Test Plan for physical cable


Materials Needed

  • Tape measure
  • Bucket
  • Salt
  • Silicon Conformal Coating or glue gun
  • Strong magent
  • iron weight

1. For physical routing cable

The test bench will consist of 2 setups. One vertical and the other longer and horizontal.

The horizontal setup will be a straight segment of pipe at least 10 meters in length followed by a single bent segment of pipe with a radius of .5m.

The vertical setup will just be a short 1 meter segment of pipe.

  • Test case 1
    • Check whether it is possible to route bare cable without any sensors through the pipe.
    • Cable must be able to slide through a straight segment of pipe at least 10 meters in length followed by a single bent segment of pipe with a radius of .5m
    • Record pass/fail and how easy it was to pass the cable through the pipe.
  • Test case 2:
    • Repeat above test with cable + sensors
    • Record pass/fail and how easy it was to pass the cable through the pipe.
  • Test case 3:
    • Set up a vertical section of pipe (1 meter long) and see if with just gravity alone the cable could slide down the pipe.
    • Record pass/fail and how easy it was to pass the cable through the pipe.
  • Test case 4:
    • Repeat the above tests but the cables tip will have a piece of magnetic iron attached and an external magnet will be used to guide the cable through the pipe
    • Record pass/fail and how easy it was to pass the cable through the pipe.

2. For isolating sensors:

  • Test case:
    • Might need humidity sensor for this test before pouring conformal coasting materials into the empty spaces

3. For salt bath:

The test bench will consist of a plastic 10L bucket filled with a salt water solution of 5% concentration in accordance to ASTM B895 for testing corrosion resistance of stainless steel.

Observing the changing on the surface of sensor cable

Might need to have a RPi connected to it recording data as a way to monitor if there is any catastrophic failure.

  • Test case 1:
    • Check the cable material is able to use in salt water without any changing for two weeks.
    • Is there any rust spot on cable?
    • Check if the sensor still work when connected to the RPi
    • Pass/Fail and record any observed physical changes.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment