Pour se procurer un DTU avec OpenDTU: http://bit.ly/opendtu

Jour:

image

Nuit:

image

Autres:

image

image

HA Config

In global config:

homeassistant:
  packages: !include_dir_named packages

Then put opendtu.yaml files in config/packages folder

view.yaml is the Lovelace card section above

energy.yaml is optional: you can take it. It shows how I compute the home consumed energy and solar consumed energy with a shelly EM. If yo utake it, you can setup some graph like that:

image

template:
# https://www.home-assistant.io/integrations/sensor/
- sensor:
- name: Solar Consumed Power
unique_id: "01e37eed-3045-4eee-a786-1249567fe303"
state_class: measurement
device_class: power
unit_of_measurement: W
availability: "{{ ['sensor.solar_production_power', 'sensor.grid_returned_power']|map('states')|map('is_number')|min }}"
state: "{{ [states.sensor.solar_production_power.state|float - states.sensor.grid_returned_power.state|float, 0] | max }}"
- name: Home Consumed Power
unique_id: BE34D1AD-AB8E-4909-ACE0-BBA7D3877105
state_class: measurement
device_class: power
unit_of_measurement: W
availability: "{{ ['sensor.solar_production_power', 'sensor.grid_power']|map('states')|map('is_number')|min }}"
state: "{{ states.sensor.solar_production_power.state|float + states.sensor.grid_power.state|float }}"
- name: Solar Consumed Energy Daily
unique_id: "01e37eed-3045-4eee-a786-1249567fe305"
state_class: total_increasing
device_class: energy
unit_of_measurement: kWh
availability: "{{ ['sensor.inverters_energy_meter_daily', 'sensor.grid_energy_returned_meter_daily']|map('states')|map('is_number')|min }}"
state: >-
{% set c = states.sensor.solar_consumed_energy_daily.state|float(0) %}
{% set p = states.sensor.inverters_energy_meter_daily.state|float %}
{% set e = states.sensor.grid_energy_returned_meter_daily.state|float %}
{{ [0 if p == 0 or p < c else c, [0, p - e] | max] | max }}
- name: Solar Autoconsumption Level Daily
unique_id: "01e37eed-3045-4eee-a786-1249567fe304"
state_class: measurement
unit_of_measurement: "%"
availability: "{{ ['sensor.grid_energy_returned_meter_daily', 'sensor.inverters_energy_meter_daily']|map('states')|map('is_number')|min and states.sensor.inverters_energy_meter_daily.state|float(0) > 0 }}"
state: "{{ [100, (100 - 100 * states.sensor.grid_energy_returned_meter_daily.state|float / states.sensor.inverters_energy_meter_daily.state|float )] | min }}"
sensor:
# https://www.home-assistant.io/integrations/integration/
- platform: integration
name: Home Consumed Energy
unique_id: E2BA4424-8CA8-4D74-9A2F-F0E5EFF84622
source: sensor.home_consumed_power
unit_prefix: k
mqtt:
# https://www.home-assistant.io/integrations/sensor.mqtt
sensor:
- name: Inverters YieldTotal
unique_id: D6A6659B-EE6A-4C3F-91F4-C0FBD46E8CF5
state_class: total_increasing
device_class: energy
unit_of_measurement: "kWh"
state_topic: "opendtu/ac/yieldtotal"
value_template: "{{ value|float }}"
availability_topic: "opendtu/ac/is_valid"
payload_available: "1"
payload_not_available: "0"
- name: Inverters YieldDay
unique_id: "01e37eed-3045-4eee-a786-1249567fe310"
state_class: total_increasing
device_class: energy
unit_of_measurement: "kWh"
state_topic: "opendtu/ac/yieldday"
value_template: "{{ value|float / 1000.0 }}"
availability_topic: "opendtu/ac/is_valid"
payload_available: "1"
payload_not_available: "0"
- name: Inverters Power
unique_id: "01e37eed-3045-4eee-a786-1249567fe315"
