# open evcc at http://evcc.local:7070
network:
schema: http
host: evcc.local # .local suffix announces the hostname on MDNS
port: 7070
log: trace
levels:
cache: error
# unique installation id
plant: ***
sponsortoken: ***
telemetry: true
interval: 30s # control cycle interval
mqtt:
broker: 172.16.120.245:1883
user: mqtt
password: ***
topic: evcc
meters:
- type: custom
name: grid1
power:
source: mqtt
topic: pvdataevcc/sensor/grid_power_consumption_ac_power
timeout: 30s
#topic value is negative
scale: -1
- type: custom
name: wechselrichter2
power:
source: mqtt
topic: pvdataevcc/sensor/pv02_power_meter_active_power
scale: 1
timeout: 30s
- type: custom
name: wechselrichter1
power:
source: mqtt
topic: pvdataevcc/sensor/pv01_power_meter_active_power
scale: 1
timeout: 30s
- name: boilerpower
type: custom
power:
source: mqtt
topic: pvdataevcc/sensor/boiler_consumption
chargers:
- type: template
template: twc3
host: 172.16.90.150
name: teslabox1
- type: template
template: twc3
host: 172.16.90.149
name: teslabox2
- type: template
template: tasmota
host: 172.16.90.73
channel: 1
standbypower: -1
icon: waterheater
name: waterheaterbox
heating: true
vehicles:
- type: template
template: tesla
title: Egon
accessToken: ***
refreshToken: ***
vin: ***
capacity: 76.8
name: egon
commandProxy: http://172.16.80.77:8080
- type: template
template: tesla
title: Rennate
accessToken: ***
refreshToken: ***
vin: ***
capacity: 76.8
name: rennate
commandProxy: http://172.16.80.77:8080
- name: waterheater
type: custom
title: Boiler
phases: 3
soc:
source: mqtt
topic: pvdataevcc/sensor/boiler_temp
timeout: 30s
loadpoints:
- title: Hausecke
charger: teslabox1
mode: pv
priority: 1
- title: Garage
charger: teslabox2
mode: pv
priority: 1
- title: Warmwasser
#7,5kw
meter: boilerpower
charger: waterheaterbox
mode: pv
priority: 0
vehicle: waterheater
soc:
estimate: false
poll:
mode: always
interval: 20s
disable:
threshold: 0
delay: 15m # Laufzeit min 15m
enable:
threshold: 0
delay: 1m
tariffs:
currency: EUR
grid:
type: fixed
price: 0.1548 # EUR/kWh
zones:
- days: Mo-So
hours: 22-0,0-6
price: 0.129
feedin:
type: fixed
price: 0.0629
site:
title: Mein Zuhause
meters:
grid: grid1
pv:
- wechselrichter2
- wechselrichter1
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment