641 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:32.432526 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:32.526504 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:33.442004 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:33.536196 BC0192DE6 Read-Ack Boiler water temperature: 45.90 | |
15:57:34.448429 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:57:34.477702 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:57:34.612730 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:57:34.647870 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:57:35.583388 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:35.799704 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:36.783397 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:36.803086 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:37.472637 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:37.611369 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:38.479817 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:38.614357 BC0192DE6 Read-Ack Boiler water temperature: 45.90 | |
15:57:39.652660 T00630000 Read-Data Message ID 99: 0 | |
15:57:39.672278 R00740000 Read-Data Burner starts: 0 | |
15:57:39.705695 BC074FFFF Read-Ack Burner starts: 65535 | |
15:57:39.753915 AF0630000 Unk-DataId Message ID 99: 0 | |
15:57:40.880687 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:41.096611 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:41.699310 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:41.717637 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:42.927695 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:42.937208 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:43.647968 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:43.674482 B40192E00 Read-Ack Boiler water temperature: 46.00 | |
15:57:44.539566 T00770000 Read-Data DHW burner starts: 0 | |
15:57:44.594099 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:57:45.633531 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:45.797991 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:46.614195 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:46.755445 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:47.618003 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:47.724900 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:48.654059 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:48.706888 B40192E00 Read-Ack Boiler water temperature: 46.00 | |
15:57:49.573647 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:57:49.704256 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:57:50.577507 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:50.725405 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:51.589131 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:51.702038 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:52.597767 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:52.702031 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:53.667086 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:53.715966 BC0192E19 Read-Ack Boiler water temperature: 46.10 | |
15:57:54.619831 T001B0000 Read-Data Outside temperature: 0.00 | |
15:57:54.637183 R80750000 Read-Data CH pump starts: 0 | |
15:57:54.717727 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:57:54.739382 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:57:55.617002 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:57:55.996416 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:57:56.619160 T10015A00 Write-Data Control setpoint: 90.00 | |
15:57:56.713195 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:57:57.622897 T00110000 Read-Data Relative modulation level: 0.00 | |
15:57:57.721358 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:57:58.626846 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:57:58.727297 BC0192E19 Read-Ack Boiler water temperature: 46.10 | |
15:57:59.624721 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:57:59.721311 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:58:00.015500 Command: SC=15:58/6 | |
15:58:00.079127 SC: 15:58/6 | |
15:58:00.631255 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:00.869660 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:01.633117 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:01.726484 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:02.626393 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:02.722423 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:03.630433 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:03.731208 B40192E33 Read-Ack Boiler water temperature: 46.20 | |
15:58:04.941063 T10101580 Write-Data Room setpoint: 21.50 | |
15:58:04.966446 BD0101580 Write-Ack Room setpoint: 21.50 | |
15:58:05.629127 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:05.841669 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:06.684180 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:06.784653 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:07.914379 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:07.949890 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:08.694061 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:08.785853 B40192E33 Read-Ack Boiler water temperature: 46.20 | |
15:58:09.965364 T9018137A Write-Data Room temperature: 19.48 | |
15:58:10.000298 B5018137A Write-Ack Room temperature: 19.48 | |
15:58:10.780679 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:10.993590 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:11.999541 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:12.006746 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:12.827855 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:12.851885 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:13.649069 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:13.789551 BC0192E4C Read-Ack Boiler water temperature: 46.30 | |
15:58:14.631204 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:58:14.657248 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:58:14.790379 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:58:14.819654 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:58:15.700317 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:16.101827 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:16.626075 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:16.789640 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:17.743814 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:17.816154 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:18.699159 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:18.796775 BC0192E4F Read-Ack Boiler water temperature: 46.31 | |
15:58:19.627054 T00630000 Read-Data Message ID 99: 0 | |
15:58:19.635141 R00770000 Read-Data DHW burner starts: 0 | |
15:58:19.793311 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:58:19.830899 AF0630000 Unk-DataId Message ID 99: 0 | |
15:58:21.020356 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:21.192378 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:21.841236 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:21.865514 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:23.068878 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:23.093768 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:23.702325 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:23.791872 B40192E66 Read-Ack Boiler water temperature: 46.40 | |
15:58:24.710650 T00780000 Read-Data Burner operation hours: 0 | |
15:58:24.799863 BC078153E Read-Ack Burner operation hours: 5438 | |
15:58:25.935436 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:26.249878 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:26.784159 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:26.816003 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:27.696140 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:27.783941 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:28.710105 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:28.805751 B40192E66 Read-Ack Boiler water temperature: 46.40 | |
15:58:30.031430 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:58:30.062644 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:58:30.851113 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:31.120096 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:32.081554 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:32.107671 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:32.735530 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:32.875281 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:33.746980 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:33.881853 BC0192E80 Read-Ack Boiler water temperature: 46.50 | |
15:58:34.846920 T001B0000 Read-Data Outside temperature: 0.00 | |
15:58:34.861165 R00780000 Read-Data Burner operation hours: 0 | |
15:58:34.876639 BC078153E Read-Ack Burner operation hours: 5438 | |
15:58:34.895592 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:58:36.176759 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:36.468425 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:36.996635 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:37.013402 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:37.815868 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:37.863567 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:38.785101 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:38.878220 BC0192EB3 Read-Ack Boiler water temperature: 46.70 | |
15:58:39.891106 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:58:39.928316 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:58:40.802048 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:41.174086 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:41.827665 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:41.871709 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:43.143057 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:43.167935 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:43.826065 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:43.990229 B40192ECC Read-Ack Boiler water temperature: 46.80 | |
15:58:44.968450 T10101580 Write-Data Room setpoint: 21.50 | |
15:58:44.995605 BD0101580 Write-Ack Room setpoint: 21.50 | |
15:58:46.007261 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:46.208930 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:46.845280 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:46.978966 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:48.105092 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:48.129624 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:48.863668 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:48.982484 B40192ECC Read-Ack Boiler water temperature: 46.80 | |
15:58:50.102672 T10181387 Write-Data Room temperature: 19.53 | |
15:58:50.133754 BD0181387 Write-Ack Room temperature: 19.53 | |
15:58:50.880207 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:51.207708 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:51.886888 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:51.981214 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:52.895206 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:52.954289 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:53.899784 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:54.072435 BC0192EE6 Read-Ack Boiler water temperature: 46.90 | |
15:58:55.021434 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:58:55.045914 R80790000 Read-Data CH pump operation hours: 0 | |
15:58:55.087828 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
15:58:55.129134 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:58:56.248693 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:58:56.596293 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:58:57.065617 T10015A00 Write-Data Control setpoint: 90.00 | |
15:58:57.090262 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:58:58.297154 T00110000 Read-Data Relative modulation level: 0.00 | |
15:58:58.325303 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:58:58.943373 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:58:59.064752 BC0192EE6 Read-Ack Boiler water temperature: 46.90 | |
15:59:00.003788 Command: SC=15:59/6 | |
15:59:00.069297 T00630000 Read-Data Message ID 99: 0 | |
15:59:00.094854 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
15:59:00.116564 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
15:59:00.137290 AF0630000 Unk-DataId Message ID 99: 0 | |
15:59:00.956890 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:01.137736 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:01.967512 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:02.062921 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:03.208835 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:03.216066 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:03.989319 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:04.075466 BC0192F00 Read-Ack Boiler water temperature: 47.00 | |
15:59:04.990835 T007B0000 Read-Data DHW burner operation hours: 0 | |
15:59:05.082362 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:59:05.999573 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:06.098257 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:07.002914 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:07.165991 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:08.126037 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:08.173257 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:09.018873 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:09.167002 B40192F02 Read-Ack Boiler water temperature: 47.01 | |
15:59:10.072770 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:59:10.167182 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:59:11.036227 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:11.350402 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:12.046379 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:12.167451 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:13.131578 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:13.174696 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:14.274705 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:14.291984 B40192F19 Read-Ack Boiler water temperature: 47.10 | |
15:59:15.088459 T001B0000 Read-Data Outside temperature: 0.00 | |
15:59:15.112044 R007B0000 Read-Data DHW burner operation hours: 0 | |
15:59:15.182307 B407B0296 Read-Ack DHW burner operation hours: 662 | |
15:59:15.197177 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:59:16.316943 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:16.699731 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:17.166140 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:17.189766 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:18.367614 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:18.394906 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:19.184091 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:19.230839 BC0192F33 Read-Ack Boiler water temperature: 47.20 | |
15:59:20.102175 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
15:59:20.301470 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
15:59:21.232682 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:21.543574 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:22.461545 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:22.483572 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:23.286822 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:23.308774 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:24.509995 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:24.535119 BC0192F35 Read-Ack Boiler water temperature: 47.21 | |
15:59:25.329021 T10101580 Write-Data Room setpoint: 21.50 | |
15:59:25.357649 BD0101580 Write-Ack Room setpoint: 21.50 | |
15:59:26.559864 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:26.895164 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:27.792634 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:27.847227 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:28.197863 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:28.241824 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:29.424131 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:29.447446 B40192F4C Read-Ack Boiler water temperature: 47.30 | |
15:59:30.190170 T10181387 Write-Data Room temperature: 19.53 | |
15:59:30.351688 BD0181387 Write-Ack Room temperature: 19.53 | |
15:59:31.472526 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:31.751904 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:32.302738 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:32.348413 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:33.215143 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:33.350130 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:34.342356 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:34.367822 B40192F80 Read-Ack Boiler water temperature: 47.50 | |
15:59:35.570222 T00090000 Read-Data Remote override room setpoint: 0.00 | |
15:59:35.580726 R00740000 Read-Data Burner starts: 0 | |
15:59:35.599980 BC074FFFF Read-Ack Burner starts: 65535 | |
15:59:35.618419 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
15:59:36.241232 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:36.408973 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:37.329877 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:37.358508 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:38.442346 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:38.468978 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:39.680016 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:39.707093 B40192F80 Read-Ack Boiler water temperature: 47.50 | |
15:59:40.486199 T00630000 Read-Data Message ID 99: 0 | |
15:59:40.513177 R80750000 Read-Data CH pump starts: 0 | |
15:59:40.553810 B4075FFFF Read-Ack CH pump starts: 65535 | |
15:59:40.598919 AF0630000 Unk-DataId Message ID 99: 0 | |
15:59:41.303246 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:41.628945 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:42.532528 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:42.560504 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:43.351375 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:43.459020 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:44.302295 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:44.448654 BC0192F99 Read-Ack Boiler water temperature: 47.60 | |
15:59:45.322671 T806D0000 Read-Data Message ID 109: 0 | |
15:59:45.344827 R80760000 Read-Data DHW pump/valve starts: 0 | |
15:59:45.469506 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
15:59:45.494752 A706D0000 Unk-DataId Message ID 109: 0 | |
15:59:46.317022 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:46.807342 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:47.329748 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:47.448975 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:48.679975 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:48.701334 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:49.495808 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:49.517927 B40192FB3 Read-Ack Boiler water temperature: 47.70 | |
15:59:50.724144 T00050000 Read-Data Application-specific flags: 00000000 0 | |
15:59:50.751408 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
15:59:51.549064 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:51.840028 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:52.772165 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:52.804015 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:53.590887 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:53.616137 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:54.410757 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:54.547885 B40192FB5 Read-Ack Boiler water temperature: 47.71 | |
15:59:55.657409 T001B0000 Read-Data Outside temperature: 0.00 | |
15:59:55.682998 R00770000 Read-Data DHW burner starts: 0 | |
15:59:55.726527 BC077DA98 Read-Ack DHW burner starts: 55960 | |
15:59:55.762107 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
15:59:56.461178 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
15:59:56.828165 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
15:59:57.694113 T10015A00 Write-Data Control setpoint: 90.00 | |
15:59:57.720181 BD0015A00 Write-Ack Control setpoint: 90.00 | |
15:59:58.537380 T00110000 Read-Data Relative modulation level: 0.00 | |
15:59:58.582790 BC0110000 Read-Ack Relative modulation level: 0.00 | |
15:59:59.735406 T80190000 Read-Data Boiler water temperature: 0.00 | |
15:59:59.769768 BC0192FCC Read-Ack Boiler water temperature: 47.80 | |
16:00:00.000670 Command: SC=16:00/6 | |
16:00:00.094382 SC: 16:00/6 | |
16:00:00.553610 T100E0000 Write-Data Maximum relative modulation level: 0.00 | |
16:00:00.562909 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 | |
16:00:01.505750 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:01.827744 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:02.602970 T10015A00 Write-Data Control setpoint: 90.00 | |
16:00:02.628304 BD0015A00 Write-Ack Control setpoint: 90.00 | |
16:00:03.585280 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:03.613415 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:00:04.471142 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:04.564456 BC0192FCC Read-Ack Boiler water temperature: 47.80 | |
16:00:05.632867 T10101580 Write-Data Room setpoint: 21.50 | |
16:00:05.660729 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:00:06.481565 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:06.884108 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:07.487914 T10015A00 Write-Data Control setpoint: 90.00 | |
16:00:07.649053 BD0015A00 Write-Ack Control setpoint: 90.00 | |
16:00:08.747005 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:08.785201 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:00:09.575468 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:09.622275 B40192FE6 Read-Ack Boiler water temperature: 47.90 | |
16:00:10.824979 T9018138F Write-Data Room temperature: 19.56 | |
16:00:10.834164 B5018138F Write-Ack Room temperature: 19.56 | |
16:00:11.519776 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:11.833989 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:12.528510 T10015A00 Write-Data Control setpoint: 90.00 | |
16:00:12.623299 BD0015A00 Write-Ack Control setpoint: 90.00 | |
16:00:13.662281 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:13.687713 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:00:14.544372 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:14.637619 B40193000 Read-Ack Boiler water temperature: 48.00 | |
16:00:15.714280 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:00:15.739922 R00780000 Read-Data Burner operation hours: 0 | |
16:00:15.785600 BC078153E Read-Ack Burner operation hours: 5438 | |
16:00:15.836087 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:00:16.561010 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:16.730664 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:17.572957 T10015A00 Write-Data Control setpoint: 90.00 | |
16:00:17.739652 BD0015A00 Write-Ack Control setpoint: 90.00 | |
16:00:18.582254 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:18.722695 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:00:19.589792 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:19.721917 BC0193019 Read-Ack Boiler water temperature: 48.10 | |
16:00:20.625206 T00630000 Read-Data Message ID 99: 0 | |
16:00:20.655427 R80790000 Read-Data CH pump operation hours: 0 | |
16:00:20.729354 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:00:20.758493 AF0630000 Unk-DataId Message ID 99: 0 | |
16:00:21.854466 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:22.098406 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:22.673568 T10015A00 Write-Data Control setpoint: 90.00 | |
16:00:22.720087 BD0015A00 Write-Ack Control setpoint: 90.00 | |
16:00:23.838003 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:23.883601 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:00:24.750536 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:24.772208 BC0193026 Read-Ack Boiler water temperature: 48.15 | |
16:00:25.632260 T806E0000 Read-Data Message ID 110: 0 | |
16:00:25.655994 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:00:25.728724 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:00:25.755837 A706E0000 Unk-DataId Message ID 110: 0 | |
16:00:26.770285 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:27.168071 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:27.651869 T10015A00 Write-Data Control setpoint: 90.00 | |
16:00:27.739265 BD0015A00 Write-Ack Control setpoint: 90.00 | |
16:00:28.652381 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:28.751396 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:00:30.047076 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:30.068577 BC0193038 Read-Ack Boiler water temperature: 48.22 | |
16:00:30.867068 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:00:30.905668 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:00:31.678312 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:31.983184 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:32.685759 T10015A00 Write-Data Control setpoint: 90.00 | |
16:00:32.827153 BD0015A00 Write-Ack Control setpoint: 90.00 | |
16:00:33.694386 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:33.823253 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:00:34.700382 T10013900 Write-Data Control setpoint: 57.00 | |
16:00:34.830519 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:00:35.797639 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:00:35.834431 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:00:37.038962 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:37.071488 B40193066 Read-Ack Boiler water temperature: 48.40 | |
16:00:37.855160 T001B0000 Read-Data Outside temperature: 0.00 | |
16:00:37.884887 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:00:37.936397 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:00:37.991870 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:00:38.735446 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:38.835081 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:39.878008 T10013900 Write-Data Control setpoint: 57.00 | |
16:00:39.917785 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:00:40.754103 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:40.843282 B40110100 Read-Ack Relative modulation level: 1.00 | |
16:00:41.764067 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:41.923304 BC0193080 Read-Ack Boiler water temperature: 48.50 | |
16:00:43.156315 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:00:43.181942 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:00:43.859034 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:44.207127 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:45.202656 T10013900 Write-Data Control setpoint: 57.00 | |
16:00:45.236761 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:00:46.039103 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:46.069233 BC0110300 Read-Ack Relative modulation level: 3.00 | |
16:00:46.823215 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:46.918269 BC01930B3 Read-Ack Boiler water temperature: 48.70 | |
16:00:47.811811 T10101580 Write-Data Room setpoint: 21.50 | |
16:00:47.924174 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:00:48.823012 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:48.945027 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:49.828168 T10013900 Write-Data Control setpoint: 57.00 | |
16:00:49.896977 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:00:50.833557 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:50.927155 BC0110500 Read-Ack Relative modulation level: 5.00 | |
16:00:51.851254 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:51.944770 BC01930FD Read-Ack Boiler water temperature: 48.99 | |
16:00:52.873131 T90181394 Write-Data Room temperature: 19.58 | |
16:00:53.017132 B50181394 Write-Ack Room temperature: 19.58 | |
16:00:53.861922 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:54.026279 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:54.869454 T10013900 Write-Data Control setpoint: 57.00 | |
16:00:55.016666 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:00:55.881191 T00110000 Read-Data Relative modulation level: 0.00 | |
16:00:56.018509 B40110700 Read-Ack Relative modulation level: 7.00 | |
16:00:56.890844 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:00:57.014220 BC0193166 Read-Ack Boiler water temperature: 49.40 | |
16:00:57.893821 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:00:57.902386 R00740000 Read-Data Burner starts: 0 | |
16:00:58.016280 BC074FFFF Read-Ack Burner starts: 65535 | |
16:00:58.025466 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:00:58.915686 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:00:59.031720 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:00:59.956437 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:00.000593 Command: SC=16:01/6 | |
16:01:00.014273 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:00.916025 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:01.014587 B40110800 Read-Ack Relative modulation level: 8.00 | |
16:01:02.000414 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:02.011829 B401931B3 Read-Ack Boiler water temperature: 49.70 | |
16:01:02.935792 T00630000 Read-Data Message ID 99: 0 | |
16:01:02.968246 R80750000 Read-Data CH pump starts: 0 | |
16:01:03.030468 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:01:03.046510 AF0630000 Unk-DataId Message ID 99: 0 | |
16:01:03.950250 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:04.194730 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:05.098949 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:05.108034 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:05.957774 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:06.119320 BC0110A00 Read-Ack Relative modulation level: 10.00 | |
16:01:06.969293 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:07.109114 B40193219 Read-Ack Boiler water temperature: 50.10 | |
16:01:07.982200 T006F0000 Read-Data Message ID 111: 0 | |
16:01:08.015641 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:01:08.115049 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:01:08.155661 AF06F0000 Unk-DataId Message ID 111: 0 | |
16:01:08.988867 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:09.277069 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:10.186836 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:10.216085 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:11.137264 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:11.157841 B40110B00 Read-Ack Relative modulation level: 11.00 | |
16:01:12.011151 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:12.104495 BC0193266 Read-Ack Boiler water temperature: 50.40 | |
16:01:13.031184 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:01:13.124566 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:01:14.024153 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:14.234866 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:15.033155 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:15.130413 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:16.041594 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:16.203549 BC0110C00 Read-Ack Relative modulation level: 12.00 | |
16:01:17.135554 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:17.179289 B401932B3 Read-Ack Boiler water temperature: 50.70 | |
16:01:18.379630 T001B0000 Read-Data Outside temperature: 0.00 | |
16:01:18.402180 R00770000 Read-Data DHW burner starts: 0 | |
16:01:18.448505 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:01:18.479277 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:01:19.066841 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:19.355199 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:20.206744 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:20.236444 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:21.250209 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:21.269923 B40110E00 Read-Ack Relative modulation level: 14.00 | |
16:01:22.195307 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:22.221714 BC0193302 Read-Ack Boiler water temperature: 51.01 | |
16:01:23.246192 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:01:23.268732 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:01:24.107278 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:24.391366 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:25.342888 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:25.366444 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:26.162210 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:26.207355 BC0110F00 Read-Ack Relative modulation level: 15.00 | |
16:01:27.391940 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:27.419166 B40193342 Read-Ack Boiler water temperature: 51.26 | |
16:01:28.211475 T10101580 Write-Data Room setpoint: 21.50 | |
16:01:28.301293 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:01:29.149585 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:29.504989 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:30.258337 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:30.302926 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:31.857258 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:31.883728 B40111000 Read-Ack Relative modulation level: 16.00 | |
16:01:32.307213 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:32.347640 BC0193380 Read-Ack Boiler water temperature: 51.50 | |
16:01:33.537755 T90181394 Write-Data Room temperature: 19.58 | |
16:01:33.580740 B50181394 Write-Ack Room temperature: 19.58 | |
16:01:34.355343 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:34.713950 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:35.202065 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:35.293847 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:36.203708 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:36.297035 BC0111100 Read-Ack Relative modulation level: 17.00 | |
16:01:37.215651 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:37.309136 B401933CC Read-Ack Boiler water temperature: 51.80 | |
16:01:38.285210 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:01:38.326020 R00780000 Read-Data Burner operation hours: 0 | |
16:01:38.403814 BC078153E Read-Ack Burner operation hours: 5438 | |
16:01:38.435544 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:01:39.269326 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:39.571075 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:40.237649 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:40.395876 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:41.248453 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:41.386719 BC0111200 Read-Ack Relative modulation level: 18.00 | |
16:01:42.257909 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:42.387201 B40193402 Read-Ack Boiler water temperature: 52.01 | |
16:01:43.368342 T00630000 Read-Data Message ID 99: 0 | |
16:01:43.396082 R80790000 Read-Data CH pump operation hours: 0 | |
16:01:43.441235 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:01:43.496883 AF0630000 Unk-DataId Message ID 99: 0 | |
16:01:44.272300 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:44.611370 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:45.279636 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:45.382903 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:46.291786 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:46.383752 B40111300 Read-Ack Relative modulation level: 19.00 | |
16:01:47.476172 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:47.506927 BC0193433 Read-Ack Boiler water temperature: 52.20 | |
16:01:48.690107 T80700000 Read-Data Message ID 112: 0 | |
16:01:48.698588 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:01:48.711800 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:01:48.727185 A70700000 Unk-DataId Message ID 112: 0 | |
16:01:49.403275 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:49.506675 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:50.321409 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:50.481196 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:51.328964 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:51.484517 BC0111400 Read-Ack Relative modulation level: 20.00 | |
16:01:52.335563 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:52.480326 B40193480 Read-Ack Boiler water temperature: 52.50 | |
16:01:53.582788 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:01:53.620303 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:01:54.734090 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:01:54.896857 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:01:56.053175 T10013900 Write-Data Control setpoint: 57.00 | |
16:01:56.081694 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:01:56.367778 T00110000 Read-Data Relative modulation level: 0.00 | |
16:01:56.481361 B40111500 Read-Ack Relative modulation level: 21.00 | |
16:01:57.703134 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:01:57.731346 B401934B5 Read-Ack Boiler water temperature: 52.71 | |
16:01:58.388892 T001B0000 Read-Data Outside temperature: 0.00 | |
16:01:58.416898 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:01:58.479833 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:01:58.501457 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:01:59.754660 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:00.135657 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:00.468368 Command: SC=16:02/6 | |
16:02:00.484248 T10013900 Write-Data Control setpoint: 57.00 | |
16:02:00.498405 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:02:01.413137 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:01.577515 B40111600 Read-Ack Relative modulation level: 22.00 | |
16:02:02.617554 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:02.641805 B401934E6 Read-Ack Boiler water temperature: 52.90 | |
16:02:03.425650 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:02:03.571741 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:02:04.433709 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:04.609698 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:05.442061 T10013900 Write-Data Control setpoint: 57.00 | |
16:02:05.571996 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:02:06.451520 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:06.571208 BC0111700 Read-Ack Relative modulation level: 23.00 | |
16:02:07.459537 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:07.569911 BC0193519 Read-Ack Boiler water temperature: 53.10 | |
16:02:08.468324 T10101580 Write-Data Room setpoint: 21.50 | |
16:02:08.575266 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:02:09.580525 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:09.762233 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:10.481656 T10013900 Write-Data Control setpoint: 57.00 | |
16:02:10.573817 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:02:11.629592 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:11.666479 BC0111800 Read-Ack Relative modulation level: 24.00 | |
16:02:12.500709 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:12.591845 BC019353D Read-Ack Boiler water temperature: 53.24 | |
16:02:13.507797 T1018139C Write-Data Room temperature: 19.61 | |
16:02:13.675328 BD018139C Write-Ack Room temperature: 19.61 | |
16:02:14.527249 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:14.902299 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:15.522276 T10013900 Write-Data Control setpoint: 57.00 | |
16:02:15.663826 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:02:16.532256 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:16.663417 BC0111800 Read-Ack Relative modulation level: 24.00 | |
16:02:17.548909 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:17.662111 BC0193570 Read-Ack Boiler water temperature: 53.44 | |
16:02:18.592995 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:02:18.620722 R00740000 Read-Data Burner starts: 0 | |
16:02:18.671482 BC074FFFF Read-Ack Burner starts: 65535 | |
16:02:18.719088 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:02:19.555813 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:19.788257 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:20.640344 T10013900 Write-Data Control setpoint: 57.00 | |
16:02:20.673812 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:02:21.575754 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:21.666564 B40111900 Read-Ack Relative modulation level: 25.00 | |
16:02:22.582360 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:22.676232 B40193599 Read-Ack Boiler water temperature: 53.60 | |
16:02:23.594740 T00630000 Read-Data Message ID 99: 0 | |
16:02:23.623744 R80750000 Read-Data CH pump starts: 0 | |
16:02:23.702913 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:02:23.733279 AF0630000 Unk-DataId Message ID 99: 0 | |
16:02:24.736120 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:25.069855 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:25.611304 T10013900 Write-Data Control setpoint: 57.00 | |
16:02:25.760262 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:02:26.615519 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:26.757842 B40111A00 Read-Ack Relative modulation level: 26.00 | |
16:02:27.632096 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:27.757782 B401935CC Read-Ack Boiler water temperature: 53.80 | |
16:02:28.833568 T1002010B Write-Data Master configuration: 00000001 11 | |
- Smart power: supported (1) | |
16:02:28.914729 BD002010B Write-Ack Master configuration: 00000001 11 | |
- Smart power: supported (1) | |
16:02:29.657096 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:30.003055 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:30.882002 T10013900 Write-Data Control setpoint: 57.00 | |
16:02:30.909306 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:02:31.700177 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:31.758485 BC0111B00 Read-Ack Relative modulation level: 27.00 | |
16:02:32.929372 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:32.957283 B40193600 Read-Ack Boiler water temperature: 54.00 | |
16:02:33.672093 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:02:33.763525 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:02:34.677388 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:35.005864 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:35.796720 T90013919 Write-Data Control setpoint: 57.10 | |
16:02:35.822035 B50013919 Write-Ack Control setpoint: 57.10 | |
16:02:37.024519 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:37.047718 BC0111B00 Read-Ack Relative modulation level: 27.00 | |
16:02:37.828502 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:37.861648 B40193635 Read-Ack Boiler water temperature: 54.21 | |
16:02:38.977383 T001B0000 Read-Data Outside temperature: 0.00 | |
16:02:39.001517 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:02:39.041308 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:02:39.077561 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:02:39.718937 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:40.077929 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:41.121807 T90013919 Write-Data Control setpoint: 57.10 | |
16:02:41.142782 B50013919 Write-Ack Control setpoint: 57.10 | |
16:02:41.939449 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:41.966116 B40111C00 Read-Ack Relative modulation level: 28.00 | |
16:02:42.760140 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:42.863239 B40193666 Read-Ack Boiler water temperature: 54.40 | |
16:02:43.982088 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:02:44.014452 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:02:44.807609 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:45.136903 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:46.035931 T90013919 Write-Data Control setpoint: 57.10 | |
16:02:46.068855 B50013919 Write-Ack Control setpoint: 57.10 | |
16:02:46.883454 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:46.912739 B40111C00 Read-Ack Relative modulation level: 28.00 | |
16:02:47.780955 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:47.947390 BC0193680 Read-Ack Boiler water temperature: 54.50 | |
16:02:48.902998 T10101580 Write-Data Room setpoint: 21.50 | |
16:02:48.967220 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:02:50.147843 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:50.493892 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:50.877457 T90013919 Write-Data Control setpoint: 57.10 | |
16:02:50.951901 B50013919 Write-Ack Control setpoint: 57.10 | |
16:02:52.180626 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:52.211522 BC0111D00 Read-Ack Relative modulation level: 29.00 | |
16:02:52.999161 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:53.026915 BC01936B3 Read-Ack Boiler water temperature: 54.70 | |
16:02:53.999472 T101813A3 Write-Data Room temperature: 19.64 | |
16:02:54.032967 BD01813A3 Write-Ack Room temperature: 19.64 | |
16:02:55.049273 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:02:55.350193 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:02:55.845765 T90013919 Write-Data Control setpoint: 57.10 | |
16:02:55.940329 B50013919 Write-Ack Control setpoint: 57.10 | |
16:02:57.095244 T00110000 Read-Data Relative modulation level: 0.00 | |
16:02:57.126095 BC0111D00 Read-Ack Relative modulation level: 29.00 | |
16:02:57.914543 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:02:57.962997 B401936CC Read-Ack Boiler water temperature: 54.80 | |
16:02:59.007225 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:02:59.040626 R00770000 Read-Data DHW burner starts: 0 | |
16:02:59.091620 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:02:59.136447 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:02:59.989524 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:00.234944 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:00.516272 Command: SC=16:03/6 | |
16:03:00.651268 SC: 16:03/6 | |
16:03:00.887768 T90013919 Write-Data Control setpoint: 57.10 | |
16:03:00.980928 B50013919 Write-Ack Control setpoint: 57.10 | |
16:03:02.010784 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:02.060521 BC0111E00 Read-Ack Relative modulation level: 30.00 | |
16:03:03.242357 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:03.267465 BC0193700 Read-Ack Boiler water temperature: 55.00 | |
16:03:04.021261 T00630000 Read-Data Message ID 99: 0 | |
16:03:04.059690 R00780000 Read-Data Burner operation hours: 0 | |
16:03:04.112745 BC078153E Read-Ack Burner operation hours: 5438 | |
16:03:04.162353 AF0630000 Unk-DataId Message ID 99: 0 | |
16:03:04.923635 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:05.249226 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:05.934589 T90013919 Write-Data Control setpoint: 57.10 | |
16:03:06.056088 B50013919 Write-Ack Control setpoint: 57.10 | |
16:03:06.952754 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:07.054485 BC0111E00 Read-Ack Relative modulation level: 30.00 | |
16:03:08.158285 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:08.196392 BC0193733 Read-Ack Boiler water temperature: 55.20 | |
16:03:08.962077 T00030000 Read-Data Slave configuration: 00000000 0 | |
16:03:09.054774 B4003410B Read-Ack Slave configuration: 01000001 11 | |
- DHW: present (1) | |
- Control type: modulating (0) | |
- Cooling: not supported (0) | |
- DHW: instantaneous (0) | |
- Master pump control: allowed (0) | |
- CH2: not present (0) | |
- Remote water filling: not available (1) | |
- Heat/cool mode control: heat (0) | |
16:03:09.968852 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:10.258952 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:10.971672 T90013919 Write-Data Control setpoint: 57.10 | |
16:03:11.067678 B50013919 Write-Ack Control setpoint: 57.10 | |
16:03:11.982239 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:12.075263 BC0111E00 Read-Ack Relative modulation level: 30.00 | |
16:03:12.994181 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:13.160269 B4019374C Read-Ack Boiler water temperature: 55.30 | |
16:03:14.006474 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:03:14.153965 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:03:15.117583 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:15.399539 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:16.023965 T90013919 Write-Data Control setpoint: 57.10 | |
16:03:16.150751 B50013919 Write-Ack Control setpoint: 57.10 | |
16:03:17.034032 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:17.150941 B40111F00 Read-Ack Relative modulation level: 31.00 | |
16:03:18.043479 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:18.148812 BC0193766 Read-Ack Boiler water temperature: 55.40 | |
16:03:19.051411 T001B0000 Read-Data Outside temperature: 0.00 | |
16:03:19.077575 R80790000 Read-Data CH pump operation hours: 0 | |
16:03:19.148251 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:03:19.173768 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:03:20.239136 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:20.632018 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:21.063718 T90013919 Write-Data Control setpoint: 57.10 | |
16:03:21.151623 B50013919 Write-Ack Control setpoint: 57.10 | |
16:03:22.066148 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:22.156273 B40111F00 Read-Ack Relative modulation level: 31.00 | |
16:03:23.063765 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:23.155222 B40193785 Read-Ack Boiler water temperature: 55.52 | |
16:03:24.064426 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:03:24.231537 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:03:25.359126 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:25.715009 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:26.177739 T90013919 Write-Data Control setpoint: 57.10 | |
16:03:26.221939 B50013919 Write-Ack Control setpoint: 57.10 | |
16:03:27.066400 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:27.228981 B40111F00 Read-Ack Relative modulation level: 31.00 | |
16:03:28.067542 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:28.224812 B401937B3 Read-Ack Boiler water temperature: 55.70 | |
16:03:29.070958 T10101580 Write-Data Room setpoint: 21.50 | |
16:03:29.229124 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:03:30.275488 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:30.642907 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:31.087267 T90013919 Write-Data Control setpoint: 57.10 | |
16:03:31.224915 B50013919 Write-Ack Control setpoint: 57.10 | |
16:03:32.330049 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:32.362636 B40112000 Read-Ack Relative modulation level: 32.00 | |
16:03:33.140394 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:33.230299 B401937E6 Read-Ack Boiler water temperature: 55.90 | |
16:03:34.079593 T101813A3 Write-Data Room temperature: 19.64 | |
16:03:34.223083 BD01813A3 Write-Ack Room temperature: 19.64 | |
16:03:35.187716 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:35.470208 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:36.080675 T10013933 Write-Data Control setpoint: 57.20 | |
16:03:36.226410 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:03:37.239280 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:37.263404 B40112000 Read-Ack Relative modulation level: 32.00 | |
16:03:38.090810 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:38.228468 BC0193814 Read-Ack Boiler water temperature: 56.08 | |
16:03:39.081622 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:03:39.122996 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:03:39.223381 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:03:39.253396 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:03:40.130041 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:40.443134 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:41.177815 T10013933 Write-Data Control setpoint: 57.20 | |
16:03:41.224706 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:03:42.150223 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:42.201898 B40112000 Read-Ack Relative modulation level: 32.00 | |
16:03:43.382470 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:43.414646 BC0193833 Read-Ack Boiler water temperature: 56.20 | |
16:03:44.080166 T00630000 Read-Data Message ID 99: 0 | |
16:03:44.117280 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:03:44.239215 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:03:44.269576 AF0630000 Unk-DataId Message ID 99: 0 | |
16:03:45.079959 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:45.406855 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:46.097255 T10013933 Write-Data Control setpoint: 57.20 | |
16:03:46.218548 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:03:47.096543 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:47.217819 B40112000 Read-Ack Relative modulation level: 32.00 | |
16:03:48.142090 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:48.194408 B4019384C Read-Ack Boiler water temperature: 56.30 | |
16:03:49.115227 T00120000 Read-Data CH water pressure: 0.00 | |
16:03:49.150065 R00740000 Read-Data Burner starts: 0 | |
16:03:49.233313 BC074FFFF Read-Ack Burner starts: 65535 | |
16:03:49.262253 AF0120000 Unk-DataId CH water pressure: 0.00 | |
16:03:50.123781 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:50.375726 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:51.163637 T10013933 Write-Data Control setpoint: 57.20 | |
16:03:51.208158 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:03:52.136111 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:52.229114 BC0112100 Read-Ack Relative modulation level: 33.00 | |
16:03:53.145963 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:53.240003 BC0193866 Read-Ack Boiler water temperature: 56.40 | |
16:03:54.157526 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:03:54.317363 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:03:55.173405 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:03:55.448457 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:03:56.168032 T10013933 Write-Data Control setpoint: 57.20 | |
16:03:56.315963 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:03:57.176216 T00110000 Read-Data Relative modulation level: 0.00 | |
16:03:57.313004 BC0112100 Read-Ack Relative modulation level: 33.00 | |
16:03:58.197133 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:03:58.315812 B4019389E Read-Ack Boiler water temperature: 56.62 | |
16:03:59.194798 T001B0000 Read-Data Outside temperature: 0.00 | |
16:03:59.217313 R80750000 Read-Data CH pump starts: 0 | |
16:03:59.314108 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:03:59.340689 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:04:00.000981 Command: SC=16:04/6 | |
16:04:00.123067 SC: 16:04/6 | |
16:04:00.168009 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:00.412851 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:01.403566 T10013933 Write-Data Control setpoint: 57.20 | |
16:04:01.435543 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:04:02.634519 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:02.666652 BC0112100 Read-Ack Relative modulation level: 33.00 | |
16:04:03.457831 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:03.482097 BC01938CC Read-Ack Boiler water temperature: 56.80 | |
16:04:04.236016 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:04:04.334611 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:04:05.239834 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:05.548447 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:06.254374 T10013933 Write-Data Control setpoint: 57.20 | |
16:04:06.408971 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:04:07.272818 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:07.409846 BC0112100 Read-Ack Relative modulation level: 33.00 | |
16:04:08.370018 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:08.431302 B401938E6 Read-Ack Boiler water temperature: 56.90 | |
16:04:09.279355 T10101580 Write-Data Room setpoint: 21.50 | |
16:04:09.407384 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:04:10.432311 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:10.818878 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:11.666990 T10013933 Write-Data Control setpoint: 57.20 | |
16:04:11.700544 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:04:12.307038 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:12.407333 BC0112100 Read-Ack Relative modulation level: 33.00 | |
16:04:13.707710 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:13.742105 B40193900 Read-Ack Boiler water temperature: 57.00 | |
16:04:14.330544 T901813AB Write-Data Room temperature: 19.67 | |
16:04:14.425799 B501813AB Write-Ack Room temperature: 19.67 | |
16:04:15.330548 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:15.548904 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:16.414698 T10013933 Write-Data Control setpoint: 57.20 | |
16:04:16.447458 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:04:17.345569 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:17.509989 BC0112100 Read-Ack Relative modulation level: 33.00 | |
16:04:18.591588 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:18.627237 BC0193919 Read-Ack Boiler water temperature: 57.10 | |
16:04:19.361509 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:04:19.393415 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:04:19.504848 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:04:19.540935 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:04:20.373677 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:20.721993 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:21.377535 T10013933 Write-Data Control setpoint: 57.20 | |
16:04:21.504282 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:04:22.384691 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:22.504724 BC0112100 Read-Ack Relative modulation level: 33.00 | |
16:04:23.531276 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:23.569817 B40193933 Read-Ack Boiler water temperature: 57.20 | |
16:04:24.400999 T00630000 Read-Data Message ID 99: 0 | |
16:04:24.436244 R00770000 Read-Data DHW burner starts: 0 | |
16:04:24.512436 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:04:24.532425 AF0630000 Unk-DataId Message ID 99: 0 | |
16:04:25.524354 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:25.819668 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:26.417990 T10013933 Write-Data Control setpoint: 57.20 | |
16:04:26.509616 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:04:27.620183 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:27.647550 B40112000 Read-Ack Relative modulation level: 32.00 | |
16:04:28.436512 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:28.528718 BC019394C Read-Ack Boiler water temperature: 57.30 | |
16:04:29.446039 T801A0000 Read-Data DHW temperature: 0.00 | |
16:04:29.484289 R00780000 Read-Data Burner operation hours: 0 | |
16:04:29.604679 BC078153E Read-Ack Burner operation hours: 5438 | |
16:04:29.646928 A701A0000 Unk-DataId DHW temperature: 0.00 | |
16:04:30.489725 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:30.830463 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:31.457813 T9001394C Write-Data Control setpoint: 57.30 | |
16:04:31.601493 B5001394C Write-Ack Control setpoint: 57.30 | |
16:04:32.538880 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:32.591159 B40112000 Read-Ack Relative modulation level: 32.00 | |
16:04:33.481839 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:33.601756 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:04:34.481096 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:04:34.605052 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:04:35.487418 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:35.835518 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:36.512298 T9001394C Write-Data Control setpoint: 57.30 | |
16:04:36.600891 B5001394C Write-Ack Control setpoint: 57.30 | |
16:04:37.506324 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:37.611738 BC0111E00 Read-Ack Relative modulation level: 30.00 | |
16:04:38.510864 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:38.605017 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:04:39.776212 T001B0000 Read-Data Outside temperature: 0.00 | |
16:04:39.804140 R80790000 Read-Data CH pump operation hours: 0 | |
16:04:39.853616 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:04:39.896991 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:04:40.577482 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:40.966901 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:41.540236 T9001394C Write-Data Control setpoint: 57.30 | |
16:04:41.698936 B5001394C Write-Ack Control setpoint: 57.30 | |
16:04:42.539649 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:42.699904 BC0111D00 Read-Ack Relative modulation level: 29.00 | |
16:04:43.610795 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:43.667659 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:04:44.557356 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:04:44.697237 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:04:45.564315 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:45.936816 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:46.870171 T9001394C Write-Data Control setpoint: 57.30 | |
16:04:46.897827 B5001394C Write-Ack Control setpoint: 57.30 | |
16:04:47.688248 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:47.715285 B40111C00 Read-Ack Relative modulation level: 28.00 | |
16:04:48.584705 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:48.700610 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:04:49.736775 T10101580 Write-Data Room setpoint: 21.50 | |
16:04:49.769537 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:04:50.599298 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:50.876311 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:51.609269 T9001394C Write-Data Control setpoint: 57.30 | |
16:04:51.701401 B5001394C Write-Ack Control setpoint: 57.30 | |
16:04:52.617593 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:52.707121 BC0111B00 Read-Ack Relative modulation level: 27.00 | |
16:04:53.832837 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:53.863587 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:04:54.637526 T901813B0 Write-Data Room temperature: 19.69 | |
16:04:54.794892 B501813B0 Write-Ack Room temperature: 19.69 | |
16:04:55.882937 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:04:56.242550 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:04:56.675993 T9001394C Write-Data Control setpoint: 57.30 | |
16:04:56.799939 B5001394C Write-Ack Control setpoint: 57.30 | |
16:04:57.652396 T00110000 Read-Data Relative modulation level: 0.00 | |
16:04:57.792715 B40111A00 Read-Ack Relative modulation level: 26.00 | |
16:04:58.756238 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:04:58.804932 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:04:59.978165 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:05:00.016376 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:05:00.062793 Command: SC=16:05/6 | |
16:05:00.096402 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:05:00.135661 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:05:00.170768 SC: 16:05/6 | |
16:05:00.679101 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:01.059492 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:02.028457 T9001394C Write-Data Control setpoint: 57.30 | |
16:05:02.066483 B5001394C Write-Ack Control setpoint: 57.30 | |
16:05:02.697645 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:02.788822 B40111900 Read-Ack Relative modulation level: 25.00 | |
16:05:03.694389 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:03.790859 BC019394C Read-Ack Boiler water temperature: 57.30 | |
16:05:04.707260 T00630000 Read-Data Message ID 99: 0 | |
16:05:04.721308 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:05:04.796443 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:05:04.807287 AF0630000 Unk-DataId Message ID 99: 0 | |
16:05:05.724507 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:06.041074 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:06.908660 T9001394C Write-Data Control setpoint: 57.30 | |
16:05:06.943968 B5001394C Write-Ack Control setpoint: 57.30 | |
16:05:07.726394 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:07.890971 B40111900 Read-Ack Relative modulation level: 25.00 | |
16:05:08.902623 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:08.926978 BC019394F Read-Ack Boiler water temperature: 57.31 | |
16:05:09.741738 T001D0000 Read-Data Solar storage temperature: 0.00 | |
16:05:09.751552 R00740000 Read-Data Burner starts: 0 | |
16:05:09.890033 BC074FFFF Read-Ack Burner starts: 65535 | |
16:05:09.900363 AF01D0000 Unk-DataId Solar storage temperature: 0.00 | |
16:05:10.758782 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:10.944720 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:11.803661 T9001394C Write-Data Control setpoint: 57.30 | |
16:05:11.892130 B5001394C Write-Ack Control setpoint: 57.30 | |
16:05:12.764648 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:12.888520 BC0111800 Read-Ack Relative modulation level: 24.00 | |
16:05:13.907609 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:13.939992 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:05:14.790621 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:05:14.890632 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:05:15.789822 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:15.929462 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:16.796913 T9001394C Write-Data Control setpoint: 57.30 | |
16:05:16.862563 B5001394C Write-Ack Control setpoint: 57.30 | |
16:05:17.871130 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:17.878747 BC0111700 Read-Ack Relative modulation level: 23.00 | |
16:05:18.881857 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:18.912736 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:05:19.831073 T001B0000 Read-Data Outside temperature: 0.00 | |
16:05:19.854676 R80750000 Read-Data CH pump starts: 0 | |
16:05:19.913493 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:05:19.926434 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:05:20.824731 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:20.986039 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:21.832122 T9001394C Write-Data Control setpoint: 57.30 | |
16:05:21.986241 B5001394C Write-Ack Control setpoint: 57.30 | |
16:05:22.942227 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:22.994880 B40111600 Read-Ack Relative modulation level: 22.00 | |
16:05:24.143550 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:24.181609 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:05:24.889328 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:05:24.988970 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:05:26.193170 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:26.589578 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:27.009857 T10013966 Write-Data Control setpoint: 57.40 | |
16:05:27.024815 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:05:27.877804 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:27.971885 B40111500 Read-Ack Relative modulation level: 21.00 | |
16:05:29.060063 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:29.095298 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:05:30.289423 T10101580 Write-Data Room setpoint: 21.50 | |
16:05:30.327035 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:05:30.915040 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:31.283606 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:31.928160 T10013966 Write-Data Control setpoint: 57.40 | |
16:05:32.066152 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:05:33.156160 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:33.176700 BC0111400 Read-Ack Relative modulation level: 20.00 | |
16:05:33.939408 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:34.072987 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:05:34.944604 T901813B0 Write-Data Room temperature: 19.69 | |
16:05:35.066821 B501813B0 Write-Ack Room temperature: 19.69 | |
16:05:36.091329 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:36.498405 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:37.250675 T10013966 Write-Data Control setpoint: 57.40 | |
16:05:37.273006 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:05:38.110814 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:38.141757 BC0111400 Read-Ack Relative modulation level: 20.00 | |
16:05:38.980357 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:39.073771 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:05:40.119645 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:05:40.150373 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:05:40.197693 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:05:40.243040 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:05:41.346928 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:41.668049 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:42.190177 T10013966 Write-Data Control setpoint: 57.40 | |
16:05:42.227931 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:05:43.398167 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:43.430852 B40111300 Read-Ack Relative modulation level: 19.00 | |
16:05:44.026985 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:44.182212 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:05:45.038668 T00630000 Read-Data Message ID 99: 0 | |
16:05:45.068893 R00770000 Read-Data DHW burner starts: 0 | |
16:05:45.170010 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:05:45.191516 AF0630000 Unk-DataId Message ID 99: 0 | |
16:05:46.033612 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:46.278622 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:47.044550 T10013966 Write-Data Control setpoint: 57.40 | |
16:05:47.168797 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:05:48.036788 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:48.167490 BC0111200 Read-Ack Relative modulation level: 18.00 | |
16:05:49.160190 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:49.191229 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:05:50.039743 T00300000 Read-Data DHW setpoint boundaries: 0 0 | |
16:05:50.172132 BC0303C28 Read-Ack DHW setpoint boundaries: 60 40 | |
16:05:51.177435 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:51.377628 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:52.040521 T10013966 Write-Data Control setpoint: 57.40 | |
16:05:52.169193 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:05:53.225593 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:53.257323 BC0111100 Read-Ack Relative modulation level: 17.00 | |
16:05:54.045824 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:54.175520 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:05:55.042062 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:05:55.196241 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:05:56.116561 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:05:56.405934 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:05:57.044218 T10013966 Write-Data Control setpoint: 57.40 | |
16:05:57.168771 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:05:58.552012 T00110000 Read-Data Relative modulation level: 0.00 | |
16:05:58.577742 B40111000 Read-Ack Relative modulation level: 16.00 | |
16:05:59.047672 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:05:59.169404 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:06:00.019960 Command: SC=16:06/6 | |
16:06:00.073745 T001B0000 Read-Data Outside temperature: 0.00 | |
16:06:00.092216 R00780000 Read-Data Burner operation hours: 0 | |
16:06:00.169082 BC078153E Read-Ack Burner operation hours: 5438 | |
16:06:00.187277 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:06:01.041882 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:01.351167 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:02.053166 T10013966 Write-Data Control setpoint: 57.40 | |
16:06:02.166888 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:06:03.042689 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:03.166004 BC0110F00 Read-Ack Relative modulation level: 15.00 | |
