var mode = "Stop" | |
var encoder1 = 0 | |
var encoder2 = 0 | |
var step = 0 | |
var down = true | |
var interval_id = null | |
function main(){ | |
mode = "Stop" | |
encoder1 = 0 | |
encoder2 = 0 | |
interval_id = setInterval(bajada, 4000) //Bajar cada 4 segundos | |
} | |
function bajada(){ | |
if(mode === "Stop"){ | |
down = false | |
encoder1 += 1 | |
mode = "Down" | |
console.log("Down") | |
console.log(encoder1, encoder2) | |
} | |
else if(mode === "Down"){ | |
if(encoder1 === 10 && encoder2 === 10){ | |
down = true | |
mode = "Up" | |
console.log("Got all the way down") | |
clearInterval(interval_id) | |
subida() | |
return | |
} | |
if(encoder1 < 10) encoder1++ | |
if(encoder2 < 10) encoder2++ | |
console.log(encoder1, encoder2) | |
} | |
} | |
function subida(){ | |
setTimeout(main, 10000) // Esperar 10 segundos para subir | |
} | |
main() | |
var ModbusRTU = require("modbus-serial"); | |
var vector = { | |
getInputRegister: function(addr, unitID) { | |
return addr; | |
}, | |
getHoldingRegister: function(addr, unitID) { | |
if(addr === 1000) | |
return encoder1 * 1024 | |
else if(addr === 1004) | |
return encoder2 * 1024 | |
else | |
return addr + 8000; | |
}, | |
getCoil: function(addr, unitID) { | |
if(addr == 0) | |
return down | |
else | |
return (addr % 2) === 0; | |
}, | |
setRegister: function(addr, value, unitID) { | |
console.log("set register", addr, value, unitID); return; | |
}, | |
setCoil: function(addr, value, unitID) { | |
console.log("set coil", addr, value, unitID); return; | |
} | |
}; | |
// set the server to answer for modbus requests | |
console.log("ModbusTCP listening on modbus://0.0.0.0:8502"); | |
var serverTCP = new ModbusRTU.ServerTCP(vector, { host: "0.0.0.0", port: 8502, debug: true, unitID: 1 }); |