# Based off Mark Gardiner's script here: | |
# https://gist.github.com/markgdev/ce2dbf9002385cbe5a35b81985f9c84a | |
# I've added some tweaks to get additional information out of the inverter. | |
# Note: the InverterStatus gathering (for fault reporting) is wrong, I'm pretty sure I've got my hex conversion wrong | |
# I know the last two batter statuses are correct as that's what the system reported when I had a battery fault :-) | |
## | |
import minimalmodbus | |
import time | |
import paho.mqtt.publish as publish | |
instrument = minimalmodbus.Instrument('/dev/ttyUSB0', 1, debug = False) | |
instrument.serial.baudrate = 9600 | |
# This probably doesn't need setting but I was getting timeout failures | |
# rather than wrong data address when I had the registers wrong | |
instrument.serial.timeout = 2 | |
# An example read for long | |
# instrument.read_long(33004, functioncode=4, signed=False) | |
# MQTT | |
# mqtt = os.environ['USE_MQTT'] | |
mqtt_client = "solar-Pi" | |
mqtt_server = "127.0.0.1" | |
mqtt_username = "" | |
mqtt_password = "" | |
debug = False | |
InverterStatusDict = { | |
0: 'Waiting', | |
1: 'Open Loop', | |
2: 'SoftRun', | |
3: 'Normal/Generating', | |
4100: 'Off-Grid ', | |
4112: 'Grid overvoltage OV-G-V', | |
4113: 'Grid undervoltage UN-G-V', | |
4114: 'Grid overfrequency OV-G-F', | |
4115: 'Grid underfrequency UN-G-F', | |
4116: 'Grid impedance is too large G-IMP', | |
4117: 'No Grid', | |
4118: 'Grid imbalance G-PHASE', | |
4119: 'Grid frequency jitter G-F-FLU', | |
4120: 'Grid overcurrent OV-G-I', | |
4121: 'Grid current tracking fault IGFOL-F', | |
4122: 'DC overvoltage OV-DC', | |
4129: 'DC bus overvoltage OV-BUS', | |
4130: 'DC busbar uneven voltage UNB-BUS', | |
4131: 'DC bus undervoltage UN-BUS', | |
4132: 'DC busbar uneven voltage 2 UNB2-BUS', | |
4133: 'DC A way overcurrent OV-DCA-I', | |
4134: 'DC B path overcurrent OV-DCB-I', | |
4135: 'DC input disturbance DC-INTF', | |
4144: 'Grid disturbance GRID-INTF', | |
4145: 'DSP initialization protection INI-Fault', | |
4146: 'Overtemperature protection OV-TEM', | |
4147: 'PV insulation fault PV ISO-PRO', | |
4148: 'Leakage current protection ILeak-PRO', | |
4149: 'Relay detection protection RelayChk-FAIL', | |
4150: 'DSP_B protection DSP-B-FAULT', | |
4151: 'DC component is too large DCInj-FAULT', | |
4152: '12V undervoltage protection 12Power-FAULT', | |
4153: 'Leakage current self-test protection ILeak-Check', | |
4154: 'Under temperature protection UN-TEM', | |
4160: 'Arc self-test protection AFCI-Check', | |
4161: 'Arc protection ARC-FAULT', | |
4162: 'DSP on-chip SRAM exception RAM-FAULT', | |
4163: 'DSP on-chip FLASH exception FLASH-FAULT', | |
4164: 'DSP on-chip PC pointer is abnormal PC-FAULT', | |
4165: 'DSP key register exception REG-FAULT', | |
4166: 'Grid disturbance 02 GRID-INTF02', | |
4167: 'Grid current sampling abnormality IG-AD', | |
4168: 'IGBT overcurrent IGBT-OV-I', | |
4176: 'Network side current transient overcurrent OV-IgTr', | |
4177: 'Battery overvoltage hardware failure OV-Vbatt-H', | |
4178: 'LLC hardware overcurrent OV-ILLC', | |
4179: 'Battery overvoltage detection OV-Vbatt', | |
4180: 'Battery undervoltage detection UN-Vbatt', | |
4181: 'Battery no connected NO-Battery', | |
4182: 'Bypass overvoltage fault OV-VBackup', | |
4183: 'Bypass overload fault Over-Load', | |
8210: 'No Battery', | |
8213: 'Battery Alarm' | |
} | |
def get_status(): | |
# Inverter Temp | |
inverter_temp = instrument.read_register(33093, functioncode=4, number_of_decimals=1, signed=False) | |
# Inverter Time | |
inverter_time_hour = instrument.read_register(33025, functioncode=4, signed=False) | |
inverter_time_min = instrument.read_register(33026, functioncode=4, signed=False) | |
inverter_time_sec = instrument.read_register(33027, functioncode=4, signed=False) | |
# Battery Status, 0=Charge, 1=Discharge | |
battery_status = instrument.read_register(33135, functioncode=4, signed=False) | |
# Battery SOC | |
battery_soc = instrument.read_register(33139, functioncode=4, signed=False) | |
# Grid Power (w), Positive=Export, Negative=Import | |
grid_power = instrument.read_long(33130, functioncode=4, signed=True) | |
# House load power (w) | |
house_power = instrument.read_register(33147, functioncode=4, signed=False) | |
# Battery Power (w) | |
battery_power = instrument.read_long(33149, functioncode=4, signed=True) | |
if battery_status == 0: | |
battery_abs = battery_power | |
else: | |
battery_abs = -battery_power | |
# Current generation (Active power) (w), need to confirm when generating | |
current_generation = instrument.read_long(33057, functioncode=4, signed=False) | |
total_active_power = instrument.read_long(33263, functioncode=4, signed=True) | |
# instrument.read_long(33079, functioncode=4, signed=True) | |
# possibly this too 33263? "Meter total active power" | |
inverter_status = instrument.read_register(33095, functioncode=4, signed=False) | |
# Total generation today (kWh) | |
generation_today = instrument.read_register(33035, functioncode=4, number_of_decimals=1, signed=False) | |
# Total generation yesterday (kWh) | |
generation_yesterday = instrument.read_register(33036, functioncode=4, number_of_decimals=1, signed=False) | |
# Grid import power yesterday (kWh) | |
grid_import_yesterday = instrument.read_register(33172, functioncode=4, number_of_decimals=1, signed=False) | |
# Grid export power yesterday (kWh) | |
grid_export_yesterday = instrument.read_register(33176, functioncode=4, number_of_decimals=1, signed=False) | |
# Grid export power yesterday (kWh) | |
house_load_yesterday = instrument.read_register(33180, functioncode=4, number_of_decimals=1, signed=False) | |
# Battery storage mode, 33=self use, 35=timed charge | |
storage_mode = instrument.read_register(43110, functioncode=3, signed=False) | |
if debug: | |
print(f"Inverter time: {str(inverter_time_hour).zfill(2)}:{str(inverter_time_min).zfill(2)}:{str(inverter_time_sec).zfill(2)}") | |
print(f"Inverter Temperature: {inverter_temp}") | |
print(f"Battery Status: {battery_status}") | |
print(f"Inverter Status: {inverter_status}") | |
print(f"Battery SOC: {battery_soc}") | |
print(f"Grid Power: {grid_power}") | |
print(f"House Power: {house_power}") | |
print(f"Battery Power: {battery_power}") | |
print(f"Current Generation: {current_generation}") | |
print(f"Total Active Power: {total_active_power}") | |
print(f"Generation Today: {generation_today}") | |
print(f"Generation Yesterday: {generation_yesterday}") | |
print(f"Grid Import Yesterday: {grid_import_yesterday}") | |
print(f"Grid Export Yesterday: {grid_export_yesterday}") | |
print(f"House Load Yesterday: {house_load_yesterday}") | |
print(f"Battery Storage Mode: {storage_mode}") | |
# Push to MQTT | |
msgs = [] | |
mqtt_topic = ''.join([mqtt_client, "/" ]) # Create the topic base using the client_id and serial number | |
if (mqtt_username != "" and mqtt_password != ""): | |
auth_settings = {'username':mqtt_username, 'password':mqtt_password} | |
else: | |
auth_settings = None | |
msgs.append((mqtt_topic + "Battery_Charge_Percent", battery_soc, 0, False)) | |
msgs.append((mqtt_topic + "Battery_Power", battery_power, 0, False)) | |
msgs.append((mqtt_topic + "Battery_Abs", battery_abs, 0, False)) | |
msgs.append((mqtt_topic + "Battery_Status", battery_status, 0, False)) | |
if inverter_status in InverterStatusDict: | |
msgs.append((mqtt_topic + "Inverter_Status", InverterStatusDict[inverter_status], 0, False)) | |
else: | |
msgs.append((mqtt_topic + "Inverter_Status", inverter_status, 0, False)) | |
msgs.append((mqtt_topic + "Power_Grid_Total_Power", grid_power, 0, False)) | |
# Fix to match what we get from m.ginlong.com while we're switching between the two | |
Power_Grid_Status = 2.0 # Default to importing | |
if grid_power > 0: | |
Power_Grid_Status = 1.0 | |
msgs.append((mqtt_topic + "Power_Grid_Status", Power_Grid_Status, 0, False)) | |
msgs.append((mqtt_topic + "Consumption_Power", house_power, 0, False)) | |
msgs.append((mqtt_topic + "AC_Power", current_generation, 0, False)) | |
msgs.append((mqtt_topic + "generation_today", generation_today, 0, False)) | |
msgs.append((mqtt_topic + "generation_yesterday", generation_yesterday, 0, False)) | |
msgs.append((mqtt_topic + "grid_import_yesterday", grid_import_yesterday, 0, False)) | |
msgs.append((mqtt_topic + "grid_export_yesterday", grid_export_yesterday, 0, False)) | |
msgs.append((mqtt_topic + "house_load_yesterday", house_load_yesterday, 0, False)) | |
msgs.append((mqtt_topic + "inverter_temp", inverter_temp, 0, False)) | |
msgs.append((mqtt_topic + "storage_mode", storage_mode, 0, False)) | |
publish.multiple(msgs, hostname=mqtt_server, auth=auth_settings) | |
def timed_charge(): | |
# We can use read_registers to grab all the values in one call: | |
# instrument.read_registers(43143, number_of_registers=8, functioncode=3) | |
# Not going to check charge/discharge for now, we haven't implemented it yet. | |
# Timed charge start | |
# Hour | |
charge_start_hour = instrument.read_register(43143, functioncode=3, signed=False) | |
# Minute | |
charge_start_min = instrument.read_register(43144, functioncode=3, signed=False) | |
# Timed charge end | |
# Hour | |
charge_end_hour = instrument.read_register(43145, functioncode=3, signed=False) | |
# Minute | |
charge_end_min = instrument.read_register(43146, functioncode=3, signed=False) | |
# Timed discharge start | |
# Hour | |
discharge_start_hour = instrument.read_register(43147, functioncode=3, signed=False) | |
# Minute | |
discharge_start_min = instrument.read_register(43148, functioncode=3, signed=False) | |
# Timed discharge end | |
# Hour | |
discharge_end_hour = instrument.read_register(43149, functioncode=3, signed=False) | |
# Minute | |
discharge_end_min = instrument.read_register(43150, functioncode=3, signed=False) | |
print(f"Charge Start: {charge_start_hour}:{charge_start_min}") | |
print(f"Charge End: {charge_end_hour}:{charge_end_min}") | |
print(f"Discharge Start: {discharge_start_hour}:{discharge_start_min}") | |
print(f"Discharge End: {discharge_end_hour}:{discharge_end_min}") | |
# Change charge start time minute, will work the same for the othe values. | |
# instrument.write_register(43144, functioncode=6, signed=False, value=54) | |
# We can write all the times in one call with write_registers: | |
# instrument.write_registers(43143, [18, 00, 8, 0, 8, 0, 18, 0]) | |
# Storage control switch | |
# 33 = Self use mode | |
# 35 = Timed charge mode | |
# Read/Write register | |
# instrument.read_register(43110, functioncode=3, signed=False) | |
# instrument.write_register(43110, functioncode=6, signed=False, value=33) | |
# instrument.write_register(43110, functioncode=6, signed=False, value=35) | |
# Read only register | |
# instrument.read_register(33132, functioncode=4, signed=False) | |
while True: | |
try: | |
get_status() | |
except Exception as e: | |
print(e) | |
print("Failed to query inverter, backing off for 30 seconds") | |
time.sleep(30) | |
if debug: | |
print("-------------------------------") | |
time.sleep(5) |