16:06:04.177547 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:04.209965 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:06:05.190801 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:06:05.213833 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:06:06.042343 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:06.283000 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:07.037601 T10013966 Write-Data Control setpoint: 57.40 | |
16:06:07.154713 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:06:08.380171 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:08.410293 BC0110F00 Read-Ack Relative modulation level: 15.00 | |
16:06:09.038615 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:09.144478 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:06:10.045233 T10101580 Write-Data Room setpoint: 21.50 | |
16:06:10.149164 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:06:11.172418 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:11.476656 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:12.067577 T10013966 Write-Data Control setpoint: 57.40 | |
16:06:12.157526 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:06:13.066867 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:13.158925 B40110E00 Read-Ack Relative modulation level: 14.00 | |
16:06:14.101107 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:14.170580 BC0193980 Read-Ack Boiler water temperature: 57.50 | |
16:06:15.082175 T101813B8 Write-Data Room temperature: 19.72 | |
16:06:15.246165 BD01813B8 Write-Ack Room temperature: 19.72 | |
16:06:16.170022 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:16.466794 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:17.187608 T10013966 Write-Data Control setpoint: 57.40 | |
16:06:17.235090 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:06:18.103174 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:18.242219 B40110D00 Read-Ack Relative modulation level: 13.00 | |
16:06:19.112810 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:19.241707 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:06:20.121531 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:06:20.161039 R80790000 Read-Data CH pump operation hours: 0 | |
16:06:20.245488 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:06:20.274536 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:06:21.126939 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:21.483450 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:22.136457 T90013980 Write-Data Control setpoint: 57.50 | |
16:06:22.242146 B50013980 Write-Ack Control setpoint: 57.50 | |
16:06:23.152865 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:23.245349 BC0110C00 Read-Ack Relative modulation level: 12.00 | |
16:06:24.153653 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:24.246124 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:06:25.174709 T00630000 Read-Data Message ID 99: 0 | |
16:06:25.206518 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:06:25.285593 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:06:25.317164 AF0630000 Unk-DataId Message ID 99: 0 | |
16:06:26.166862 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:26.483868 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:27.182642 T90013980 Write-Data Control setpoint: 57.50 | |
16:06:27.341788 B50013980 Write-Ack Control setpoint: 57.50 | |
16:06:28.181809 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:28.340586 BC0110C00 Read-Ack Relative modulation level: 12.00 | |
16:06:29.251574 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:29.341005 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:06:30.381875 T80310000 Read-Data Max CH setpoint boundaries: 0 0 | |
16:06:30.416113 B40314B14 Read-Ack Max CH setpoint boundaries: 75 20 | |
16:06:31.208825 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:31.549657 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:32.215780 T90013980 Write-Data Control setpoint: 57.50 | |
16:06:32.347647 B50013980 Write-Ack Control setpoint: 57.50 | |
16:06:33.370899 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:33.407300 B40110B00 Read-Ack Relative modulation level: 11.00 | |
16:06:34.257535 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:34.351182 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:06:35.240732 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:06:35.342555 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:06:36.250045 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:36.599513 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:37.259476 T90013980 Write-Data Control setpoint: 57.50 | |
16:06:37.351524 B50013980 Write-Ack Control setpoint: 57.50 | |
16:06:38.283140 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:38.329755 BC0110A00 Read-Ack Relative modulation level: 10.00 | |
16:06:39.279574 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:39.442500 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:06:40.361001 T001B0000 Read-Data Outside temperature: 0.00 | |
16:06:40.393219 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:06:40.476837 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:06:40.506951 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:06:41.295836 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:41.711320 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:42.303358 T90013980 Write-Data Control setpoint: 57.50 | |
16:06:42.445527 B50013980 Write-Ack Control setpoint: 57.50 | |
16:06:43.316017 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:43.439797 BC0110A00 Read-Ack Relative modulation level: 10.00 | |
16:06:44.321784 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:44.442339 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:06:45.660298 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:06:45.705126 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:06:46.337746 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:46.662799 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:47.375347 T90013980 Write-Data Control setpoint: 57.50 | |
16:06:47.430187 B50013980 Write-Ack Control setpoint: 57.50 | |
16:06:48.377328 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:48.432899 BC0110900 Read-Ack Relative modulation level: 9.00 | |
16:06:49.367872 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:49.469243 B401939A3 Read-Ack Boiler water temperature: 57.64 | |
16:06:50.375272 T10101580 Write-Data Room setpoint: 21.50 | |
16:06:50.463319 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:06:51.390084 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:51.657492 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:52.384629 T90013980 Write-Data Control setpoint: 57.50 | |
16:06:52.542514 B50013980 Write-Ack Control setpoint: 57.50 | |
16:06:53.464581 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:53.515390 B40110800 Read-Ack Relative modulation level: 8.00 | |
16:06:54.410883 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:54.535725 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:06:55.486627 T901813C2 Write-Data Room temperature: 19.76 | |
16:06:55.549801 B501813C2 Write-Ack Room temperature: 19.76 | |
16:06:56.585712 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:06:56.879786 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:06:57.426402 T90013980 Write-Data Control setpoint: 57.50 | |
16:06:57.534891 B50013980 Write-Ack Control setpoint: 57.50 | |
16:06:58.764234 T00110000 Read-Data Relative modulation level: 0.00 | |
16:06:58.795668 B40110700 Read-Ack Relative modulation level: 7.00 | |
16:06:59.446122 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:06:59.541442 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:07:00.005891 Command: SC=16:07/6 | |
16:07:00.163886 SC: 16:07/6 | |
16:07:00.449571 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:07:00.479271 R00740000 Read-Data Burner starts: 0 | |
16:07:00.560097 BC074FFFF Read-Ack Burner starts: 65535 | |
16:07:00.591386 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:07:01.455987 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:01.742269 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:02.464936 T90013980 Write-Data Control setpoint: 57.50 | |
16:07:02.554922 B50013980 Write-Ack Control setpoint: 57.50 | |
16:07:03.677464 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:03.705148 B40110700 Read-Ack Relative modulation level: 7.00 | |
16:07:04.479999 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:04.634807 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:07:05.486125 T00630000 Read-Data Message ID 99: 0 | |
16:07:05.514629 R80750000 Read-Data CH pump starts: 0 | |
16:07:05.635102 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:07:05.666164 AF0630000 Unk-DataId Message ID 99: 0 | |
16:07:06.525332 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:06.878061 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:07.501368 T90013980 Write-Data Control setpoint: 57.50 | |
16:07:07.637023 B50013980 Write-Ack Control setpoint: 57.50 | |
16:07:08.596823 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:08.646674 BC0110600 Read-Ack Relative modulation level: 6.00 | |
16:07:09.517976 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:09.633163 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:07:10.645492 T10382800 Write-Data DHW setpoint: 40.00 | |
16:07:10.673068 BD0382800 Write-Ack DHW setpoint: 40.00 | |
16:07:11.533351 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:11.670973 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:12.694497 T90013980 Write-Data Control setpoint: 57.50 | |
16:07:12.720522 B50013980 Write-Ack Control setpoint: 57.50 | |
16:07:13.547708 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:13.641041 BC0110500 Read-Ack Relative modulation level: 5.00 | |
16:07:14.558781 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:14.650446 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:07:15.561344 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:07:15.728758 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:07:16.789734 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:17.103764 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:17.578865 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:17.731969 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:18.779654 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:18.806526 BC0110500 Read-Ack Relative modulation level: 5.00 | |
16:07:19.686946 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:19.729983 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:07:20.604607 T001B0000 Read-Data Outside temperature: 0.00 | |
16:07:20.635392 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:07:20.725846 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:07:20.751510 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:07:21.614420 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:21.977987 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:22.618219 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:22.725266 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:23.748483 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:23.779519 BC0110500 Read-Ack Relative modulation level: 5.00 | |
16:07:24.636586 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:24.731256 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:07:25.797485 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:07:25.832427 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:07:26.650215 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:27.028869 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:27.844219 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:27.866475 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:29.074232 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:29.096370 BC0110500 Read-Ack Relative modulation level: 5.00 | |
16:07:29.677854 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:29.823217 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:07:30.712557 T10101580 Write-Data Room setpoint: 21.50 | |
16:07:30.828802 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:07:31.694014 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:32.045727 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:32.787796 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:32.813764 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:33.798127 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:33.830299 BC0110500 Read-Ack Relative modulation level: 5.00 | |
16:07:34.808758 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:34.836174 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:07:36.044213 T901813C2 Write-Data Room temperature: 19.76 | |
16:07:36.112247 B501813C2 Write-Ack Room temperature: 19.76 | |
16:07:36.856338 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:37.001828 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:37.737785 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:37.901983 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:38.904718 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:38.934950 B40110400 Read-Ack Relative modulation level: 4.00 | |
16:07:39.756299 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:39.900957 B401939CA Read-Ack Boiler water temperature: 57.79 | |
16:07:40.965419 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:07:41.005448 R00770000 Read-Data DHW burner starts: 0 | |
16:07:41.064752 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:07:41.118797 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:07:42.092434 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:42.209563 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:43.001613 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:43.014461 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:43.858338 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:43.890622 BC0110300 Read-Ack Relative modulation level: 3.00 | |
16:07:44.801607 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:44.901818 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:07:45.836859 T00630000 Read-Data Message ID 99: 0 | |
16:07:45.874448 R00780000 Read-Data Burner operation hours: 0 | |
16:07:45.927849 BC078153E Read-Ack Burner operation hours: 5438 | |
16:07:45.976651 AF0630000 Unk-DataId Message ID 99: 0 | |
16:07:46.837281 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:47.031934 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:47.917605 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:47.953394 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:48.828081 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:48.928389 BC0110300 Read-Ack Relative modulation level: 3.00 | |
16:07:49.962997 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:50.025752 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:07:51.164483 T90395A00 Write-Data Max CH water setpoint: 90.00 | |
16:07:51.191909 B60394B00 Data-Inv Max CH water setpoint: 75.00 | |
16:07:51.848691 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:52.062612 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:52.858691 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:53.003680 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:54.059481 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:54.081214 B40110200 Read-Ack Relative modulation level: 2.00 | |
16:07:55.291574 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:07:55.315507 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:07:56.120648 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:07:56.156354 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:07:56.957524 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:07:57.294630 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:07:58.184210 T10013999 Write-Data Control setpoint: 57.60 | |
16:07:58.198676 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:07:58.979399 T00110000 Read-Data Relative modulation level: 0.00 | |
16:07:59.001434 B40110200 Read-Ack Relative modulation level: 2.00 | |
16:07:59.912783 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:00.000591 Command: SC=16:08/6 | |
16:08:00.014900 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:08:00.923167 T001B0000 Read-Data Outside temperature: 0.00 | |
16:08:00.945121 R80790000 Read-Data CH pump operation hours: 0 | |
16:08:01.015367 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:08:01.037676 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:08:02.251773 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:02.654019 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:03.072427 T10013999 Write-Data Control setpoint: 57.60 | |
16:08:03.098714 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:08:04.299199 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:04.354699 B40110200 Read-Ack Relative modulation level: 2.00 | |
16:08:05.119376 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:05.145857 B40193999 Read-Ack Boiler water temperature: 57.60 | |
16:08:06.347951 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:08:06.378722 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:08:07.166993 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:07.550717 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:08.023158 T10013999 Write-Data Control setpoint: 57.60 | |
16:08:08.104117 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:08:09.217115 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:09.249754 B40110100 Read-Ack Relative modulation level: 1.00 | |
16:08:10.061043 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:10.093841 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:08:11.002310 T10101580 Write-Data Room setpoint: 21.50 | |
16:08:11.111297 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:08:12.087265 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:12.202840 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:13.010291 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:13.106735 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:14.074781 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:14.182559 B40110100 Read-Ack Relative modulation level: 1.00 | |
16:08:15.025020 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:15.188149 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:08:16.033612 T101813CF Write-Data Room temperature: 19.81 | |
16:08:16.181744 BD01813CF Write-Ack Room temperature: 19.81 | |
16:08:17.045354 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:17.373386 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:18.053385 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:18.183828 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:19.059924 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:19.181012 B40110100 Read-Ack Relative modulation level: 1.00 | |
16:08:20.062586 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:20.185202 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:08:21.095089 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:08:21.128988 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:08:21.192464 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:08:21.229635 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:08:22.102267 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:22.387932 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:23.085128 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:23.183099 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:24.195807 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:24.232042 B40110100 Read-Ack Relative modulation level: 1.00 | |
16:08:25.175896 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:25.208157 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:08:26.420135 T00630000 Read-Data Message ID 99: 0 | |
16:08:26.452603 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:08:26.516234 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:08:26.574292 AF0630000 Unk-DataId Message ID 99: 0 | |
16:08:27.238721 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:27.581380 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:28.128461 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:28.287317 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:29.285902 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:29.311690 B40110100 Read-Ack Relative modulation level: 1.00 | |
16:08:30.926170 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:30.958185 BC01939BA Read-Ack Boiler water temperature: 57.73 | |
16:08:31.157766 T80640000 Read-Data Remote override function: 00000000 | |
16:08:31.182079 R00740000 Read-Data Burner starts: 0 | |
16:08:31.280134 BC074FFFF Read-Ack Burner starts: 65535 | |
16:08:31.307673 A40640101 Read-Ack Remote override function: 00000001 | |
- Manual change priority: enable overrule (1) | |
- Program change priority: disable overrule (0) | |
16:08:32.179475 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:32.531845 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:33.166079 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:33.280335 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:34.200323 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:34.291444 B40110100 Read-Ack Relative modulation level: 1.00 | |
16:08:35.183664 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:35.283897 B401939CC Read-Ack Boiler water temperature: 57.80 | |
16:08:36.239346 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:08:36.297660 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:08:37.325777 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:37.645059 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:38.213856 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:38.310188 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:39.216356 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:39.380691 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:08:40.349734 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:40.383653 B401939CC Read-Ack Boiler water temperature: 57.80 | |
16:08:41.230448 T001B0000 Read-Data Outside temperature: 0.00 | |
16:08:41.254922 R80750000 Read-Data CH pump starts: 0 | |
16:08:41.384486 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:08:41.412854 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:08:42.321991 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:42.651355 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:43.382911 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:43.419117 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:44.377056 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:44.410241 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:08:45.675194 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:45.712213 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:08:46.274183 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:08:46.379801 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:08:47.309133 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:47.622449 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:48.298294 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:48.391172 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:49.302282 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:49.394842 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:08:50.310215 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:50.406537 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:08:51.396534 T10101580 Write-Data Room setpoint: 21.50 | |
16:08:51.492804 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:08:52.325916 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:52.558562 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:53.351302 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:53.481037 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:54.339730 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:54.463944 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:08:55.374873 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:08:55.470248 BC01939B3 Read-Ack Boiler water temperature: 57.70 | |
16:08:56.355928 T101813D7 Write-Data Room temperature: 19.84 | |
16:08:56.460423 BD01813D7 Write-Ack Room temperature: 19.84 | |
16:08:57.365331 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:08:57.636501 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:08:58.576444 T900139B3 Write-Data Control setpoint: 57.70 | |
16:08:58.610976 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:08:59.377896 T00110000 Read-Data Relative modulation level: 0.00 | |
16:08:59.468005 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:00.013197 Command: SC=16:09/6 | |
16:09:00.087106 SC: 16:09/6 | |
16:09:00.384368 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:00.483636 BC01939C7 Read-Ack Boiler water temperature: 57.78 | |
16:09:01.670871 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:09:01.706602 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:09:01.760871 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:09:01.814966 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:09:02.395824 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:02.663240 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:03.410580 T900139B3 Write-Data Control setpoint: 57.70 | |
16:09:03.559830 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:09:04.473788 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:04.561655 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:05.420552 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:05.563990 B401939CC Read-Ack Boiler water temperature: 57.80 | |
16:09:06.427874 T00630000 Read-Data Message ID 99: 0 | |
16:09:06.460379 R00770000 Read-Data DHW burner starts: 0 | |
16:09:06.566272 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:09:06.607095 AF0630000 Unk-DataId Message ID 99: 0 | |
16:09:07.437059 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:07.741763 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:08.577110 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:08.609440 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:09.453429 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:09.559895 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:10.459822 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:10.559919 B401939CC Read-Ack Boiler water temperature: 57.80 | |
16:09:11.470541 T00740000 Read-Data Burner starts: 0 | |
16:09:11.562225 BC074FFFF Read-Ack Burner starts: 65535 | |
16:09:12.472338 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:12.831080 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:13.480551 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:13.571522 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:14.549397 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:14.607887 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:15.496557 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:15.660417 B401939CC Read-Ack Boiler water temperature: 57.80 | |
16:09:16.508785 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:09:16.663478 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:09:17.512987 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:17.926509 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:18.854471 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:18.890228 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:19.531974 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:19.660977 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:20.578559 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:20.689709 BC01939E6 Read-Ack Boiler water temperature: 57.90 | |
16:09:21.718645 T001B0000 Read-Data Outside temperature: 0.00 | |
16:09:21.756695 R00780000 Read-Data Burner operation hours: 0 | |
16:09:21.813450 BC078153E Read-Ack Burner operation hours: 5438 | |
16:09:21.871231 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:09:22.562212 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:22.830444 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:23.574703 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:23.662920 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:24.572304 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:24.665904 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:25.812618 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:25.856789 BC01939E6 Read-Ack Boiler water temperature: 57.90 | |
16:09:26.630486 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:09:26.694535 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:09:27.596519 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:27.872489 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:28.606041 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:28.759454 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:29.620274 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:29.743396 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:30.632459 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:30.745437 BC01939E6 Read-Ack Boiler water temperature: 57.90 | |
16:09:31.628653 T10101580 Write-Data Room setpoint: 21.50 | |
16:09:31.743001 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:09:32.636993 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:33.030244 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:34.005327 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:34.034701 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:34.653410 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:34.747050 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:35.664131 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:35.753199 BC01939E6 Read-Ack Boiler water temperature: 57.90 | |
16:09:36.667593 T101813D7 Write-Data Room temperature: 19.84 | |
16:09:36.762387 BD01813D7 Write-Ack Room temperature: 19.84 | |
16:09:37.674924 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:37.989057 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:38.925463 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:38.958124 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:39.687968 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:39.846220 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:40.694553 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:40.845230 BC01939E6 Read-Ack Boiler water temperature: 57.90 | |
16:09:41.785279 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:09:41.811726 R80790000 Read-Data CH pump operation hours: 0 | |
16:09:41.867628 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:09:41.917887 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:09:43.015295 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:43.356495 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:43.718454 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:43.850477 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:44.758492 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:44.846586 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:45.748917 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:45.844507 BC01939FD Read-Ack Boiler water temperature: 57.99 | |
16:09:46.836979 T00630000 Read-Data Message ID 99: 0 | |
16:09:46.870841 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:09:46.926349 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:09:46.973466 AF0630000 Unk-DataId Message ID 99: 0 | |
16:09:47.750504 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:48.094043 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:48.762306 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:48.853161 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:49.764307 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:49.859458 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:50.797833 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:50.868967 B40193A00 Read-Ack Boiler water temperature: 58.00 | |
16:09:52.027409 T00770000 Read-Data DHW burner starts: 0 | |
16:09:52.077696 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:09:52.872422 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:53.295244 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:53.801557 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:53.944995 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:54.876941 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:54.922129 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:09:56.125075 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:09:56.155499 B40193A00 Read-Ack Boiler water temperature: 58.00 | |
16:09:56.943643 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:09:56.972295 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:09:58.171800 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:09:58.397752 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:09:58.850878 T100139CC Write-Data Control setpoint: 57.80 | |
16:09:58.949716 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:09:59.857113 T00110000 Read-Data Relative modulation level: 0.00 | |
16:09:59.950995 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:00.017489 Command: SC=16:10/6 | |
16:10:00.162722 SC: 16:10/6 | |
16:10:01.040400 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:01.070286 B40193A00 Read-Ack Boiler water temperature: 58.00 | |
16:10:02.266869 T001B0000 Read-Data Outside temperature: 0.00 | |
16:10:02.275901 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:10:02.288056 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:10:02.299065 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:10:03.086009 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:03.471690 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:03.913113 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:04.042413 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:05.143551 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:05.175131 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:05.978571 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:06.025534 B40193A00 Read-Ack Boiler water temperature: 58.00 | |
16:10:07.206609 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:10:07.226198 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:10:07.920933 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:08.322510 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:09.230280 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:09.271940 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:10.049562 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:10.094227 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:11.278141 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:11.302058 B40193A00 Read-Ack Boiler water temperature: 58.00 | |
16:10:12.097062 T10101580 Write-Data Room setpoint: 21.50 | |
16:10:12.135795 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:10:13.326049 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:13.491803 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:14.155119 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:14.210892 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:15.308743 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:15.346157 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:16.192395 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:16.221032 BC0193A19 Read-Ack Boiler water temperature: 58.10 | |
16:10:17.016497 T101813DE Write-Data Room temperature: 19.87 | |
16:10:17.125813 BD01813DE Write-Ack Room temperature: 19.87 | |
16:10:18.002771 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:18.290283 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:19.004637 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:19.123883 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:20.017718 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:20.124339 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:21.026263 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:21.144327 BC0193A19 Read-Ack Boiler water temperature: 58.10 | |
16:10:22.027123 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:10:22.059928 R00740000 Read-Data Burner starts: 0 | |
16:10:22.123738 BC074FFFF Read-Ack Burner starts: 65535 | |
16:10:22.181444 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:10:23.156497 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:23.675127 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:24.189836 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:24.220282 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:25.053270 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:25.144219 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:26.061751 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:26.223309 BC0193A19 Read-Ack Boiler water temperature: 58.10 | |
16:10:27.072443 T00630000 Read-Data Message ID 99: 0 | |
16:10:27.102934 R80750000 Read-Data CH pump starts: 0 | |
16:10:27.223411 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:10:27.256899 AF0630000 Unk-DataId Message ID 99: 0 | |
16:10:28.369705 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:28.692451 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:29.300647 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:29.332301 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:30.094727 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:30.222677 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:31.210534 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:31.233332 BC0193A19 Read-Ack Boiler water temperature: 58.10 | |
16:10:32.111286 T00780000 Read-Data Burner operation hours: 0 | |
16:10:32.228154 BC078153E Read-Ack Burner operation hours: 5438 | |
16:10:33.116587 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:33.477874 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:34.128271 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:34.222240 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:35.133500 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:35.227121 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:36.263283 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:36.304716 BC0193A19 Read-Ack Boiler water temperature: 58.10 | |
16:10:37.326302 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:10:37.378199 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:10:38.199105 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:38.505985 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:39.164419 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:39.328541 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:40.383439 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:40.418541 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:41.181483 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:41.325523 BC0193A19 Read-Ack Boiler water temperature: 58.10 | |
16:10:42.407680 T001B0000 Read-Data Outside temperature: 0.00 | |
16:10:42.440459 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:10:42.490324 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:10:42.534125 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:10:43.195128 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:43.585239 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:44.382117 T900139E6 Write-Data Control setpoint: 57.90 | |
16:10:44.421161 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:10:45.209893 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:45.304818 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:46.222044 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:46.312903 B40193A2B Read-Ack Boiler water temperature: 58.17 | |
16:10:47.226237 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:10:47.323246 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:10:48.553722 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:49.004096 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:49.540032 T10013A00 Write-Data Control setpoint: 58.00 | |
16:10:49.572446 BD0013A00 Write-Ack Control setpoint: 58.00 | |
16:10:50.249712 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:50.407241 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:51.256497 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:51.406557 B40193A33 Read-Ack Boiler water temperature: 58.20 | |
16:10:52.309774 T10101580 Write-Data Room setpoint: 21.50 | |
16:10:52.406056 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:10:53.273276 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:53.424114 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:54.279833 T10013A00 Write-Data Control setpoint: 58.00 | |
16:10:54.409896 BD0013A00 Write-Ack Control setpoint: 58.00 | |
16:10:55.289116 T00110000 Read-Data Relative modulation level: 0.00 | |
16:10:55.405067 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:10:56.295897 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:10:56.404867 B40193A33 Read-Ack Boiler water temperature: 58.20 | |
16:10:57.303652 T101813EB Write-Data Room temperature: 19.92 | |
16:10:57.407026 BD01813EB Write-Ack Room temperature: 19.92 | |
16:10:58.311383 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:10:58.819244 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:10:59.318738 T90013A19 Write-Data Control setpoint: 58.10 | |
16:10:59.411670 B50013A19 Write-Ack Control setpoint: 58.10 | |
16:11:00.001463 Command: SC=16:11/6 | |
16:11:00.128058 SC: 16:11/6 | |
16:11:00.342471 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:00.404395 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:01.660893 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:01.699664 B40193A33 Read-Ack Boiler water temperature: 58.20 | |
16:11:02.480732 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:11:02.512500 R00770000 Read-Data DHW burner starts: 0 | |
16:11:02.561439 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:11:02.611605 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:11:03.372325 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:03.628242 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:04.371178 T10013A33 Write-Data Control setpoint: 58.20 | |
16:11:04.505575 BD0013A33 Write-Ack Control setpoint: 58.20 | |
16:11:05.365991 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:05.509327 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:06.575235 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:06.607401 B40193A33 Read-Ack Boiler water temperature: 58.20 | |
16:11:07.393034 T00630000 Read-Data Message ID 99: 0 | |
16:11:07.424915 R00780000 Read-Data Burner operation hours: 0 | |
16:11:07.508531 BC078153E Read-Ack Burner operation hours: 5438 | |
16:11:07.530180 AF0630000 Unk-DataId Message ID 99: 0 | |
16:11:08.624892 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:08.818279 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:09.396708 T10013A33 Write-Data Control setpoint: 58.20 | |
16:11:09.507007 BD0013A33 Write-Ack Control setpoint: 58.20 | |
16:11:10.670975 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:10.711106 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:11.514987 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:11.552357 B40193A33 Read-Ack Boiler water temperature: 58.20 | |
16:11:12.414427 T007B0000 Read-Data DHW burner operation hours: 0 | |
16:11:12.507991 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:11:13.537397 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:13.917377 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:14.429270 T90013A4C Write-Data Control setpoint: 58.30 | |
16:11:14.526277 B50013A4C Write-Ack Control setpoint: 58.30 | |
16:11:15.591427 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:15.621242 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:16.445731 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:16.603873 BC0193A5E Read-Ack Boiler water temperature: 58.37 | |
16:11:17.455345 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:11:17.601692 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:11:18.457694 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:18.801265 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:19.464458 T10013A66 Write-Data Control setpoint: 58.40 | |
16:11:19.606993 BD0013A66 Write-Ack Control setpoint: 58.40 | |
16:11:20.470914 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:20.602316 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:21.480135 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:21.602870 B40193A66 Read-Ack Boiler water temperature: 58.40 | |
16:11:22.549496 T001B0000 Read-Data Outside temperature: 0.00 | |
16:11:22.582601 R80790000 Read-Data CH pump operation hours: 0 | |
16:11:22.648162 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:11:22.709938 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:11:23.496149 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:23.852722 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:24.500308 T90013A80 Write-Data Control setpoint: 58.50 | |
16:11:24.624701 B50013A80 Write-Ack Control setpoint: 58.50 | |
16:11:25.505731 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:25.601247 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:26.513634 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:26.613729 B40193A66 Read-Ack Boiler water temperature: 58.40 | |
16:11:27.521989 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:11:27.690689 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:11:28.693305 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:29.075434 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:29.648112 T10013A99 Write-Data Control setpoint: 58.60 | |
16:11:29.678514 BD0013A99 Write-Ack Control setpoint: 58.60 | |
16:11:30.744937 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:30.788690 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:31.971831 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:32.002375 B40193A66 Read-Ack Boiler water temperature: 58.40 | |
16:11:32.789445 T10101580 Write-Data Room setpoint: 21.50 | |
16:11:32.822603 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:11:33.609158 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:33.943379 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:34.660462 T90013AB3 Write-Data Control setpoint: 58.70 | |
16:11:34.717143 B50013AB3 Write-Ack Control setpoint: 58.70 | |
16:11:35.657142 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:35.692017 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:36.910102 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:36.941582 B40193A66 Read-Ack Boiler water temperature: 58.40 | |
16:11:37.704288 T101813EB Write-Data Room temperature: 19.92 | |
16:11:37.737944 BD01813EB Write-Ack Room temperature: 19.92 | |
16:11:38.614152 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:39.028474 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:39.662386 T90013AE6 Write-Data Control setpoint: 58.90 | |
16:11:39.781159 B50013AE6 Write-Ack Control setpoint: 58.90 | |
16:11:40.984784 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:41.012292 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:41.801504 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:41.830568 B40193A66 Read-Ack Boiler water temperature: 58.40 | |
16:11:43.030831 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:11:43.058778 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:11:43.107151 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:11:43.150465 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:11:43.840565 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:44.242586 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:44.668794 T900139B3 Write-Data Control setpoint: 57.70 | |
16:11:44.785737 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:11:45.842074 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:45.875663 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:46.716535 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:46.778449 BC0193A80 Read-Ack Boiler water temperature: 58.50 | |
16:11:47.944102 T00630000 Read-Data Message ID 99: 0 | |
16:11:47.974874 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:11:48.027275 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:11:48.080266 AF0630000 Unk-DataId Message ID 99: 0 | |
16:11:48.766003 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:49.139672 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:49.691035 T90013980 Write-Data Control setpoint: 57.50 | |
16:11:49.787400 B50013980 Write-Ack Control setpoint: 57.50 | |
16:11:50.812679 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:50.856404 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:51.703543 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:51.802068 B40193A7D Read-Ack Boiler water temperature: 58.49 | |
16:11:52.862469 T806D0000 Read-Data Message ID 109: 0 | |
16:11:52.905305 R00740000 Read-Data Burner starts: 0 | |
16:11:52.967053 BC074FFFF Read-Ack Burner starts: 65535 | |
16:11:53.028759 A706D0000 Unk-DataId Message ID 109: 0 | |
16:11:53.718951 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:54.076749 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:54.727215 T90013980 Write-Data Control setpoint: 57.50 | |
16:11:54.878384 B50013980 Write-Ack Control setpoint: 57.50 | |
16:11:56.137021 T00110000 Read-Data Relative modulation level: 0.00 | |
16:11:56.173630 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:11:56.976355 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:11:57.007328 BC0193A80 Read-Ack Boiler water temperature: 58.50 | |
16:11:57.799397 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:11:57.893401 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:11:59.010974 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:11:59.289772 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:11:59.761101 T10013999 Write-Data Control setpoint: 57.60 | |
16:11:59.883930 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:12:00.011903 Command: SC=16:12/6 | |
16:12:00.151528 SC: 16:12/6 | |
16:12:01.063110 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:01.090558 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:01.871223 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:01.903110 B40193A78 Read-Ack Boiler water temperature: 58.47 | |
16:12:03.144064 T001B0000 Read-Data Outside temperature: 0.00 | |
16:12:03.178860 R80750000 Read-Data CH pump starts: 0 | |
16:12:03.233661 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:12:03.277434 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:12:03.944968 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:04.357906 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:04.795601 T90013980 Write-Data Control setpoint: 57.50 | |
16:12:04.888924 B50013980 Write-Ack Control setpoint: 57.50 | |
16:12:05.828093 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:05.958845 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:07.197224 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:07.223470 B40193A66 Read-Ack Boiler water temperature: 58.40 | |
16:12:07.818547 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:12:07.970788 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:12:08.822259 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:09.035202 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:09.831307 T90013980 Write-Data Control setpoint: 57.50 | |
16:12:09.960650 B50013980 Write-Ack Control setpoint: 57.50 | |
16:12:10.842771 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:10.958896 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:12.111699 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:12.145950 BC0193A7A Read-Ack Boiler water temperature: 58.48 | |
16:12:12.931414 T10101580 Write-Data Room setpoint: 21.50 | |
16:12:12.977010 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:12:14.158843 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:14.355445 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:14.872723 T90013980 Write-Data Control setpoint: 57.50 | |
16:12:14.963002 B50013980 Write-Ack Control setpoint: 57.50 | |
16:12:15.875633 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:15.970055 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:17.052783 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:17.085960 BC0193A80 Read-Ack Boiler water temperature: 58.50 | |
16:12:17.895014 T101813F5 Write-Data Room temperature: 19.96 | |
16:12:17.984899 BD01813F5 Write-Ack Room temperature: 19.96 | |
16:12:19.095764 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:19.400015 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:19.915276 T90013980 Write-Data Control setpoint: 57.50 | |
16:12:20.063735 B50013980 Write-Ack Control setpoint: 57.50 | |
16:12:21.014847 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:21.063772 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:21.926273 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:22.066724 BC0193A80 Read-Ack Boiler water temperature: 58.50 | |
16:12:22.934085 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:12:22.965779 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:12:23.063664 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:12:23.091973 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:12:23.952456 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:24.185422 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:24.949705 T10013999 Write-Data Control setpoint: 57.60 | |
16:12:25.068054 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:12:26.041631 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:26.073107 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:26.964338 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:27.066255 BC0193A80 Read-Ack Boiler water temperature: 58.50 | |
16:12:28.087200 T00630000 Read-Data Message ID 99: 0 | |
16:12:28.123479 R00770000 Read-Data DHW burner starts: 0 | |
16:12:28.176624 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:12:28.237574 AF0630000 Unk-DataId Message ID 99: 0 | |
16:12:28.979317 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:29.329544 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:30.158155 T900139B3 Write-Data Control setpoint: 57.70 | |
16:12:30.209530 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:12:31.194304 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:31.228405 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:32.185589 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:32.223092 BC0193A80 Read-Ack Boiler water temperature: 58.50 | |
16:12:33.016239 T806E0000 Read-Data Message ID 110: 0 | |
16:12:33.045678 R00780000 Read-Data Burner operation hours: 0 | |
16:12:33.148578 BC078153E Read-Ack Burner operation hours: 5438 | |
16:12:33.177359 A706E0000 Unk-DataId Message ID 110: 0 | |
16:12:34.019708 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:34.213348 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:35.062267 T10013999 Write-Data Control setpoint: 57.60 | |
16:12:35.151780 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:12:36.279003 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:36.321573 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:37.099746 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:37.144860 BC0193A8A Read-Ack Boiler water temperature: 58.54 | |
16:12:38.328746 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:12:38.375551 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:12:39.151452 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:39.477302 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:40.376996 T10013999 Write-Data Control setpoint: 57.60 | |
16:12:40.411001 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:12:41.239892 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:41.268630 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:42.084393 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:42.179205 B40193A99 Read-Ack Boiler water temperature: 58.60 | |
16:12:43.242295 T001B0000 Read-Data Outside temperature: 0.00 | |
16:12:43.267551 R80790000 Read-Data CH pump operation hours: 0 | |
16:12:43.309781 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:12:43.348937 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:12:44.101308 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:44.415764 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:45.110551 T90013980 Write-Data Control setpoint: 57.50 | |
16:12:45.286191 B50013980 Write-Ack Control setpoint: 57.50 | |
16:12:46.930098 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:46.992161 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:47.133326 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:47.237109 B40193A99 Read-Ack Boiler water temperature: 58.60 | |
16:12:48.157120 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:12:48.243684 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:12:49.149380 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:49.477001 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:50.205409 T90013980 Write-Data Control setpoint: 57.50 | |
16:12:50.278006 B50013980 Write-Ack Control setpoint: 57.50 | |
16:12:51.435309 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:51.464613 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:52.252707 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:52.349723 B40193A99 Read-Ack Boiler water temperature: 58.60 | |
16:12:53.481396 T10101580 Write-Data Room setpoint: 21.50 | |
16:12:53.517034 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:12:54.335214 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:12:54.615114 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:12:55.207362 T10013999 Write-Data Control setpoint: 57.60 | |
16:12:55.344306 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:12:56.348530 T00110000 Read-Data Relative modulation level: 0.00 | |
16:12:56.378366 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:12:57.579068 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:12:57.607577 B40193A99 Read-Ack Boiler water temperature: 58.60 | |
16:12:58.395520 T10181402 Write-Data Room temperature: 20.01 | |
16:12:58.426695 BD0181402 Write-Ack Room temperature: 20.01 | |
16:12:59.625484 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:00.035985 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:00.324064 Command: SC=16:13/6 | |
16:13:00.353139 T10013999 Write-Data Control setpoint: 57.60 | |
16:13:00.376781 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:13:01.674792 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:01.704110 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:02.493447 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:02.528188 B40193A99 Read-Ack Boiler water temperature: 58.60 | |
16:13:03.312832 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:13:03.339321 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:13:03.440472 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:13:03.474296 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:13:04.283860 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:04.631814 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:05.361181 T900139B3 Write-Data Control setpoint: 57.70 | |
16:13:05.450477 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:13:06.514710 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:06.532478 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:07.306198 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:07.446477 B40193A99 Read-Ack Boiler water temperature: 58.60 | |
16:13:08.313809 T00630000 Read-Data Message ID 99: 0 | |
16:13:08.351043 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:13:08.448592 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:13:08.488317 AF0630000 Unk-DataId Message ID 99: 0 | |
16:13:09.456401 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:09.841401 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:10.369825 T100139CC Write-Data Control setpoint: 57.80 | |
16:13:10.445500 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:13:11.508364 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:11.540195 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:12.734570 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:12.770490 B40193A9C Read-Ack Boiler water temperature: 58.61 | |
16:13:13.553126 T006F0000 Read-Data Message ID 111: 0 | |
16:13:13.582465 R00740000 Read-Data Burner starts: 0 | |
16:13:13.640300 BC074FFFF Read-Ack Burner starts: 65535 | |
16:13:13.705748 AF06F0000 Unk-DataId Message ID 111: 0 | |
16:13:14.356258 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:14.654838 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:15.604146 T900139B3 Write-Data Control setpoint: 57.70 | |
16:13:15.633834 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:13:16.421625 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:16.486175 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:17.539875 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:17.587442 BC0193AA1 Read-Ack Boiler water temperature: 58.63 | |
16:13:18.389474 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:13:18.524219 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:13:19.394679 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:19.694650 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:20.400188 T900139B3 Write-Data Control setpoint: 57.70 | |
16:13:20.539599 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:13:21.433606 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:21.522278 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:22.417643 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:22.527660 BC0193AB0 Read-Ack Boiler water temperature: 58.69 | |
16:13:23.424978 T001B0000 Read-Data Outside temperature: 0.00 | |
16:13:23.458695 R80750000 Read-Data CH pump starts: 0 | |
16:13:23.536949 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:13:23.578757 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:13:24.430045 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:24.537441 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:25.717664 T900139B3 Write-Data Control setpoint: 57.70 | |
16:13:25.752486 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:13:26.679064 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:26.711172 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:27.478833 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:27.548301 BC0193AB3 Read-Ack Boiler water temperature: 58.70 | |
16:13:28.490145 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:13:28.629582 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:13:29.568148 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:29.853801 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:30.472659 T900139B3 Write-Data Control setpoint: 57.70 | |
16:13:30.624453 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:13:31.576195 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:31.626149 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:32.843550 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:32.887148 BC0193AB3 Read-Ack Boiler water temperature: 58.70 | |
16:13:33.646335 T10101580 Write-Data Room setpoint: 21.50 | |
16:13:33.656083 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:13:34.792424 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:35.225233 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:35.749943 T100139CC Write-Data Control setpoint: 57.80 | |
16:13:35.797094 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:13:36.900291 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:36.928168 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:37.720423 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:37.748871 BC0193AB3 Read-Ack Boiler water temperature: 58.70 | |
16:13:38.948706 T10181402 Write-Data Room temperature: 20.01 | |
16:13:38.977307 BD0181402 Write-Ack Room temperature: 20.01 | |
16:13:39.533380 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:39.935331 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:40.586117 T900139E6 Write-Data Control setpoint: 57.90 | |
16:13:40.635095 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:13:41.815038 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:41.823496 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:42.644070 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:42.690614 BC0193AB3 Read-Ack Boiler water temperature: 58.70 | |
16:13:43.841868 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:13:43.882525 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:13:43.951056 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:13:44.024966 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:13:44.609634 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:44.763612 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:45.847449 T10013900 Write-Data Control setpoint: 57.00 | |
16:13:45.860716 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:13:46.732005 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:46.739141 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:47.596933 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:47.709189 BC0193AB3 Read-Ack Boiler water temperature: 58.70 | |
16:13:48.777670 T00630000 Read-Data Message ID 99: 0 | |
16:13:48.810127 R00770000 Read-Data DHW burner starts: 0 | |
16:13:48.881581 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:13:48.952004 AF0630000 Unk-DataId Message ID 99: 0 | |
16:13:49.627447 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:49.879277 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:50.617479 T10013900 Write-Data Control setpoint: 57.00 | |
16:13:50.721433 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:13:51.650407 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:51.695254 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:52.635417 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:52.728629 BC0193AB3 Read-Ack Boiler water temperature: 58.70 | |
16:13:53.692690 T80700000 Read-Data Message ID 112: 0 | |
16:13:53.701458 R00780000 Read-Data Burner operation hours: 0 | |
16:13:53.736385 BC078153E Read-Ack Burner operation hours: 5438 | |
16:13:53.744097 A70700000 Unk-DataId Message ID 112: 0 | |
16:13:54.809585 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:55.155404 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:13:55.753849 T90013919 Write-Data Control setpoint: 57.10 | |
16:13:55.797264 B50013919 Write-Ack Control setpoint: 57.10 | |
16:13:56.972236 T00110000 Read-Data Relative modulation level: 0.00 | |
16:13:56.997760 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:13:57.791530 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:13:57.824709 BC0193AB5 Read-Ack Boiler water temperature: 58.71 | |
16:13:59.054282 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:13:59.082296 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:13:59.679079 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:13:59.821602 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:00.001438 Command: SC=16:14/6 | |
16:14:00.078769 SC: 16:14/6 | |
16:14:00.734039 T90013919 Write-Data Control setpoint: 57.10 | |
16:14:00.794805 B50013919 Write-Ack Control setpoint: 57.10 | |
16:14:01.754754 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:01.826676 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:02.736803 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:02.780206 B40193ACC Read-Ack Boiler water temperature: 58.80 | |
16:14:03.718298 T001B0000 Read-Data Outside temperature: 0.00 | |
16:14:03.740447 R80790000 Read-Data CH pump operation hours: 0 | |
16:14:03.870989 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:14:03.897698 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:14:04.784974 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:05.084629 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:05.778100 T10013933 Write-Data Control setpoint: 57.20 | |
16:14:05.830645 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:14:06.734724 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:06.877606 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:07.748427 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:07.837382 B40193ACC Read-Ack Boiler water temperature: 58.80 | |
16:14:08.791596 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:14:08.980484 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:14:09.776698 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:09.990217 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:10.898481 T9001394C Write-Data Control setpoint: 57.30 | |
16:14:10.940142 B5001394C Write-Ack Control setpoint: 57.30 | |
16:14:12.150649 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:12.157358 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:12.982805 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:13.014995 BC0193AD9 Read-Ack Boiler water temperature: 58.85 | |
16:14:13.786131 T10101580 Write-Data Room setpoint: 21.50 | |
16:14:13.892410 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:14:14.842695 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:15.225989 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:15.829455 T10013966 Write-Data Control setpoint: 57.40 | |
16:14:15.899155 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:14:17.047332 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:17.077616 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:18.683783 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:18.737901 BC0193AD9 Read-Ack Boiler water temperature: 58.85 | |
16:14:18.825713 T9018140C Write-Data Room temperature: 20.05 | |
16:14:18.999089 B5018140C Write-Ack Room temperature: 20.05 | |
16:14:19.859154 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:20.308176 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:22.002798 T10013966 Write-Data Control setpoint: 57.40 | |
16:14:22.039372 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:14:22.091387 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:22.137897 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:23.007288 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:23.032454 B40193ACC Read-Ack Boiler water temperature: 58.80 | |
16:14:24.233838 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:14:24.260362 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:14:24.304619 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:14:24.343148 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:14:24.872621 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:25.153194 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:25.883402 T90013980 Write-Data Control setpoint: 57.50 | |
16:14:25.996918 B50013980 Write-Ack Control setpoint: 57.50 | |
16:14:27.783340 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:27.790304 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:27.896609 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:27.992437 B40193ACC Read-Ack Boiler water temperature: 58.80 | |
16:14:28.908961 T00630000 Read-Data Message ID 99: 0 | |
16:14:28.933363 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:14:29.002351 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:14:29.025345 AF0630000 Unk-DataId Message ID 99: 0 | |
16:14:29.919061 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:30.192359 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:30.923805 T10013999 Write-Data Control setpoint: 57.60 | |
16:14:31.013547 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:14:31.929194 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:32.095060 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:32.935699 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:33.096305 B40193ACC Read-Ack Boiler water temperature: 58.80 | |
16:14:33.944590 T1002010B Write-Data Master configuration: 00000001 11 | |
- Smart power: supported (1) | |
16:14:34.094191 BD002010B Write-Ack Master configuration: 00000001 11 | |
- Smart power: supported (1) | |
16:14:34.953117 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:35.215341 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:35.978632 T900139B3 Write-Data Control setpoint: 57.70 | |
16:14:36.113610 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:14:37.113914 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:37.204312 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:37.974743 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:38.100816 B40193AD1 Read-Ack Boiler water temperature: 58.82 | |
16:14:38.985336 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:14:39.094527 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:14:39.998968 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:40.236438 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:41.002961 T100139CC Write-Data Control setpoint: 57.80 | |
16:14:41.095392 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:14:42.027597 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:42.075801 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:43.256071 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:43.275657 BC0193AE6 Read-Ack Boiler water temperature: 58.90 | |
16:14:44.054603 T001B0000 Read-Data Outside temperature: 0.00 | |
16:14:44.088140 R00740000 Read-Data Burner starts: 0 | |
16:14:44.141973 BC074FFFF Read-Ack Burner starts: 65535 | |
16:14:44.194593 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:14:45.030214 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:45.249354 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:46.043961 T900139E6 Write-Data Control setpoint: 57.90 | |
16:14:46.173107 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:14:47.313043 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:47.335728 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:48.171730 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:48.199789 BC0193AE6 Read-Ack Boiler water temperature: 58.90 | |
16:14:49.090595 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:14:49.187255 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:14:50.070649 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:50.486444 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:51.077997 T10013999 Write-Data Control setpoint: 57.60 | |
16:14:51.172131 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:14:52.267644 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:52.291227 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:53.906940 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:53.933442 BC0193AE6 Read-Ack Boiler water temperature: 58.90 | |
16:14:54.103885 T10101580 Write-Data Room setpoint: 21.50 | |
16:14:54.274179 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:14:55.112545 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:14:55.364124 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:14:56.362353 T90013980 Write-Data Control setpoint: 57.50 | |
16:14:56.371236 B50013980 Write-Ack Control setpoint: 57.50 | |
16:14:57.184301 T00110000 Read-Data Relative modulation level: 0.00 | |
16:14:57.271833 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:14:58.411916 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:14:58.443976 BC0193AE6 Read-Ack Boiler water temperature: 58.90 | |
16:14:59.236195 T10181419 Write-Data Room temperature: 20.10 | |
16:14:59.280064 BD0181419 Write-Ack Room temperature: 20.10 | |
16:15:00.016343 Command: SC=16:15/6 | |
16:15:00.104938 SC: 16:15/6 | |
16:15:00.149431 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:00.473310 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:01.189707 T10013966 Write-Data Control setpoint: 57.40 | |
16:15:01.237112 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:15:02.166469 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:02.271102 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:03.327053 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:03.352519 BC0193AE6 Read-Ack Boiler water temperature: 58.90 | |
16:15:04.181195 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:15:04.226873 R80750000 Read-Data CH pump starts: 0 | |
16:15:04.280429 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:15:04.338452 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:15:05.192506 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:05.509658 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:06.197727 T10013966 Write-Data Control setpoint: 57.40 | |
16:15:06.290888 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:15:07.423458 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:07.453034 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:08.214404 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:08.367918 BC0193AE6 Read-Ack Boiler water temperature: 58.90 | |
16:15:09.472114 T00630000 Read-Data Message ID 99: 0 | |
16:15:09.506359 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:15:09.541733 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:15:09.576549 AF0630000 Unk-DataId Message ID 99: 0 | |
16:15:10.229640 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:10.429427 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:11.521178 T90013980 Write-Data Control setpoint: 57.50 | |
16:15:11.548570 B50013980 Write-Ack Control setpoint: 57.50 | |
16:15:12.337849 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:12.348711 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:13.570253 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:13.603397 BC0193AE6 Read-Ack Boiler water temperature: 58.90 | |
16:15:14.385005 T00030000 Read-Data Slave configuration: 00000000 0 | |
16:15:14.403647 B4003410B Read-Ack Slave configuration: 01000001 11 | |
- DHW: present (1) | |
- Control type: modulating (0) | |
- Cooling: not supported (0) | |
- DHW: instantaneous (0) | |
- Master pump control: allowed (0) | |
- CH2: not present (0) | |
- Remote water filling: not available (1) | |
- Heat/cool mode control: heat (0) | |
16:15:15.639321 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:15.876147 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:16.434914 T90013980 Write-Data Control setpoint: 57.50 | |
16:15:16.466293 B50013980 Write-Ack Control setpoint: 57.50 | |
16:15:17.690579 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:17.721658 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:18.298506 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:19.681500 B40193AF3 Read-Ack Boiler water temperature: 58.95 | |
16:15:19.729881 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:15:19.756195 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:15:20.430901 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:20.722147 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:21.318079 T10013999 Write-Data Control setpoint: 57.60 | |
16:15:21.470553 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:15:22.579490 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:22.620082 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:23.332616 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:23.465782 BC0193B00 Read-Ack Boiler water temperature: 59.00 | |
16:15:24.341157 T001B0000 Read-Data Outside temperature: 0.00 | |
16:15:24.367487 R00770000 Read-Data DHW burner starts: 0 | |
16:15:24.463857 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:15:24.488362 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:15:25.350378 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:25.658413 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:26.480680 T10013999 Write-Data Control setpoint: 57.60 | |
16:15:26.506473 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:15:27.462945 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:27.491558 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:28.375521 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:28.464517 BC0193B00 Read-Ack Boiler water temperature: 59.00 | |
16:15:29.381205 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:15:29.474457 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:15:30.389285 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:30.652271 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:31.413131 T900139B3 Write-Data Control setpoint: 57.70 | |
16:15:31.473512 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:15:32.408801 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:32.568505 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:33.642013 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:33.684668 BC0193B00 Read-Ack Boiler water temperature: 59.00 | |
16:15:34.456078 T10101580 Write-Data Room setpoint: 21.50 | |
16:15:34.564521 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:15:35.430750 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:35.745734 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:36.506483 T100139CC Write-Data Control setpoint: 57.80 | |
16:15:36.551401 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:15:37.448703 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:37.564185 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:38.555585 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:38.568478 BC0193B00 Read-Ack Boiler water temperature: 59.00 | |
16:15:39.505501 T10181419 Write-Data Room temperature: 20.10 | |
16:15:39.557574 BD0181419 Write-Ack Room temperature: 20.10 | |
16:15:40.602945 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:40.897363 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:41.823775 T900139E6 Write-Data Control setpoint: 57.90 | |
16:15:41.861959 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:15:42.649235 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:42.677203 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:43.491794 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:43.643182 BC0193B00 Read-Ack Boiler water temperature: 59.00 | |
16:15:44.716375 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:15:44.752816 R00780000 Read-Data Burner operation hours: 0 | |
16:15:44.814447 BC078153E Read-Ack Burner operation hours: 5438 | |
16:15:44.873508 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:15:45.533947 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:45.656860 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:46.766690 T10013999 Write-Data Control setpoint: 57.60 | |
16:15:46.803002 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:15:47.563675 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:47.652736 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:48.796644 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:48.831035 BC0193B1E Read-Ack Boiler water temperature: 59.12 | |
16:15:49.613494 T00630000 Read-Data Message ID 99: 0 | |
16:15:49.643742 R80790000 Read-Data CH pump operation hours: 0 | |
16:15:49.697852 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:15:49.752318 AF0630000 Unk-DataId Message ID 99: 0 | |
16:15:50.768211 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:50.887335 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:51.558362 T90013980 Write-Data Control setpoint: 57.50 | |
16:15:51.651215 B50013980 Write-Ack Control setpoint: 57.50 | |
16:15:52.889824 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:52.920924 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:53.720981 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:53.750725 BC0193B33 Read-Ack Boiler water temperature: 59.20 | |
16:15:54.939730 T00120000 Read-Data CH water pressure: 0.00 | |
16:15:54.988118 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:15:55.060470 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:15:55.111209 AF0120000 Unk-DataId CH water pressure: 0.00 | |
16:15:55.798727 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:15:56.200641 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:15:56.658813 T10013966 Write-Data Control setpoint: 57.40 | |
16:15:56.754083 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:15:57.806356 T00110000 Read-Data Relative modulation level: 0.00 | |
16:15:57.843998 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:15:59.035416 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:15:59.066176 BC0193B33 Read-Ack Boiler water temperature: 59.20 | |
16:15:59.802380 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:15:59.843167 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:16:00.154192 Command: SC=16:16/6 | |
16:16:00.262775 SC: 16:16/6 | |
16:16:00.637297 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:00.844678 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:01.649707 T10013966 Write-Data Control setpoint: 57.40 | |
16:16:01.742937 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:16:02.658477 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:02.763757 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:03.669830 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:03.765388 BC0193B30 Read-Ack Boiler water temperature: 59.19 | |
16:16:04.684438 T001B0000 Read-Data Outside temperature: 0.00 | |
16:16:04.723183 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:16:04.840619 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:16:04.849588 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:16:05.685113 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:05.893278 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:06.696578 T10013966 Write-Data Control setpoint: 57.40 | |
16:16:06.842726 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:16:08.108670 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:08.142528 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:08.908499 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:08.922583 BC0193B33 Read-Ack Boiler water temperature: 59.20 | |
16:16:09.722750 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:16:09.847420 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:16:10.934905 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:11.136513 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:11.748900 T10013966 Write-Data Control setpoint: 57.40 | |
16:16:11.843715 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:16:12.822270 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:12.832143 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:13.778690 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:13.822287 BC0193B33 Read-Ack Boiler water temperature: 59.20 | |
16:16:15.043584 T10101580 Write-Data Room setpoint: 21.50 | |
16:16:15.066882 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:16:15.850790 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:16.204050 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:17.056567 T90013980 Write-Data Control setpoint: 57.50 | |
16:16:17.103373 B50013980 Write-Ack Control setpoint: 57.50 | |
16:16:17.873444 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:17.916578 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:19.104407 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:19.132997 BC0193B33 Read-Ack Boiler water temperature: 59.20 | |
16:16:19.814766 T10181426 Write-Data Room temperature: 20.15 | |
16:16:19.948431 BD0181426 Write-Ack Room temperature: 20.15 | |
16:16:20.826276 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:21.003893 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:21.829927 T10013999 Write-Data Control setpoint: 57.60 | |
16:16:21.959701 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:16:22.836121 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:22.939111 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:24.022688 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:24.054667 BC0193B33 Read-Ack Boiler water temperature: 59.20 | |
16:16:24.860035 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:16:24.907069 R00740000 Read-Data Burner starts: 0 | |
16:16:24.969633 BC074FFFF Read-Ack Burner starts: 65535 | |
16:16:25.072415 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:16:25.862298 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:26.310369 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:26.886251 T10013999 Write-Data Control setpoint: 57.60 | |
16:16:27.018661 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:16:28.115323 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:28.145714 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:28.888943 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:29.019199 B40193B4C Read-Ack Boiler water temperature: 59.30 | |
16:16:29.890734 T00630000 Read-Data Message ID 99: 0 | |
16:16:29.938154 R80750000 Read-Data CH pump starts: 0 | |
16:16:30.025317 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:16:30.043218 AF0630000 Unk-DataId Message ID 99: 0 | |
16:16:30.940918 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:31.291682 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:32.214663 T900139B3 Write-Data Control setpoint: 57.70 | |
16:16:32.249840 B500139B3 Write-Ack Control setpoint: 57.70 | |
16:16:33.058365 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:33.088303 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:33.919601 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:34.019522 B40193B4C Read-Ack Boiler water temperature: 59.30 | |
16:16:35.073844 T801A0000 Read-Data DHW temperature: 0.00 | |
16:16:35.099594 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:16:35.143794 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:16:35.173797 A701A0000 Unk-DataId DHW temperature: 0.00 | |
16:16:35.932194 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:36.328192 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:37.098852 T100139CC Write-Data Control setpoint: 57.80 | |
16:16:37.123691 BD00139CC Write-Ack Control setpoint: 57.80 | |
16:16:38.017365 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:38.048561 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:39.174264 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:39.200874 B40193B4C Read-Ack Boiler water temperature: 59.30 | |
16:16:39.993054 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:16:40.120832 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:16:41.221547 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:41.489261 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:42.041217 T900139E6 Write-Data Control setpoint: 57.90 | |
16:16:42.130837 B500139E6 Write-Ack Control setpoint: 57.90 | |
16:16:42.995338 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:43.121130 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:44.090115 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:44.123310 B40193B4C Read-Ack Boiler water temperature: 59.30 | |
16:16:44.999138 T001B0000 Read-Data Outside temperature: 0.00 | |
16:16:45.034475 R00770000 Read-Data DHW burner starts: 0 | |
16:16:45.125109 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:16:45.146653 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:16:46.138452 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:46.475068 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:47.013175 T90013980 Write-Data Control setpoint: 57.50 | |
16:16:47.122553 B50013980 Write-Ack Control setpoint: 57.50 | |
16:16:48.019826 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:48.122145 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:49.026747 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:49.126169 B40193B4C Read-Ack Boiler water temperature: 59.30 | |
16:16:50.123256 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:16:50.168680 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:16:51.053632 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:51.442641 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:52.694048 T10013966 Write-Data Control setpoint: 57.40 | |
16:16:52.717683 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:16:53.101213 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:53.202280 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:54.062278 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:54.205398 B40193B4C Read-Ack Boiler water temperature: 59.30 | |
16:16:55.127187 T10101580 Write-Data Room setpoint: 21.50 | |
16:16:55.175913 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:16:56.377693 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:16:56.727225 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:16:57.196810 T9001394C Write-Data Control setpoint: 57.30 | |
16:16:57.217499 B5001394C Write-Ack Control setpoint: 57.30 | |
16:16:58.447252 T00110000 Read-Data Relative modulation level: 0.00 | |
16:16:58.471149 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:16:59.246070 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:16:59.266011 B40193B4C Read-Ack Boiler water temperature: 59.30 | |
16:17:00.007705 Command: SC=16:17/6 | |
16:17:00.107129 T90181435 Write-Data Room temperature: 20.21 | |
16:17:00.124724 SC: 16:17/6 | |
16:17:00.203459 B50181435 Write-Ack Room temperature: 20.21 | |
16:17:01.110018 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:01.210833 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:02.137874 T10013933 Write-Data Control setpoint: 57.20 | |
16:17:02.183907 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:17:03.343002 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:03.365387 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:04.162790 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:04.226244 B40193B54 Read-Ack Boiler water temperature: 59.33 | |
16:17:05.144476 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:17:05.170457 R00780000 Read-Data Burner operation hours: 0 | |
16:17:05.306144 BC078153E Read-Ack Burner operation hours: 5438 | |
16:17:05.340852 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:17:06.208678 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:06.567944 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:07.418330 T10013933 Write-Data Control setpoint: 57.20 | |
16:17:07.440559 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:17:08.172015 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:08.304465 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:09.486243 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:09.514194 BC0193B66 Read-Ack Boiler water temperature: 59.40 | |
16:17:10.174680 T00630000 Read-Data Message ID 99: 0 | |
16:17:10.207207 R80790000 Read-Data CH pump operation hours: 0 | |
16:17:10.306327 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:17:10.341886 AF0630000 Unk-DataId Message ID 99: 0 | |
16:17:11.733733 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:12.061888 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:12.380450 T10013933 Write-Data Control setpoint: 57.20 | |
16:17:12.413297 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:17:13.526548 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:13.554162 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:14.206398 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:14.298649 BC0193B66 Read-Ack Boiler water temperature: 59.40 | |
16:17:15.207757 T001D0000 Read-Data Solar storage temperature: 0.00 | |
16:17:15.234917 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:17:15.303090 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:17:15.324732 AF01D0000 Unk-DataId Solar storage temperature: 0.00 | |
16:17:16.448514 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:16.805914 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:17.267282 T9001394C Write-Data Control setpoint: 57.30 | |
16:17:17.311423 B5001394C Write-Ack Control setpoint: 57.30 | |
16:17:18.496934 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:18.522409 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:19.315270 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:19.404951 BC0193B66 Read-Ack Boiler water temperature: 59.40 | |
16:17:20.242504 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:17:20.402104 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:17:21.367272 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:21.619028 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:22.534503 T10013966 Write-Data Control setpoint: 57.40 | |
16:17:22.561642 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:17:23.411606 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:23.433775 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:24.645984 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:24.674191 BC0193B66 Read-Ack Boiler water temperature: 59.40 | |
16:17:25.279255 T001B0000 Read-Data Outside temperature: 0.00 | |
16:17:25.303855 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:17:25.396571 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:17:25.419801 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:17:26.322229 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:26.589331 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:27.289891 T10013966 Write-Data Control setpoint: 57.40 | |
16:17:27.399676 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:17:28.327560 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:28.374388 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:29.305805 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:29.396771 BC0193B66 Read-Ack Boiler water temperature: 59.40 | |
16:17:30.310681 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:17:30.403350 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:17:31.607686 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:31.927855 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:32.403189 T90013980 Write-Data Control setpoint: 57.50 | |
16:17:32.424712 B50013980 Write-Ack Control setpoint: 57.50 | |
16:17:33.331207 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:33.496911 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:34.337716 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:34.499296 B40193B80 Read-Ack Boiler water temperature: 59.50 | |
16:17:35.345237 T10101580 Write-Data Room setpoint: 21.50 | |
16:17:35.499240 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:17:36.350713 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:36.497599 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:37.361181 T10013999 Write-Data Control setpoint: 57.60 | |
16:17:37.498208 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:17:38.567588 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:38.590424 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:39.374764 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:39.476729 B40193B80 Read-Ack Boiler water temperature: 59.50 | |
16:17:40.381778 T90181435 Write-Data Room temperature: 20.21 | |
16:17:40.482411 B50181435 Write-Ack Room temperature: 20.21 | |
16:17:41.391390 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:41.719283 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:42.393603 T10013999 Write-Data Control setpoint: 57.60 | |
16:17:42.487416 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:17:43.484328 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:43.517711 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:44.406296 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:44.500041 B40193B80 Read-Ack Boiler water temperature: 59.50 | |
16:17:45.414465 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:17:45.449913 R00740000 Read-Data Burner starts: 0 | |
16:17:45.578055 BC074FFFF Read-Ack Burner starts: 65535 | |
16:17:45.613628 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:17:46.758940 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:47.083479 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:47.428146 T10013966 Write-Data Control setpoint: 57.40 | |
16:17:47.579260 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:17:48.811669 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:48.840790 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:49.637318 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:49.669934 B40193B80 Read-Ack Boiler water temperature: 59.50 | |
16:17:50.776782 T00630000 Read-Data Message ID 99: 0 | |
16:17:50.804402 R80750000 Read-Data CH pump starts: 0 | |
16:17:50.852129 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:17:50.900734 AF0630000 Unk-DataId Message ID 99: 0 | |
16:17:51.674198 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:52.005252 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:52.493020 T10013933 Write-Data Control setpoint: 57.20 | |
16:17:52.585137 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:17:53.472723 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:53.580841 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:54.543723 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:54.573125 B40193B80 Read-Ack Boiler water temperature: 59.50 | |
16:17:55.773939 T00300000 Read-Data DHW setpoint boundaries: 0 0 | |
16:17:55.802412 BC0303C28 Read-Ack DHW setpoint boundaries: 60 40 | |
16:17:56.590566 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:17:56.925704 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:17:57.819081 T10013933 Write-Data Control setpoint: 57.20 | |
16:17:57.841179 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:17:58.625720 T00110000 Read-Data Relative modulation level: 0.00 | |
16:17:58.653501 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:17:59.869001 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:17:59.899020 B40193B80 Read-Ack Boiler water temperature: 59.50 | |
16:18:00.006644 Command: SC=16:18/6 | |
16:18:00.125639 SC: 16:18/6 | |
16:18:00.687338 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:18:00.696426 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:18:01.915049 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:02.273931 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:02.735232 T90013919 Write-Data Control setpoint: 57.10 | |
16:18:02.769212 B50013919 Write-Ack Control setpoint: 57.10 | |
16:18:03.556960 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:03.677796 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:04.783416 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:04.819782 B40193B80 Read-Ack Boiler water temperature: 59.50 | |
16:18:05.612059 T001B0000 Read-Data Outside temperature: 0.00 | |
16:18:05.631401 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:18:05.662633 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:18:05.708294 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:18:06.565935 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:06.840162 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:07.573540 T90013919 Write-Data Control setpoint: 57.10 | |
16:18:07.677573 B50013919 Write-Ack Control setpoint: 57.10 | |
16:18:08.878946 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:08.975043 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:09.697195 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:09.738159 B40193B80 Read-Ack Boiler water temperature: 59.50 | |
16:18:10.927913 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:18:10.963742 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:18:11.745045 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:12.131446 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:12.619587 T10013933 Write-Data Control setpoint: 57.20 | |
16:18:12.760572 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:18:13.624722 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:13.758654 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:14.634852 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:14.759213 BC0193B99 Read-Ack Boiler water temperature: 59.60 | |
16:18:15.846522 T10101580 Write-Data Room setpoint: 21.50 | |
16:18:15.873000 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:18:16.661447 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:16.936246 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:17.656741 T10013933 Write-Data Control setpoint: 57.20 | |
16:18:17.761752 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:18:18.708345 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:18.770819 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:19.672635 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:19.766162 BC0193B99 Read-Ack Boiler water temperature: 59.60 | |
16:18:20.757742 T90181442 Write-Data Room temperature: 20.26 | |
16:18:20.790586 B50181442 Write-Ack Room temperature: 20.26 | |
16:18:21.990624 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:22.389597 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:22.804992 T9001394C Write-Data Control setpoint: 57.30 | |
16:18:22.867565 B5001394C Write-Ack Control setpoint: 57.30 | |
16:18:23.704290 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:23.862867 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:24.715699 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:24.872072 BC0193B99 Read-Ack Boiler water temperature: 59.60 | |
16:18:25.717103 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:18:25.745631 R00770000 Read-Data DHW burner starts: 0 | |
16:18:25.865077 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:18:25.892570 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:18:26.727228 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:27.091845 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:27.737563 T10013966 Write-Data Control setpoint: 57.40 | |
16:18:27.864518 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:18:28.743753 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:28.867836 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:29.748853 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:29.864496 BC0193B99 Read-Ack Boiler water temperature: 59.60 | |
16:18:30.997114 T00630000 Read-Data Message ID 99: 0 | |
16:18:31.023317 R00780000 Read-Data Burner operation hours: 0 | |
16:18:31.065255 BC078153E Read-Ack Burner operation hours: 5438 | |
16:18:31.105619 AF0630000 Unk-DataId Message ID 99: 0 | |
16:18:31.762344 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:32.118253 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:32.769158 T10013966 Write-Data Control setpoint: 57.40 | |
16:18:32.863599 BD0013966 Write-Ack Control setpoint: 57.40 | |
16:18:33.866002 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:33.891226 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:35.093694 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:35.114630 BC0193B99 Read-Ack Boiler water temperature: 59.60 | |
16:18:35.912357 T80310000 Read-Data Max CH setpoint boundaries: 0 0 | |
16:18:35.944922 B40314B14 Read-Ack Max CH setpoint boundaries: 75 20 | |
16:18:37.141647 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:37.438321 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:37.961232 T90013980 Write-Data Control setpoint: 57.50 | |
16:18:37.987059 B50013980 Write-Ack Control setpoint: 57.50 | |
16:18:39.029843 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:39.055596 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:40.019678 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:40.045259 BC0193B99 Read-Ack Boiler water temperature: 59.60 | |
16:18:40.953066 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:18:40.983423 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:18:42.056636 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:42.379281 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:42.859988 T10013999 Write-Data Control setpoint: 57.60 | |
16:18:42.955433 BD0013999 Write-Ack Control setpoint: 57.60 | |
16:18:43.854491 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:43.950307 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:44.946988 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:44.972843 BC0193B99 Read-Ack Boiler water temperature: 59.60 | |
16:18:46.176246 T001B0000 Read-Data Outside temperature: 0.00 | |
16:18:46.212712 R80790000 Read-Data CH pump operation hours: 0 | |
16:18:46.272087 B40791AF4 Read-Ack CH pump operation hours: 6900 | |
16:18:46.328778 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:18:46.971114 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:47.258484 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:47.882612 T10013933 Write-Data Control setpoint: 57.20 | |
16:18:48.051261 BD0013933 Write-Ack Control setpoint: 57.20 | |
16:18:49.023804 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:49.046075 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:50.249813 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:50.274570 BC0193B99 Read-Ack Boiler water temperature: 59.60 | |
16:18:51.067346 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:18:51.090769 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:18:52.297321 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:52.651549 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:53.115472 T100138E6 Write-Data Control setpoint: 56.90 | |
16:18:53.141716 BD00138E6 Write-Ack Control setpoint: 56.90 | |
16:18:53.934176 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:54.054742 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:18:55.164129 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:18:55.184749 B40193BB3 Read-Ack Boiler water temperature: 59.70 | |
16:18:55.952662 T10101580 Write-Data Room setpoint: 21.50 | |
16:18:56.047880 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:18:57.211875 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:18:57.381454 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:18:58.054301 T900138CC Write-Data Control setpoint: 56.80 | |
16:18:58.078982 B500138CC Write-Ack Control setpoint: 56.80 | |
16:18:59.282873 T00110000 Read-Data Relative modulation level: 0.00 | |
16:18:59.304649 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:00.012671 Command: SC=16:19/6 | |
16:19:00.063514 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:00.079205 B40193BB3 Read-Ack Boiler water temperature: 59.70 | |
16:19:01.308281 T10181454 Write-Data Room temperature: 20.33 | |
16:19:01.356239 BD0181454 Write-Ack Room temperature: 20.33 | |
16:19:02.128135 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:02.423852 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:02.982624 T100138B3 Write-Data Control setpoint: 56.70 | |
16:19:03.152986 BD00138B3 Write-Ack Control setpoint: 56.70 | |
16:19:04.175123 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:04.211521 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:05.286217 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:05.314082 B40193BB3 Read-Ack Boiler water temperature: 59.70 | |
16:19:06.183942 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:19:06.221641 R807A0000 Read-Data DHW pump/valve operation hours: 0 | |
16:19:06.258067 BC07A0242 Read-Ack DHW pump/valve operation hours: 578 | |
16:19:06.278956 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:19:07.010415 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:07.250593 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:08.274245 T100138B3 Write-Data Control setpoint: 56.70 | |
16:19:08.305907 BD00138B3 Write-Ack Control setpoint: 56.70 | |
16:19:09.024262 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:09.126490 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:10.279778 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:10.308303 B40193BB3 Read-Ack Boiler water temperature: 59.70 | |
16:19:11.162906 T00630000 Read-Data Message ID 99: 0 | |
16:19:11.186108 R007B0000 Read-Data DHW burner operation hours: 0 | |
16:19:11.228201 B407B0296 Read-Ack DHW burner operation hours: 662 | |
16:19:11.264966 AF0630000 Unk-DataId Message ID 99: 0 | |
16:19:12.045164 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:12.372040 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:13.187655 T100138B3 Write-Data Control setpoint: 56.70 | |
16:19:13.208505 BD00138B3 Write-Ack Control setpoint: 56.70 | |
16:19:14.416307 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:14.440877 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:15.234080 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:15.269724 B40193BB3 Read-Ack Boiler water temperature: 59.70 | |
16:19:16.075929 T10382800 Write-Data DHW setpoint: 40.00 | |
16:19:16.225981 BD0382800 Write-Ack DHW setpoint: 40.00 | |
16:19:17.281698 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:17.428340 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:18.100284 T900138CC Write-Data Control setpoint: 56.80 | |
16:19:18.224867 B500138CC Write-Ack Control setpoint: 56.80 | |
16:19:19.104325 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:19.231448 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:20.149629 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:20.203788 B40193BB3 Read-Ack Boiler water temperature: 59.70 | |
16:19:21.114711 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:19:21.231417 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:19:22.196672 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:22.295788 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:23.177411 T900138CC Write-Data Control setpoint: 56.80 | |
16:19:23.221199 B500138CC Write-Ack Control setpoint: 56.80 | |
16:19:24.274000 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:24.308139 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:25.152035 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:25.240027 B40193BBA Read-Ack Boiler water temperature: 59.73 | |
16:19:26.155547 T001B0000 Read-Data Outside temperature: 0.00 | |
16:19:26.185706 R00740000 Read-Data Burner starts: 0 | |
16:19:26.254027 BC074FFFF Read-Ack Burner starts: 65535 | |
16:19:26.281344 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:19:27.161470 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:27.462798 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:28.170011 T100138E6 Write-Data Control setpoint: 56.90 | |
16:19:28.327754 BD00138E6 Write-Ack Control setpoint: 56.90 | |
16:19:29.571545 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:29.598844 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:30.183684 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:30.328285 BC0193BCC Read-Ack Boiler water temperature: 59.80 | |
16:19:31.209868 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:19:31.332157 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:19:32.202035 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:32.562844 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:33.259145 T100138E6 Write-Data Control setpoint: 56.90 | |
16:19:33.308253 BD00138E6 Write-Ack Control setpoint: 56.90 | |
16:19:34.503939 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:34.539339 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:35.226082 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:35.329260 BC0193BCC Read-Ack Boiler water temperature: 59.80 | |
16:19:36.236283 T10101580 Write-Data Room setpoint: 21.50 | |
16:19:36.329184 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:19:37.336550 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:37.436913 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:38.243771 T10013900 Write-Data Control setpoint: 57.00 | |
16:19:38.410094 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:19:39.258247 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:39.423234 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:40.312017 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:40.412958 BC0193BCC Read-Ack Boiler water temperature: 59.80 | |
16:19:41.467571 T10181454 Write-Data Room temperature: 20.33 | |
16:19:41.494750 BD0181454 Write-Ack Room temperature: 20.33 | |
16:19:42.679493 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:43.061717 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:43.497097 T10013900 Write-Data Control setpoint: 57.00 | |
16:19:43.526124 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:19:44.316408 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:44.411485 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:45.300409 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:45.426515 BC0193BCC Read-Ack Boiler water temperature: 59.80 | |
16:19:46.366237 T00090000 Read-Data Remote override room setpoint: 0.00 | |
16:19:46.396380 R80750000 Read-Data CH pump starts: 0 | |
16:19:46.446015 B4075FFFF Read-Ack CH pump starts: 65535 | |
16:19:46.492841 AC0091580 Read-Ack Remote override room setpoint: 21.50 | |
16:19:47.315176 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:47.783604 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:48.329191 T100138E6 Write-Data Control setpoint: 56.90 | |
16:19:48.423813 BD00138E6 Write-Ack Control setpoint: 56.90 | |
16:19:49.333560 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:49.424012 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:50.363891 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:50.408371 BC0193BCC Read-Ack Boiler water temperature: 59.80 | |
16:19:51.690019 T00630000 Read-Data Message ID 99: 0 | |
16:19:51.733417 R80760000 Read-Data DHW pump/valve starts: 0 | |
16:19:51.767470 B40769A90 Read-Ack DHW pump/valve starts: 39568 | |
16:19:51.801815 AF0630000 Unk-DataId Message ID 99: 0 | |
16:19:52.372919 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:52.537032 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:53.491064 T100138E6 Write-Data Control setpoint: 56.90 | |
16:19:53.518909 BD00138E6 Write-Ack Control setpoint: 56.90 | |
16:19:54.373618 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:54.515215 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:19:55.412292 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:19:55.511626 BC0193BE1 Read-Ack Boiler water temperature: 59.88 | |
16:19:56.385879 T90395A00 Write-Data Max CH water setpoint: 90.00 | |
16:19:56.519275 B60394B00 Data-Inv Max CH water setpoint: 75.00 | |
16:19:57.393420 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:19:57.683412 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:19:58.651833 T900138CC Write-Data Control setpoint: 56.80 | |
16:19:58.671391 B500138CC Write-Ack Control setpoint: 56.80 | |
16:19:59.481234 T00110000 Read-Data Relative modulation level: 0.00 | |
16:19:59.525124 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:20:00.035467 Command: SC=16:20/6 | |
16:20:00.140456 SC: 16:20/6 | |
16:20:00.420211 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:20:00.515412 BC0193BF3 Read-Ack Boiler water temperature: 59.95 | |
16:20:01.433173 T00050000 Read-Data Application-specific flags: 00000000 0 | |
16:20:01.522818 BC00500FF Read-Ack Application-specific flags: 00000000 255 | |
- Service request: no (0) | |
- Lockout-reset: disabled (0) | |
- Low water pressure: no fault (0) | |
- Gas/flame fault: no fault (0) | |
- Air pressure fault: no fault (0) | |
- Water over-temperature: no fault (0) | |
16:20:02.435970 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:20:02.564276 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:20:03.449188 T900138CC Write-Data Control setpoint: 56.80 | |
16:20:03.612625 B500138CC Write-Ack Control setpoint: 56.80 | |
16:20:04.454082 T00110000 Read-Data Relative modulation level: 0.00 | |
16:20:04.614727 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:20:05.464864 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:20:05.616220 B40193BFD Read-Ack Boiler water temperature: 59.99 | |
16:20:06.474033 T001B0000 Read-Data Outside temperature: 0.00 | |
16:20:06.507299 R00770000 Read-Data DHW burner starts: 0 | |
16:20:06.595034 BC077DA98 Read-Ack DHW burner starts: 55960 | |
16:20:06.627456 AF01B0000 Unk-DataId Outside temperature: 0.00 | |
16:20:07.490031 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:20:07.775375 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:20:08.563013 T100138E6 Write-Data Control setpoint: 56.90 | |
16:20:08.586909 BD00138E6 Write-Ack Control setpoint: 56.90 | |
16:20:09.498601 T00110000 Read-Data Relative modulation level: 0.00 | |
16:20:09.593664 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:20:10.508365 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:20:10.597470 B40193C00 Read-Ack Boiler water temperature: 60.00 | |
16:20:11.761290 T900E6400 Write-Data Maximum relative modulation level: 100.00 | |
16:20:11.789890 B500E6400 Write-Ack Maximum relative modulation level: 100.00 | |
16:20:12.580379 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:20:12.947264 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:20:13.808855 T100138E6 Write-Data Control setpoint: 56.90 | |
16:20:13.833826 BD00138E6 Write-Ack Control setpoint: 56.90 | |
16:20:14.627330 T00110000 Read-Data Relative modulation level: 0.00 | |
16:20:14.684064 BC0110000 Read-Ack Relative modulation level: 0.00 | |
16:20:15.543297 T80190000 Read-Data Boiler water temperature: 0.00 | |
16:20:15.694263 B40193C00 Read-Ack Boiler water temperature: 60.00 | |
16:20:16.684197 T10101580 Write-Data Room setpoint: 21.50 | |
16:20:16.694393 BD0101580 Write-Ack Room setpoint: 21.50 | |
16:20:17.833619 T00000300 Read-Data Status: 00000011 00000000 | |
- CH enable: enabled (1) | |
- DHW enable: enabled (1) | |
- Cooling enable: disabled (0) | |
- OTC active: not active (0) | |
- CH2 enable: disabled (0) | |
- Summer/winter mode: winter (0) | |
- DHW blocking: unblocked (0) | |
16:20:17.949124 BC000030A Read-Ack Status: 00000011 00001010 | |
- Fault indication: no fault (0) | |
- CH mode: active (1) | |
- DHW mode: not active (0) | |
- Flame status: flame on (1) | |
- Cooling status: not active (0) | |
- CH2 mode: not active (0) | |
- Diagnostic indication: no diagnostics (0) | |
- Electricity production: not active (0) | |
16:20:18.723994 T10013900 Write-Data Control setpoint: 57.00 | |
16:20:18.751079 BD0013900 Write-Ack Control setpoint: 57.00 | |
16:20:19.970857 T00110000 Read-Data Relative modulation level: 0.00 | |
16:20:20.005788 BC0110000 Read-Ack Relative modulation level: 0.00 |