state_class: measurement
device_class: power
unit_of_measurement: W
state_topic: "opendtu/ac/power"
value_template: "{{ value|int }}"
availability_topic: "opendtu/ac/is_valid"
payload_available: "1"
payload_not_available: "0"
- name: Inverters PowerDC
unique_id: "01e37eed-3045-4eee-a786-1249567fe316"
state_class: measurement
device_class: power
unit_of_measurement: W
state_topic: "opendtu/dc/power"
value_template: "{{ value|int }}"
availability_topic: "opendtu/dc/is_valid"
payload_available: "1"
payload_not_available: "0"
template:
# https://www.home-assistant.io/integrations/sensor/
- sensor:
- name: Inverters Energy
unique_id: 6E14EC86-0965-463E-BFBF-6008B61B56AF
state_class: total_increasing
device_class: energy
unit_of_measurement: "kWh"
state: "{{ [states.sensor.inverters_yieldtotal.state|float(0), states.sensor.inverters_energy.state|float(0) ] | max }}"
- name: Inverter 1 Adjusted Irradiation
unique_id: C47E36DF-4FCD-40CA-B3C7-8B186A02A015
state_class: measurement
unit_of_measurement: "%"
availability: "{{ ['sensor.inverter_1_powerdc', 'sensor.inverter_1_temperature']|map('states')|map('is_number')|min }}"
state: "{{ [100, states.sensor.inverter_1_powerdc.state|float / (400 * (110 - states.sensor.inverter_1_temperature.state|float * 0.4) / 100) * 100] | min }}"
- name: Inverter 2 Adjusted Irradiation
unique_id: C0EB72EE-725E-42C0-A25F-677BB3984EFA
state_class: measurement
unit_of_measurement: "%"
availability: "{{ ['sensor.inverter_2_powerdc', 'sensor.inverter_2_temperature']|map('states')|map('is_number')|min }}"
state: "{{ [100, states.sensor.inverter_2_powerdc.state|float / (400 * (110 - states.sensor.inverter_2_temperature.state|float * 0.4) / 100) * 100] | min }}"
- name: Inverter 3 Adjusted Irradiation
unique_id: 8A61D828-4545-48AC-9CEB-80C96CEAC421
state_class: measurement
unit_of_measurement: "%"
availability: "{{ ['sensor.inverter_3_powerdc', 'sensor.inverter_3_temperature']|map('states')|map('is_number')|min }}"
state: "{{ [100, states.sensor.inverter_3_powerdc.state|float / (400 * (110 - states.sensor.inverter_3_temperature.state|float * 0.4) / 100) * 100] | min }}"
- name: Inverter 4 Adjusted Irradiation
unique_id: 5B1EB6CC-1CF4-4EBD-B476-1254951BB8EA
state_class: measurement
unit_of_measurement: "%"
availability: "{{ ['sensor.inverter_4_powerdc', 'sensor.inverter_4_temperature']|map('states')|map('is_number')|min }}"
state: "{{ [100, states.sensor.inverter_4_powerdc.state|float / (400 * (110 - states.sensor.inverter_4_temperature.state|float * 0.4) / 100) * 100] | min }}"
- name: Inverter 5 Adjusted Irradiation
unique_id: 33EBEF2B-F8C0-4E7E-A90B-7C6706F63E1E
state_class: measurement
unit_of_measurement: "%"
availability: "{{ ['sensor.inverter_5_powerdc', 'sensor.inverter_5_temperature']|map('states')|map('is_number')|min }}"
state: "{{ [100, states.sensor.inverter_5_powerdc.state|float / (400 * (110 - states.sensor.inverter_5_temperature.state|float * 0.4) / 100) * 100] | min }}"
- name: Inverter 6 Adjusted Irradiation
unique_id: B9B3BEE3-9958-43F9-80A4-06163F5B0022
state_class: measurement
unit_of_measurement: "%"
availability: "{{ ['sensor.inverter_6_powerdc', 'sensor.inverter_6_temperature']|map('states')|map('is_number')|min }}"
state: "{{ [100, states.sensor.inverter_6_powerdc.state|float / (400 * (110 - states.sensor.inverter_6_temperature.state|float * 0.4) / 100) * 100] | min }}"
# https://www.home-assistant.io/integrations/utility_meter/
utility_meter:
inverters_energy_meter_daily:
name: Inverters Energy Meter Daily
unique_id: 4C4D8D06-C9D2-4408-B21A-1274A6E0F041
source: sensor.inverters_energy
cycle: daily
type: vertical-stack
cards:
- type: conditional
conditions:
- entity: binary_sensor.inverter_1_reachable
state: 'off'
card:
square: false
columns: 2
type: grid
cards:
- type: markdown
content: |-
### 112184727305
Position: #1
- type: markdown
content: Déconnecté
style: |
ha-card {
background-color: darkred;
}
- type: conditional
conditions:
- entity: binary_sensor.inverter_1_reachable
state: 'on'
card:
square: false
columns: 8
type: grid
cards:
- type: markdown
content: >-
### 112184727305
Position: #1
{{as_local(states.sensor.inverter_1_power.last_updated).time()|string|truncate(8,
False, '')}}
- type: gauge
entity: sensor.inverter_1_temperature
unit: °C
min: 0
max: 65
needle: true
name: Température
severity:
green: 0
yellow: 45
red: 55
- type: gauge
entity: sensor.inverter_1_adjusted_irradiation
unit: '%'
min: 0
max: 100
needle: true
name: Irradiation
- type: gauge
entity: sensor.inverter_1_efficiency
unit: '%'
min: 82
max: 97
needle: true
name: Efficacité
severity:
green: 92
yellow: 87
red: 0
- type: gauge
entity: sensor.inverter_1_powerdc
unit: W
min: 0
max: 440
needle: true
name: DC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_1_power
unit: W
min: 0
max: 420
needle: true
name: AC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_1_voltage
unit: V
min: 210
max: 250
needle: true
name: Tension
severity:
green: 220
yellow: 0
red: 240
- type: markdown
content: >-
| | |
|:------|:--|
| Day: |
{{(states('sensor.inverter_1_yieldday')|float/1000)|round(2)}} kWh |
| Total: | {{states('sensor.inverter_1_yieldtotal')|float|round}}
kWh |
- type: conditional
conditions:
- entity: binary_sensor.inverter_2_reachable
state: 'off'
card:
square: false
columns: 2
type: grid
cards:
- type: markdown
content: |-
### 112184727286
Position: #2
- type: markdown
content: Déconnecté
style: |
ha-card {
background-color: darkred;
}
- type: conditional
conditions:
- entity: binary_sensor.inverter_2_reachable
state: 'on'
card:
square: false
columns: 8
type: grid
cards:
- type: markdown
content: >-
### 112184727286
Position: #2
{{as_local(states.sensor.inverter_2_power.last_updated).time()|string|truncate(8,
False, '')}}
- type: gauge
entity: sensor.inverter_2_temperature
unit: °C
min: 0
max: 65
needle: true
name: Température
severity:
green: 0
yellow: 45
red: 55
- type: gauge
entity: sensor.inverter_2_adjusted_irradiation
unit: '%'
min: 0
max: 100
needle: true
name: Irradiation
- type: gauge
entity: sensor.inverter_2_efficiency
unit: '%'
min: 82
max: 97
needle: true
name: Efficacité
severity:
green: 92
yellow: 87
red: 0
- type: gauge
entity: sensor.inverter_2_powerdc
unit: W
min: 0
max: 440
needle: true
name: DC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_2_power
unit: W
min: 0
max: 420
needle: true
name: AC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_2_voltage
unit: V
min: 210
max: 250
needle: true
name: Tension
severity:
green: 220
yellow: 0
red: 240
- type: markdown
content: >-
| | |
|:------|:--|
| Day: |
{{(states('sensor.inverter_2_yieldday')|float/1000)|round(2)}} kWh |
| Total: | {{states('sensor.inverter_2_yieldtotal')|float|round}}
kWh |
- type: conditional
conditions:
- entity: binary_sensor.inverter_3_reachable
state: 'off'
card:
square: false
columns: 2
type: grid
cards:
- type: markdown
content: |-
### 112183225593
Position: #3
- type: markdown
content: Déconnecté
style: |
ha-card {
background-color: darkred;
}
- type: conditional
conditions:
- entity: binary_sensor.inverter_3_reachable
state: 'on'
card:
square: false
columns: 8
type: grid
cards:
- type: markdown
content: >-
### 112183225593
Position: #3
{{as_local(states.sensor.inverter_3_power.last_updated).time()|string|truncate(8,
False, '')}}
- type: gauge
entity: sensor.inverter_3_temperature
unit: °C
min: 0
max: 65
needle: true
name: Température
severity:
green: 0
yellow: 45
red: 55
- type: gauge
entity: sensor.inverter_3_adjusted_irradiation
unit: '%'
min: 0
max: 100
needle: true
name: Irradiation
- type: gauge
entity: sensor.inverter_3_efficiency
unit: '%'
min: 82
max: 97
needle: true
name: Efficacité
severity:
green: 92
yellow: 87
red: 0
- type: gauge
entity: sensor.inverter_3_powerdc
unit: W
min: 0
max: 440
needle: true
name: DC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_3_power
unit: W
min: 0
max: 420
needle: true
name: AC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_3_voltage
unit: V
min: 210
max: 250
needle: true
name: Tension
severity:
green: 220
yellow: 0
red: 240
- type: markdown
content: >-
| | |
|:------|:--|
| Day: |
{{(states('sensor.inverter_3_yieldday')|float/1000)|round(2)}} kWh |
| Total: | {{states('sensor.inverter_3_yieldtotal')|float|round}}
kWh |
- type: conditional
conditions:
- entity: binary_sensor.inverter_4_reachable
state: 'off'
card:
square: false
columns: 2
type: grid
cards:
- type: markdown
content: |-
### 112183226560
Position: #4
- type: markdown
content: Déconnecté
style: |
ha-card {
background-color: darkred;
}
- type: conditional
conditions:
- entity: binary_sensor.inverter_4_reachable
state: 'on'
card:
square: false
columns: 8
type: grid
cards:
- type: markdown
content: >-
### 112183226560
Position: #4
{{as_local(states.sensor.inverter_4_power.last_updated).time()|string|truncate(8,
False, '')}}
- type: gauge
entity: sensor.inverter_4_temperature
unit: °C
min: 0
max: 65
needle: true
name: Température
severity:
green: 0
yellow: 45
red: 55
- type: gauge
entity: sensor.inverter_4_adjusted_irradiation
unit: '%'
min: 0
max: 100
needle: true
name: Irradiation
- type: gauge
entity: sensor.inverter_4_efficiency
unit: '%'
min: 82
max: 97
needle: true
name: Efficacité
severity:
green: 92
yellow: 87
red: 0
- type: gauge
entity: sensor.inverter_4_powerdc
unit: W
min: 0
max: 440
needle: true
name: DC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_4_power
unit: W
min: 0
max: 420
needle: true
name: AC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_4_voltage
unit: V
min: 210
max: 250
needle: true
name: Tension
severity:
green: 220
yellow: 0
red: 240
- type: markdown
content: >-
| | |
|:------|:--|
| Day: |
{{(states('sensor.inverter_4_yieldday')|float/1000)|round(2)}} kWh |
| Total: | {{states('sensor.inverter_4_yieldtotal')|float|round}}
kWh |
- type: conditional
conditions:
- entity: binary_sensor.inverter_5_reachable
state: 'off'
card:
square: false
columns: 2
type: grid
cards:
- type: markdown
content: |-
### 112183226985
Position: #5
- type: markdown
content: Déconnecté
style: |
ha-card {
background-color: darkred;
}
- type: conditional
conditions:
- entity: binary_sensor.inverter_5_reachable
state: 'on'
card:
square: false
columns: 8
type: grid
cards:
- type: markdown
content: >-
### 112183226985
Position: #5
{{as_local(states.sensor.inverter_5_power.last_updated).time()|string|truncate(8,
False, '')}}
- type: gauge
entity: sensor.inverter_5_temperature
unit: °C
min: 0
max: 65
needle: true
name: Température
severity:
green: 0
yellow: 45
red: 55
- type: gauge
entity: sensor.inverter_5_adjusted_irradiation
unit: '%'
min: 0
max: 100
needle: true
name: Irradiation
- type: gauge
entity: sensor.inverter_5_efficiency
unit: '%'
min: 82
max: 97
needle: true
name: Efficacité
severity:
green: 92
yellow: 87
red: 0
- type: gauge
entity: sensor.inverter_5_powerdc
unit: W
min: 0
max: 440
needle: true
name: DC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_5_power
unit: W
min: 0
max: 420
needle: true
name: AC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_5_voltage
unit: V
min: 210
max: 250
needle: true
name: Tension
severity:
green: 220
yellow: 0
red: 240
- type: markdown
content: >-
| | |
|:------|:--|
| Day: |
{{(states('sensor.inverter_5_yieldday')|float/1000)|round(2)}} kWh |
| Total: | {{states('sensor.inverter_5_yieldtotal')|float|round}}
kWh |
- type: conditional
conditions:
- entity: binary_sensor.inverter_6_reachable
state: 'off'
card:
square: false
columns: 2
type: grid
cards:
- type: markdown
content: |-
### 112183219226
Position: #6
- type: markdown
content: Déconnecté
style: |
ha-card {
background-color: darkred;
}
- type: conditional
conditions:
- entity: binary_sensor.inverter_6_reachable
state: 'on'
card:
square: false
columns: 8
type: grid
cards:
- type: markdown
content: >-
### 112183219226
Position: #6
{{as_local(states.sensor.inverter_6_power.last_updated).time()|string|truncate(8,
False, '')}}
- type: gauge
entity: sensor.inverter_6_temperature
unit: °C
min: 0
max: 65
needle: true
name: Température
severity:
green: 0
yellow: 45
red: 55
- type: gauge
entity: sensor.inverter_6_adjusted_irradiation
unit: '%'
min: 0
max: 100
needle: true
name: Irradiation
- type: gauge
entity: sensor.inverter_6_efficiency
unit: '%'
min: 82
max: 97
needle: true
name: Efficacité
severity:
green: 92
yellow: 87
red: 0
- type: gauge
entity: sensor.inverter_6_powerdc
unit: W
min: 0
max: 440
needle: true
name: DC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_6_power
unit: W
min: 0
max: 420
needle: true
name: AC
severity:
green: 100
yellow: 200
red: 300
- type: gauge
entity: sensor.inverter_6_voltage
unit: V
min: 210
max: 250
needle: true
name: Tension
severity:
green: 220
yellow: 0
red: 240
- type: markdown
content: >-
| | |
|:------|:--|
| Day: |
{{(states('sensor.inverter_6_yieldday')|float/1000)|round(2)}} kWh |
| Total: | {{states('sensor.inverter_6_yieldtotal')|float|round}}
kWh |
- type: grid
square: false
columns: 8
cards:
- type: markdown
content: '### Total'
- type: markdown
content: ' '
- type: markdown
content: ' '
- type: markdown
content: ' '
- type: gauge
entity: sensor.inverters_powerdc
unit: W
min: 0
max: 2520
needle: true
name: DC Total
severity:
green: 660
yellow: 1320
red: 1980
- type: gauge
entity: sensor.inverters_power
unit: W
min: 0
max: 2520
needle: true
name: AC Total
severity:
green: 630
yellow: 1260
red: 1890
- type: markdown
content: ' '
- type: markdown
content: >-
| | |
|:------|:--|
| Day: |
{{states('sensor.inverters_energy_meter_daily')|float|round(2)}} kWh |
| Total: | {{states('sensor.inverters_energy')|float|round}} kWh |
@Waldi1969
Copy link

Where can I find unique_id inverters_yieldday_kwh and inverters_power

@mathieucarbou
Copy link
Author

These are custom entries (see screenshots) : the goal is to summarize the powers and yields

@Saroumanefr
Copy link

Bonjour, et tout d'abord merci pour votre travail.
J'ai repris votre view.yaml mais j'ai un problème au niveau de l'affichage qui ne prend pas toute la largeur de la page, ce qui fait que les colonnes sont trop petites et donc illisibles. Une image étant plus parlante, voilà ce que ça donne :
Capture d'écran 2023-12-03 094141
Etant totalement débutant sur HA, je ne comprends pas d'où vient le souci.
Merci d'avance pour votre aide

@mathieucarbou
Copy link
Author

Très facile: il faut configurer les options de la vue comme ça:
image

@Saroumanefr
Copy link

Saroumanefr commented Dec 3, 2023

Merci beaucoup, c'était effectivement très simple....

@Saroumanefr
Copy link

Bonjour, Les sensors invertors_powerdc et inverters_power ne fonctionnent pas, ça me dit "l'entité n'est actuellement pas disponible". Il y a quelque chose à modifier quelque part ?

@mathieucarbou
Copy link
Author

Bonjour, Les sensors invertors_powerdc et inverters_power ne fonctionnent pas, ça me dit "l'entité n'est actuellement pas disponible". Il y a quelque chose à modifier quelque part ?

Ils sont dans opendtu.yaml

@Saroumanefr
Copy link

Oui je les ai bien vus et j'ai bien mis l'opendtu.yaml dans le dossier config/packages comme indiqué c'est pour ça que je me demandais s'il y a avait des choses à changer/modifier pour que ça fonctionne avec mes appareils.

@mathieucarbou
Copy link
Author

Oui je les ai bien vus et j'ai bien mis l'opendtu.yaml dans le dossier config/packages comme indiqué c'est pour ça que je me demandais s'il y a avait des choses à changer/modifier pour que ça fonctionne avec mes appareils.

Vérifier si vous voyez ces entités dans la liste des entités à http://homeassistant.local:8123/config/entities

Si vous ne les voyez pas, c'est qu'il vous manque une configuration afin que le fichier soit pris en compte.

@Saroumanefr
Copy link

Elles y sont bien mais avec un ! en bout de ligne
Capture d'écran 2023-12-06 105608

@mathieucarbou
Copy link
Author

Elles y sont bien mais avec un ! en bout de ligne Capture d'écran 2023-12-06 105608

Alors c'est votre config mqtt qui n'est pas bonne.
Regardez les topics utilisés dans les yaml, et comparez avec ceux que vous avez réellement grâce à l'addon MQTT Explorer.

@Saroumanefr
Copy link

Désolé, je patauge totalement.....
Donc dans mqtt explorer j'ai bien un "onglet" solar avec dessous deux "sous-onglets" ac et dc avec à l'intérieur de chaque : power - Yieldtotal et Yieldday qui remontent bien les bonnes valeurs mais je ne sais pas quoi en faire par rapport aux fichiers yaml.
Capture d'écran 2023-12-06 113712

@mathieucarbou
Copy link
Author

Désolé, je patauge totalement..... Donc dans mqtt explorer j'ai bien un "onglet" solar avec dessous deux "sous-onglets" ac et dc avec à l'intérieur de chaque : power - Yieldtotal et Yieldday qui remontent bien les bonnes valeurs mais je ne sais pas quoi en faire par rapport aux fichiers yaml. Capture d'écran 2023-12-06 113712

Essayez de comprendre la configuration yaml... Exemple:

      state_topic: "opendtu/ac/power"
      value_template: "{{ value|int }}"
      availability_topic: "opendtu/ac/is_valid"

Cette section sert à lier les valeurs du sensor dans HA à un topic MQTT. Votre sensor n'est pas disponible, sûrement car il n'arrive pas à trouver les données dans MQTT. Est-ce que vous avez le bon topic ? Dans OpenDTU, j'ai configuré mon prefix à: opendtu

@Saroumanefr
Copy link

Ok, j'ai compris. Dans opendtu le prefix était resté par défaut à : solar. J'ai modifié le yaml pour lui donner le bon chemin et effectivement ça fonctionne beaucoup mieux. Encore merci pour les explications.

@phil31
Copy link

phil31 commented Jan 29, 2024

bonjour Mathieu,

merci pour ton partage
je viens juste d'avoir mon openDTU et je m'attaque à la configuration avec HA (dont je suis novice ..)

est ce que dois mettre les 3 fichiers (energy, opendtu et view .yaml) dans le repertoire config/packages ?
lorsque je fais ca et que je vérifie la configuration yaml (outils de dev de HA), j'ai un erreur :

image

quelle betise je fais stp ?
merci !

@mathieucarbou
Copy link
Author

Ça peut être pas mal de chose...

  • problème d'indentation
  • problème de configuration
  • un mauvais caractère quelque part
  • etc.

@phil31
Copy link

phil31 commented Jan 29, 2024

merci pour ton rapide retour !
donc oui, tu confirmes que les 3 fichiers doivent etre dans le repertoire /config/packages ?

pour le fichier view.yaml qui pose probleme, j'ai simplement fait un copier coller raw ..
HA n'indique pas de probleme d'indentation
le seule message est le screencopy que j'ai joint

@mathieucarbou
Copy link
Author

Ah pardon!

Alors juste 2, et energy.yaml est à modifier selon tes propres capteurs.

la vue est la config du dashboard dans 3 petits points > modifier > éditer config

image
image

@phil31
Copy link

phil31 commented Jan 30, 2024

ok donc energy et opendtu .yaml dans le rep config/packages
energy.yaml a modifier avec mes parametres et MQTT ..

mais que faire du view.yaml ?
desolé cette question sort peut etre du sujet openDTU, mais novice, je ne sais pas quoi en faire, ou comment creer un Lovelace card
enfin pas certain de mon coup, faut il passer par le frontend , ajouter une carte, yaml lovelace .. coller le code dedans ?

a priori oui, mais je crois que je me retrouve dans le probleme du thread du Dec 3, 2023 .. et ton image en réponse n'est pas accessible !

merci !

@jerome553
Copy link

bonsoir, comment cela ce fait il que je n'arrive pas a connecter openDTU à HA?
j'ai fait refait tout le manuelle et ça ne eu toujours pas.
merci.

@crazybike63
Copy link

Bonjour, bravo pour votre travail !!! et merci pour le partage...
J'ai adapté votre code à mon installation et j'ai une petite question concernant la formule de calcule de "{{ [100, states.sensor.inverter_1_powerdc.state|float / (400 * (110 - states.sensor.inverter_1_temperature.state|float * 0.4) / 100) * 100] | min }}".
A quoi correspondent les nombres ?
Mon installation comporte des micron-onduleurs de puissances differentes ce qui m'obligera à adapter.

Merci de votre comprehension.

cordialement Christophe

@mathieucarbou
Copy link
Author

Bonjour, bravo pour votre travail !!! et merci pour le partage... J'ai adapté votre code à mon installation et j'ai une petite question concernant la formule de calcule de "{{ [100, states.sensor.inverter_1_powerdc.state|float / (400 * (110 - states.sensor.inverter_1_temperature.state|float * 0.4) / 100) * 100] | min }}". A quoi correspondent les nombres ? Mon installation comporte des micron-onduleurs de puissances differentes ce qui m'obligera à adapter.

Merci de votre comprehension.

cordialement Christophe

idéalement il faudrait templacer 0.4 et 400 selon la puissance de vos MO. C'est optionnel et peut être enlevé. Ça sert à calculer plus précisément l'irradiation.

L'irradiation est calculée par le DTU en prenant la puissance en sortie divisée par la puissance crete (400Wc), mais cette puissance est une mesure en labo à 25 degrés. Hors la puissance crete dépend de la température. Pour les panneaux DMEGC, chaque pas de +25 degrés entraine une baisse de 10% de la puissance crete à cause de la chaleur, et vis versa: hausse de 10% à 0 degrés.

Donc cela fausse le % d'irradiation car l'hiver, openDTU va rapporter un % d'irradiation plus élevé que la réalité, car la puissance crete est souvent plus que 400Wc, et l'été, il va rapporter un % plus bas, alors qu'en fait l'irradiation est à son maximum, mais il fait tellement chaud que les panneaux ne peuvent pas sortir plus que 360W.

@crazybike63
Copy link

Merci pour vos explications extrêmement claires. Je modifier mon code en conséquence.
Encore merci pour le partage, je vous souhaite un bon week-end.

Cordialement Christophe

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment