(Improved) ZHA - IKEA Symfonisk sound controller for lights
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
blueprint: | |
name: ZHA - IKEA Symfonisk sound controller for lights | |
description: 'Control lights with an IKEA Symfonisk sound controller (the spinny | |
ones). | |
You can set functions for single press, double press and triple press. This allows | |
you to assign, e.g., a scene or anything else. | |
Rotating left/right will change the brightness smoothly of the selected light.' | |
domain: automation | |
input: | |
remote: | |
name: Remote | |
description: IKEA Symfonisk controller to use | |
selector: | |
device: | |
integration: zha | |
manufacturer: IKEA of Sweden | |
model: SYMFONISK Sound Controller | |
multiple: false | |
light: | |
name: Light(s) | |
description: The light(s) to control | |
selector: | |
target: | |
entity: | |
domain: light | |
brightness_step: | |
name: Brightness step | |
description: The value of the brighness step when spinning | |
default: 10 | |
selector: | |
number: | |
min: 1 | |
max: 100 | |
mode: slider | |
step: 1 | |
single_press: | |
name: Single press | |
description: Action to run on single press | |
default: [] | |
selector: | |
action: {} | |
double_press: | |
name: Double press | |
description: Action to run on double press | |
default: [] | |
selector: | |
action: {} | |
triple_press: | |
name: Triple press | |
description: Action to run on triple press | |
default: [] | |
selector: | |
action: {} | |
source_url: https://gist.github.com/seamus65/0cd586edfee2e245e0b7e8081c5865f1 | |
mode: restart | |
max_exceeded: silent | |
trigger: | |
- platform: event | |
event_type: zha_event | |
event_data: | |
device_id: !input remote | |
action: | |
- variables: | |
command: '{{ trigger.event.data.command }}' | |
cluster_id: '{{ trigger.event.data.cluster_id }}' | |
endpoint_id: '{{ trigger.event.data.endpoint_id }}' | |
args: '{{ trigger.event.data.args }}' | |
move_mode: "{{ trigger.event.data.params.move_mode }}" | |
step_size: "{{ trigger.event.data.params.step_size }}" | |
step_mode: "{{ trigger.event.data.params.step_mode }}" | |
br_step: !input brightness_step | |
- choose: | |
- conditions: | |
- '{{ command == ''toggle'' }}' | |
sequence: !input "single_press" | |
- conditions: | |
- "{{ command == 'step' and step_size == 1 and step_mode == 'StepMode.Up' }}" | |
sequence: !input "double_press" | |
- conditions: | |
- "{{ command == 'step' and step_size == 1 and step_mode == 'StepMode.Down' }}" | |
sequence: !input "triple_press" | |
- conditions: | |
- "{{ command == 'move' and move_mode == 'MoveMode.Up' }}" | |
sequence: | |
- repeat: | |
count: 10 | |
sequence: | |
- service: light.turn_on | |
target: !input light | |
data: | |
brightness_step_pct: '{{br_step}}' | |
transition: 0.5 | |
- delay: | |
milliseconds: 500 | |
- conditions: | |
- "{{ command == 'move' and move_mode == 'MoveMode.Down' }}" | |
sequence: | |
- repeat: | |
count: 10 | |
sequence: | |
- service: light.turn_on | |
target: !input light | |
data: | |
brightness_step_pct: '{{br_step | multiply(-1)}}' | |
transition: 0.5 | |
- delay: | |
milliseconds: 500 |
@maxwood I believe this is an issue with the firmware on the remote itself, for me a single press would produce 3 calls in the HA logbook. I was unable to implement a filter for this in yaml as it's way too annoying. I maybe one day will try AppDaemon to fix this. In the meantime I recommend setting up OTA, maybe an update will fix this.
Actually it looks like it fixed itself @maxwood After updating HA and having OTA set up for about a month it seems to have fixed itself on my end.
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
I'm having an issue where single press to toggle the light on/off causes the light to flash instead. Do you have the same problem?