- 24V 400AH LFP
- 24V Fridge and Freezer
- 24V Multiplus 3000
- 24V Alternator
- 2+ 24/12-25 Orion DC-DC Converters
- Smart Solar 150/45
-
Does REC BMS that supports 24V also support Victron? Yes
-
Does Wakespeed 500 support 24V? Yes according to Nation's? Yes according to Nations and Wakespeed manual.
- MPPT is 3 kg and 4393750 mm^3 and ~$450 for 24V vs 4.5 kg and 6563160 mm^3 and $700 for 12V
- Alternator line temperature rise will be 1/4 of 12V for equivalent wire.
Similar/Equavalent Wire Comparisons:
12v to 24v Equivalent Voltage Drop % and Equal Loss for the Same Transmitted Power
V=IR. Because I has decreased by 1/2 and Vsource has increased by 2, to achive the same fraction of Vsource/Vdrop, Vdrop must also double. This implies R must increase by a factor of 4.
P = R*I2. I has decreased by a factor of 1/2, thus I2 has decreased by a factor of 1/4. This implies R must increase by a factor of 4.
4/0 becomes 2 AWG
2 AWG becomes 8 AWG
8 AWG becomes 14 AWG
12v to 24v Equivalent Ampacity for Same Power
4/0 becomes 2 AWG
2 AWG becomes 6 AWG
8 AWG becomes 14 AWG