Created
May 8, 2021 04:28
-
-
Save nevesenin/b875af76de99a287ff3834b988edcd4c to your computer and use it in GitHub Desktop.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
blueprint: | |
name: Target temperature adjustment depending on second temperature sensor (Fahrenheit) | |
description: > | |
Sets target temperature depending on second temperature sensor. | |
This blueprint is inspired by this blueprint https://community.home-assistant.io/t/tado-set-offset-using-separate-temperature-sensor/288515 | |
created by Sanderma. Since not all thermostat devices have an configurable | |
offset, this blueprint sets the target temperature of the thermostat device | |
depending on a given target temperature and a second temperature sensor. | |
domain: automation | |
input: | |
temperature_sensor: | |
name: Temperature sensor | |
description: This sensor will be used as the source. | |
selector: | |
entity: | |
domain: sensor | |
device_class: temperature | |
thermostat: | |
name: Thermostat | |
description: The thermostat to set target temperature | |
selector: | |
entity: | |
domain: climate | |
target_temperature: | |
name: Target temperature | |
description: Target temperature of the thermostat | |
selector: | |
number: | |
min: 45 | |
max: 95 | |
step: 1 | |
unit_of_measurement: "°F" | |
default: 70 | |
variables: | |
thermostat: !input thermostat | |
temperature_sensor: !input temperature_sensor | |
target_temperature: !input target_temperature | |
actual_temperature: "{{ states(temperature_sensor) | float }}" | |
calculated_adjustment: "{{ target_temperature - actual_temperature }}" | |
calculated_target_temperature: "{{ ( target_temperature + calculated_adjustment ) | round }}" | |
trigger: | |
- platform: state | |
entity_id: !input thermostat | |
attribute: "{{ current_temperature_attribute }}" | |
- platform: state | |
entity_id: !input temperature_sensor | |
condition: "{{ calculated_adjustment != 0 }}" | |
action: | |
- service: system_log.write | |
data: | |
message: > | |
{{ thermostat }} has temp difference of {{ calculated_adjustment }}. Setting target temperature to {{ calculated_target_temperature }} | |
level: info | |
logger: blueprints.nevesenin.target_temperature_adjustment_fahrenheit | |
- service: system_log.write | |
data: | |
message: > | |
thermostat: {{ thermostat }}, | |
temperature_sensor: {{ temperature_sensor }}, | |
target_temperature: {{ target_temperature }}, | |
actual_temperature: {{ actual_temperature }}, | |
calculated_adjustment: {{ calculated_adjustment }}, | |
calculated_target_temperature: {{ calculated_target_temperature }} | |
level: debug | |
logger: blueprints.nevesenin.target_temperature_adjustment_fahrenheit | |
- service: climate.set_temperature | |
data: | |
temperature: "{{ calculated_target_temperature }}" | |
entity_id: "{{ thermostat }}" | |
mode: single |