001c14-L1>power up
001c14 ATTN: Cooling system stabilized
returning to console mode 001c14 CPU0, <CTRL_T> to escape to L1
Starting PROM Boot process
IP35 PROM SGI Version 6.201 built 08:59:10 AM Jun 2, 2004
Testing/Initializing memory ............... DONE
Copying PROM code to memory ............... DONE
Discovering local IO ...................... DONE
Discovering NUMAlink connectivity ......... DONE
Found 2 objects (2 hubs, 0 routers) in 7128 usec
Waiting for peers to complete discovery.... DONE
Global master is /hw/rack/001/bay/14
DONE
Global master is /hw/rack/001/bay/14
Intializing any CPUless nodes.............. DONE
Checking partitioning information ......... DONE
Checking partitioning information ......... DONE
INFO: console subchannel changed: 001c16 CPU2
Local slave entering slave loop
INFO: console subchannel changed: 001c16 CPU0
Local master entering slave loop
Local slave entering slave loop
Local slave entering slave loop
Local slave entering slave loop
Loading BASEIO prom ....................... DONE
BASEIO PROM Monitor SGI Version 6.201 built 08:56:46 AM Jun 2, 2004 (BE64)
6 CPUs on 2 nodes found.
Automatic update of PROM environment disabled
Graphics diagnostics
Odyssey board #0 found on nasid 0
Running Odyssey xtalk sanity diag...
Board version 1 - Buzz revision 3B
On board sdram size: 128 Mb
Cas latency: CAS 3
4 banks by sdram module
Running Odyssey Buzz registers diag...
Device passed diagnostics
Odyssey board #1 found on nasid 1
Running Odyssey xtalk sanity diag...
Board version 1 - Buzz revision 3B
On board sdram size: 128 Mb
Cas latency: CAS 3
4 banks by sdram module
Running Odyssey Buzz registers diag...
Device passed diagnostics
***WARNING: Master I-brick was /hw/module/001c01/iobrick but is now /hw/module/001c14/iobrick
Check for LINK errors or setenv ConsolePath to new value.
Installing PROM Device drivers ............
On-board (IO9) tigon3 1000BaseT interface
Base I/O Ethernet set to /dev/ethernet/tg0
Installing Graphics Console...
graphics install: searching for pipe 0
Probing IOC4 ATA adapter 2
IOC4 RevId = 79
Detected Vendor id/Product MATSHITA DVD-ROM SR-8177
Walking SCSI Adapter 0, (pci id 3)
1+ Device Vendor Product: SGI ST373307LC
2+ Device Vendor Product: SGI ST373307LC
3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- = 2 device(s)
Walking SCSI Adapter 1, (pci id 3)
1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- = 0 device(s)
Initializing PROM Device drivers ..........
Initializing Base I/O Ethernet Interface...Failed. MII Status Register = 0x7949
Done.
---------------Interface Configuration Summary----------------
ASIC|Revision|MAC Address : 5701|B5|08:00:69:13:fb:9a
Link Negotiation|Advertisement : On|<H10 F10 H100 F100 F1000>
Link|Speed|Duplex|Rx/Tx FlowCtrl: Down|10|Half|Off/Off
--------------------------------------------------------------
DONE
Cannot connect to keyboard -- check the cable.
Cannot open /dev/input/ioc4pckm0 for input
Cannot connect to keyboard -- check the cable.
Cannot open /dev/input/ioc4pckm0 for input
Checking hardware inventory ............... DONE
**** System Configuration and Diagnostics Summary ****
CONFIG:
No. of NODEs enabled = 2
No. of NODEs disabled = 0
No. of CPUs enabled = 6
No. of CPUs disabled = 0
Mem enabled = 12288 MB
Mem disabled = 0 MB
No. of RTRs enabled = 0
No. of RTRs disabled = 0
DIAG RESULTS:
ALL DIAGS PASSED.
**** End System Configuration and Diagnostics Summary ****
System Maintenance Menu
1) Start System
2) Install System Software
3) Run Diagnostics
4) Recover System
5) Enter Command Monitor
Option?
>> hinv
System SGI-IP35
6 700 MHz IP35 Processors
Main memory size: 12288 Mbytes
Graphics Controller
PCI IOC4: in slot 1, (adapter 0)
Graphics Controller
USB (OHCI interface)
USB (OHCI interface)
PCI Gigabit Ethernet (tigon3) Controller 1
Integral SCSI controller 2: Version IOC4 ATA
CDROM: unit 0 on SCSI Controller 2, (cdrom(2,0,7))
Integral SCSI controller 0: Version Qlogic 12160
Disk drive: unit 1 on SCSI Controller 0, (dksc(0,1,0))
Disk drive: unit 2 on SCSI Controller 0, (dksc(0,2,0))
Integral SCSI controller 1: Version Qlogic 12160
>> hinv -v
IP35 Node Board, Module 001c14
ASIC BEDROCK Rev 2, 200 MHz, (nasid 0)
Processor A: 700 MHz R16000 Rev 2.1
Secondary Cache 4MB 350MHz Tap 0xc , (cpu 0)
R16010FPC Rev 2.1
Processor B: 700 MHz R16000 Rev 2.1
Secondary Cache 4MB 350MHz Tap 0xc , (cpu 1)
R16010FPC Rev 2.1
Processor C: 700 MHz R16000 Rev 2.1
Secondary Cache 4MB 350MHz Tap 0xc , (cpu 2)
R16010FPC Rev 2.1
Processor D: 700 MHz R16000 Rev 2.1
Secondary Cache 4MB 350MHz Tap 0xc , (cpu 3)
R16010FPC Rev 2.1
Memory on board, 8192 MBytes (Standard)
Bank 0, 1024 MBytes (Premium) <-- (Software Bank 0)
Bank 1, 1024 MBytes (Premium)
Bank 2, 1024 MBytes (Premium)
Bank 3, 1024 MBytes (Premium)
Bank 4, 1024 MBytes (Premium)
Bank 5, 1024 MBytes (Premium)
Bank 6, 1024 MBytes (Premium)
Bank 7, 1024 MBytes (Premium)
IP35 Node Board, Module 001c16
ASIC BEDROCK Rev 2, 200 MHz, (nasid 1)
Processor A: 700 MHz R16000 Rev 2.1
Secondary Cache 4MB 350MHz Tap 0xc , (cpu 4)
R16010FPC Rev 2.1
Processor C: 700 MHz R16000 Rev 2.1
Secondary Cache 4MB 350MHz Tap 0xc , (cpu 5)
R16010FPC Rev 2.1
Memory on board, 4096 MBytes (Standard)
Bank 0, 1024 MBytes (Premium) <-- (Software Bank 0)
Bank 1, 1024 MBytes (Premium)
Bank 2, 1024 MBytes (Premium)
Bank 3, 1024 MBytes (Premium)
IXBRICK Bridge, Module 001c14
ASIC BRIDGE Rev 3, (widget 15)
adapter IOC4 Rev 4f
(pci id 1)
adapter IOC4-ATA Rev 4f
(pci id 1)
peripheral CDROM, BUS 0, ID 0, MATSHITA DVD-ROM SR-8177
adapter PCI (SCSI interface) Rev 6
(pci id 3)
peripheral DISK, BUS 0, ID 1, SGI ST373307LC
peripheral DISK, BUS 0, ID 2, SGI ST373307LC
adapter GigE Rev 15
(pci id 4)
IXBRICK Bridge, Module 001c14
ASIC BRIDGE Rev 3, (widget 15)
adapter ID (Vendor 14e4 Device 1648 class 2 subclass 2)
(pci id 1 function 0)
adapter ID (Vendor 14e4 Device 1648 class 2 subclass 2)
(pci id 1 function 1)
adapter ID (Vendor 14e4 Device 1648 class 2 subclass 2)
(pci id 2 function 0)
adapter ID (Vendor 14e4 Device 1648 class 2 subclass 2)
(pci id 2 function 1)
IXBRICK Bridge, Module 001c16
ASIC BRIDGE Rev 3, (widget 15)
adapter ID (Vendor 1077 Device 2312 class c subclass c)
(pci id 1 function 0)
adapter ID (Vendor 1077 Device 2312 class c subclass c)
(pci id 1 function 1)
IXBRICK Bridge, Module 001c16
ASIC BRIDGE Rev 3, (widget 15)
adapter USB (OHCI interface)
(pci id 2 function 0)
adapter USB (OHCI interface)
(pci id 2 function 1)
ASIC XBOW Rev 3, on CBrick, Module 001c14
ASIC XBOW Rev 3, on CBrick, Module 001c16
ODYSSEY Graphics Board, Module 001c14
ODYSSEY Graphics Board, Module 001c16
>> hinv -mvvv
location: /hw/rack/001/bay/14
Part:030-1868-001;Name:IP53_4CPU;Serial:NGA704;Revision:-C;Group:ff;Capability:ffffffff;Variety:ff;Laser:0000000054860df4;
location: /hw/rack/001/bay/14
Part:030-1909-007;Name:ODY128B1_2;Serial:NCN884;Revision:-C;Group:ff;Capability:ffffffff;Variety:ff;Laser:000000005428d164;
location: /hw/rack/001/bay/14
Part:030-1809-005;Name:2U_INT_53;Serial:NGL825;Revision:-A;Group:ff;Capability:ffffffff;Variety:ff;Laser:00000000548de80d;
location: /hw/rack/001/bay/14
Part:030-1809-005;Name:2U_INT_53;Serial:NGL825;Revision:-A;Group:ff;Capability:ffffffff;Variety:ff;Laser:00000000548de80d;
location: /hw/rack/001/bay/16
Part:030-1869-001;Name:IP53_2CPU;Serial:NGB292;Revision:-D;Group:ff;Capability:ffffffff;Variety:ff;Laser:000000005486ac26;
location: /hw/rack/001/bay/16
Part:030-1909-007;Name:ODY128B1_2;Serial:MZD394;Revision:-C;Group:ff;Capability:ffffffff;Variety:ff;Laser:0000000052d46cb8;
location: /hw/rack/001/bay/16
Part:030-1809-004;Name:2U_INT_53;Serial:NGH593;Revision:-A;Group:ff;Capability:ffffffff;Variety:ff;Laser:00000000548b00d7;
location: /hw/rack/001/bay/16
Part:030-1809-004;Name:2U_INT_53;Serial:NGH593;Revision:-A;Group:ff;Capability:ffffffff;Variety:ff;Laser:00000000548b00d7;