smartctl
[root@hv ~]# for d in sda sdb sdc sde; do echo "Smartctl for /dev/$d"; echo; smartctl -a /dev/$d; echo; done
Smartctl for /dev/sda
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.9.14-200.fc25.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 5400.6
Device Model: ST9500325AS
Serial Number: S2W51N2D
LU WWN Device Id: 5 000c50 04621c08f
Firmware Version: 0003SDM1
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Apr 4 09:32:41 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 140) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x103b) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 119 099 006 Pre-fail Always - 205081872
3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1903
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 1
7 Seek_Error_Rate 0x000f 081 060 030 Pre-fail Always - 120023605
9 Power_On_Hours 0x0032 080 080 000 Old_age Always - 18079
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 099 099 020 Old_age Always - 1919
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 069 000 Old_age Always - 2495414076952
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 058 047 045 Old_age Always - 42 (Min/Max 40/43)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 921
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 0
193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 471791
194 Temperature_Celsius 0x0022 042 053 000 Old_age Always - 42 (0 7 0 0 0)
195 Hardware_ECC_Recovered 0x001a 052 048 000 Old_age Always - 205081872
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 191 000 Old_age Always - 488439
254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 5708 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Smartctl for /dev/sdb
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.9.14-200.fc25.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 5400.6
Device Model: ST9500325AS
Serial Number: 6VEM6FJ6
LU WWN Device Id: 5 000c50 032c20ce1
Firmware Version: 0003SDM1
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Apr 4 09:32:41 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 140) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x103b) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 118 083 006 Pre-fail Always - 173961409
3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 096 096 020 Old_age Always - 4607
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 3
7 Seek_Error_Rate 0x000f 083 060 030 Pre-fail Always - 232905160
9 Power_On_Hours 0x0032 085 085 000 Old_age Always - 13216
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 096 096 020 Old_age Always - 4623
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 743
188 Command_Timeout 0x0032 100 098 000 Old_age Always - 21475164180
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 058 047 045 Old_age Always - 42 (Min/Max 40/43)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 338
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 68
193 Load_Cycle_Count 0x0032 082 082 000 Old_age Always - 37512
194 Temperature_Celsius 0x0022 042 053 000 Old_age Always - 42 (0 14 0 0 0)
195 Hardware_ECC_Recovered 0x001a 052 039 000 Old_age Always - 173961409
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 1136 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1136 occurred at disk power-on lifetime: 4108 hours (171 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 47 18 ce 0b Error: UNC at LBA = 0x0bce1847 = 198056007
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 40 2a 32 0b 40 00 00:57:10.254 READ FPDMA QUEUED
61 00 08 a8 e6 62 40 00 00:57:10.253 WRITE FPDMA QUEUED
61 00 08 90 2a 37 40 00 00:57:10.253 WRITE FPDMA QUEUED
61 00 08 a0 e1 62 40 00 00:57:10.252 WRITE FPDMA QUEUED
61 00 08 18 2a 37 40 00 00:57:10.251 WRITE FPDMA QUEUED
Error 1135 occurred at disk power-on lifetime: 4108 hours (171 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 47 18 ce 0b Error: WP at LBA = 0x0bce1847 = 198056007
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
61 00 08 48 cc 60 40 00 00:57:07.622 WRITE FPDMA QUEUED
61 00 08 30 ef 5f 40 00 00:57:07.621 WRITE FPDMA QUEUED
61 00 08 90 40 60 40 00 00:57:07.618 WRITE FPDMA QUEUED
61 00 08 20 ef 5f 40 00 00:57:07.617 WRITE FPDMA QUEUED
61 00 08 18 3c 60 40 00 00:57:07.617 WRITE FPDMA QUEUED
Error 1134 occurred at disk power-on lifetime: 4108 hours (171 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 47 18 ce 0b Error: WP at LBA = 0x0bce1847 = 198056007
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
61 00 08 00 ef 5b 40 00 00:57:04.911 WRITE FPDMA QUEUED
60 00 20 20 5f 65 40 00 00:57:04.908 READ FPDMA QUEUED
61 00 08 48 53 65 40 00 00:57:04.907 WRITE FPDMA QUEUED
61 00 08 78 c4 64 40 00 00:57:04.906 WRITE FPDMA QUEUED
60 00 38 f8 79 8e 4b 00 00:57:04.906 READ FPDMA QUEUED
Error 1133 occurred at disk power-on lifetime: 4108 hours (171 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 47 18 ce 0b Error: UNC at LBA = 0x0bce1847 = 198056007
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 80 78 79 8e 4b 00 00:57:02.145 READ FPDMA QUEUED
60 00 20 30 18 ce 4b 00 00:57:02.141 READ FPDMA QUEUED
60 00 08 88 91 8b 4b 00 00:57:02.139 READ FPDMA QUEUED
60 00 20 40 ae fb 48 00 00:57:02.127 READ FPDMA QUEUED
61 00 08 88 ac 6f 46 00 00:57:02.126 WRITE FPDMA QUEUED
Error 1132 occurred at disk power-on lifetime: 4108 hours (171 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 47 18 ce 0b Error: UNC at LBA = 0x0bce1847 = 198056007
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 08 e0 b4 60 40 00 00:56:59.437 READ FPDMA QUEUED
61 00 08 c0 53 01 40 00 00:56:59.431 WRITE FPDMA QUEUED
60 00 40 10 18 ce 4b 00 00:56:59.427 READ FPDMA QUEUED
60 00 80 c0 42 13 46 00 00:56:59.427 READ FPDMA QUEUED
60 00 40 48 d2 2f 45 00 00:56:59.426 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Smartctl for /dev/sdc
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.9.14-200.fc25.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: KINGSTON SV300S37A120G
Serial Number: 50026B775B093A31
LU WWN Device Id: 5 0026b7 75b093a31
Firmware Version: 605ABBF2
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Apr 4 09:32:42 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0025) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0032 120 120 050 Old_age Always - 0/0
5 Retired_Block_Count 0x0033 100 100 003 Pre-fail Always - 0
9 Power_On_Hours_and_Msec 0x0032 093 093 000 Old_age Always - 6150h+31m+13.660s
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 32
171 Program_Fail_Count 0x000a 100 100 000 Old_age Always - 0
172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0
174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline - 20
177 Wear_Range_Delta 0x0000 000 000 000 Old_age Offline - 0
181 Program_Fail_Count 0x000a 100 100 000 Old_age Always - 0
182 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0
187 Reported_Uncorrect 0x0012 100 100 000 Old_age Always - 0
189 Airflow_Temperature_Cel 0x0000 039 046 000 Old_age Offline - 39 (Min/Max 23/46)
194 Temperature_Celsius 0x0022 039 046 000 Old_age Always - 39 (Min/Max 23/46)
195 ECC_Uncorr_Error_Count 0x001c 120 120 000 Old_age Offline - 0/0
196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0
201 Unc_Soft_Read_Err_Rate 0x001c 120 120 000 Old_age Offline - 0/0
204 Soft_ECC_Correct_Rate 0x001c 120 120 000 Old_age Offline - 0/0
230 Life_Curve_Status 0x0013 100 100 000 Pre-fail Always - 100
231 SSD_Life_Left 0x0000 100 100 011 Old_age Offline - 64424509440
233 SandForce_Internal 0x0032 000 000 000 Old_age Always - 27
234 SandForce_Internal 0x0032 000 000 000 Old_age Always - 40
241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 40
242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 14
244 Unknown_Attribute 0x0000 100 100 010 Old_age Offline - 131072
SMART Error Log not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Smartctl for /dev/sde
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.9.14-200.fc25.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda Green (AF)
Device Model: ST1500DL003-9VT16L
Serial Number: 6YD20C55
LU WWN Device Id: 5 000c50 046c98ed8
Firmware Version: CC3C
User Capacity: 1,500,301,910,016 bytes [1.50 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5900 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is: Tue Apr 4 09:32:42 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 633) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 286) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x30b7) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 099 006 Pre-fail Always - 1033680
3 Spin_Up_Time 0x0003 096 092 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 328
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 071 060 030 Pre-fail Always - 133581685585
9 Power_On_Hours 0x0032 062 062 000 Old_age Always - 33964
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 274
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 098 098 000 Old_age Always - 2
188 Command_Timeout 0x0032 100 097 000 Old_age Always - 18
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 060 046 045 Old_age Always - 40 (Min/Max 40/41)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 283
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 329
194 Temperature_Celsius 0x0022 040 054 000 Old_age Always - 40 (0 18 0 0 0)
195 Hardware_ECC_Recovered 0x001a 010 003 000 Old_age Always - 1033680
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 33898 (246 129 0)
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 462706583
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 2921343414
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.