Skip to content

Instantly share code, notes, and snippets.

@noone2k
Last active December 25, 2023 21:45
Show Gist options
  • Save noone2k/0b3a116a6f35286abef7199b62a0777a to your computer and use it in GitHub Desktop.
Save noone2k/0b3a116a6f35286abef7199b62a0777a to your computer and use it in GitHub Desktop.
quick and dirty hoymles grid profile parser
#!/usr/bin/python3
#
# hoymiles grid profile parser
# quick and dirty
# dyn table/version
#
# param 1: grid profile
# f.ex. python3 _hgp_qd.py 0a002001000c08fc07a3000f09e2001e064a00140a5500140ac8000a09e21003138812c0001413ec0014128e000514500005200000013003025809e207a3139c1356400007d0001050010001139c0190001000006000000109e20a5a021580010000085b012c08b70941099d012c006490000000005fb000000001f4005f700200012710a00200000000cbfe00
#
import sys
hex_string = sys.argv[1]
table_types={ 0x00: "Voltage (H/LVRT)", 0x10: "Frequency (H/LFRT)", 0x20: "Island Detection (ID)", 0x30: "Reconnection (RT)", 0x40:"Ramp Rates (RR)", 0x50: "Frequency Watt (FW)", 0x60: "Volt Watt (VW)", 0x70: "Active Power Control (APC)", 0x80:"Volt Var (VV)", 0x90: "Specified Power Factor (SPF)", 0xA0: "Reactive Power Control (RPC)", 0xB0: "Watt Power Factor (WPF)" }
### country / regulations or simple internal DB ID ? ;)
# 02 00 - austria ???? ( empty list ) / IEEE 1547 240V (?)
# 03 00 - germany - DE_VDE4105_2018 (2.0.x)
# 03 01 - unknown
# 0a 00 - European - EN 50549-1:2019
# 0c 00 - Austria - 2.0.x EU_EN50438
# 0d 04 - france - ???
# 12 00 - Poland - 2.0.x (EU_EN50438)
# 37 00 - swiss - 2.0.x (CH_NA EEA-NE7–CH2020)
table_regs={
0x02: { 0x00: "US - IEEE 1547 240V (?)"},
0x03: { 0x00: "Germany - DE_VDE4105_2018"},
0x0a: { 0x00: "European - EN 50549-1:2019"},
0x0c: { 0x00: "AT Tor - EU_EN50438" },
0x0d: { 0x04: "France" },
0x12: { 0x00: "Poland - EU_EN50438" },
0x37: { 0x00: "Swiss - CH_NA EEA-NE7-CH2020"},
}
### { table_nr : { table_ver: [["name","unit",divider]] }}
tables_struct = {
0x00 : {
# Germany - DE_VDE4105_2018
0x0A: [
["Nominale Voltage (NV)","V",10],
["Low Voltage 1 (LV1)","V",10],
["LV1 Maximum Trip Time (MTT)","s",10],
["High Voltage 1 (HV1)","V",10],
["HV1 Maximum Trip Time (MTT)","s",10],
["Low Voltage 2 (LV2)","V",10],
["LV2 Maximum Trip Time (MTT)","s",10],
["10mins Average High Voltage (AHV)","V",10]
],
# AT Tor - EU_EN50438
0x0B: [
["Nominale Voltage (NV)","V",10],
["Low Voltage 1 (LV1)","V",10],
["LV1 Maximum Trip Time (MTT)","s",10],
["High Voltage 1 (HV1)","V",10],
["HV1 Maximum Trip Time (MTT)","s",10],
["Low Voltage 2 (LV2)","V",10],
["LV2 Maximum Trip Time (MTT)","s",10],
["High Voltage 2 (HV2)","V",10],
["HV2 Maximum Trip Time (MTT)","s",10],
["10mins Average High Voltage (AHV)","V",10]
],
# Poland - EU_EN50438
0x00: [
["Nominale Voltage (NV)","V",10],
["Low Voltage 1 (LV1)","V",10],
["LV1 Maximum Trip Time (MTT)","s",10],
["High Voltage 1 (HV1)","V",10],
["HV1 Maximum Trip Time (MTT)","s",10],
],
# Swiss - CH_NA EEA-NE7-CH2020
0x03: [
["Nominale Voltage (NV)","V",10],
["Low Voltage 1 (LV1)","V",10],
["LV1 Maximum Trip Time (MTT)","s",10],
["High Voltage 1 (HV1)","V",10],
["HV1 Maximum Trip Time (MTT)","s",10],
["Low Voltage 2 (LV2)","V",10],
["LV2 Maximum Trip Time (MTT)","s",10],
["High Voltage 2 (HV2)","V",10],
["HV2 Maximum Trip Time (MTT)","s",10],
],
# European - EN 50549-1:2019
0x0C: [
["Nominale Voltage (NV)","V",10],
["Low Voltage 1 (LV1)","V",10],
["LV1 Maximum Trip Time (MTT)","s",10],
["High Voltage 1 (HV1)","V",10],
["HV1 Maximum Trip Time (MTT)","s",10],
["Low Voltage 2 (LV2)","V",10],
["LV2 Maximum Trip Time (MTT)","s",10],
["High Voltage 2 (HV2)","V",10],
["HV2 Maximum Trip Time (MTT)","s",10],
["High Voltage 3 (HV3)","V",10],
["HV3 Maximum Trip Time (MTT)","s",10],
["10mins Average High Voltage (AHV)","V",10],
],
# unknown 03 01
0x08: [
["Nominale Voltage (NV)","V",10],
["Low Voltage 1 (LV1)","V",10],
["LV1 Maximum Trip Time (MTT)","s",10],
["High Voltage 1 (HV1)","V",10],
["HV1 Maximum Trip Time (MTT)","s",10],
["? High Voltage 2 (HV2)","V",10],
],
# IEEE 1547 240V (?)
0x35: [
["Nominale Voltage (NV)","V",10],
["Low Voltage 1 (LV1)","V",10],
["LV1 Maximum Trip Time (MTT)","s",10],
["High Voltage 1 (HV1)","V",10],
["HV1 Maximum Trip Time (MTT)","s",10],
["Low Voltage 2 (LV2)","V",10],
["LV2 Maximum Trip Time (MTT)","s",10],
["High Voltage 2 (HV2)","V",10],
["HV2 Maximum Trip Time (MTT)","s",10],
["?","",1],
["?","",1],
["?","",1],
["?","",1],
]
},
0x10: {
0x00: [
["Nominal Frequency","Hz",100],
["Low Frequency 1 (LF1)","Hz",100],
["LF1 Maximum Trip Time (MTT)","s",10],
["High Frequency 1 (HF1)","Hz",100],
["HF1 Maximum Trip time (MTT)","s",10]
],
0x03: [
["Nominal Frequency","Hz",100],
["Low Frequency 1 (LF1)","Hz",100],
["LF1 Maximum Trip Time (MTT)","s",10],
["High Frequency 1 (HF1)","Hz",100],
["HF1 Maximum Trip time (MTT)","s",10],
["Low Frequency 2 (LF2)","Hz",100],
["LF2 Maximum Trip Time (MTT)","s",10],
["High Frequency 2 (HF2)","Hz",100],
["HF2 Maximum Trip time (MTT)","s",10],
]
},
0x20: { 0x00: [ ["ID Function Activated","bool",1]] },
0x30: {
0x03: [
["Reconnect Time (RT)","s",10],
["Reconnect High Voltage (RHV)","V",10],
["Reconnect Low Voltage (RLV)","V",10],
["Reconnect High Frequency (RHF)","Hz",100],
["Reconnect Low Frequency (RLF)","Hz",100]
],
0x07: [
["Reconnect Time (RT)","s",10],
["Reconnect High Voltage (RHV)","V",10],
["Reconnect Low Voltage (RLV)","V",10],
["Reconnect High Frequency (RHF)","Hz",100],
["Reconnect Low Frequency (RLF)","Hz",100],
[" ??? ","?",1],
[" ??? ","?",1],
],
},
0x40: { 0x00: [
["Normal Ramp up Rate(RUR_NM)","Rated%/s",100],
["Soft Start Ramp up Rate (RUR_SS)","Rated%/s",100]
],
},
0x50: { 0x08: [
["FW Function Activated","bool",1],
["Start of Frequency Watt Droop (Fstart)","Hz",100],
["FW Droop Slope (Kpower_Freq)","Pn%/Hz",10],
["Recovery Ramp Rate (RRR)","Pn%/s",100],
["Recovery High Frequency (RVHF)","Hz",100],
["Recovery Low Frequency (RVLF)","Hz",100]
],
0x00: [
["FW Function Activated","bool",1],
["Start of Frequency Watt Droop (Fstart)","Hz",100],
["FW Droop Slope (Kpower_Freq)","Pn%/Hz",10],
["Recovery Ramp Rate (RRR)","Pn%/s",100],
],
0x01: [
["FW Function Activated","bool",1],
["Start of Frequency Watt Droop (Fstart)","Hz",100],
["FW Droop Slope (Kpower_Freq)","Pn%/Hz",10],
["Recovery Ramp Rate (RRR)","Pn%/s",100],
["Recovery High Frequency (RVHF)","Hz",100],
],
# ieee
0x11: [
["FW Function Activated","bool",1],
["Start of Frequency Watt Droop (Fstart)","Hz",100],
["FW Droop Slope (Kpower_Freq)","Pn%/Hz",10],
["Recovery Ramp Rate (RRR)","Pn%/s",100],
["Recovery High Frequency (RVHF)","Hz",100],
],
},
0x60: { 0x00: [
["VW Function Activated","bool",1],
["Start of Voltage Watt Droop (Vstart)","V",10],
["End of Voltage Watt Droop (Vend)","V",10],
["Droop Slope (Kpower_Volt)","Pn%/V",100]
],
0x04: [
["VW Function Activated","bool",1],
["Start of Voltage Watt Droop (Vstart)","V",10],
["End of Voltage Watt Droop (Vend)","V",10],
["Droop Slope (Kpower_Volt)","Pn%/V",100]
],
},
0x70: { 0x02: [
["APC Function Activated","bool",1],
["Power Ramp Rate (PRR)","Pn%/s",100]
],
0x00: [
["APC Function Activated","bool",1]
]
},
0x80: { 0x00: [
["VV Function Activated","bool",1],
["Voltage Set Point V1","V",10],
["Reactive Set Point Q1","%Pn",10],
["Voltage Set Point V2","V",10],
["Voltage Set Point V3","V",10],
["Voltage Set Point V4","V",10],
["Reactive Set Point Q4","%Pn",10]
],
0x01: [
["VV Function Activated","bool",1],
["Voltage Set Point V1","V",10],
["Reactive Set Point Q1","%Pn",10],
["Voltage Set Point V2","V",10],
["Voltage Set Point V3","V",10],
["Voltage Set Point V4","V",10],
["Reactive Set Point Q4","%Pn",10],
["Setting Time (Tr)","s",10]
],
},
0x90: { 0x00: [
["SPF Function Activated","bool",1],
["Power Factor (PF)","",100]
]
},
0xA0: { 0x02: [
["RPC Function Activated","bool",1],
["Reactive Power (VAR)","%Sn",1]
]
},
0xB0: { 0x00: [
["WPF Function Activated","bool",1],
["Start of Power of WPF (Pstart)","%Pn",10],
["Power Factor ar Rated Power (PFRP)","",100]
]
}
}
def modbusCrc(msg:str) -> int:
crc = 0xFFFF
for n in range(len(msg)):
crc ^= msg[n]
for i in range(8):
if crc & 1:
crc >>= 1
crc ^= 0xA001
else:
crc >>= 1
return crc
binary_string = bytes.fromhex(hex_string)
binary_length = len(binary_string)
### internal DB ID ( country/regulations ) ???
str_header1 = binary_string[0]
str_header2 = binary_string[1]
### version ( major.minor / rev ) ???
str_version1 = binary_string[2]
str_version2 = binary_string[3]
try:
print("Grid Profile: %s " % (table_regs[str_header1][str_header2]))
except:
print("Grid Profile: unknown ( plz report to https://github.com/tbnobody/OpenDTU/wiki/Grid-Profile-Parser )" )
print ("Version: %s.%s.%s" % (((str_version1 >> 4) & 0x0F),(str_version1 & 0x0F),str_version2))
position=4
while (position < binary_length):
str_table_n = binary_string[position]
str_table_v = binary_string[position+1]
try:
print("Table Type: " , table_types[str_table_n])
except:
pass
try:
tables_diz=tables_struct[str_table_n][str_table_v]
table_length = len(tables_diz)
except:
crc=bytearray(binary_string[position:position+2]).hex()
crc2 = modbusCrc(binary_string[0:position])
crcc = crc2.to_bytes(2, byteorder='big').hex()
if crc == crcc:
print("CRC (ok): ",crcc)
else:
print("CRC (?): ",crc)
print("CRC calced: %s " % (crcc))
print(" - possible unknown table (module), plz report to https://github.com/tbnobody/OpenDTU/wiki/Grid-Profile-Parser")
print("end")
break
table_pos=0
#print("str_table_n: %s, str_table_v: %s, table_length: %s" % (str_table_n,str_table_v,table_length))
position += 2
for x in range(table_length):
try:
table_diz=tables_diz[table_pos]
except:
table_diz=["","",1]
table_pos += 1
str_work = binary_string[position:position+2]
str_hex = str_work.hex()
str_int = int(str_hex,16)
str_val = str_int / table_diz[2]
print("position: %s \t: %s \t %s \t %s\t[%s]\t\t[%s]" % (position,str_hex,str_int,str_val,table_diz[1],table_diz[0]))
position += 2
@noone2k
Copy link
Author

noone2k commented Oct 23, 2023

example output from all submitted UNIQUE examples ( only 12 are unique, the rest ( > 90) are dupes )
the "02 00 ....." has an empty buffer ( maybe erroneous or not yet populated, query to soon ??? )
didn't look further in the first 4 bytes, but guessing region/regulation(1-2)/version (3-4) or something along the lines ...


*  020000015cc0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
CRC (?):  b'5cc0'
end
*  03002000000a08fc0730001e0b3b0001040b001e09e210001388128e0001141e0001200000013003025809e207a31392128e400007d003e850080001139c0190001001f6137470020001271080000000085b012c08b70941099d012c90000000005fb000000001f4005fa00200000000ab2a000000000000000000000000000000000000000000000000000000
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'0730' 	 1840 	 184.0  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'001e' 	 30 	 3.0  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'0b3b' 	 2875 	 287.5  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'0001' 	 1 	 0.1  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'040b' 	 1035 	 103.5  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'001e' 	 30 	 0.3  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'09e2' 	 2530 	 253.0  [V] 	 [10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 24 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 26 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF1)]
position: 28 	: b'0001' 	 1 	 0.1  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 30 	: b'141e' 	 5150 	 51.5  [Hz] 	 [High Frequency 1 (HF1)]
position: 32 	: b'0001' 	 1 	 0.1  [s] 	 [HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 36 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 40 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 42 	: b'09e2' 	 2530 	 253.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 44 	: b'07a3' 	 1955 	 195.5  [V] 	 [Reconnect Low Voltage (RLV)]
position: 46 	: b'1392' 	 5010 	 50.1  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 48 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 52 	: b'07d0' 	 2000 	 20.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 54 	: b'03e8' 	 1000 	 10.0  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 58 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 60 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 62 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 64 	: b'0010' 	 16 	 0.16  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
position: 66 	: b'01f6' 	 502 	 5.02  [Hz] 	 [Recovery High Frequency (RVHF)]
position: 68 	: b'1374' 	 4980 	 49.8  [Hz] 	 [Recovery Low Frequency (RVLF)]
Table Type:  Active Power Control (APC)
position: 72 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 74 	: b'2710' 	 10000 	 1.0  [Pn%/s] 	 [Power Ramp Rate (PRR)]
Table Type:  Volt Var (VV)
position: 78 	: b'0000' 	 0 	 0.0  [bool] 	 [VV Function Activated]
position: 80 	: b'085b' 	 2139 	 213.9  [V] 	 [Voltage Set Point V1]
position: 82 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q1]
position: 84 	: b'08b7' 	 2231 	 223.1  [V] 	 [Voltage Set Point V2]
position: 86 	: b'0941' 	 2369 	 236.9  [V] 	 [Voltage Set Point V3]
position: 88 	: b'099d' 	 2461 	 246.1  [V] 	 [Voltage Set Point V4]
position: 90 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q4]
Table Type:  Specified Power Factor (SPF)
position: 94 	: b'0000' 	 0 	 0.0  [bool] 	 [SPF Function Activated]
position: 96 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 100 	: b'0000' 	 0 	 0.0  [bool] 	 [WPF Function Activated]
position: 102 	: b'01f4' 	 500 	 50.0  [%Pn] 	 [Start of Power of WPF (Pstart)]
position: 104 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor ar Rated Power (PFRP)]
Table Type:  Reactive Power Control (RPC)
position: 108 	: b'0000' 	 0 	 0.0  [bool] 	 [RPC Function Activated]
position: 110 	: b'0000' 	 0 	 0.0  [%Sn] 	 [Reactive Power (VAR)]
CRC (?):  b'ab2a'
end
*  03002000000a08fc0730001e0b3b0001040b001e09e210001388128e0001141e000120000001300302580ac807a31392128e400007d003e850080001139c0190001001f6137470020001271080000000085b012c08b70941099d012c90000000005fb000000001f4005fa002000000006c58000000000000000000000000000000000000000000000000000000
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'0730' 	 1840 	 184.0  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'001e' 	 30 	 3.0  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'0b3b' 	 2875 	 287.5  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'0001' 	 1 	 0.1  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'040b' 	 1035 	 103.5  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'001e' 	 30 	 0.3  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'09e2' 	 2530 	 253.0  [V] 	 [10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 24 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 26 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF1)]
position: 28 	: b'0001' 	 1 	 0.1  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 30 	: b'141e' 	 5150 	 51.5  [Hz] 	 [High Frequency 1 (HF1)]
position: 32 	: b'0001' 	 1 	 0.1  [s] 	 [HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 36 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 40 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 42 	: b'0ac8' 	 2760 	 276.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 44 	: b'07a3' 	 1955 	 195.5  [V] 	 [Reconnect Low Voltage (RLV)]
position: 46 	: b'1392' 	 5010 	 50.1  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 48 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 52 	: b'07d0' 	 2000 	 20.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 54 	: b'03e8' 	 1000 	 10.0  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 58 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 60 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 62 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 64 	: b'0010' 	 16 	 0.16  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
position: 66 	: b'01f6' 	 502 	 5.02  [Hz] 	 [Recovery High Frequency (RVHF)]
position: 68 	: b'1374' 	 4980 	 49.8  [Hz] 	 [Recovery Low Frequency (RVLF)]
Table Type:  Active Power Control (APC)
position: 72 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 74 	: b'2710' 	 10000 	 1.0  [Pn%/s] 	 [Power Ramp Rate (PRR)]
Table Type:  Volt Var (VV)
position: 78 	: b'0000' 	 0 	 0.0  [bool] 	 [VV Function Activated]
position: 80 	: b'085b' 	 2139 	 213.9  [V] 	 [Voltage Set Point V1]
position: 82 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q1]
position: 84 	: b'08b7' 	 2231 	 223.1  [V] 	 [Voltage Set Point V2]
position: 86 	: b'0941' 	 2369 	 236.9  [V] 	 [Voltage Set Point V3]
position: 88 	: b'099d' 	 2461 	 246.1  [V] 	 [Voltage Set Point V4]
position: 90 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q4]
Table Type:  Specified Power Factor (SPF)
position: 94 	: b'0000' 	 0 	 0.0  [bool] 	 [SPF Function Activated]
position: 96 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 100 	: b'0000' 	 0 	 0.0  [bool] 	 [WPF Function Activated]
position: 102 	: b'01f4' 	 500 	 50.0  [%Pn] 	 [Start of Power of WPF (Pstart)]
position: 104 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor ar Rated Power (PFRP)]
Table Type:  Reactive Power Control (RPC)
position: 108 	: b'0000' 	 0 	 0.0  [bool] 	 [RPC Function Activated]
position: 110 	: b'0000' 	 0 	 0.0  [%Sn] 	 [Reactive Power (VAR)]
CRC (?):  b'6c58'
end
*  03002000000a08fc0730001e0b3b0001040b001e09e210001388128e0001141e000120000001300302580ac807a31392128e400007d003e850080001139c0190001001f6137470020001271080000000085b012c08b70941099d012c90000000ffa1b000000001f4005fa002000000009c27000000000000000000000000000000000000000000000000000000
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'0730' 	 1840 	 184.0  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'001e' 	 30 	 3.0  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'0b3b' 	 2875 	 287.5  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'0001' 	 1 	 0.1  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'040b' 	 1035 	 103.5  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'001e' 	 30 	 0.3  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'09e2' 	 2530 	 253.0  [V] 	 [10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 24 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 26 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF1)]
position: 28 	: b'0001' 	 1 	 0.1  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 30 	: b'141e' 	 5150 	 51.5  [Hz] 	 [High Frequency 1 (HF1)]
position: 32 	: b'0001' 	 1 	 0.1  [s] 	 [HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 36 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 40 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 42 	: b'0ac8' 	 2760 	 276.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 44 	: b'07a3' 	 1955 	 195.5  [V] 	 [Reconnect Low Voltage (RLV)]
position: 46 	: b'1392' 	 5010 	 50.1  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 48 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 52 	: b'07d0' 	 2000 	 20.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 54 	: b'03e8' 	 1000 	 10.0  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 58 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 60 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 62 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 64 	: b'0010' 	 16 	 0.16  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
