blueprint: | |
name: Auto Fan Temperature Control for 3-Speed Fan | |
author: WillCodeForCats | |
description: | |
"This sets the fan speed for a 3-speed fan based on aroom temperature | |
sensor entity. Any fan entity with 3 speeds will work with this blueprint. | |
There are action selectors for both the cycle loop and the shutdown loop for adding | |
control of heating / cooling sources, or anything else you want Home Assistant | |
to do. | |
Based on [SirGoodenough/HA_Blueprints](https://github.com/SirGoodenough/HA_Blueprints/) | |
with time-based stuff removed." | |
source_url: https://gist.github.com/WillCodeForCats/5c7dc1bb2da594d40e7791372e8dfcb6 | |
domain: automation | |
homeassistant: | |
min_version: 2023.3.0 | |
input: | |
fan: | |
name: Fan Entity | |
description: The Home Assistant Fan entity to control. | |
selector: | |
entity: | |
domain: | |
- fan | |
multiple: false | |
room_temp_now: | |
name: Room Temperature Sensor | |
description: | |
This is a temperature sensor or averaged sensor, within the same | |
room as the fan or within the fan airflow. | |
selector: | |
entity: | |
domain: | |
- sensor | |
multiple: false | |
fan_control: | |
name: Toggle to turn the auto fan function off for when away or seasonally | |
description: | |
"```input_boolean``` - If this is set to off, the Automation will | |
be disabled. | |
This Helper has to be set up in [![Open your Home Assistant instance and show | |
your helper entities.](https://my.home-assistant.io/badges/helpers.svg)](https://my.home-assistant.io/redirect/helpers/) " | |
selector: | |
entity: | |
domain: | |
- input_boolean | |
multiple: false | |
room_set_temp: | |
name: Room Target Temperature | |
description: | |
"```input_number``` - This is the target temperature of the room. | |
Use the same scale as the temperature sensor. | |
This Helper has to be set up in [![Open your Home Assistant instance and show | |
your helper entities.](https://my.home-assistant.io/badges/helpers.svg)](https://my.home-assistant.io/redirect/helpers/) " | |
selector: | |
entity: | |
domain: | |
- input_number | |
multiple: false | |
temp_gap: | |
name: Temp Hysteresis | |
description: "This keeps the fan from speed cycling too often. | |
Set it larger if the fan goes on and off too much. | |
Set it smaller if the fan doesn't change speeds fast enough." | |
default: 1.3 | |
selector: | |
number: | |
min: 0.0 | |
max: 7.0 | |
unit_of_measurement: Degrees | |
mode: slider | |
step: 0.1 | |
temp_gap_1_to_2: | |
name: Temp Gap between Low and Medium | |
description: "This is the temp swing between Low and Medium. | |
If the sensor reads between the base temperature and this number of degrees | |
warmer, the fan is on LOW. | |
Below the base temperature the fan is off." | |
default: 4.5 | |
selector: | |
number: | |
min: 1.0 | |
max: 20.0 | |
unit_of_measurement: Degrees | |
mode: slider | |
step: 0.1 | |
temp_gap_2_to_3: | |
name: Temp Gap between Medium and High | |
description: "This is the temp change between Medium and High. | |
If the sensor reads between the base temperature plus the 1 to 2 temperature | |
and this number of degrees warmer, the fan is on MEDIUM. | |
Any warmer than this and the fan is set to HIGH." | |
default: 2.0 | |
selector: | |
number: | |
min: 1.0 | |
max: 20.0 | |
unit_of_measurement: Degrees | |
mode: slider | |
step: 0.1 | |
loop_action: | |
name: User action for fan enabled condition (loop) | |
description: | |
This can be used to start an A/C unit or other device to turn on. | |
It is executed when the fan turns on or changes speeds. Leave this empty to | |
do nothing extra. | |
default: [] | |
selector: | |
action: {} | |
off_action: | |
name: User action for fan off condition (off_action) | |
description: | |
This is can be used to disable an A/C unit or other device to turn | |
off. It is executed when the fan turns off. Leave this empty to do nothing | |
extra. | |
default: [] | |
selector: | |
action: {} | |
variables: | |
temp_gap_var: !input temp_gap | |
temp_gap_val: "{{ temp_gap_var | float(1.3) }}" | |
temp_gap_1_to_2_var: !input temp_gap_1_to_2 | |
temp_gap_1_to_2_val: "{{ temp_gap_1_to_2_var | float(4.5) }}" | |
temp_gap_2_to_3_var: !input temp_gap_2_to_3 | |
temp_gap_2_to_3_val: "{{ temp_gap_2_to_3_var | float(2.0) }}" | |
room_set_temp_var: !input room_set_temp | |
room_set_temp_val: | |
"{{ expand(room_set_temp_var)[0].state | float(73.1) - temp_gap_val | |
}}" | |
room_temp_now_var: !input room_temp_now | |
room_temp_now_val: | |
"{{ expand(room_temp_now_var)[0].state | float(room_set_temp_val) | |
}}" | |
my_loop_action: !input loop_action | |
my_off_action: !input off_action | |
mode: restart | |
trigger: | |
- platform: state | |
id: go_if_the_control_is_switched_off | |
entity_id: !input fan_control | |
to: "off" | |
- platform: state | |
id: go_on_any_sensor_temp_changes | |
entity_id: !input room_temp_now | |
- platform: state | |
id: go_on_any_set_temp_changes | |
entity_id: !input room_set_temp | |
- platform: state | |
id: go_if_the_control_is_switched_on | |
entity_id: !input fan_control | |
to: "on" | |
action: | |
- choose: | |
- alias: Fan normal turn off sequence | |
conditions: | |
or: | |
- alias: The automation has been disabled | |
condition: trigger | |
id: go_if_the_control_is_switched_off | |
sequence: | |
- alias: Do something when the fan stop condition triggers | |
if: "{{ not my_off_action in ('none', 'null', 'unavailable', '') }}" | |
then: !input off_action | |
- alias: Stop the fan | |
service: fan.turn_off | |
target: | |
entity_id: !input fan | |
- alias: Normal fan run sequence | |
conditions: | |
and: | |
- alias: Make sure the Fan is enabled | |
condition: state | |
entity_id: !input fan_control | |
state: "on" | |
sequence: | |
- alias: Do something on every fan set speed condition trigger | |
if: "{{ not my_loop_action in ('none', 'null', 'unavailable', '') }}" | |
then: !input loop_action | |
- alias: Set the fan speed based on the sensor temperature | |
service: fan.set_percentage | |
target: | |
entity_id: !input fan | |
data: | |
percentage: | |
"{% if room_temp_now_val < room_set_temp_val %} 0 {% elif room_temp_now_val | |
< (room_set_temp_val + temp_gap_1_to_2_val) %} 33 {% elif room_temp_now_val | |
< (room_set_temp_val + temp_gap_1_to_2_val + temp_gap_2_to_3_val) %} 67 | |
{% else %} 100 {% endif %}" |