Save jmmauricio/1198491fa8223572881a to your computer and use it in GitHub Desktop.
import sys | |
sys.path.append(r"C:\DigSILENT15p1p7\python") | |
# import PowerFactory module | |
import powerfactory | |
# start PowerFactory in engine mode | |
app = powerfactory.GetApplication() | |
user = app.GetCurrentUser() | |
# activate project | |
project = app.ActivateProject("Nine Bus System") | |
prj = app.GetActiveProject() | |
ldf = app.GetFromStudyCase("ComLdf") | |
ini = app.GetFromStudyCase('ComInc') | |
sim = app.GetFromStudyCase('ComSim') | |
Shc_folder = app.GetFromStudyCase('IntEvt'); | |
terminals = app.GetCalcRelevantObjects("*.ElmTerm") | |
lines = app.GetCalcRelevantObjects("*.ElmTerm") | |
syms = app.GetCalcRelevantObjects("*.ElmSym") | |
Shc_folder.CreateObject('EvtSwitch', 'evento de generacion'); | |
EventSet = Shc_folder.GetContents(); | |
evt = EventSet[0]; | |
evt.time =1.0 | |
evt.p_target = syms[1] | |
ldf.iopt_net = 0 | |
ldf.Execute() | |
elmres = app.GetFromStudyCase('Results.ElmRes') | |
for terminal in terminals: | |
elmres.AddVars(terminal,'m:u','m:phiu','m:fehz') | |
for sym in syms: | |
elmres.AddVars(sym,'s:xspeed') | |
ini.Execute() | |
sim.Execute() | |
evt.Delete() | |
comres = app.GetFromStudyCase('ComRes'); | |
comres.iopt_csel = 0 | |
comres.iopt_tsel = 0 | |
comres.iopt_locn = 2 | |
comres.ciopt_head = 1 | |
comres.pResult=elmres | |
comres.f_name = r'C:\Users\jmmauricio\hola.txt' | |
comres.iopt_exp=4 | |
comres.Execute() |
i searched for a long time now to find all attributes a element can have. Is there a list i didnt know about?
the easiest one will be the column header has the same name with load name in PowerFactory. And then you can map it like this:
loads_data = app.GetRelevantObjects('*.ElmLod')
for load in loads_data:
try:
load_curve = df[load.GetAttribute('loc_name']
except:
print(f'load curve for {load.GetAttribute('loc_name']} not found') #catching error because load name is not in data
Hi. I want to know if someone can help me in a issue that I´m having on Digsilent 2023... I want to know if it is posible to modify a setpoint value of a controller of a STATCOM during a RMS simulation; specifically when one specific line trips off (Meaning that the system would be running in N-1 condittions), for instance, at that moment when N-1 scenario occurs, instead of a setpoint value of 1 pu voltage at certain busbar, the statcom change that setpoint to look up for 0.98 pu. voltage.... Please if you can help me I´ll appreciate it.
Hi Everyone, did anybody know how can i create static generator objects in my project and then need to read date from csv file in order to give every photovoltic (static generator) their power and other properties??
Hello, . I'm trying to implement rms simulation via python code and I ran into a problem. I want to extract the value of a variable at a specific moment in time, but I don't know how to do it. can someone help me please? Regards!
Hi
I want to add a shunt element to a bus. How can I do it?
Thanks.
When I close powerfactory, I run the following python script:
import sys sys.path.append( r"C:\Program Files\DIgSILENT\PowerFactory 2022\Python\3.10") if __name__ == "__main__": import powerfactory app = powerfactory.GetApplication() if app is None: raise Exception('getting Powerfactory application failed')
Error reported:
Process finished with exit code -1073741819 (0xC0000005)
Tried many methods to no avail, if you have a similar situation and successfully solved it, or if you have other suggestions, please let me know, thank you for your help, it is greatly appreciated
import os
os.environ["PATH"]=r"C:\DIgSILENT\PF 2023_SP5"+os.environ["PATH"]
import sys
sys.path.append(r"C:\DIgSILENT\PF 2023_SP5\Python\3.8")
#IMPORTAR LA APLICACION
try:
import powerfactory as pf
app = pf.GetApplication()
app.Show()
outputWindow = app.GetOutputWindow()
outputWindow.Print(pf.OutputWindow.MessageType.Plain, "Hello World!")
except Exception as e:
print("Error corregir",e)
Only close powerfactory, If powerfactory is run, Engine mode with Digrcom.
@rizky-r-lab I want to extract simulation RMS parameters like transient reactances and change them according to the size of the machine