position: 66 	: b'01f6' 	 502 	 5.02  [Hz] 	 [Recovery High Frequency (RVHF)]
position: 68 	: b'1374' 	 4980 	 49.8  [Hz] 	 [Recovery Low Frequency (RVLF)]
Table Type:  Active Power Control (APC)
position: 72 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 74 	: b'2710' 	 10000 	 1.0  [Pn%/s] 	 [Power Ramp Rate (PRR)]
Table Type:  Volt Var (VV)
position: 78 	: b'0000' 	 0 	 0.0  [bool] 	 [VV Function Activated]
position: 80 	: b'085b' 	 2139 	 213.9  [V] 	 [Voltage Set Point V1]
position: 82 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q1]
position: 84 	: b'08b7' 	 2231 	 223.1  [V] 	 [Voltage Set Point V2]
position: 86 	: b'0941' 	 2369 	 236.9  [V] 	 [Voltage Set Point V3]
position: 88 	: b'099d' 	 2461 	 246.1  [V] 	 [Voltage Set Point V4]
position: 90 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q4]
Table Type:  Specified Power Factor (SPF)
position: 94 	: b'0000' 	 0 	 0.0  [bool] 	 [SPF Function Activated]
position: 96 	: b'ffa1' 	 65441 	 654.41  [] 	 [Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 100 	: b'0000' 	 0 	 0.0  [bool] 	 [WPF Function Activated]
position: 102 	: b'01f4' 	 500 	 50.0  [%Pn] 	 [Start of Power of WPF (Pstart)]
position: 104 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor ar Rated Power (PFRP)]
Table Type:  Reactive Power Control (RPC)
position: 108 	: b'0000' 	 0 	 0.0  [bool] 	 [RPC Function Activated]
position: 110 	: b'0000' 	 0 	 0.0  [%Sn] 	 [Reactive Power (VAR)]
CRC (?):  b'9c27'
end
*  03002001000a08fc0730001e0b3b0001040b001e09e210001388128e0001141e0001200000013003025809e207a31392128e400007d0001050080001139c0190001001f6137470020001271080000000085b012c08b70941099d012c90000000005fb000000001f4005fa00200000000ce67000000000000000000000000000000000000000000000000000000
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'0730' 	 1840 	 184.0  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'001e' 	 30 	 3.0  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'0b3b' 	 2875 	 287.5  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'0001' 	 1 	 0.1  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'040b' 	 1035 	 103.5  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'001e' 	 30 	 0.3  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'09e2' 	 2530 	 253.0  [V] 	 [10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 24 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 26 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF1)]
position: 28 	: b'0001' 	 1 	 0.1  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 30 	: b'141e' 	 5150 	 51.5  [Hz] 	 [High Frequency 1 (HF1)]
position: 32 	: b'0001' 	 1 	 0.1  [s] 	 [HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 36 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 40 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 42 	: b'09e2' 	 2530 	 253.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 44 	: b'07a3' 	 1955 	 195.5  [V] 	 [Reconnect Low Voltage (RLV)]
position: 46 	: b'1392' 	 5010 	 50.1  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 48 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 52 	: b'07d0' 	 2000 	 20.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 54 	: b'0010' 	 16 	 0.16  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 58 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 60 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 62 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 64 	: b'0010' 	 16 	 0.16  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
position: 66 	: b'01f6' 	 502 	 5.02  [Hz] 	 [Recovery High Frequency (RVHF)]
position: 68 	: b'1374' 	 4980 	 49.8  [Hz] 	 [Recovery Low Frequency (RVLF)]
Table Type:  Active Power Control (APC)
position: 72 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 74 	: b'2710' 	 10000 	 1.0  [Pn%/s] 	 [Power Ramp Rate (PRR)]
Table Type:  Volt Var (VV)
position: 78 	: b'0000' 	 0 	 0.0  [bool] 	 [VV Function Activated]
position: 80 	: b'085b' 	 2139 	 213.9  [V] 	 [Voltage Set Point V1]
position: 82 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q1]
position: 84 	: b'08b7' 	 2231 	 223.1  [V] 	 [Voltage Set Point V2]
position: 86 	: b'0941' 	 2369 	 236.9  [V] 	 [Voltage Set Point V3]
position: 88 	: b'099d' 	 2461 	 246.1  [V] 	 [Voltage Set Point V4]
position: 90 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q4]
Table Type:  Specified Power Factor (SPF)
position: 94 	: b'0000' 	 0 	 0.0  [bool] 	 [SPF Function Activated]
position: 96 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 100 	: b'0000' 	 0 	 0.0  [bool] 	 [WPF Function Activated]
position: 102 	: b'01f4' 	 500 	 50.0  [%Pn] 	 [Start of Power of WPF (Pstart)]
position: 104 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor ar Rated Power (PFRP)]
Table Type:  Reactive Power Control (RPC)
position: 108 	: b'0000' 	 0 	 0.0  [bool] 	 [RPC Function Activated]
position: 110 	: b'0000' 	 0 	 0.0  [%Sn] 	 [Reactive Power (VAR)]
CRC (?):  b'ce67'
end
*  0a002000000c08fc07a3000f09e2001e064a00140a5500140ac8000a09e21003138812c0001413ec0014128e000514500005200000013003025809e207a3139c1356400007d0001050010001139c0190001000006000000109e20a5a021580010000085b012c08b70941099d012c006490000000005fb000000001f4005f700200010032a002000000006bb200
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'07a3' 	 1955 	 195.5  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'000f' 	 15 	 1.5  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'09e2' 	 2530 	 253.0  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'001e' 	 30 	 3.0  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'064a' 	 1610 	 161.0  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'0014' 	 20 	 0.2  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'0a55' 	 2645 	 264.5  [V] 	 [High Voltage 2 (HV2)]
position: 22 	: b'0014' 	 20 	 2.0  [s] 	 [HV2 Maximum Trip Time (MTT)]
position: 24 	: b'0ac8' 	 2760 	 276.0  [V] 	 [High Voltage 3 (HV3)]
position: 26 	: b'000a' 	 10 	 0.1  [s] 	 [HV3 Maximum Trip Time (MTT)]
position: 28 	: b'09e2' 	 2530 	 253.0  [V] 	 [10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 32 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 34 	: b'12c0' 	 4800 	 48.0  [Hz] 	 [Low Frequency 1 (LF1)]
position: 36 	: b'0014' 	 20 	 2.0  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 38 	: b'13ec' 	 5100 	 51.0  [Hz] 	 [High Frequency 1 (HF1)]
position: 40 	: b'0014' 	 20 	 2.0  [s] 	 [HF1 Maximum Trip time (MTT)]
position: 42 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF2)]
position: 44 	: b'0005' 	 5 	 0.5  [s] 	 [LF2 Maximum Trip Time (MTT)]
position: 46 	: b'1450' 	 5200 	 52.0  [Hz] 	 [High Frequency 1 (HF2)]
position: 48 	: b'0005' 	 5 	 0.5  [s] 	 [HF2 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 52 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 56 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 58 	: b'09e2' 	 2530 	 253.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 60 	: b'07a3' 	 1955 	 195.5  [V] 	 [Reconnect Low Voltage (RLV)]
position: 62 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 64 	: b'1356' 	 4950 	 49.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 68 	: b'07d0' 	 2000 	 20.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 70 	: b'0010' 	 16 	 0.16  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 74 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 76 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 78 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 80 	: b'0010' 	 16 	 0.16  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
position: 82 	: b'0000' 	 0 	 0.0  [Hz] 	 [Recovery High Frequency (RVHF)]
Table Type:  Volt Watt (VW)
position: 86 	: b'0001' 	 1 	 1.0  [bool] 	 [VW Function Activated]
position: 88 	: b'09e2' 	 2530 	 253.0  [V] 	 [Start of Voltage Watt Droop (Vstart)]
position: 90 	: b'0a5a' 	 2650 	 265.0  [V] 	 [End of Voltage Watt Droop (Vend)]
position: 92 	: b'0215' 	 533 	 5.33  [Pn%/V] 	 [Droop Slope (Kpower_Volt)]
Table Type:  Volt Var (VV)
position: 96 	: b'0000' 	 0 	 0.0  [bool] 	 [VV Function Activated]
position: 98 	: b'085b' 	 2139 	 213.9  [V] 	 [Voltage Set Point V1]
position: 100 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q1]
position: 102 	: b'08b7' 	 2231 	 223.1  [V] 	 [Voltage Set Point V2]
position: 104 	: b'0941' 	 2369 	 236.9  [V] 	 [Voltage Set Point V3]
position: 106 	: b'099d' 	 2461 	 246.1  [V] 	 [Voltage Set Point V4]
position: 108 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q4]
position: 110 	: b'0064' 	 100 	 10.0  [s] 	 [Setting Time (Tr)]
Table Type:  Specified Power Factor (SPF)
position: 114 	: b'0000' 	 0 	 0.0  [bool] 	 [SPF Function Activated]
position: 116 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 120 	: b'0000' 	 0 	 0.0  [bool] 	 [WPF Function Activated]
position: 122 	: b'01f4' 	 500 	 50.0  [%Pn] 	 [Start of Power of WPF (Pstart)]
position: 124 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor ar Rated Power (PFRP)]
Table Type:  Active Power Control (APC)
position: 128 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 130 	: b'0032' 	 50 	 0.005  [Pn%/s] 	 [Power Ramp Rate (PRR)]
