Skip to content

Instantly share code, notes, and snippets.

@rm-you
Created February 1, 2017 01:10
Show Gist options
  • Save rm-you/4e91110b008213b818f22150f17ef612 to your computer and use it in GitHub Desktop.
Save rm-you/4e91110b008213b818f22150f17ef612 to your computer and use it in GitHub Desktop.
Failure to recycle a bad spares-pool amphora (stopped agent)
2017-01-31 18:05:44.759 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.ReloadLoadBala
ncer' (fce3a2d3-150d-427f-9937-b7da71f0706d) transitioned into state 'SUCCESS' from state 'RUNNING' with result 'None' _task_receiver /opt/octavia/env/
lib/python2.7/site-packages/taskflow/listeners/logging.py:183
2017-01-31 18:05:44.765 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.network_tasks.GetAmphoraeNetw
orkConfigs' (118f2574-48c8-47bc-80c7-7183c8e87c4a) transitioned into state 'RUNNING' from state 'PENDING' _task_receiver /opt/octavia/env/lib/python2.7
/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.766 32227 DEBUG octavia.controller.worker.tasks.network_tasks [-] Retrieving vip network details. execute /opt/octavia/env/lib/pyth
on2.7/site-packages/octavia/controller/worker/tasks/network_tasks.py:378
2017-01-31 18:05:44.785 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.network_tasks.GetAmphoraeNe
tworkConfigs' (118f2574-48c8-47bc-80c7-7183c8e87c4a) transitioned into state 'FAILURE' from state 'RUNNING'
40 predecessors (most recent first):
Atom 'octavia.controller.worker.tasks.database_tasks.ReloadLoadBalancer' {'intention': 'EXECUTE', 'state': 'SUCCESS', 'requires': {'loadbalancer_id':
None}, 'provides': None}
|__Atom 'octavia.controller.worker.tasks.database_tasks.UpdateAmpFailoverDetails' {'intention': 'EXECUTE', 'state': 'SUCCESS', 'requires': {'amphora'
: <octavia.common.data_models.Amphora object at 0x7f65f4c0f450>, 'amp_data': <octavia.common.data_models.Amphora object at 0x7f65f4c15e90>}, 'provides'
: None}
|__Atom 'octavia-failover-amphora-flow-octavia-post-map-amp-to-lb-subflow-octavia-mark-amp-standalone-indb' {'intention': 'EXECUTE', 'state': 'SUC
CESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x7f65f4c0f450>}, 'provides': None}
| |__Atom 'octavia-failover-amphora-flow-octavia-post-map-amp-to-lb-subflow-octavia-reload-amphora' {'intention': 'EXECUTE', 'state': 'SUCCESS',
'requires': {'amphora_id': u'e3436086-719e-4fa3-8821-16f24144ca22'}, 'provides': <octavia.common.data_models.Amphora object at 0x7f65f4c0f450>}
| |__Flow 'octavia-failover-amphora-flow-octavia-post-map-amp-to-lb-subflow'
| |__Atom 'octavia-failover-amphora-flow-octavia-get-amphora-for-lb-subflow-octavia-mapload-balancer-to-amphora' {'intention': 'EXECUTE', '
state': 'SUCCESS', 'requires': {'loadbalancer_id': None}, 'provides': u'e3436086-719e-4fa3-8821-16f24144ca22'}
| |__Flow 'octavia-failover-amphora-flow-octavia-get-amphora-for-lb-subflow'
| |__Atom 'octavia.controller.worker.tasks.database_tasks.GetAmphoraDetails' {'intention': 'EXECUTE', 'state': 'SUCCESS', 'requires':
{'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': <octavia.common.data_models.Amphora object at 0x7f65f4c15e90>}
| |__Atom 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraDeletedInDB' {'intention': 'EXECUTE', 'state': 'SUCCESS', 're
quires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
| |__Atom 'octavia.controller.worker.tasks.database_tasks.DisableAmphoraHealthMonitoring' {'intention': 'EXECUTE', 'state': 'SU
CCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
| |__Atom 'octavia.controller.worker.tasks.network_tasks.WaitForPortDetach' {'intention': 'EXECUTE', 'state': 'SUCCESS', 're
quires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
| |__Atom 'octavia.controller.worker.tasks.compute_tasks.ComputeDelete' {'intention': 'EXECUTE', 'state': 'SUCCESS', 'req
uires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
| |__Atom 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraHealthBusy' {'intention': 'EXECUTE', 'state': 'SU
CCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
| |__Atom 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraPendingDeleteInDB' {'intention': 'EXECUTE', 's
tate': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
| |__Atom 'octavia.controller.worker.tasks.lifecycle_tasks.AmphoraToErrorOnRevertTask' {'intention': 'EXECUTE',
'state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
| |__Flow 'octavia-failover-amphora-flow'
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-mark-amp-standalone-indb' {'intention': 'IGNORE', 'state': 'IGNOR
E'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-reload-amphora' {'intention': 'IGNORE', 'state': 'IGNORE', 're
quires': {'amphora_id': u'e3436086-719e-4fa3-8821-16f24144ca22'}}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-mark-amphora-allocated-indb' {'intention': 'IGNORE', 'state
': 'IGNORE'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-amphora-finalize' {'intention': 'IGNORE', 'state': 'IGNO
RE'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-update-amphora-info' {'intention': 'IGNORE', 'state':
'IGNORE'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-compute-wait' {'intention': 'IGNORE', 'state': 'IG
NORE'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-mark-amphora-booting-indb' {'intention': 'IGNOR
E', 'state': 'IGNORE'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-update-amphora-computeid' {'intention': 'IGN
ORE', 'state': 'IGNORE'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-cert-compute-create' {'intention': 'IGNOR
E', 'state': 'IGNORE'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-update-cert-expiration' {'intention':
'IGNORE', 'state': 'IGNORE'}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-generate-serverpem' {'intention': '
IGNORE', 'state': 'IGNORE', 'requires': {'amphora_id': u'e3436086-719e-4fa3-8821-16f24144ca22'}}
|__Atom 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow-octavia-create-amphora-indb' {'intention
': 'IGNORE', 'state': 'IGNORE', 'requires': {}}
|__Flow 'octavia-failover-amphora-flow-octavia-create-amp-for-lb-subflow'
|__Atom 'octavia-failover-amphora-flow-octavia-get-amphora-for-lb-subflow-octavia-mapload-balancer-to-ampho
ra' {'intention': 'EXECUTE', 'state': 'SUCCESS', 'requires': {'loadbalancer_id': None}, 'provides': u'e3436086-719e-4fa3-8821-16f24144ca22'}
|__Flow 'octavia-failover-amphora-flow-octavia-get-amphora-for-lb-subflow'
|__Atom 'octavia.controller.worker.tasks.database_tasks.GetAmphoraDetails' {'intention': 'EXECUTE', '
state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': <octavia.common.data_models.Amphora o
bject at 0x7f65f4c15e90>}
|__Atom 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraDeletedInDB' {'intention': 'EXE
CUTE', 'state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
|__Atom 'octavia.controller.worker.tasks.database_tasks.DisableAmphoraHealthMonitoring' {'inten
tion': 'EXECUTE', 'state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
|__Atom 'octavia.controller.worker.tasks.network_tasks.WaitForPortDetach' {'intention': 'EXE
CUTE', 'state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
|__Atom 'octavia.controller.worker.tasks.compute_tasks.ComputeDelete' {'intention': 'EXEC
UTE', 'state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
|__Atom 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraHealthBusy' {'inten
tion': 'EXECUTE', 'state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
|__Atom 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraPendingDeleteInD
B' {'intention': 'EXECUTE', 'state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
|__Atom 'octavia.controller.worker.tasks.lifecycle_tasks.AmphoraToErrorOnRevertT
ask' {'intention': 'EXECUTE', 'state': 'SUCCESS', 'requires': {'amphora': <octavia.common.data_models.Amphora object at 0x402df10>}, 'provides': None}
|__Flow 'octavia-failover-amphora-flow'
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker Traceback (most recent call last):
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker File "/opt/octavia/env/lib/python2.7/site-packages/taskflow/engines/a
ction_engine/executor.py", line 53, in _execute_task
