List of flags used in ebas
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
List of flags used in ebas | |
All flags are grouped in four categories: V (valid measurement), I (invalid measurement), M (missing measurement) or H (hidden and invalid measurements). | |
Flag V/I/H Description | |
Group 9: Missing flags | |
999 M Missing measurement, unspecified reason | |
990 M Precipitation not measured due to snow-fall. Needed for historic data, should not be needed for new data | |
980 M Missing due to calibration or zero/span check | |
900 H Hidden and invalidated by data originator | |
Group 8: Flags for undefined data elements | |
899 M Measurement undefined, unspecified reason | |
890 M Concentration in precipitation undefined, no precipitation | |
Group 7: Flags used when the value is unknown | |
799 I Measurement missing (unspecified reason), data element contains estimated value | |
798 V Measurement missing (unspecified reason), data element contains estimated value. Considered valid. | |
797 V Data element taken from co-located instrument | |
784 I Low precipitation, concentration estimated | |
783 M Low precipitation, concentration unknown | |
782 V Low precipitation, concentration estimated | |
781 V Value below detection limit, data element contains detection limit | |
780 V Value below detection or quantification limit, data element contains estimated or measured value. Use of flag 147 is encouraged. | |
771 V Value above range, data element contains upper range limit | |
770 V Value above range, data element contains estimated value | |
760 V Value estimated by summing up the constituents measured | |
750 M H+ not measured in alkaline sample | |
741 V Non refractory AMS concentrations. Don't include compounds that volatalises above 600 deg C | |
740 V Probably biased gas/particle ratio | |
701 I Less accurate than usual, unspecified reason. (Used only with old data, for new data see groups 6 and 5) | |
Group 6: Mechanical or instrumental problem | |
699 I Mechanical problem, unspecified reason | |
682 I Invalid due to calibration or zero/span check | |
681 I Low data capture | |
680 V Undefined wind direction | |
679 V Unspecified meteorological condition | |
678 V Hurricane | |
677 I Icing or hoar frost in the intake | |
676 V station inside cloud (visibility < 1000 m) | |
675 V no visibility data available | |
674 V Icing or hoar frost in the intake, considered valid | |
670 I Incomplete data acquisition for multi-component data sets | |
669 I Moist or wet filter, invalid | |
668 V Moist or wet filter, valid | |
666 I Filter damaged, invalid | |
665 V Filter damaged, valid | |
664 I Instrument flow(s) too far off target value, considered invalid | |
663 I Too high sampling flow, data considered invalid | |
662 V Too high sampling flow, data considered valid | |
660 V Unspecified sampling anomaly, considered valid | |
659 I Unspecified sampling anomaly | |
658 I Too small air volume | |
657 V Precipitation collector overflow. Heavy snowfall/rain shower (squall) | |
656 V Wet-only collector failure, operated as bulk collector | |
655 V Estimated value created by averaging or splitting samples | |
654 V Sampling period longer than normal, considered representative. Observed values reported | |
653 V Sampling period shorter than normal, considered representative. Observed values reported | |
652 V Construction/acitivity nearby | |
651 V Agricultural activity nearby | |
650 V Precipitation collector failure | |
649 V Temporary power fail has affected sampler operation | |
648 V Snow sampler | |
647 V Fire/wood burning nearby | |
646 I Exceptional traffic nearby | |
645 V Exceptional traffic nearby | |
644 V Low instrument precision and/or calibration issues | |
641 I Aerosol filters installed incorrectly | |
640 V Instrument internal relative humidity above 40% | |
635 I Internal temperatures too far off target value, considered invalid | |
632 V Lid of polyurethane foam (PUF) sampler not closed | |
630 V POP concentration from the polyurethane foam (PUF) only | |
Group 5: Chemical problem | |
599 I Unspecified contamination or local influence | |
593 I Industrial contamination, considered invalid | |
591 I Agricultural contamination, considered invalid | |
578 I Large sea salt contribution (ratio between marine and excess sulphate is larger than 2.0). Used for old data only. For newer data use 451/450. | |
568 I Dust contamination, considered invalid | |
567 I Insect contamination, considered invalid | |
566 I Bird droppings, considered invalid | |
565 I Pollen and/or leaf contamination, considered invalid | |
559 V Unspecified contamination or local influence, but considered valid | |
558 V Dust contamination, but considered valid | |
557 V Insect contamination, but considered valid | |
556 V Bird droppings, but considered valid | |
555 V Pollen and/or leaf contamination, but considered valid | |
549 I Impure chemicals | |
541 I Gold trap passiviated by unknown compound | |
540 I Spectral interference in laboratory analysis | |
534 I Wrong coated denuder used | |
533 I Filters mixed up; incorrect analysis | |
532 V Data less accurate than normal due to high field blank value | |
531 V Low recovery, analysis inaccurate | |
530 I Invalid due to too low or too high recovery | |
521 V Bactericide was added to sample for storage under warm climate. Considered valid | |
Group 4: Extreme or inconsistent values | |
499 V Inconsistent with another unspecified measurement | |
498 V Gold trap inconsistency in mercury monitor | |
478 I Invalid due to inconsistency discovered through ion balance calculations | |
477 I Invalid due to inconsistency between measured and estimated conductivity | |
476 V Inconsistency discovered through ion balance calculations, but considerd valid | |
475 V Inconsistency between measured and estimated conductivity, but considerd valid | |
471 I Particulate mass concentration higher than parallell mass concentration measurement with higher cut off | |
i.e PM1_mass > PM25_mass and PM25_mass > PM10_mass. Considered invalid. | |
470 V Particulate mass concentration higher than parallell mass concentration measurement with higher cut off | |
i.e PM1_mass > PM25_mass and PM25_mass > PM10_mass | |
460 I Contamination suspected | |
459 I Extreme value, unspecified error | |
458 V Extremely high value, outside four times standard deviation in a lognormal distribution | |
457 V Extremely low value, outside four times standard deviation in a lognormal distribution | |
456 I Invalidated by data originator | |
452 I Invalid due to large uncertainty | |
451 I Invalid due to large sea salt contribution | |
450 V Considerable sea salt contribution, but considered valid | |
440 V Reconstructed or recalculated data | |
420 V Preliminary data | |
410 V Sahara dust event | |
Group 3: Flags for aggregated datasets | |
395 I Data completeness less than 90% | |
394 V Data completeness less than 90% | |
393 I Data completeness less than 75% | |
392 V Data completeness less than 75% | |
391 I Data completeness less than 50% | |
390 V Data completeness less than 50% | |
382 V More than 75% of the measurements are below detection limit | |
380 V More than 50% of the measurements are below detection limit | |
370 V For monthly averages with samples partly in two months, the number of days in each month is used for weighing the sample | |
Group 2: Exception flags assigned by the database co-ordinator | |
299 V Inconsistent with another unspecified measurement | |
298 V Gold trap inconsistency in mercury monitor | |
278 I Invalid due to inconsistency discovered through ion balance calculations | |
277 I Invalid due to inconsistency between measured and estimated conductivity | |
276 V Inconsistency discovered through ion balance calculations, but considered valid | |
275 V Inconsistency between measured and estimated conductivity, but considered valid | |
260 I Contamination suspected | |
259 I Unspecified error expected | |
258 V Extremely high value, outside four times standard deviation in a log-normal distribution | |
257 V Extremely low value, outside four times standard deviation in a log-normal distribution | |
256 I Invalidated by database co-ordinator | |
251 I Invalid due to large sea salt contribution | |
250 V Considerable sea salt contribution, but considered valid | |
249 V Apparent typing error corrected. Valid measurement | |
248 V Illegal flag was removed by the database co-ordinator. Lost flag information (used for historic data only). | |
247 V Overlapping sample interval was corrected by the database co-ordinator. Possible wrong sample time (used for historic data only) | |
220 V Preliminary data | |
211 V Irregular data checked and accepted by database co-ordinator. Valid measurement | |
210 V Episode data checked and accepted by database co-ordinator. Valid measurement | |
Group 1: Exception flags for accepted, irregular data | |
191 V Data not truncation corrected - Valid measurement | |
190 V Not corrected for cross-sensitivity to particle scattering | |
189 V Possible local contamination indicated by wind from contaminated sector (auto) | |
188 V Possible local contamination indicated by low wind speed (auto) | |
187 V Possible local contamination indicated by occurence of new particles (auto) | |
186 V Possible local contamination indicated by single scattering albedo (auto) | |
185 V Possible local contamination indicated by wind direction or velocity | |
147 V Below theoretical detection limit or formal Q/A limit, but a value has been measured and reported and is considered valid | |
120 V Sample reanalysed with similar results. Valid measurement | |
111 V Irregular data checked and accepted by data originator. Valid measurement | |
110 V Episode data checked and accepted by data originator. Valid measurement | |
103 V CV of replicate ALPHA samplers > 15 %;. Valid measurement | |
102 V CV of replicate diffusion tubes > 30 %. Valid measurement | |
101 V Denuder capture efficiency < 75%. Valid measurement | |
100 V Checked by data originator. Valid measurement | |
Group 0: Valid data | |
000 V Valid measurement |