Table Type:  Reactive Power Control (RPC)
position: 134 	: b'0000' 	 0 	 0.0  [bool] 	 [RPC Function Activated]
position: 136 	: b'0000' 	 0 	 0.0  [%Sn] 	 [Reactive Power (VAR)]
CRC (?):  b'6bb2'
end
*  0a002001000c08fc07a3000f09e2001e064a00140a5500140ac8000a09e21003138812c0001413ec0014128e000514500005200000013003025809e207a3139c1356400007d0001050010001139c0190001000006000000109e20a5a021580010000085b012c08b70941099d012c006490000000005fb000000001f4005f700200012710a00200000000cbfe00
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'07a3' 	 1955 	 195.5  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'000f' 	 15 	 1.5  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'09e2' 	 2530 	 253.0  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'001e' 	 30 	 3.0  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'064a' 	 1610 	 161.0  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'0014' 	 20 	 0.2  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'0a55' 	 2645 	 264.5  [V] 	 [High Voltage 2 (HV2)]
position: 22 	: b'0014' 	 20 	 2.0  [s] 	 [HV2 Maximum Trip Time (MTT)]
position: 24 	: b'0ac8' 	 2760 	 276.0  [V] 	 [High Voltage 3 (HV3)]
position: 26 	: b'000a' 	 10 	 0.1  [s] 	 [HV3 Maximum Trip Time (MTT)]
position: 28 	: b'09e2' 	 2530 	 253.0  [V] 	 [10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 32 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 34 	: b'12c0' 	 4800 	 48.0  [Hz] 	 [Low Frequency 1 (LF1)]
position: 36 	: b'0014' 	 20 	 2.0  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 38 	: b'13ec' 	 5100 	 51.0  [Hz] 	 [High Frequency 1 (HF1)]
position: 40 	: b'0014' 	 20 	 2.0  [s] 	 [HF1 Maximum Trip time (MTT)]
position: 42 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF2)]
position: 44 	: b'0005' 	 5 	 0.5  [s] 	 [LF2 Maximum Trip Time (MTT)]
position: 46 	: b'1450' 	 5200 	 52.0  [Hz] 	 [High Frequency 1 (HF2)]
position: 48 	: b'0005' 	 5 	 0.5  [s] 	 [HF2 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 52 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 56 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 58 	: b'09e2' 	 2530 	 253.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 60 	: b'07a3' 	 1955 	 195.5  [V] 	 [Reconnect Low Voltage (RLV)]
position: 62 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 64 	: b'1356' 	 4950 	 49.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 68 	: b'07d0' 	 2000 	 20.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 70 	: b'0010' 	 16 	 0.16  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 74 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 76 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 78 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 80 	: b'0010' 	 16 	 0.16  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
position: 82 	: b'0000' 	 0 	 0.0  [Hz] 	 [Recovery High Frequency (RVHF)]
Table Type:  Volt Watt (VW)
position: 86 	: b'0001' 	 1 	 1.0  [bool] 	 [VW Function Activated]
position: 88 	: b'09e2' 	 2530 	 253.0  [V] 	 [Start of Voltage Watt Droop (Vstart)]
position: 90 	: b'0a5a' 	 2650 	 265.0  [V] 	 [End of Voltage Watt Droop (Vend)]
position: 92 	: b'0215' 	 533 	 5.33  [Pn%/V] 	 [Droop Slope (Kpower_Volt)]
Table Type:  Volt Var (VV)
position: 96 	: b'0000' 	 0 	 0.0  [bool] 	 [VV Function Activated]
position: 98 	: b'085b' 	 2139 	 213.9  [V] 	 [Voltage Set Point V1]
position: 100 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q1]
position: 102 	: b'08b7' 	 2231 	 223.1  [V] 	 [Voltage Set Point V2]
position: 104 	: b'0941' 	 2369 	 236.9  [V] 	 [Voltage Set Point V3]
position: 106 	: b'099d' 	 2461 	 246.1  [V] 	 [Voltage Set Point V4]
position: 108 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q4]
position: 110 	: b'0064' 	 100 	 10.0  [s] 	 [Setting Time (Tr)]
Table Type:  Specified Power Factor (SPF)
position: 114 	: b'0000' 	 0 	 0.0  [bool] 	 [SPF Function Activated]
position: 116 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 120 	: b'0000' 	 0 	 0.0  [bool] 	 [WPF Function Activated]
position: 122 	: b'01f4' 	 500 	 50.0  [%Pn] 	 [Start of Power of WPF (Pstart)]
position: 124 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor ar Rated Power (PFRP)]
Table Type:  Active Power Control (APC)
position: 128 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 130 	: b'2710' 	 10000 	 1.0  [Pn%/s] 	 [Power Ramp Rate (PRR)]
Table Type:  Reactive Power Control (RPC)
position: 134 	: b'0000' 	 0 	 0.0  [bool] 	 [RPC Function Activated]
position: 136 	: b'0000' 	 0 	 0.0  [%Sn] 	 [Reactive Power (VAR)]
CRC (?):  b'cbfe'
end
*  0c002000000b08fc0730000f09f90001023f00320a55000809f910001388128e0001141e0001200000013003025809cb07a31392128e400007d0001050000001139c019000326004000109e20a10087e800000000844012c08a0096f09b4012c90000000005fb000000001f4005f700200012710a002000000006e8b0000000000000000000000000000000000
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'0730' 	 1840 	 184.0  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'000f' 	 15 	 1.5  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'09f9' 	 2553 	 255.3  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'0001' 	 1 	 0.1  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'023f' 	 575 	 57.5  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'0032' 	 50 	 0.5  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'0a55' 	 2645 	 264.5  [V] 	 [High Voltage 2 (HV2)]
position: 22 	: b'0008' 	 8 	 0.8  [s] 	 [HV2 Maximum Trip Time (MTT)]
position: 24 	: b'09f9' 	 2553 	 255.3  [V] 	 [10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 28 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 30 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF1)]
position: 32 	: b'0001' 	 1 	 0.1  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 34 	: b'141e' 	 5150 	 51.5  [Hz] 	 [High Frequency 1 (HF1)]
position: 36 	: b'0001' 	 1 	 0.1  [s] 	 [HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 40 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 44 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 46 	: b'09cb' 	 2507 	 250.7  [V] 	 [Reconnect High Voltage (RHV)]
position: 48 	: b'07a3' 	 1955 	 195.5  [V] 	 [Reconnect Low Voltage (RLV)]
position: 50 	: b'1392' 	 5010 	 50.1  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 52 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 56 	: b'07d0' 	 2000 	 20.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 58 	: b'0010' 	 16 	 0.16  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 62 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 64 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 66 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 68 	: b'0032' 	 50 	 0.5  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
Table Type:  Volt Watt (VW)
position: 72 	: b'0001' 	 1 	 1.0  [bool] 	 [VW Function Activated]
position: 74 	: b'09e2' 	 2530 	 253.0  [V] 	 [Start of Voltage Watt Droop (Vstart)]
position: 76 	: b'0a10' 	 2576 	 257.6  [V] 	 [End of Voltage Watt Droop (Vend)]
position: 78 	: b'087e' 	 2174 	 21.74  [Pn%/V] 	 [Droop Slope (Kpower_Volt)]
Table Type:  Volt Var (VV)
position: 82 	: b'0000' 	 0 	 0.0  [bool] 	 [VV Function Activated]
position: 84 	: b'0844' 	 2116 	 211.6  [V] 	 [Voltage Set Point V1]
position: 86 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q1]
position: 88 	: b'08a0' 	 2208 	 220.8  [V] 	 [Voltage Set Point V2]
position: 90 	: b'096f' 	 2415 	 241.5  [V] 	 [Voltage Set Point V3]
position: 92 	: b'09b4' 	 2484 	 248.4  [V] 	 [Voltage Set Point V4]
position: 94 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q4]
Table Type:  Specified Power Factor (SPF)
position: 98 	: b'0000' 	 0 	 0.0  [bool] 	 [SPF Function Activated]
position: 100 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 104 	: b'0000' 	 0 	 0.0  [bool] 	 [WPF Function Activated]
position: 106 	: b'01f4' 	 500 	 50.0  [%Pn] 	 [Start of Power of WPF (Pstart)]
position: 108 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor ar Rated Power (PFRP)]
Table Type:  Active Power Control (APC)
position: 112 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 114 	: b'2710' 	 10000 	 1.0  [Pn%/s] 	 [Power Ramp Rate (PRR)]
Table Type:  Reactive Power Control (RPC)
position: 118 	: b'0000' 	 0 	 0.0  [bool] 	 [RPC Function Activated]
position: 120 	: b'0000' 	 0 	 0.0  [%Sn] 	 [Reactive Power (VAR)]
CRC (?):  b'6e8b'
end
*  0d042000000c08fc07a3000f09e2001e064a00140a5500140ac8000a09e21003138812c0001413ec0014128e000514500005200000013003025809e207a3139c1356400007d0001050010001139c0190001000006000000109e20a5a021580010000085b012c08b70941099d012c006490000001005fb000000001f4005f700200012710a00200000000e57600
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'07a3' 	 1955 	 195.5  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'000f' 	 15 	 1.5  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'09e2' 	 2530 	 253.0  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'001e' 	 30 	 3.0  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'064a' 	 1610 	 161.0  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'0014' 	 20 	 0.2  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'0a55' 	 2645 	 264.5  [V] 	 [High Voltage 2 (HV2)]