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker result = task.execute(**arguments)
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker File "/opt/octavia/env/lib/python2.7/site-packages/octavia/controller
/worker/tasks/network_tasks.py", line 379, in execute
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker return self.network_driver.get_network_configs(loadbalancer)
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker File "/opt/octavia/env/lib/python2.7/site-packages/octavia/network/dr
ivers/neutron/allowed_address_pairs.py", line 529, in get_network_configs
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker vip_subnet = self.get_subnet(loadbalancer.vip.subnet_id)
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker AttributeError: 'NoneType' object has no attribute 'vip'
2017-01-31 18:05:44.785 32227 ERROR octavia.controller.worker.controller_worker
2017-01-31 18:05:44.804 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.network_tasks.GetAmphoraeNetw
orkConfigs' (118f2574-48c8-47bc-80c7-7183c8e87c4a) transitioned into state 'REVERTING' from state 'FAILURE' _task_receiver /opt/octavia/env/lib/python2
.7/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.806 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.network_tasks.GetAmphoraeNe
tworkConfigs' (118f2574-48c8-47bc-80c7-7183c8e87c4a) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.811 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.ReloadLoadBala
ncer' (fce3a2d3-150d-427f-9937-b7da71f0706d) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/python2.7/sit
e-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.813 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.ReloadLoadBa
lancer' (fce3a2d3-150d-427f-9937-b7da71f0706d) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.817 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.UpdateAmpFailo
verDetails' (cfa76834-b44a-43a2-99e8-b48d9ca16756) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/python2
.7/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.819 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.UpdateAmpFai
loverDetails' (cfa76834-b44a-43a2-99e8-b48d9ca16756) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.824 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia-failover-amphora-flow-octavia-post-map-amp-to-lb-subf
low-octavia-mark-amp-standalone-indb' (eac74892-4dc4-4a8a-8f5b-af6dc2b803c1) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /o
pt/octavia/env/lib/python2.7/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.825 32227 WARNING octavia.controller.worker.tasks.database_tasks [-] Reverting amphora role in DB for amp id e3436086-719e-4fa3-882
1-16f24144ca22
2017-01-31 18:05:44.831 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia-failover-amphora-flow-octavia-post-map-amp-to-lb-su
bflow-octavia-mark-amp-standalone-indb' (eac74892-4dc4-4a8a-8f5b-af6dc2b803c1) transitioned into state 'REVERTED' from state 'REVERTING' with result 'N
one'
2017-01-31 18:05:44.834 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia-failover-amphora-flow-octavia-post-map-amp-to-lb-subf
low-octavia-reload-amphora' (89a2f059-1825-4195-abe6-5a0f8441b1d4) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia
/env/lib/python2.7/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.836 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia-failover-amphora-flow-octavia-post-map-amp-to-lb-su
bflow-octavia-reload-amphora' (89a2f059-1825-4195-abe6-5a0f8441b1d4) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.840 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia-failover-amphora-flow-octavia-get-amphora-for-lb-subf
low-octavia-mapload-balancer-to-amphora' (13ae0540-2526-46b0-baca-c4e378ecf731) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver
/opt/octavia/env/lib/python2.7/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.841 32227 WARNING octavia.controller.worker.tasks.database_tasks [-] Reverting Amphora allocation for the load balancer None in the
database.
2017-01-31 18:05:44.846 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia-failover-amphora-flow-octavia-get-amphora-for-lb-su
bflow-octavia-mapload-balancer-to-amphora' (13ae0540-2526-46b0-baca-c4e378ecf731) transitioned into state 'REVERTED' from state 'REVERTING' with result
'None'
2017-01-31 18:05:44.850 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.GetAmphoraDeta
ils' (8781aa37-a005-41e7-ae1d-85981fa59fce) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/python2.7/site
-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.851 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.GetAmphoraDe
tails' (8781aa37-a005-41e7-ae1d-85981fa59fce) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.855 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraDel
etedInDB' (042dd2d5-eb6b-467a-8549-93e99dd72a0e) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/python2.7
/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.856 32227 WARNING octavia.controller.worker.tasks.database_tasks [-] Reverting mark amphora deleted in DB for amp id 304e42d0-d0d3-
42f6-82b7-5b3e98f67cc9 and compute id 74c45224-734f-4244-b0b4-81017d668cfa
2017-01-31 18:05:44.862 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraD
eletedInDB' (042dd2d5-eb6b-467a-8549-93e99dd72a0e) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.867 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.DisableAmphora
HealthMonitoring' (11a1cf70-8469-40d9-bac8-4de52dd59211) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/p
ython2.7/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.870 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.DisableAmpho
raHealthMonitoring' (11a1cf70-8469-40d9-bac8-4de52dd59211) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.875 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.network_tasks.WaitForPortDeta
ch' (1ca672b9-a4b7-436f-a3f5-55052676275e) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/python2.7/site-
packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.877 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.network_tasks.WaitForPortDe
tach' (1ca672b9-a4b7-436f-a3f5-55052676275e) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.881 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.compute_tasks.ComputeDelete'
(e2f34cc8-5287-42b7-aedf-ab76a6f90229) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/python2.7/site-pack
ages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.883 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.compute_tasks.ComputeDelete
' (e2f34cc8-5287-42b7-aedf-ab76a6f90229) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.886 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraHea
lthBusy' (a0ed8368-53fd-4d99-91a5-59cc1cdd34c9) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/python2.7/
site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.888 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraH
ealthBusy' (a0ed8368-53fd-4d99-91a5-59cc1cdd34c9) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.892 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraPen
dingDeleteInDB' (119b9be8-da02-4137-a5e0-7ba1edf9dbdb) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/pyt
hon2.7/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.893 32227 WARNING octavia.controller.worker.tasks.database_tasks [-] Reverting mark amphora pending delete in DB for amp id 304e42d
0-d0d3-42f6-82b7-5b3e98f67cc9 and compute id 74c45224-734f-4244-b0b4-81017d668cfa
2017-01-31 18:05:44.900 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.database_tasks.MarkAmphoraP
endingDeleteInDB' (119b9be8-da02-4137-a5e0-7ba1edf9dbdb) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.904 32227 DEBUG octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.lifecycle_tasks.AmphoraToErro
rOnRevertTask' (cd316c21-b750-47f8-99c2-392c08aaa0d8) transitioned into state 'REVERTING' from state 'SUCCESS' _task_receiver /opt/octavia/env/lib/pyth
on2.7/site-packages/taskflow/listeners/logging.py:194
2017-01-31 18:05:44.911 32227 WARNING octavia.controller.worker.controller_worker [-] Task 'octavia.controller.worker.tasks.lifecycle_tasks.AmphoraToEr
rorOnRevertTask' (cd316c21-b750-47f8-99c2-392c08aaa0d8) transitioned into state 'REVERTED' from state 'REVERTING' with result 'None'
2017-01-31 18:05:44.925 32227 WARNING octavia.controller.worker.controller_worker [-] Flow 'octavia-failover-amphora-flow' (23aed5b6-2ef5-428f-a3ad-546
5f438ae7a) transitioned into state 'REVERTED' from state 'RUNNING'
2017-01-31 18:05:44.925 32227 ERROR octavia.controller.worker.controller_worker [-] Failover exception: 'NoneType' object has no attribute 'vip'
2017-01-31 18:05:45.543 32227 DEBUG octavia.controller.healthmanager.health_manager [-] Starting amphora health check health_check /opt/octavia/env/lib
/python2.7/site-packages/octavia/controller/healthmanager/health_manager.py:46
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment