Save serrj-sv/af142b25de2d7ac54c3a2eb2623d9a6d to your computer and use it in GitHub Desktop.
MoesHouse Tuya SH4 radiator valve eTRV thermostat zigbee2mqtt external converter
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
const fz = require('zigbee-herdsman-converters/converters/fromZigbee'); | |
const tz = require('zigbee-herdsman-converters/converters/toZigbee'); | |
const exposes = require('zigbee-herdsman-converters/lib/exposes'); | |
const reporting = require('zigbee-herdsman-converters/lib/reporting'); | |
const extend = require('zigbee-herdsman-converters/lib/extend'); | |
const e = exposes.presets; | |
const ea = exposes.access; | |
const tuya = require('zigbee-herdsman-converters/lib/tuya'); | |
const { duration } = require('moment'); | |
const localValueConverter = { | |
divideBy2: tuya.valueConverterBasic.divideBy(2), | |
thermostatHolidayStartStop_SH4: { | |
from: (v) => { | |
start_year = v[0]+2000; | |
start_month = v[1] < 10 ? '0'+v[1] : v[1]; | |
start_day = v[2] < 10 ? '0'+v[2] : v[2]; | |
start_hour = v[3] < 10 ? '0'+v[3] : v[3]; | |
start_minute = v[4] < 10 ? '0'+v[4] : v[4]; | |
temperature = (v[5] /2).toFixed(1); | |
away_hours = v[6]<< 8 | v[7]; | |
return `${start_day}/${start_month}/${start_year} ${start_hour}:${start_minute} ${away_hours} ${temperature}`; | |
}, | |
to: (v) => { | |
const output = []; | |
holiday_schedule = v.split(' '); | |
[start_day, start_month, start_year] = holiday_schedule[0].split('/'); | |
[start_hour, start_minute] = holiday_schedule[1].split(':') | |
away_hours = holiday_schedule[2]; | |
temperature = holiday_schedule[3]; | |
output[0]=start_year > 2000 ? start_year-2000 : start_year; | |
output[1]=start_month; | |
output[2]=start_day; | |
output[3]=start_hour; | |
output[4]=start_minute; | |
output[5]=Math.round(temperature * 2); | |
output[7]=away_hours & 0xFF; | |
output[6]=away_hours >> 8; | |
return output; | |
}, | |
}, | |
} | |
const definition = { | |
fingerprint: tuya.fingerprint('TS0601', [ | |
'_TZE200_fhn3negr', /* model: 'SH4-ZB', vendor: 'Moes' */ | |
]), | |
model: 'SH4-ZB', | |
vendor: 'TuYa', | |
description: 'Thermostat radiator valve', | |
fromZigbee: [tuya.fz.datapoints], | |
toZigbee: [tuya.tz.datapoints], | |
// ota: ota.zigbeeOTA, | |
onEvent: tuya.onEventSetLocalTime, | |
configure: tuya.configureMagicPacket, | |
exposes: [ | |
e.battery(), e.child_lock(), e.open_window(), | |
e.open_window_temperature().withValueMin(5).withValueMax(30), | |
e.comfort_temperature().withValueMin(5).withValueMax(30), | |
e.eco_temperature().withValueMin(5).withValueMax(30), | |
e.numeric('auto_setpoint_override', ea.STATE_SET) | |
.withUnit('°C').withValueMax(30) | |
.withValueMin(0.5) | |
.withValueStep(0.5) | |
.withDescription('Setpoint override in auto mode'), | |
e.climate() | |
.withPreset(['auto', 'manual', 'holiday']) | |
.withLocalTemperatureCalibration(-5, 5, 0.1, ea.STATE_SET) | |
.withLocalTemperature(ea.STATE) | |
.withSetpoint('current_heating_setpoint', 0, 30, 0.5, ea.STATE_SET), | |
// .withSystemMode(['off', 'heat'], ea.STATE_SET, 'Only for Homeassistant'), | |
e.binary('online', ea.STATE_SET, 'ON', 'OFF') | |
.withDescription('The current data request from the device.'), | |
e.binary('boost_heating', ea.STATE_SET, 'ON', 'OFF') | |
.withDescription('Boost Heating: the device will enter the boost heating mode.'), | |
e.numeric('boost_timeset_countdown', ea.STATE_SET).withUnit('s').withDescription('Setting ' + | |
'minimum 0 - maximum 900 seconds boost time. The boost (â¨) function is activated. The remaining ' + | |
'time for the function will be counted down in seconds ( 900 to 0 ).').withValueMin(0).withValueMax(900), | |
e.numeric('window_detection', ea.STATE_SET).withUnit('m').withDescription('Open Window timer').withValueMin(0).withValueMax(60), | |
e.text('holiday_start_stop', ea.STATE_SET).withDescription('The holiday mode will automatically start ' + | |
'at the set time starting point and run the holiday temperature. Can be defined in the following format: ' + | |
'`DD/MM/YYYY HH:MM HHHH TT.T`. ' + | |
'For example: `01/10/2022 16:30 0240 18` (240 hours = 10 days). After the end of holiday mode, it switches to "auto" ' + | |
'mode and uses schedule.'), | |
tuya.exposes.errorStatus() | |
], | |
meta: { | |
tuyaDatapoints: [ | |
// GitHib issue: https://github.com/Koenkk/zigbee-herdsman-converters/issues/1803 | |
// sniffing eTRV -> Gateway: https://gist.github.com/serrj-sv/964d390139534754b6ea22f628b33c61 | |
// sniffing Gateway -> eRTV: https://gist.github.com/serrj-sv/e6680647c438221b190a2b4d96805cc4 | |
// legacy exteranl converter: https://gist.github.com/serrj-sv/af142b25de2d7ac54c3a2eb2623d9a6d | |
[2, 'preset', tuya.valueConverterBasic.lookup({'auto': tuya.enum(0), 'manual': tuya.enum(1), 'holiday': tuya.enum(2)})], | |
[16, 'current_heating_setpoint', localValueConverter.divideBy2], | |
[24, 'local_temperature', tuya.valueConverter.divideBy10], | |
[30, 'child_lock', tuya.valueConverter.lockUnlock], | |
[34, 'battery', tuya.valueConverterBasic.scale(0, 100, 50, 150)], | |
[45, 'error_status', tuya.valueConverter.raw], | |
[101, 'comfort_temperature', localValueConverter.divideBy2], | |
[102, 'eco_temperature', localValueConverter.divideBy2], | |
[103, 'holiday_start_stop', localValueConverter.thermostatHolidayStartStop_SH4], // sh4VacationPeriod | |
[104, 'local_temperature_calibration', tuya.valueConverter.localTempCalibration1], | |
[106, 'boost_heating', tuya.valueConverter.onOff], | |
[105, 'auto_setpoint_override', localValueConverter.divideBy2], | |
[107, 'open_window', tuya.valueConverter.onOff], | |
[108, null, null], // sh4Hibernate (don't know what it does) | |
[109, null, null], // sh4ScheduleMon - WIP | |
[110, null, null], // sh4ScheduleTue - WIP | |
[111, null, null], // sh4ScheduleWed - WIP | |
[112, null, null], // sh4ScheduleThu - WIP | |
[113, null, null], // sh4ScheduleFri - WIP | |
[114, null, null], // sh4ScheduleSat - WIP | |
[115, null, null], // sh4ScheduleSun - WIP | |
[116, 'open_window_temperature', localValueConverter.divideBy2], | |
[117, 'window_detection', tuya.valueConverter.raw], // sh4OpenWindowTime | |
[118, 'boost_timeset_countdown', tuya.valueConverter.raw], | |
[119, null, null], // sh4TempControl (don't know what it does) | |
[120, 'online', tuya.valueConverter.onOffNotStrict], | |
], | |
}, | |
}; | |
module.exports = definition; |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
I rewrote my converter from scratch to not use legacy calls and it covers 95% of functionality. I used this model as prototype: https://github.com/Koenkk/zigbee-herdsman-converters/blob/9b1fda43a95381b3becf343c64a5a05a8f3e29db/src/devices/tuya.ts#L2846