Qubino Mini Dimmer ZMNHHDx OZW 1.4
....
<Product type="0001" id="0055" name="ZMNHHDx Mini Dimmer" config="qubino/ZMNHHDx.xml"/>
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Qubino: ZMNHHDx Mini Dimmer Z-Wave+
https://products.z-wavealliance.org/products/3381
-->
<!-- Configuration -->
<CommandClass id="112">
<Value genre="config" index="1" instance="1" label="In-wall Switch Type for Load to control I1" max="1" min="0" size="1" type="list" value="0">
<Help>With this parameter, you can select between push-button (momentary) and on/off toggle switch types.</Help>
<Item label="Push button" value="0"/>
<Item label="Toggle switch" value="1"/>
</Value>
<Value genre="config" index="5" instance="1" label="Working mode" max="1" min="0" size="1" type="list" value="0">
<Help>With this parameter, you can change the device presentation on the user interface.</Help>
<Item label="Dimmer mode" value="0"/>
<Item label="Switch mode" value="1"/>
</Value>
<Value genre="config" index="11" instance="1" label="Turn Load 1 Off Automatically with Timer" units="second" max="32536" min="0" size="2" type="short" value="0">
<Help>
0 - Auto OFF Disabled.
1 - 32536 = 1 - 32536 seconds - Auto OFF timer enabled for a given amount of seconds.
Default value 0.
</Help>
</Value>
<Value genre="config" index="12" instance="1" label="Turn Load 1 On Automatically with Timer" max="32535" min="0" size="2" type="short" value="0">
<Help>
0 - Auto ON Disabled.
1 - 32536 = 1 - 32536 seconds - Auto ON timer enabled for a given amount of seconds.
Default value 0.
</Help>
</Value>
<Value genre="config" index="21" instance="1" label="Double click function" max="1" min="0" size="1" type="list" value="0">
<Help>
If the Double click function is enabled, a fast double click on the push-button will set the dimming level to the maximum dimming value.
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value genre="config" index="30" instance="1" label="Restore on/off status for load after power failure" max="1" min="0" size="1" type="list" value="0">
<Help>Default value 0.</Help>
<Item label="Device saves last on/off status and restores it after a power failure" value="0"/>
<Item label="Device does not save on/off status" value="1"/>
</Value>
<Value genre="config" index="40" instance="1" label="Watt Power Consumption Reporting Threshold for Load" units="%" max="100" min="0" size="1" type="byte" value="5">
<Help>Set value from 0 - 100 (0% - 100%).
0 - Reporting Disabled.
1 - 100 = 1% - 100% Reporting enabled.
Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%.
Default value 5.</Help>
</Value>
<Value genre="config" index="42" instance="1" label="Watt Power Consumption Reporting Time Threshold for Load" units="second" max="32767" min="0" type="short" value="300">
<Help>Set value means time interval (0 - 32767) in seconds, when power report is send.
0 - Reporting Disabled.
1 second to 32767 seconds reporting enabled.
Power report is send with time interval set by entered value.
Default value 300 (power report in Watts is send each 300s).</Help>
</Value>
<Value genre="config" index="60" instance="1" label="Minimum dimming value" max="98" min="1" type="byte" value="1">
<Help>1 - 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value.
Default value 1 (Minimum dimming value is 1%).</Help>
</Value>
<Value genre="config" index="61" instance="1" label="Maximum dimming value" max="99" min="2" type="byte" value="99">
<Help>2 - 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value.
Default value 99 (Maximum dimming value is 99%).</Help>
</Value>
<Value genre="config" index="65" instance="1" label="Dimming time (soft on/off)" max="255" min="1" type="short" value="100">
<Help>Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through.
1- 255 = 10mseconds - 2550mseconds (2,55s), step is 10mseconds.
Default value 100 (Dimming time between min. and max. dimming values is 1s).</Help>
</Value>
<Value genre="config" index="66" instance="1" label="Dimming time when key hold" max="255" min="1" type="short" value="3">
<Help>
Choose the time during which the Dimmer will move between the min. and max. dimming values during a continuous press of the push-button I1, by an associated device or through the UI controls (BasicSet, SwitchMultilevelSet)
default value 3 = 3s.
1-127 = 1 second – 127 seconds.
128 – 253 = 1 minute – 126 minutes.
</Help>
</Value>
<Value genre="config" index="67" instance="1" label="Ignore start level" max="1" min="0" size="1" type="list" value="0">
<Help>
Choose whether the device should use (or disregard) the start dimming level value.
If the device is configured to use the start level, it should start the dimming process from the currently set dimming level.
This parameter is used with association group 3
</Help>
<Item label="Use the start level value" value="0"/>
<Item label="Ignore start level" value="1"/>
</Value>
<Value genre="config" index="68" instance="1" label="Dimming duration" max="127" min="0" size="1" type="byte" value="0">
<Help>
Choose the time during which the device will transition from the current value to the new target value.
This parameter applies to the association group 3.
default value 0 (dimming duration according to parameter 66).
1 - 127 (from 1 to 127 seconds).
</Help>
</Value>
<Value genre="config" index="70" instance="1" label="Overload safety switch" units="watt" max="255" min="1" type="short" value="200">
<Help>
The function allows for turning off the controlled device in case of exceeding the defined power for more than 5s.
Controlled device can be turned back on by input I1 or sending a control frame.
0 = function not active
1–200=1W–200W
</Help>
</Value>
<Value genre="config" index="71" instance="1" label="Calibration trigger" max="2" min="0" size="1" type="list" value="0">
<Help>
Choose when will be the calibration procedure triggered.
</Help>
<Item label="Calibration done after power cycle if module is excluded" value="0"/>
<Item label="Calibration done after power cycle regardless of inclusion status" value="1"/>
<Item label="Force calibration" value="2"/>
</Value>
<Value genre="config" index="72" instance="1" label="Calibration trigger" max="2" min="1" size="1" type="list" value="2" read_only="true">
<Help>
Whit this parameter you can check the calibration status.
</Help>
<Item label="Calibration was successful" value="1"/>
<Item label="Calibration failed" value="2"/>
</Value>
<Value genre="config" index="73" instance="1" label="Alarm/Notification events" max="3" min="1" size="1" type="list" value="0">
<Help>
This parameter defines the module behaviour in case it receives any Alarm/Notification events.
</Help>
<Item label="Function not active" value="0"/>
<Item label="Turn OFF" value="1"/>
<Item label="Turn ON" value="2"/>
<Item label="Start blinking" value="3"/>
</Value>
<Value genre="config" index="74" instance="1" label="Alarm/Notification time interval" units="minute" max="125" min="1" size="1" type="byte" value="0">
<Help>
This parameter defines the time interval of the blinking state, once the module receives an alarm/notification event.
Minimum step increase is 1 minute.
1 - 127 (from 1 to 125 minutes).
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="4">
<Group index="1" label="Lifeline" max_associations="1"/>
<Group index="2" label="Basic OnOff" max_associations="16"/>
<Group index="3" label="StartStop level change" max_associations="16"/>
<Group index="4" label="Multilevel set" max_associations="16"/>
</Associations>
</CommandClass>
<!-- Remove COMMAND_CLASS_BASIC -->
<CommandClass action="remove" id="32"/>
<!-- Map endpoints to instances -->
<CommandClass id="96">
<Compatibility>
<MapRootToEndpoint>true</MapRootToEndpoint>
</Compatibility>
</CommandClass>
</Product>