position: 22 	: b'0014' 	 20 	 2.0  [s] 	 [HV2 Maximum Trip Time (MTT)]
position: 24 	: b'0ac8' 	 2760 	 276.0  [V] 	 [High Voltage 3 (HV3)]
position: 26 	: b'000a' 	 10 	 0.1  [s] 	 [HV3 Maximum Trip Time (MTT)]
position: 28 	: b'09e2' 	 2530 	 253.0  [V] 	 [10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 32 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 34 	: b'12c0' 	 4800 	 48.0  [Hz] 	 [Low Frequency 1 (LF1)]
position: 36 	: b'0014' 	 20 	 2.0  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 38 	: b'13ec' 	 5100 	 51.0  [Hz] 	 [High Frequency 1 (HF1)]
position: 40 	: b'0014' 	 20 	 2.0  [s] 	 [HF1 Maximum Trip time (MTT)]
position: 42 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF2)]
position: 44 	: b'0005' 	 5 	 0.5  [s] 	 [LF2 Maximum Trip Time (MTT)]
position: 46 	: b'1450' 	 5200 	 52.0  [Hz] 	 [High Frequency 1 (HF2)]
position: 48 	: b'0005' 	 5 	 0.5  [s] 	 [HF2 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 52 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 56 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 58 	: b'09e2' 	 2530 	 253.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 60 	: b'07a3' 	 1955 	 195.5  [V] 	 [Reconnect Low Voltage (RLV)]
position: 62 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 64 	: b'1356' 	 4950 	 49.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 68 	: b'07d0' 	 2000 	 20.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 70 	: b'0010' 	 16 	 0.16  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 74 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 76 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 78 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 80 	: b'0010' 	 16 	 0.16  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
position: 82 	: b'0000' 	 0 	 0.0  [Hz] 	 [Recovery High Frequency (RVHF)]
Table Type:  Volt Watt (VW)
position: 86 	: b'0001' 	 1 	 1.0  [bool] 	 [VW Function Activated]
position: 88 	: b'09e2' 	 2530 	 253.0  [V] 	 [Start of Voltage Watt Droop (Vstart)]
position: 90 	: b'0a5a' 	 2650 	 265.0  [V] 	 [End of Voltage Watt Droop (Vend)]
position: 92 	: b'0215' 	 533 	 5.33  [Pn%/V] 	 [Droop Slope (Kpower_Volt)]
Table Type:  Volt Var (VV)
position: 96 	: b'0000' 	 0 	 0.0  [bool] 	 [VV Function Activated]
position: 98 	: b'085b' 	 2139 	 213.9  [V] 	 [Voltage Set Point V1]
position: 100 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q1]
position: 102 	: b'08b7' 	 2231 	 223.1  [V] 	 [Voltage Set Point V2]
position: 104 	: b'0941' 	 2369 	 236.9  [V] 	 [Voltage Set Point V3]
position: 106 	: b'099d' 	 2461 	 246.1  [V] 	 [Voltage Set Point V4]
position: 108 	: b'012c' 	 300 	 30.0  [%Pn] 	 [Reactive Set Point Q4]
position: 110 	: b'0064' 	 100 	 10.0  [s] 	 [Setting Time (Tr)]
Table Type:  Specified Power Factor (SPF)
position: 114 	: b'0001' 	 1 	 1.0  [bool] 	 [SPF Function Activated]
position: 116 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 120 	: b'0000' 	 0 	 0.0  [bool] 	 [WPF Function Activated]
position: 122 	: b'01f4' 	 500 	 50.0  [%Pn] 	 [Start of Power of WPF (Pstart)]
position: 124 	: b'005f' 	 95 	 0.95  [] 	 [Power Factor ar Rated Power (PFRP)]
Table Type:  Active Power Control (APC)
position: 128 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 130 	: b'2710' 	 10000 	 1.0  [Pn%/s] 	 [Power Ramp Rate (PRR)]
Table Type:  Reactive Power Control (RPC)
position: 134 	: b'0000' 	 0 	 0.0  [bool] 	 [RPC Function Activated]
position: 136 	: b'0000' 	 0 	 0.0  [%Sn] 	 [Reactive Power (VAR)]
CRC (?):  b'e576'
end
*  12002003000008fc073000100a2800101000138812c0001013ec0010200000013003006409e2073013ec12c040000fa003e87000000106aa00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'0730' 	 1840 	 184.0  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'0010' 	 16 	 1.6  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'0a28' 	 2600 	 260.0  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'0010' 	 16 	 1.6  [s] 	 [HV1 Maximum Trip Time (MTT)]
Table Type:  Frequency (H/LFRT)
position: 18 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 20 	: b'12c0' 	 4800 	 48.0  [Hz] 	 [Low Frequency 1 (LF1)]
position: 22 	: b'0010' 	 16 	 1.6  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 24 	: b'13ec' 	 5100 	 51.0  [Hz] 	 [High Frequency 1 (HF1)]
position: 26 	: b'0010' 	 16 	 1.6  [s] 	 [HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 30 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 34 	: b'0064' 	 100 	 10.0  [s] 	 [Reconnect Time (RT)]
position: 36 	: b'09e2' 	 2530 	 253.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 38 	: b'0730' 	 1840 	 184.0  [V] 	 [Reconnect Low Voltage (RLV)]
position: 40 	: b'13ec' 	 5100 	 51.0  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 42 	: b'12c0' 	 4800 	 48.0  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 46 	: b'0fa0' 	 4000 	 40.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 48 	: b'03e8' 	 1000 	 10.0  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Active Power Control (APC)
position: 52 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
CRC (?):  b'06aa'
end
*  12002004000008fc073000100a2800101000138812c0001013ec0010200000013003006409e2073013ec12c04000138803e8700000013c1200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'0730' 	 1840 	 184.0  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'0010' 	 16 	 1.6  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'0a28' 	 2600 	 260.0  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'0010' 	 16 	 1.6  [s] 	 [HV1 Maximum Trip Time (MTT)]
Table Type:  Frequency (H/LFRT)
position: 18 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 20 	: b'12c0' 	 4800 	 48.0  [Hz] 	 [Low Frequency 1 (LF1)]
position: 22 	: b'0010' 	 16 	 1.6  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 24 	: b'13ec' 	 5100 	 51.0  [Hz] 	 [High Frequency 1 (HF1)]
position: 26 	: b'0010' 	 16 	 1.6  [s] 	 [HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 30 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 34 	: b'0064' 	 100 	 10.0  [s] 	 [Reconnect Time (RT)]
position: 36 	: b'09e2' 	 2530 	 253.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 38 	: b'0730' 	 1840 	 184.0  [V] 	 [Reconnect Low Voltage (RLV)]
position: 40 	: b'13ec' 	 5100 	 51.0  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 42 	: b'12c0' 	 4800 	 48.0  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 46 	: b'1388' 	 5000 	 50.0  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 48 	: b'03e8' 	 1000 	 10.0  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Active Power Control (APC)
position: 52 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
CRC (?):  b'3c12'
end
*  37002000000308fc0730000f09e200010410001e0ac8000510001388128e000113ec0001200000013003025809e207a81392128e40000010001050000001139c0190271090000000006470020001271001ea0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000
Table Type:  Voltage (H/LVRT)
position: 6 	: b'08fc' 	 2300 	 230.0  [V] 	 [Nominale Voltage (NV)]
position: 8 	: b'0730' 	 1840 	 184.0  [V] 	 [Low Voltage 1 (LV1)]
position: 10 	: b'000f' 	 15 	 1.5  [s] 	 [LV1 Maximum Trip Time (MTT)]
position: 12 	: b'09e2' 	 2530 	 253.0  [V] 	 [High Voltage 1 (HV1)]
position: 14 	: b'0001' 	 1 	 0.1  [s] 	 [HV1 Maximum Trip Time (MTT)]
position: 16 	: b'0410' 	 1040 	 104.0  [V] 	 [Low Voltage 2 (LV2)]
position: 18 	: b'001e' 	 30 	 0.3  [s] 	 [LV2 Maximum Trip Time (MTT)]
position: 20 	: b'0ac8' 	 2760 	 276.0  [V] 	 [High Voltage 2 (HV2)]
position: 22 	: b'0005' 	 5 	 0.5  [s] 	 [HV2 Maximum Trip Time (MTT)]
Table Type:  Frequency (H/LFRT)
position: 26 	: b'1388' 	 5000 	 50.0  [Hz] 	 [Nominal Frequency]
position: 28 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Low Frequency 1 (LF1)]
position: 30 	: b'0001' 	 1 	 0.1  [s] 	 [LF1 Maximum Trip Time (MTT)]
position: 32 	: b'13ec' 	 5100 	 51.0  [Hz] 	 [High Frequency 1 (HF1)]
position: 34 	: b'0001' 	 1 	 0.1  [s] 	 [HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 38 	: b'0001' 	 1 	 1.0  [bool] 	 [ID Function Activated]
Table Type:  Reconnection (RT)
position: 42 	: b'0258' 	 600 	 60.0  [s] 	 [Reconnect Time (RT)]
position: 44 	: b'09e2' 	 2530 	 253.0  [V] 	 [Reconnect High Voltage (RHV)]
position: 46 	: b'07a8' 	 1960 	 196.0  [V] 	 [Reconnect Low Voltage (RLV)]
position: 48 	: b'1392' 	 5010 	 50.1  [Hz] 	 [Reconnect High Frequency (RHF)]
position: 50 	: b'128e' 	 4750 	 47.5  [Hz] 	 [Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 54 	: b'0010' 	 16 	 0.16  [Rated%/s] 	 [Normal Ramp up Rate(RUR_NM)]
position: 56 	: b'0010' 	 16 	 0.16  [Rated%/s] 	 [Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 60 	: b'0001' 	 1 	 1.0  [bool] 	 [FW Function Activated]
position: 62 	: b'139c' 	 5020 	 50.2  [Hz] 	 [Start of Frequency Watt Droop (Fstart)]
position: 64 	: b'0190' 	 400 	 40.0  [Pn%/Hz] 	 [FW Droop Slope (Kpower_Freq)]
position: 66 	: b'2710' 	 10000 	 100.0  [PN%/s] 	 [Recovery Ramp Rate (RRR)]
Table Type:  Specified Power Factor (SPF)
position: 70 	: b'0000' 	 0 	 0.0  [bool] 	 [SPF Function Activated]
position: 72 	: b'0064' 	 100 	 1.0  [] 	 [Power Factor (PF)]
Table Type:  Active Power Control (APC)
position: 76 	: b'0001' 	 1 	 1.0  [bool] 	 [APC Function Activated]
position: 78 	: b'2710' 	 10000 	 1.0  [Pn%/s] 	 [Power Ramp Rate (PRR)]
CRC (?):  b'01ea'
end

@noone2k
Copy link
Author

noone2k commented Oct 24, 2023

updatet gist ( small cleanup and added grid profile names )

@noone2k
Copy link
Author

noone2k commented Oct 25, 2023

updated gist ( added crc-16/modbus check )

@noone2k
Copy link
Author

noone2k commented Oct 25, 2023

updated gist ( get rid of the binascii-lib, not needed any more )

@noone2k
Copy link
Author

noone2k commented Oct 25, 2023

example output from the "standard" profil:

python3 _hgp_qd.py 0a002001000c08fc07a3000f09e2001e064a00140a5500140ac8000a09e21003138812c0001413ec0014128e000514500005200000013003025809e207a3139c1356400007d0001050010001139c0190001000006000000109e20a5a021580010000085b012c08b70941099d012c006490000000005fb000000001f4005f700200012710a00200000000cbfe00 
Grid Profile: European - EN 50549-1:2019 
Table Type:  Voltage (H/LVRT)
position: 6 	: 08fc 	 2300 	 230.0	[V]		[Nominale Voltage (NV)]
position: 8 	: 07a3 	 1955 	 195.5	[V]		[Low Voltage 1 (LV1)]
position: 10 	: 000f 	 15 	 1.5	[s]		[LV1 Maximum Trip Time (MTT)]
position: 12 	: 09e2 	 2530 	 253.0	[V]		[High Voltage 1 (HV1)]
position: 14 	: 001e 	 30 	 3.0	[s]		[HV1 Maximum Trip Time (MTT)]
position: 16 	: 064a 	 1610 	 161.0	[V]		[Low Voltage 2 (LV2)]
position: 18 	: 0014 	 20 	 0.2	[s]		[LV2 Maximum Trip Time (MTT)]
position: 20 	: 0a55 	 2645 	 264.5	[V]		[High Voltage 2 (HV2)]
position: 22 	: 0014 	 20 	 2.0	[s]		[HV2 Maximum Trip Time (MTT)]
position: 24 	: 0ac8 	 2760 	 276.0	[V]		[High Voltage 3 (HV3)]
position: 26 	: 000a 	 10 	 0.1	[s]		[HV3 Maximum Trip Time (MTT)]
position: 28 	: 09e2 	 2530 	 253.0	[V]		[10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 32 	: 1388 	 5000 	 50.0	[Hz]		[Nominal Frequency]
position: 34 	: 12c0 	 4800 	 48.0	[Hz]		[Low Frequency 1 (LF1)]
position: 36 	: 0014 	 20 	 2.0	[s]		[LF1 Maximum Trip Time (MTT)]
position: 38 	: 13ec 	 5100 	 51.0	[Hz]		[High Frequency 1 (HF1)]
position: 40 	: 0014 	 20 	 2.0	[s]		[HF1 Maximum Trip time (MTT)]
position: 42 	: 128e 	 4750 	 47.5	[Hz]		[Low Frequency 1 (LF2)]
position: 44 	: 0005 	 5 	 0.5	[s]		[LF2 Maximum Trip Time (MTT)]
position: 46 	: 1450 	 5200 	 52.0	[Hz]		[High Frequency 1 (HF2)]
position: 48 	: 0005 	 5 	 0.5	[s]		[HF2 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 52 	: 0001 	 1 	 1.0	[bool]		[ID Function Activated]
Table Type:  Reconnection (RT)
position: 56 	: 0258 	 600 	 60.0	[s]		[Reconnect Time (RT)]
position: 58 	: 09e2 	 2530 	 253.0	[V]		[Reconnect High Voltage (RHV)]
position: 60 	: 07a3 	 1955 	 195.5	[V]		[Reconnect Low Voltage (RLV)]
position: 62 	: 139c 	 5020 	 50.2	[Hz]		[Reconnect High Frequency (RHF)]
position: 64 	: 1356 	 4950 	 49.5	[Hz]		[Reconnect Low Frequency (RLF)]
Table Type:  Ramp Rates (RR)
position: 68 	: 07d0 	 2000 	 20.0	[Rated%/s]		[Normal Ramp up Rate(RUR_NM)]
position: 70 	: 0010 	 16 	 0.16	[Rated%/s]		[Soft Start Ramp up Rate (RUR_SS)]
Table Type:  Frequency Watt (FW)
position: 74 	: 0001 	 1 	 1.0	[bool]		[FW Function Activated]
position: 76 	: 139c 	 5020 	 50.2	[Hz]		[Start of Frequency Watt Droop (Fstart)]
position: 78 	: 0190 	 400 	 40.0	[Pn%/Hz]		[FW Droop Slope (Kpower_Freq)]
position: 80 	: 0010 	 16 	 0.16	[PN%/s]		[Recovery Ramp Rate (RRR)]
position: 82 	: 0000 	 0 	 0.0	[Hz]		[Recovery High Frequency (RVHF)]
Table Type:  Volt Watt (VW)
position: 86 	: 0001 	 1 	 1.0	[bool]		[VW Function Activated]
position: 88 	: 09e2 	 2530 	 253.0	[V]		[Start of Voltage Watt Droop (Vstart)]
position: 90 	: 0a5a 	 2650 	 265.0	[V]		[End of Voltage Watt Droop (Vend)]
position: 92 	: 0215 	 533 	 5.33	[Pn%/V]		[Droop Slope (Kpower_Volt)]
Table Type:  Volt Var (VV)
position: 96 	: 0000 	 0 	 0.0	[bool]		[VV Function Activated]
position: 98 	: 085b 	 2139 	 213.9	[V]		[Voltage Set Point V1]
position: 100 	: 012c 	 300 	 30.0	[%Pn]		[Reactive Set Point Q1]
position: 102 	: 08b7 	 2231 	 223.1	[V]		[Voltage Set Point V2]
position: 104 	: 0941 	 2369 	 236.9	[V]		[Voltage Set Point V3]
position: 106 	: 099d 	 2461 	 246.1	[V]		[Voltage Set Point V4]
position: 108 	: 012c 	 300 	 30.0	[%Pn]		[Reactive Set Point Q4]
position: 110 	: 0064 	 100 	 10.0	[s]		[Setting Time (Tr)]
Table Type:  Specified Power Factor (SPF)
position: 114 	: 0000 	 0 	 0.0	[bool]		[SPF Function Activated]
position: 116 	: 005f 	 95 	 0.95	[]		[Power Factor (PF)]
Table Type:  Watt Power Factor (WPF)
position: 120 	: 0000 	 0 	 0.0	[bool]		[WPF Function Activated]
position: 122 	: 01f4 	 500 	 50.0	[%Pn]		[Start of Power of WPF (Pstart)]
position: 124 	: 005f 	 95 	 0.95	[]		[Power Factor ar Rated Power (PFRP)]
Table Type:  Active Power Control (APC)
position: 128 	: 0001 	 1 	 1.0	[bool]		[APC Function Activated]
position: 130 	: 2710 	 10000 	 1.0	[Pn%/s]		[Power Ramp Rate (PRR)]
Table Type:  Reactive Power Control (RPC)
position: 134 	: 0000 	 0 	 0.0	[bool]		[RPC Function Activated]
position: 136 	: 0000 	 0 	 0.0	[%Sn]		[Reactive Power (VAR)]
CRC (ok):  cbfe
end

@noone2k
Copy link
Author

noone2k commented Oct 29, 2023

updated gist ( further cleanup )
for now the "final" version: every bit squeezed out and most output of them are reasonable
can still have errors in the dizs and dividers ... feel free to report errors/remarks

@stefan123t
Copy link

stefan123t commented Nov 22, 2023

@noone2k thanks for the parser. It works with the GridProfile which I got from @lumapu here lumapu/ahoy#365 (comment), which also is the exact sample given in the comment of your initial _hgp_qd.py script.

# param 1: grid profile
# f.ex. python3 _hgp_qd.py 0a002001000c08fc07a3000f09e2001e064a00140a5500140ac8000a09e21003138812c0001413ec0014128e000514500005200000013003025809e207a3139c1356400007d0001050010001139c0190001000006000000109e20a5a021580010000085b012c08b70941099d012c006490000000005fb000000001f4005f700200012710a00200000000cbfe00

But it did fail for the second sample I got from Flole's mock S-Miles Cloud DTU, which I have decoded manually in the spread sheet also attached to the above comment: DE_VDE4105_2018_v2.0.0_20230924.xlsx. In fact the byte order has to be reversed in order for it to be detected correctly by your code.

$ python3 _hgp_qd.py 03002000000a08fc0730001e0b3b0001040b001e09e210001388128e0001141e000120000001300302580ac807a31392128e400007d003e850080001139c0190001001f6137470020001271080000000085b012c08b70941099d012c90000000ffa1b000000001f4005fa00200000000
Grid Profile: Germany - DE_VDE4105_2018 
Version: 2.0.0
Table Type:  Voltage (H/LVRT)

@stefan123t
Copy link

Please double check the ranges given in the Hoymiles S-Cloud Grid Profile Editor and/or the values I have calculated in the above Spread sheet for the following values, which I have also marked red in the spread sheet for obviously exceeding the prescribed ranges of the Grid Profile:

position: 42 	: 0ac8 	 2760 	 276.0	[V]		[Reconnect High Voltage (RHV)] -> according to DE_VDE4105_2018 I would assume a maximum of 253,0 V though this could be a later version 2.0.0 ?
...
position: 66 	: 01f6 	 502 	 5.02	[Hz]		[Recovery High Frequency (RVHF)] -> this should be 50,2 Hz
...
position: 74 	: 2710 	 10000 	 1.0	[Pn%/s]		[Power Ramp Rate (PRR)] -> should be between 0.33 .. 100.00 Pn%/s, hence this reads as 100,00 Pn%/s
...
position: 96 	: ffa1 	 65441 	 654.41	[]		[Power Factor (PF)] -> this should be between 0.9 and 1.0, dunno how this translates somehow

same for the original sample from lumapu and your elaborate parser sample:

AT_TOR_Erzeuger_default <- I compared lists & values to the ranges of this Grid Profile, though you managed to find several more in European - EN 50549-1:2019
...
position: 18 	: 0014 	 20 	 0.2	[s]		[LV2 Maximum Trip Time (MTT)] -> I would assume 2.0s
...
position: 26 	: 000a 	 10 	 0.1	[s]		[HV3 Maximum Trip Time (MTT)] -> I would assume 1.0s
...
position: 42 	: 128e 	 4750 	 47.5	[Hz]		[Low Frequency 1 (LF2)] -> typo: Low Frequency **2** (LF2)
...
position: 46 	: 1450 	 5200 	 52.0	[Hz]		[High Frequency 1 (HF2)] -> typo: High Frequency **2** (HF2)
...
position: 92 	: 0215 	 533 	 5.33	[Pn%/V]		[Droop Slope (Kpower_Volt)] -> I would assume 53.3 Pn%/V
...
position: 130 	: 2710 	 10000 	 1.0	[Pn%/s]		[Power Ramp Rate (PRR)] -> I would assume 100.00 Pn%/s

@stefan123t
Copy link

@noone2k
Copy link
Author

noone2k commented Nov 22, 2023

thx ... i will have a look ...

note ... the 2nd example have to be byte swapped...and there is a byte missing ( leading 00 )
//edit, the swapping you already mentioned ...

python3 _hgp_test.py 000300200a00fc0830071e003b0b01000b041e00e209001088138e1201001e1401000020010003305802c80aa30792138e120040d007e803085001009c1390011000f6017413027001001027008000005b082c01b70841099d092c0100900000a1ff00b00000f4015f0002a00000000000000000000000
->>>: 03002000000a08fc0730001e0b3b0001040b001e09e210001388128e0001141e000120000001300302580ac807a31392128e400007d003e850080001139c0190001001f6137470020001271080000000085b012c08b70941099d012c90000000ffa1b000000001f4005fa00200000000000000000000
Grid Profile: Germany - DE_VDE4105_2018 
Version: 2.0.0
Table Type:  Voltage (H/LVRT)
position: 6 	: 08fc 	 2300 	 230.0	[V]		[Nominale Voltage (NV)]
position: 8 	: 0730 	 1840 	 184.0	[V]		[Low Voltage 1 (LV1)]
position: 10 	: 001e 	 30 	 3.0	[s]		[LV1 Maximum Trip Time (MTT)]
position: 12 	: 0b3b 	 2875 	 287.5	[V]		[High Voltage 1 (HV1)]
position: 14 	: 0001 	 1 	 0.1	[s]		[HV1 Maximum Trip Time (MTT)]
position: 16 	: 040b 	 1035 	 103.5	[V]		[Low Voltage 2 (LV2)]
position: 18 	: 001e 	 30 	 3.0	[s]		[LV2 Maximum Trip Time (MTT)]
position: 20 	: 09e2 	 2530 	 253.0	[V]		[10mins Average High Voltage (AHV)]
Table Type:  Frequency (H/LFRT)
position: 24 	: 1388 	 5000 	 50.0	[Hz]		[Nominal Frequency]
position: 26 	: 128e 	 4750 	 47.5	[Hz]		[Low Frequency 1 (LF1)]
position: 28 	: 0001 	 1 	 0.1	[s]		[LF1 Maximum Trip Time (MTT)]
position: 30 	: 141e 	 5150 	 51.5	[Hz]		[High Frequency 1 (HF1)]
position: 32 	: 0001 	 1 	 0.1	[s]		[HF1 Maximum Trip time (MTT)]
Table Type:  Island Detection (ID)
position: 36 	: 0001 	 1 	 1.0	[bool]		[ID Function Activated]
Table Type:  Reconnection (RT) 
.....

@stefan123t
Copy link

stefan123t commented Nov 23, 2023

@noone2k yes your parser is almost feature complete as far as I know. Thanks a lot for the effort!
Only some minor typo's are left and a couple of divisor glitches, where I do not agree with the output yet.

BTW: Do you think it would be feasible to add another digit to some of the values in order to reflect the precision used in the actual grid profile?

position: 24 	: 1388 	 5000 	 50.0	[Hz]		[Nominal Frequency] -> actually 50.00 Hz
position: 26 	: 128e 	 4750 	 47.5	[Hz]		[Low Frequency 1 (LF1)] -> actually 47.50 Hz

In the Hoymiles UI they refer to the values using line / ID numbers, whereas you refer to the starting position in the byte stream.
I guess we should also add line numbers for convenience, maybe you can refer to the spreadsheet for two examples.

Also note that I have mentioned the value ranges in the spreadsheet which were given on the S-Miles Cloud entry form for the Grid Profiles.
I only had screenshots to work with, so I do not know if you can really modify the values within those ranges, but the UI suggests it.

You may also want to double check our wiki on the Grid Profile known to me here: https://github.com/lumapu/ahoy/wiki/Protocol#wie-wird-das-down_pro-0x0e--down_dat-0x0a-verwendet

It contains the following Grid Profiles:
File Name: AT_TOR_Erzeuger_default
File Name: DE_VDE4105_2011
File Name: DE_VDE4105_2018
File Name: AT-OVE-E-8001
File Name: Germany_VDE4105
File Name: LN_50Hz

//edit: yes the byte swapping is necessary, depending on whether you trace the Grid Profile via NRF24L01+ / CMT2300A communication on the air or whether it is captured using the "newer" DTU-BI (built-in) or S-Miles Cloud API protocol used between e.g. the DTU W-Lite / DTU Pro and the S-Miles Cloud. They do reverse the byte-order somewhere in the Network ProtoBuf library included in DTU Pro Source Code, IMHO.

Maybe another addition would be to try it in given byte order and if CRC does not match try to reverse byte order ?

@noone2k
Copy link
Author

noone2k commented Nov 23, 2023

allright, had a quick look ( left out the typos, will be updated with the next gist )

position: 18 	: 0014 	 20 	 0.2	[s]		[LV2 Maximum Trip Time (MTT)] -> I would assume 2.0s
position: 26 	: 000a 	 10 	 0.1	[s]		[HV3 Maximum Trip Time (MTT)] -> I would assume 1.0s

is actually right ... the higher the drift, the faster the device shuts down.

position: 92 : 0215 533 5.33 [Pn%/V] [Droop Slope (Kpower_Volt)] -> I would assume 53.3 Pn%/V
looks right to me, according the pdfs postet at the wiki, also the previous trip time matches

position: 130 : 2710 10000 1.0 [Pn%/s] [Power Ramp Rate (PRR)] -> I would assume 100.00 Pn%/s
you're right ... updated already in my local copy

position: 42 : 0ac8 2760 276.0 [V] [Reconnect High Voltage (RHV)]
your thoughts are right. changed during different versions

position: 66 : 01f6 502 5.02 [Hz] [Recovery High Frequency (RVHF)]
you're right. BUT: i've another example where it decodes to 50.2.
here i assume that the profile is (maybe) wrongly generated by hoymiles.
if not, this would be the only freq-divider where the divider differs from ALL others.

position: 96 : ffa1 65441 654.41 [] [Power Factor (PF)]
also decodes right on most examples. could be a placeholder, as the SPF module is disabled anyway.

hopefully missed no remark.

@stefan123t
Copy link

stefan123t commented Nov 23, 2023

@noone2k I flipped through the PDFs on the Wiki but could not find the 5.33 Pn%/V Droop Slope, which one did you see this ?

For the Power Factor I have seen one Power Factor 0.95 with Leading (/Lagging) being selected prior to it in the AT TOR-A Grid Profile PDF.

position: 96 	: 005f 	 95 	 0.95	[]		[Power Factor (PF)] -> in CRC 6c58
vs.
position: 96 	: ffa1 	 65441 	 654.41	[]		[Power Factor (PF)] -> in CRC 9c27

Maybe the ff is signalling this negative - Lagging / positive + Leading select box value.
But what would be the remainder a1 or 161 ?
A Power Factor of 1.61 does sound pretty odd to me.

For the 5.02 RVHF this is certainly verbatim in the Grid Profiles we analysed, actually both in v2.0.0 and v2.0.1 of most of the same 0300 Grid Profile "Templates".
Though there is also one 0300 template with CRC e86e which has it IMHO right:

position: 66 	: 139c 	 5020 	 50.2	[Hz]		[Recovery High Frequency (RVHF)] -> in CRC e86e
vs.
position: 66 	: 01f6 	 502 	 5.02	[Hz]		[Recovery High Frequency (RVHF)] -> e.g. in CRC ce67

I would reason the RVHF Recovery High Frequency cannot (ever) be below the RVLF (Recovery Low Frequency), for any practical purpose.

Also note there is another typo with PN instead of Pn

position: 80 	: 0010 	 16 	 0.16	[PN%/s]		[Recovery Ramp Rate (RRR)] -> this should be Pn%/s

@noone2k
Copy link
Author

noone2k commented Nov 23, 2023

thx again ...
typos locally corrected.

flipped through the PDFs on the Wiki but could not find the 5.33 Pn%/V Droop Slope, which one did you see this ?

yep, it is missing on the wiki
search for "Technical-Note-How-to-set-Hoymiles-3Gen-Grid-Profile", that is the base i'm worked from.

position: 96 : ffa1 65441 654.41 [] [Power Factor (PF)] -> in CRC 9c27
you've a point ... didnt recognize the leading selection. must be analyzed further.

for RHVF:
all frequency values have a divider of 100, except this one. makes no sense to me.
my thoughts:
firmware-bug - this "wrong" value can be fixed in two ways: firmware or grid profile.
since previously it was 5020 and afterwards 502, it looks like it was fixed with a "wrong" profile by hoymiles,
instead the firmware ( since profiles are easier to update )
or my first thought: profile wrong generated by hoymiles.
but: this is all guessing.
if the firmware divides this frequency value "accidentally" by 10, then the 502 is right,
otherwise the profile is wrong generated.

@noone2k
Copy link
Author

noone2k commented Nov 23, 2023

updated gist with the corrections
btw. somehow i mixes something up with my local edits ... hopefully, its still ok although
i finished this "walkthrough" already some time ago and my head is already on the next adventure :-)

@stefan123t
Copy link

stefan123t commented Nov 26, 2023

Thanks I transferred your code into the PR tbnobody/OpenDTU#1527

Please take a look at my guess work in tbnobody/OpenDTU#987 (comment) regarding the Leading flag.
I still have a 0.01 (one-off) in my calculation.

Regarding the fix for RVHF I do agree, it looks like they added some special versions of the Hoymiles Firmware.
Also see tbnobody/OpenDTU#987 for some reports about upgrades to the Firmware due to Grid Profile oddities.

@noone2k
Copy link
Author

noone2k commented Dec 6, 2023

updates gist ( 2 profiles added / incomplete )
need more informations from ( printout from s-miles cloud )

@stefan123t
Copy link

stefan123t commented Dec 7, 2023

search for "Technical-Note-How-to-set-Hoymiles-3Gen-Grid-Profile", that is the base i'm worked from.

position: 96 : ffa1 65441 654.41 [] [Power Factor (PF)] -> in CRC 9c27 you've a point ... didnt recognize the leading selection. must be analyzed further.

The document you rightfully referred to here https://www.hoymiles.com/wp-content/uploads/2022/11/Technical-Note-How-to-set-Hoymiles-3Gen-Grid-Profile-V1.1.pdf has it in the fine print:

3.9 Specified Power Factor (SPF)
The specified power factor mode is required in some situations by the electric utility to
meet the local requirements. The minimum range of the setting of the fixed power factor is
0.8 leading to 0.8 lagging.
Note1: Power factor is ratio of the absolute value of the active power P to the apparent power S under
periodic conditions.
Note2: Lagging power factor is defined to be when the inverter acts as an inductive load from the
perspective of the grid. Leading power factor is defined to be when the inverter acts as a capacitive load
from the perspective of the grid.
Note3: As shown in the table below, if the input value of power factor is positive, the leading power factor
will be set while if the input value of power factor is negative, the lagging power factor will be set.

Table 9 Specified Power Factor Module

Specified Power Factor (SPF) - - -
Parameter Value Unit Range(min-max)
Function Activated 0 / 0: Disable
1: Enable
Power Factor (PF) 0.95 / -0.9~0.9

So Leading is positive and Lagging is negative, hence -0 = 65536 -> 65536 - 95 = 65441 = 0xffa1 as expected.

The same is stated for Power Factor at Rated Power (PFRP) under 3.10 Watt Power Factor (WPF)

@stefan123t
Copy link

Oh by the way, would you consider it worthwhile to sort the tables_struct by the table_nr and table_ver ?

I did clean up the code in my fork of the gist you opened and I find it quite telling that "Poland - EU_EN54038" has table_ver 0x00, whereas Germany has 0x0a and AT_TOR 0x0b respectively. They are likely based on later changes within local law / regulations based on the original EU_EN54038 norm.

@stefan123t
Copy link

@noone2k tbnobody already implemented your parser in the latest OpenDTU release in commits tbnobody/OpenDTU@06651f3 and tbnobody/OpenDTU@00bc631

@Fribur
Copy link

Fribur commented Dec 25, 2023

@stefan123t , @noone2k : I made some changes to parse IEEE 1547 240V correctly in this fork. How to interpret tables / sub-tables and divider taken from here. In case there is some doubt about the divider (e.g. 1.6s or 0.16s), here some nice tabular overviews of the permitted parameter. BTW I am not sure what exactly the difference between IEEE 1547 240V and California Rule21 240V is (If there is any...maybe rule 21 is just interpreting IEEE1547...or rule 21 is making it mandatory to use the IEEE 1547 240V grid profile).

@noone2k
Copy link
Author

noone2k commented Dec 25, 2023

thx ... i'll try to put everything together , once i find some time

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment