Home Assistant Blueprint: Low battery level detection & notification for all battery sensors with Time Pattern
blueprint:
name: Low battery level detection & notification for all battery sensors with Time Pattern Detection
description: Regularly test all sensors with 'battery' device-class for crossing
a certain battery level threshold and if so execute an action. Modified version to allow for Time-Pattern based detection.
domain: automation
input:
threshold:
name: Battery warning level threshold
description: Battery sensors below threshold are assumed to be low-battery (as
well as binary battery sensors with value 'on').
default: 20
selector:
number:
min: 5.0
max: 100.0
unit_of_measurement: '%'
mode: slider
step: 5.0
hours:
name: Hour (time pattern)
description: When to trigger, '*' for any hour, 0-23 for the specific hour of the day. (or other time-pattern)
default: '*'
selector:
text:
minuites:
name: Minute (time pattern)
description: When to trigger, '*' for any hour, 0-59 for the specific minute of the hour. (or other time-pattern)
default: '*'
selector:
text:
seconds:
name: Second (time pattern)
description: When to trigger, '*' for any hour, 0-59 for the specific second of the minute. (or other time-pattern)
default: '1'
selector:
text:
day:
name: Weekday to test on
description: 'Test is run at configured time either everyday (0) or on a given
weekday (1: Monday ... 7: Sunday)'
default: 0
selector:
number:
min: 0.0
max: 7.0
mode: slider
step: 1.0
exclude:
name: Excluded Sensors
description: Battery sensors (e.g. smartphone) to exclude from detection. Only entities are supported, devices must be expanded!
default: {entity_id: []}
selector:
target:
entity:
device_class: battery
actions:
name: Actions
description: Notifications or similar to be run. {{sensors}} is replaced with
the names of sensors being low on battery.
selector:
action: {}
source_url: https://gist.github.com/sbyx/1f6f434f0903b872b84c4302637d0890
variables:
day: !input 'day'
threshold: !input 'threshold'
exclude: !input 'exclude'
sensors: >-
{% set result = namespace(sensors=[]) %}
{% for state in states.sensor | selectattr('attributes.device_class', '==', 'battery') %}
{% if 0 <= state.state | int(-1) < threshold | int and not state.entity_id in exclude.entity_id %}
{% set result.sensors = result.sensors + [state.name ~ ' (' ~ state.state ~ ' %)'] %}
{% endif %}
{% endfor %}
{% for state in states.binary_sensor | selectattr('attributes.device_class', '==', 'battery') | selectattr('state', '==', 'on') %}
{% if not state.entity_id in exclude.entity_id %}
{% set result.sensors = result.sensors + [state.name] %}
{% endif %}
{% endfor %}
{{result.sensors|join(', ')}}
trigger:
- platform: time_pattern
hours: !input 'hours'
minutes: !input 'minuites'
seconds: !input 'seconds'
condition:
- '{{ sensors != '''' and (day | int == 0 or day | int == now().isoweekday()) }}'
action:
- choose: []
default: !input 'actions'
mode: single
@rcblackwell
Copy link

Okay, figured out the problem! With hours and seconds set to "*", the action is fired every other second. To get around this I set the seconds to 1. Now the message is sent once, 1 second after the specified minutes.

@lymbada
Copy link
Author

lymbada commented Apr 8, 2022

Hey rclackwell
I had indeed done both of those updates for the description, and also set the default for second to ‘1’ - should be revision 16. (as I found the exact same thing, I guess time-patterns is not the same as typical cron).
I guess you had an earlier download… or I forgot to publish the changes? if you have a moment could you re-check the file (in gist.github.com) and let me know if you see the updates?
Cheers
Matt

@rcblackwell
Copy link

Hi Matt,

The blueprint I’m using came from git yesterday. It matches what I see posted today. I see there is a default of 1 for seconds. Perhaps the blueprint shouldn’t allow “*” to be utilized for seconds? Only allow 0-59. Now that I understand how time works, I don’t see a situation where the wildcard would/could be used. Eliminating the wildcard choice would eliminate the problem I (and you) saw earlier.

As for descriptions; the minutes and second description still read in part "When to trigger, ‘*’ for any hour , 0-59 for the specific ". In the case of minutes, should the word hour not be replaced with minute , and in the case of seconds , should it not be replaced with seconds ?

@rcblackwell
Copy link

Hi Matt,

Noticed one more thing - When I load the blueprint into Studio Code Server for editing, an error is reported on line 61. The {}'s are not required after "action:"

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment