[{"arr": "52,01,03,01,B6,FF,01,00,FF,FF,02,00,FF,FF,03,00,FF,FF,06,00,43,20,07,00,FF,FF#", "data": "{\"screen\":\"Sensor\",\"data\":[{\"Key\":\"ReturnAirTemperatureSensor\",\"Value\":\"-\",\"display_name\":\"Return Air Temp\",\"description\":\"The temperature of the air detected at the unit air return sensor. When replacing temperature sensor use only Goodman/Amana approved sensor. Use of invalid sensors will lead to inaccurate temperature readings.\",\"value_unit\":\"F\",\"visible\":\"Hide\"},{\"Key\":\"SupplyAirTemperatureSensor\",\"Value\":\"-\",\"display_name\":\"Supply Air Temp\",\"description\":\"The temperature of the air detected at the unit air supply sensor. When replacing temperature sensor use only Goodman/Amana approved sensor. Use of invalid sensors will lead to inaccurate temperature readings.\",\"value_unit\":\"F\",\"visible\":\"Hide\"},{\"Key\":\"OutdoorAmbientTemperature\",\"Value\":\"-\",\"display_name\":\"Outdoor Temp\",\"description\":\"Outdoor ambient temperature measured by an outdoor temperature sensor. If an unusual temperature is displayed, this feature may not available on this unit. (degrees F)\",\"value_unit\":\"F\",\"visible\":\"Hide\"},{\"Key\":\"OnboardTemperatureSensor\",\"Value\":82.59,\"display_name\":\"Control Board Temperature\",\"description\":\"The temperature reported by the integrated temperature sensor located on the control board inside the unit\",\"value_unit\":\"F\",\"visible\":\"Show\"},{\"Key\":\"ReturnSupplyTempDelta\",\"Value\":\"-\",\"display_name\":\"Supply Temp - Return Temp Delta\",\"description\":\"The difference between the return temperature and the supply temperature. Will be negative when the system is cooling and positive when the system is heating.\",\"value_unit\":\"F\",\"visible\":\"Hide\"}]}"},
{"arr": "54,01,03,01,B6,FF,01,00,DC,1E,02,00,FF,FF,03,00,FF,FF,04,00,FF,FF,05,00,FF,FF,06,00,FF,FF,07,00,FF,FF,08,00,FF,FF,09,00,FF,FF,0A,00,FF,FF#", "data": "{\"screen\":\"Sensor\",\"data\":[{\"Key\":\"OutdoorAmbientTemperature\",\"Value\":79,\"display_name\":\"Outdoor Temp\",\"description\":\"Outdoor ambient temperature measured by an outdoor temperature sensor. If an unusual temperature is displayed, this feature may not available on this unit. (degrees F)\",\"value_unit\":\"F\",\"visible\":\"Show\"},{\"Key\":\"CoilTemperature\",\"Value\":\"-\",\"display_name\":\"Coil Temp\",\"description\":\"Current temperature of the outdoor coil (degrees F)\",\"value_unit\":\"F\",\"visible\":\"Hide\"},{\"Key\":\"LiquidLineTemperature\",\"Value\":\"-\",\"display_name\":\"Liquid Line Temp\",\"description\":\"Current temperature of the liquid line. (degrees F)\",\"value_unit\":\"F\",\"visible\":\"Hide\"},{\"Key\":\"DischargeTemperature\",\"Value\":\"-\",\"display_name\":\"Discharge Temp\",\"description\":\"Current compressor discharge temperature (degrees F)\",\"value_unit\":\"F\",\"visible\":\"Hide\"},{\"Key\":\"OutdoorDefrostSensorTemperature\",\"Value\":\"-\",\"display_name\":\"Defrost Sensor\",\"description\":\"Current temperature read by the outdoor Defrost Sensor. Temperature is used to determine when to enter / exit a defrost cycle (degrees F)\",\"value_unit\":\"F\",\"visible\":\"Hide\"},{\"Key\":\"SuctionTemperature\",\"Value\":\"-\",\"display_name\":\"Suction Temp\",\"description\":\"The Suction Temperature is the line temperature as the refrigerant is returned to the compressor. (degrees F)\",\"value_unit\":\"F\",\"visible\":\"Hide\"},{\"Key\":\"SuctionPressure\",\"Value\":\"-\",\"display_name\":\"Suction Pressure\",\"description\":\"The Suction Pressure is the intake pressure generated by the system's compressor while operating. (PSI)\",\"value_unit\":\"PSI\",\"visible\":\"Hide\"},{\"Key\":\"DischargePressure\",\"Value\":\"-\",\"display_name\":\"Discharge Pressure\",\"description\":\"Discharge Pressure is the pressure generated on the output side of the compressor in a refrigeration or air conditioning system. (PSI)\",\"value_unit\":\"PSI\",\"visible\":\"Hide\"},{\"Key\":\"CurrentSensor#1Reading\",\"Value\":\"-\",\"display_name\":\"Sensor #1\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"CurrentSensor#2Reading\",\"Value\":\"-\",\"display_name\":\"Sensor #2\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"}]}"},
{"arr": "52,01,03,01,B4,FF,01,00,46,46,02,00,46,46,03,00,46,46,04,00,46,46,05,00,46,46,06,00,62,31,07,00,62,31,08,00,45,64,09,00,45,64,0A,00,45,64,0B,00,62,31#", "data": "{\"screen\":\"Diagnostic\",\"data\":[{\"Key\":\"1stAlarminLast6Fault\",\"Value\":\"b1\"},{\"Key\":\"2ndAlarminLast6Fault\",\"Value\":\"b1\"},{\"Key\":\"3rdAlarminLast6Fault\",\"Value\":\"Ed\"},{\"Key\":\"4thAlarminLast6Fault\",\"Value\":\"Ed\"},{\"Key\":\"5thAlarminLast6Fault\",\"Value\":\"Ed\"},{\"Key\":\"6thAlarminLast6Fault\",\"Value\":\"b1\"}]}"},
{"arr": "54,01,03,01,B4,FF,01,00,30,38,02,00,30,38,03,00,46,46,04,00,46,46,05,00,46,46,06,00,30,38,07,00,45,35,08,00,45,35,09,00,45,35,0A,00,45,35,0B,00,45,35#", "data": "{\"screen\":\"Diagnostic\",\"data\":[{\"Key\":\"AlarmBeingProcessed\",\"Value\":\"08\"},{\"Key\":\"1stActiveAlarm\",\"Value\":\"08\"},{\"Key\":\"1stAlarminLast6Fault\",\"Value\":\"08\"},{\"Key\":\"2ndAlarminLast6Fault\",\"Value\":\"E5\"},{\"Key\":\"3rdAlarminLast6Fault\",\"Value\":\"E5\"},{\"Key\":\"4thAlarminLast6Fault\",\"Value\":\"E5\"},{\"Key\":\"5thAlarminLast6Fault\",\"Value\":\"E5\"},{\"Key\":\"6thAlarminLast6Fault\",\"Value\":\"E5\"}]}"},
{"arr": "52,01,03,01,B1,FF,01,00,04,00,C8,3C,C8,14,03,00,04,00,DC,B4,DC,CC,04,00,04,00,AE,A2,C8,02,07,00,04,00,8C,6E,AA,02,0B,00,04,00,1E,05,1E,05,0C,00,04,00,5A,1E,B4,1E,12,00,04,00,01,01,02,01,13,00,04,00,01,00,01,01,0F,00,04,00,01,00,01,01#", "data": "{\"screen\":\"Setting\",\"data\":[{\"Value\":\"100.0\",\"options\":\"30.0[-*-]40.0[-*-]50.0[-*-]60.0[-*-]70.0[-*-]80.0[-*-]90.0[-*-]100.0\",\"Key\":\"FanOnlyMultiplierPercent\",\"display_name\":\"Constant Fan Airflow Multiplier\",\"description\":\"Percentage of maximum indoor airflow that will be delivered during a thermostat G call for fan only.\",\"value_unit\":\"%\",\"visible\":\"Show\"},{\"Value\":\"10\",\"options\":\"-10[-*-]-8[-*-]-6[-*-]-4[-*-]-2[-*-]0[-*-]2[-*-]4[-*-]6[-*-]8[-*-]10\",\"Key\":\"GasHeatTrimFactorPercent\",\"display_name\":\"Gas Heat Airflow Trim\",\"description\":\"Used to make minor changes to nominal gas heat airflow. System temperature rise can be fine tuned with this menu.\",\"value_unit\":\"%\",\"visible\":\"Show\"},{\"Value\":\"87.0\",\"options\":\"81.0[-*-]82.0[-*-]83.0[-*-]84.0[-*-]85.0[-*-]86.0[-*-]87.0[-*-]88.0[-*-]89.0[-*-]90.0[-*-]91.0[-*-]92.0[-*-]93.0[-*-]94.0[-*-]95.0[-*-]96.0[-*-]97.0[-*-]98.0[-*-]99.0[-*-]100.0\",\"Key\":\"GasHAFMultiplierPercent\",\"display_name\":\"Airflow Percentage for High Stage Gas Heat\",\"description\":\"Percentage of the system's maximum airflow to run during high stage gas heating.\",\"value_unit\":\"%\",\"visible\":\"Show\"},{\"Value\":\"70.0\",\"options\":\"55.0[-*-]56.0[-*-]57.0[-*-]58.0[-*-]59.0[-*-]60.0[-*-]61.0[-*-]62.0[-*-]63.0[-*-]64.0[-*-]65.0[-*-]66.0[-*-]67.0[-*-]68.0[-*-]69.0[-*-]70.0[-*-]71.0[-*-]72.0[-*-]73.0[-*-]74.0[-*-]75.0[-*-]76.0[-*-]77.0[-*-]78.0[-*-]79.0[-*-]80.0[-*-]81.0[-*-]82.0[-*-]83.0[-*-]84.0[-*-]85.0\",\"Key\":\"GasStage1MultiplierPercent\",\"display_name\":\"Airflow Percentage for Low Stage Gas Heat\",\"description\":\"Percentage of high stage gas heating airflow to run during low stage gas heating.\",\"value_unit\":\"%\",\"visible\":\"Show\"},{\"Value\":\"30\",\"options\":\"5[-*-]10[-*-]15[-*-]20[-*-]25[-*-]30\",\"Key\":\"GasHeatOnDelay\",\"display_name\":\"Gas Heat On Delay\",\"description\":\"Delay between the start of a heat call and the indoor blower motor starting up.\",\"value_unit\":\"seconds\",\"visible\":\"Show\"},{\"Value\":\"90\",\"options\":\"30[-*-]60[-*-]90[-*-]120[-*-]150[-*-]180\",\"Key\":\"GasHeatOffDelay\",\"display_name\":\"Gas Heat Off Delay\",\"description\":\"Delay between the end of a heat call and the indoor blower motor shutting down.\",\"value_unit\":\"seconds\",\"visible\":\"Show\"},{\"Value\":\"1st Stage\",\"options\":\"1st Stage[-*-]2nd Stage\",\"Key\":\"DefrostGasHeatStage\",\"display_name\":\"Gas Heat Stage During Defrost\",\"description\":\"This setting determines what heat stage will be activated when the furnace receives a defrost call.\",\"value_unit\":\"\",\"visible\":\"Show\"},{\"Value\":\"High\",\"options\":\"Low[-*-]High\",\"Key\":\"DeHumLogic\",\"display_name\":\"Dehumidification Logic\",\"description\":\"Select High to enable dehumidification when the thermostat DH terminal is energized. Select Low to enable dehumidification when the thermostat DH terminal is de-energized.\",\"value_unit\":\"\",\"visible\":\"Show\"},{\"Value\":\"Enabled\",\"options\":\"Disabled[-*-]Enabled\",\"Key\":\"AuxSwitchEnable\",\"display_name\":\"Auxiliary (Condensate) Switch Enable\",\"description\":\"Enable or disable the auxiliary input switch. When enabled, the unit will not operate when the auxiliary switch terminal is open. Typically used with a condensate detect switch to disable the unit when there is too much condensate buildup in the drain pan.\",\"value_unit\":\"\",\"visible\":\"Hide\"}]}"},
{"arr": "51,01,03,01,B1,FF,27,00,03,01,01,01,02,2F,00,03,01,00,00,01,20,00,04,00,28,00,3C,05,1E,00,04,00,05,01,06,01#", "data": "{\"screen\":\"Setting\",\"data\":[{\"Value\":\"Run Time\",\"options\":\"Run Time[-*-]Rate of Change\",\"Key\":\"LegacyThermostatControlAlgorithm\",\"display_name\":\"Control Algorithm\",\"description\":\"Select between Run Time and Rate of Change control algorithm. Run Time will control staging based on previous cycle run time and the selected Setpoint Satisfy Rate. Rate of Change will control staging based on return air temperature trends and the selected Target Cooling/Heating Rate.\",\"value_unit\":\"\",\"visible\":\"Show\"},{\"Value\":\"Disabled\",\"options\":\"Disabled[-*-]Enabled\",\"Key\":\"EnableBIZ\",\"display_name\":\"Supply Air Throttling\",\"description\":\"Enables equipment to throttle cooling/heating operation based on user-settable temperature limits.\",\"value_unit\":\"\",\"visible\":\"Hide\"},{\"Value\":\"40\",\"options\":\"0[-*-]5[-*-]10[-*-]15[-*-]20[-*-]25[-*-]30[-*-]35[-*-]40[-*-]45[-*-]50[-*-]55[-*-]60\",\"Key\":\"CompressorHeatLockout\",\"display_name\":\"Compressor Heat Lockout\",\"description\":\"The compressor will enter a lockout condition and will not run while the outdoor ambient temperature is below the Compressor Heat Lockout temperature. In this case, the system will use only the backup heat source.\",\"value_unit\":\"F\",\"visible\":\"Show\"},{\"Value\":\"30 minutes\",\"options\":\"10 minutes[-*-]15 minutes[-*-]20 minutes[-*-]25 minutes[-*-]30 minutes[-*-]Use Custom Settings\",\"Key\":\"ComfortSetting\",\"display_name\":\"Setpoint Satisfy Rate\",\"description\":\"This time is used by the internal algorithm for controlling system staging. The system will attempt to satisfy the thermostat as close to the selected time as possible. Adjustments will occur for each heating / cooling cycle to meet this time. Selecting Custom Settings will allow you to set a custom profile.\",\"value_unit\":\"\",\"visible\":\"Show\"}]}"},
{"arr": "52,01,03,01,B0,FF,01,00,13,00,02,00,52,03,00,09,04,00,02,06,00,0C,00,07,00,09,00,08,00,0F,09,00,47,4D,56,43,39,36,31,32,30,35,44,4E,42,42,00,0A,00,0B,0B,00,30,30,30,30,30,30,31,30,30,30,00,0C,00,FE,0E,00,02,10,00,02,12,00,02,13,00,03,14,00,78,15,00,01,16,00,0C,17,00,02,18,00,00,19,00,08,1A,00,70,1B,00,98,08#", "data": "{\"screen\":\"Configuration\",\"data\":[{\"Key\":\"ControlID\",\"Value\":19,\"display_name\":\"Controls ID (hidden)\",\"description\":\"Unique identifier for control board, used to determine if this board has any firmware updates available.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"UnitType\",\"Value\":\"Furnace\",\"display_name\":\"HVAC Device\",\"description\":\"The type of HVAC Device you are viewing. Sometimes a single unit can have multiple HVAC functions but each of these functions will appear as a separate HVAC device.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"ControlSoftwareVersion\",\"Value\":9,\"display_name\":\"Firmware Version\",\"description\":\"Specific number associated with the control software. This value is used to determine if any software updates are required.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"SharedDataVersion\",\"Value\":2,\"display_name\":\"Shared Data Version\",\"description\":\"Version number for the shared data programmed onto this board.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"OEMID\",\"Value\":12,\"display_name\":\"OEMID (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"ManufacturerID\",\"Value\":9,\"display_name\":\"Manufacturer ID (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"No.OfModelNo.\",\"Value\":15,\"display_name\":null,\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"ModelNo.Character1~15\",\"Value\":\"GMVC961205DNBB\",\"display_name\":\"Model Number\",\"description\":\"This is the Model Number that is programmed onto the control board. This number should match the model number found on the serial plate. If these two numbers do not match, a Shared Data update may be necessary.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"No.OfSerialNo.\",\"Value\":11,\"display_name\":null,\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"SerialNo.Character1~15\",\"Value\":\"0000001000\",\"display_name\":\"Serial Number (hidden)\",\"description\":\"The Serial Number given to this unit by Goodman/Amana and is listed on the serial plate. This is the Serial Number that is programmed onto the control board. This number should match the serial number found on the serial plate. If these two numbers do not match, a Shared Data update may be necessary. The last four digits of this serial number appear in the Bluetooth network name shown on the phone app.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"NoofIndoorBlowerSpeeds-Stages\",\"Value\":254,\"display_name\":\"Blower Speed Options (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"NoofInducerStages-Stages\",\"Value\":2,\"display_name\":\"Inducer Stages (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"NoofGasHeatStages-Stages\",\"Value\":2,\"display_name\":\"Gas Heat Stage Options (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"NoofPressureSwitches\",\"Value\":2,\"display_name\":\"Pressure Switch Count (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"NoofLimitSwitches\",\"Value\":3,\"display_name\":\"Limit Switch Count (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"FurnaceSize\",\"Value\":120,\"display_name\":\"Furnace Max Capacity\",\"description\":\"Heating capacity of the furnace in KBTUs.\",\"value_unit\":\"KBTU\",\"visible\":\"Show\"},{\"Key\":\"BlowerManufacturerID\",\"Value\":1,\"display_name\":\"Blower Manufacturer ID (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"BlowerMotorSizeHP\",\"Value\":\"1 HP\",\"display_name\":\"Blower Motor Horsepower\",\"description\":\"Horsepower of the blower motor inside the furnace.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"IndoorBlowerRunMode\",\"Value\":\"Airflow\",\"display_name\":\"Indoor Blower Run Mode (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"IndoorBlowerRunDirection\",\"Value\":\"Clockwise\",\"display_name\":\"Indoor Blower Run Direction (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"BlowerMotorCutbackSlope\",\"Value\":8,\"display_name\":\"Blower Motor Cutback Slope (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"BlowerMotorCutbackSpeed\",\"Value\":112,\"display_name\":\"Blower Motor Cutback Speed (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"IndoorBlowerNominal/MaxAirflow\",\"Value\":2200,\"display_name\":\"Max Airflow\",\"description\":\"Maximum airflow that can be provided by the furnace.\",\"value_unit\":\"CFM\",\"visible\":\"Show\"}]}"},
{"arr": "54,01,03,01,B1,FF,03,00,0C,01,C8,B4,B8,BC,C0,C4,C8,CC,D0,D4,D8,DC,06,00,05,01,44,41,42,43,44,07,00,05,01,05,05,0A,14,1E,08,00,05,01,1E,1E,3C,5A,78,0B,00,03,01,00,00,01,12,00,03,01,00,00,01#", "data": "{\"screen\":\"Setting\",\"data\":[{\"Value\":\"0%\",\"options\":\"-10%[-*-]-8%[-*-]-6%[-*-]-4%[-*-]-2%[-*-]0%[-*-]2%[-*-]4%[-*-]6%[-*-]8%[-*-]10%\",\"Key\":\"CoolTrimFactor-High\",\"display_name\":\"Cooling Trim Factor (High)\",\"description\":\"Select airflow trim when inverter system is running high compressor speeds during a cooling cycle. For two stage units, this is the only available trim setting.\",\"value_unit\":\"\",\"visible\":\"Show\"},{\"Value\":\"D\",\"options\":\"A[-*-]B[-*-]C[-*-]D\",\"Key\":\"CoolAirflowProfiles\",\"display_name\":\"Cooling Airflow Profile\",\"description\":\"If it is desirable to quickly ramp up the indoor airflow select profile A. If it is desirable to reach nominal airflow quickly, but a slower ramp up time is required, select profile B. If dehumidification is required immediately when cooling mode begins select profile C. If a slower airflow ramp up / ramp down time is required in addition to dehumidification select profile D or E\",\"value_unit\":\"\",\"visible\":\"Show\"},{\"Value\":\"5\",\"options\":\"5[-*-]10[-*-]20[-*-]30\",\"Key\":\"CoolBlowerOnDelay\",\"display_name\":\"Blower On Delay - Cooling\",\"description\":\"Delay between compressor turning on and indoor blower turning on during a cooling cycle.\",\"value_unit\":\"seconds\",\"visible\":\"Show\"},{\"Value\":\"30\",\"options\":\"30[-*-]60[-*-]90[-*-]120\",\"Key\":\"CoolBlowerOffDelay\",\"display_name\":\"Blower Off Delay - Cooling\",\"description\":\"Delay between the compressor shutting off and the indoor blower shutting off after a cooling cycle.\",\"value_unit\":\"seconds\",\"visible\":\"Show\"},{\"Value\":\"Off\",\"options\":\"Off[-*-]On\",\"Key\":\"DehumidificationEnable\",\"display_name\":\"Dehumidification Enable\",\"description\":\"Internal enable/disable of the dehumidification feature. For equipment which presents A, B, and C as dehumidification options: Setting A allows for the same compressor operation range as standard dehumidification with lower CFM than standard dehumidification; setting B limits the compressor operation range and keeps high dehumidification capacity; setting C will run the system at a fixed 100% compressor speed and airflow. Refer to the IO for further details and figures.\",\"value_unit\":\"\",\"visible\":\"Show\"},{\"Value\":\"No\",\"options\":\"No[-*-]Yes\",\"Key\":\"ClearHistoryFault\",\"display_name\":\"Reset Fault History\",\"description\":\"Selecting yes will clear the fault history of this device.\",\"value_unit\":\"\",\"visible\":\"Show\"}]}"},
{"arr": "54,01,03,01,B0,FF,01,00,04,00,02,00,54,03,00,0D,04,00,FF,05,00,00,07,00,0C,00,08,00,09,00,09,00,0D,0A,00,44,58,31,38,54,43,30,36,30,31,41,44,00,0B,00,0B,0C,00,31,32,33,34,35,36,37,38,39,30,00,0E,00,02,0F,00,FF,10,00,FF,11,00,FF,12,00,02,13,00,FF,14,00,FF,15,00,FF,16,00,FF,17,00,FF,18,00,FF,19,00,FF,1D,00,98,08,1E,00,D6,06,1F,00,FF,FF#", "data": "{\"screen\":\"Configuration\",\"data\":[{\"Key\":\"ControlID\",\"Value\":4,\"display_name\":\"Controls ID (hidden)\",\"description\":\"Unique identifier for control board that is used to determine if this board has any firmware updates available.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"UnitType\",\"Value\":\"AC\",\"display_name\":\"HVAC Device\",\"description\":\"The type of HVAC Device you are viewing.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"ControlSoftwareVersion\",\"Value\":13,\"display_name\":\"Firmware Version\",\"description\":\"Specific number associated with the control software. This number is used to determine if updates are required.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"InverterSoftwareVersion\",\"Value\":\"-\",\"display_name\":\"Inverter Firmware Version (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"SharedDataVersion\",\"Value\":0,\"display_name\":\"Shared Data Version (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"OEMID\",\"Value\":12,\"display_name\":\"OEMID (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"ManufacturerID\",\"Value\":9,\"display_name\":\"Manufacturer ID (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"No.OfModelNo.\",\"Value\":13,\"display_name\":null,\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"ModelNo.Character1~15\",\"Value\":\"DX18TC0601AD\",\"display_name\":\"Model Number\",\"description\":\"This is the Model Number that is programmed onto the control board. This number should match the model number found on the serial plate. If these two numbers do not match, a Shared Data update may be necessary.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"No.OfSerialNo.\",\"Value\":11,\"display_name\":null,\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"SerialNo.Character1~15\",\"Value\":\"1234567890\",\"display_name\":\"Serial Number\",\"description\":\"The Serial Number given to this unit by Goodman/Amana and is listed on the serial plate. This is the Serial Number that is programmed onto the control board. This number should match the serial number found on the serial plate. If these two numbers do not match, a Shared Data update may be necessary. The last four digits of this serial number appear in the Bluetooth network name shown on the phone app.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"NoofODBlowerSpeeds-Stages\",\"Value\":2,\"display_name\":\"Number of Outdoor Blower Stages (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"NoofODBlowerSpeeds-Modulating\",\"Value\":\"Not Available\",\"display_name\":\"Outdoor Blower Type (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"NoofHeatStages-Stages\",\"Value\":\"-\",\"display_name\":\"Number of Heating Stages (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"NoofHeatStages-Modulating\",\"Value\":\"Not Available\",\"display_name\":\"Heat Stage Type (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"NoofCoolStages-Stages\",\"Value\":2,\"display_name\":\"Number of Cooling Stages (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"NoofCoolStages-Modulating\",\"Value\":\"Not Available\",\"display_name\":\"Cool Stage Type (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"NoofLowPressureSwitches\",\"Value\":\"-\",\"display_name\":\"Number of Low Pressure Switches (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"NoofHighPressureSwitches\",\"Value\":\"-\",\"display_name\":\"Number of High Pressure Switches (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"NoofTemperatureSensors\",\"Value\":\"-\",\"display_name\":\"Number of Temperature Sensors (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"NoofPressureSensors\",\"Value\":\"-\",\"display_name\":\"Number of Pressure Sensors (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"ODBlowerManufacturerID\",\"Value\":\"-\",\"display_name\":\"Outdoor Blower Manufacturer ID (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"ODBlowerMotorSizeHP\",\"Value\":\"Not Available\",\"display_name\":\"Outdoor Blower Motor Size (hidden)\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"MaxIndoorAirflow\",\"Value\":2200,\"display_name\":\"Max Airflow from Indoor (hidden)\",\"description\":\"Maximum airflow that can be produced by the indoor unit.\",\"value_unit\":\"CFM\",\"visible\":\"Show\"},{\"Key\":\"ODBlowerNominalCoolingAirflow\",\"Value\":1750,\"display_name\":\"Outdoor Blower Cooling Airflow (hidden)\",\"description\":null,\"value_unit\":\"CFM\",\"visible\":\"Show\"},{\"Key\":\"ODBlowerNominalHeatingAirflow\",\"Value\":\"-\",\"display_name\":\"Outdoor Blower Heating Airflow (hidden)\",\"description\":null,\"value_unit\":\"CFM\",\"visible\":\"Hide\"}]}"},
{"arr": "54,01,03,01,B3,FF,01,00,01,02,00,01,05,00,FF,06,00,FF,07,00,FF,08,00,FF,09,00,FF,0A,00,FF,0B,00,FF,0D,00,00,0E,00,00,0F,00,00,10,00,FF,11,00,00,12,00,FF,13,00,FF,14,00,FF,15,00,FF,16,00,00,18,00,FF,19,00,FF,1A,00,FF,1B,00,FF,1C,00,FF,1D,00,FF,1E,00,FF,1F,00,FF,20,00,FF,21,00,FF,22,00,FF,23,00,FF,24,00,FF,25,00,FF,26,00,FF,29,00,FF,2A,00,FF,2B,00,FF,2C,00,FF,2D,00,FF,2E,00,FF,30,00,FF,31,00,FF,FF,32,00,00,33,00,00,34,00,FF,39,00,00,3A,00,00,3B,00,FF,FF,3C,00,FF,FF,3D,00,FF,3E,00,00,00,3F,00,FF,FF,41,00,FF,42,00,FF,FF#", "data": "{\"screen\":\"Status\",\"data\":[{\"Key\":\"HVACOperation\",\"Value\":\"Communicating\",\"display_name\":\"Outdoor Communication Ability\",\"description\":\"Defines whether the installed outdoor unit uses legacy inputs or is communicating\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"OperatingHeat/CoolMode\",\"Value\":\"Idle/Off\",\"display_name\":\"HVAC Operating Mode\",\"description\":\"Current operating mode of the air conditioner.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"W1SignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - W Terminal\",\"description\":\"Input used for first stage heating call.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"Y1SignalInput\",\"Value\":\"Not Available\",\"display_name\":\"Compressor Call\",\"description\":\"Status of the Y terminal. This is measured at the indoor unit's legacy input terminal block and is used by the thermostat to send a call for the outdoor compressor to turn on.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"Y2SignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - Y2 Terminal\",\"description\":\"Input used for second stage cool call in multi-stage units.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"Y3SignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - Y3 Terminal\",\"description\":\"Input used for high stage cool call in multi-stage units.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"GSignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - G Terminal\",\"description\":\"Current status of the G terminal on this device. The G terminal is used to issue a call for constant fan.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"OSignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - O Terminal\",\"description\":\"O terminal used to send a reverse signal.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"DeHumSignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - Dehum Terminal\",\"description\":\"Dehum terminal used for dehumidification calls.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"FanRequestedRate/Slew\",\"Value\":0,\"display_name\":\"Fan Requested Rate/Slew\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"FanRequestedDelay\",\"Value\":0,\"display_name\":\"Fan Requested Delay\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"FanRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Constant Fan Airflow Request\",\"description\":\"Request for constant fan\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HeatRequestedDemandPercent\",\"Value\":\"-\",\"display_name\":\"Heat Capacity Request\",\"description\":\"The request for heat. This is a value used by the internal algorithm to make sure the appropriate staging will occur. This value does not necessarily correspond to heat capacity. 0% means the system is off. All other values mean the system is running.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"CoolRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Cool Capacity Request\",\"description\":\"The request for cooling. This is a value used by the internal algorithm to make sure the appropriate staging will occur. This value does not necessarily correspond to cooling capacity. 0% means the system is off. All other values mean the system is running.\",\"value_unit\":\"%\",\"visible\":\"Show\"},{\"Key\":\"DefrostRequestedDemandPercent\",\"Value\":\"-\",\"display_name\":\"Heat Capacity Request During Defrost\",\"description\":\"Indoor heat request during defrost operation. This is a value used by the internal algorithm during defrost operation. The outdoor unit will request supplemental heating while a defrost cycle is running. 0% means defrost is not being requested and additional heating is not required. All other values mean defrost is being requested and additional heat is being requested. The internal algorithms will determine what to do with a non zero percentage. This value does not represent overall system capacity. It states that additional capacity is being requested or if it is not being requested.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"EmergencyRequestedDemandPercent\",\"Value\":\"-\",\"display_name\":\"Emergency Heat Request\",\"description\":\"Request for emergency heating (emergency heat is used when the system needs to bypass the primary heat source and run backup heat immediately). This value is for internal use only and indicates if the system is requesting emergency heat or not.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AuxRequestedDemandPercent\",\"Value\":\"-\",\"display_name\":\"Auxiliary Heat Request\",\"description\":\"Request for auxiliary heat.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HumRequestedDemandPercent\",\"Value\":\"-\",\"display_name\":\"Humidify Request\",\"description\":\"Request for humidification.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DehumRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Dehumidification Request\",\"description\":\"Request for dehumidification. This is a value used by the internal algorithm during dehumidification. 0% means dehumidification is not being requested. All other values mean dehumidification is being requested.\",\"value_unit\":\"%\",\"visible\":\"Show\"},{\"Key\":\"ModeCode\",\"Value\":\"Not Available\",\"display_name\":\"Operation Mode\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"RefreshTimer\",\"Value\":\"-\",\"display_name\":\"Refresh Timer\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"HeatCall\",\"Value\":\"-\",\"display_name\":\"Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"CoolCall\",\"Value\":\"-\",\"display_name\":\"Cool Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FanCall\",\"Value\":\"-\",\"display_name\":\"Fan Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"EmergencyHeatCall\",\"Value\":\"-\",\"display_name\":\"Emergency Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AuxHeatCall\",\"Value\":\"-\",\"display_name\":\"Auxiliary Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DefrostCall\",\"Value\":\"-\",\"display_name\":\"Defrost Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"SpecialHeatRelay1Call\",\"Value\":\"-\",\"display_name\":\"Special Heat 1 Call\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"SpecialHeatRelay2Call\",\"Value\":\"-\",\"display_name\":\"Special Heat 2 Call\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DeHumCall\",\"Value\":\"-\",\"display_name\":\"Dehumidification Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HumCall\",\"Value\":\"-\",\"display_name\":\"Humidification Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"VentCall\",\"Value\":\"-\",\"display_name\":\"Ventilation Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AccRelay1Call\",\"Value\":\"-\",\"display_name\":\"Accessory Relay 1 Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AccRelay2Call\",\"Value\":\"-\",\"display_name\":\"Accessory Relay 2 Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"LowPressureSwitch#1\",\"Value\":\"Not Available\",\"display_name\":\"Low Pressure Switch #1\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"LowPressureSwitch#2\",\"Value\":\"Not Available\",\"display_name\":\"Low Pressure Switch #2\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"LowPressureSwitch#3\",\"Value\":\"Not Available\",\"display_name\":\"Low Pressure Switch #3\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"HighPressureSwitch#1\",\"Value\":\"Not Available\",\"display_name\":\"High Pressure Switch #1\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"HighPressureSwitch#2\",\"Value\":\"Not Available\",\"display_name\":\"High Pressure Switch #2\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"HighPressureSwitch#3\",\"Value\":\"Not Available\",\"display_name\":\"High Pressure Switch #3\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"VariableCompressorCapPercentage\",\"Value\":\"-\",\"display_name\":\"Compressor Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"CompressorRPS\",\"Value\":\"-\",\"display_name\":\"Compressor RPS\",\"description\":\"Current speed of the compressor motor in rotations per second.\",\"value_unit\":\"RPS\",\"visible\":\"Hide\"},{\"Key\":\"CompressorRelay1(Y1)\",\"Value\":\"Off\",\"display_name\":\"Compressor Y1 Relay\",\"description\":\"For Non-Communicating equipment only. Status of 24VAC signal to the outdoor unit. Stage 1 cooling call.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"CompressorRelay2(Y2)\",\"Value\":\"Off\",\"display_name\":\"Compressor Y2 Relay\",\"description\":\"For Non-Communicating equipment only. Status of 24VAC signal to the outdoor unit. Stage 2 cooling call.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"ORelay\",\"Value\":\"Not Available\",\"display_name\":\"Reversing Valve\",\"description\":\"For Non-Communicating equipment only. Status of 24VAC signal to the outdoor unit. Reversing valve signal.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"OutdoorFanStage1\",\"Value\":\"Off\",\"display_name\":\"Outdoor Fan Stage 1 Relay\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"OutdoorFanStage2\",\"Value\":\"Off\",\"display_name\":\"Outdoor Fan Stage 2 Relay\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"OutdoorFanRPM\",\"Value\":\"-\",\"display_name\":\"Outdoor Fan Speed\",\"description\":\"Current speed of the outdoor fan in rotations per minute.\",\"value_unit\":\"RPM\",\"visible\":\"Hide\"},{\"Key\":\"OutdoorFanAirflow\",\"Value\":\"-\",\"display_name\":\"Outdoor Fan Airflow\",\"description\":null,\"value_unit\":\"CFM\",\"visible\":\"Hide\"},{\"Key\":\"CrankcaseHeaterRelay\",\"Value\":\"Not Available\",\"display_name\":\"Crankcase Heater Relay\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"RequestedIndoorCFM\",\"Value\":0,\"display_name\":\"Requested Airflow\",\"description\":\"The airflow (in cubic feet per minute) the outdoor unit has determined is necessary for operation. This is the airflow the indoor unit will try to deliver while the unit is active.\",\"value_unit\":\"CFM\",\"visible\":\"Show\"},{\"Key\":\"ReportedIndoorCFM\",\"Value\":\"-\",\"display_name\":\"Reported Airflow\",\"description\":\"Indoor airflow (in cubic feet per minute) as reported by the indoor unit.\",\"value_unit\":\"CFM\",\"visible\":\"Hide\"},{\"Key\":\"BoostModeStatus\",\"Value\":\"Not Available\",\"display_name\":\"Boost Mode\",\"description\":\"If this feature is available and enabled, an inverter can ramp the compressor above default speeds to increase capacity. This shows if the feature is active or inactive. To check if this function is enabled, find the Boost Mode Enable item in the settings for this unit.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"DefrostRunningTime\",\"Value\":\"-\",\"display_name\":\"Defrost Run Time\",\"description\":\"Current run time for defrost cycle.\",\"value_unit\":\"seconds\",\"visible\":\"Hide\"}]}"},
{"arr": "51,01,03,01,B3,FF,01,00,01,02,00,01,03,00,01,04,00,00,06,00,00,07,00,FF,08,00,FF,09,00,00,0A,00,FF,0B,00,FF,0C,00,00,0D,00,FF,0F,00,00,0E,00,FF,10,00,FF,12,00,00,13,00,FF,14,00,00,15,00,00,16,00,00,17,00,00,18,00,00,19,00,00,1A,00,00,1B,00,00,1D,00,00,1E,00,00,1F,00,00,20,00,00,21,00,00,22,00,00,23,00,00,24,00,00,25,00,00,26,00,00,27,00,00,28,00,00,29,00,00,2A,00,00,2B,00,00,2D,00,00,2E,00,00,00,2F,00,00,00,30,00,00,00,31,00,00,00,32,00,00,00,33,00,00,00,34,00,00,35,00,00,36,00,00,37,00,00,00,38,00,00,39,00,00,00,3A,00,00,3B,00,00,3C,00,00,3E,00,00,00,00,00,3F,00,00,00,40,00,00,00,41,00,00,00,42,00,00,00,43,00,00,00,44,00,00,00,45,00,00,00#", "data": "{\"screen\":\"Status\",\"data\":[{\"Key\":\"HVACOperation\",\"Value\":\"Legacy Thermostat\",\"display_name\":\"Thermostat Type\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"OperatingHeat/CoolMode\",\"Value\":\"Idle/Off\",\"display_name\":\"HVAC Operation Mode\",\"description\":\"Current operating mode of the advanced settings. Displays what calls are being made for heating or cooling functions.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"OperatingHum/DeHum/VentMode\",\"Value\":\"Idle/Off\",\"display_name\":\"Hum/Dehum/Vent Mode\",\"description\":\"Displays what calls are being issued by the thermostat for humidification, dehumidification, and/or ventilation.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"SpecialMode\",\"Value\":\"Normal\",\"display_name\":\"Special Mode\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"W1SignalInput\",\"Value\":\"Off\",\"display_name\":\"24V Tstat - W Terminal\",\"description\":\"Shows if the system has an active heating call from the thermostat\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"W2SignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - W2 Terminal\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"W3SignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - W3 Terminal\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"Y1SignalInput\",\"Value\":\"Off\",\"display_name\":\"24V Tstat - Y Terminal\",\"description\":\"Shows if the system has an active cooling call from the thermostat\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"Y2SignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - Y2/DH Terminal\",\"description\":\"Shows if the system has an active 24VAC thermostat signal on the DH/Y2 terminal. This indicates high stage compressor control if outdoor unit is a two stage non-communicating system or a dehumidification call if the outdoor unit is a single stage non-communicating system.\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"Y3SignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - Y3 Terminal\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"GSignalInput\",\"Value\":\"Off\",\"display_name\":\"24V Tstat - G Terminal\",\"description\":\"Shows if the system has an active fan only call from the thermostat.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"OSignalInput\",\"Value\":\"Not Available\",\"display_name\":\"24V Tstat - O Terminal\",\"description\":\"shows if the system has an active reversing valve call from the thermostat (for heat pump control).\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"DeHumSignalInput\",\"Value\":\"Off\",\"display_name\":\"24V Tstat - DH/Y2 Terminal\",\"description\":\"Shows if the system has an active 24VAC thermostat signal on the DH/Y2 terminal. This indicates high stage compressor control if outdoor unit is a two stage non-communicating system or a dehumidification call if the outdoor unit is a single stage non-communicating system.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"HumSignalInput\",\"Value\":\"Not Available\",\"display_name\":\"Humidification Signal\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"VentSignalInput\",\"Value\":\"Not Available\",\"display_name\":\"Ventilation Call Signal\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"FanRequestedRate/Slew\",\"Value\":0,\"display_name\":\"Fan Requested Rate/Slew\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"FanRequestedDelay\",\"Value\":\"-\",\"display_name\":\"Fan Requested Delay\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"FanRequestedDemand\",\"Value\":\"0.0\",\"display_name\":\"Constant Fan Airflow Request\",\"description\":\"This value is for internal algorithm use. During operation, the indoor unit's control algorithm will request a certain amount of fan only airflow. This value represents how much airflow being requested as a percentage of the maximum airflow.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HeatRequestedDemand\",\"Value\":\"0.0\",\"display_name\":\"Heat Capacity Request\",\"description\":\"The request for heat. This is a value used by the internal algorithm to make sure the appropriate staging will occur. This value does not necessarily correspond to heat capacity. 0% means the system is off. All other values mean the system is running.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"CoolRequestedDemand\",\"Value\":\"0.0\",\"display_name\":\"Cool Capacity Request\",\"description\":\"The request for cooling. This is a value used by the internal algorithm to make sure the appropriate staging will occur. This value does not necessarily correspond to cooling capacity. 0% means the system is off. All other values mean the system is running.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DefrostRequestedDemand\",\"Value\":\"0.0\",\"display_name\":\"Heat Capacity Request During Defrost\",\"description\":\"Indoor heat request during defrost operation. This is a value used by the internal algorithm during defrost operation. The outdoor unit will request supplemental heating while a defrost cycle is running. 0% means defrost is not being requested and additional heating is not required. All other values mean defrost is being requested and additional heat is being requested. The internal algorithms will determine what to do with a non zero percentage. This value does not represent overall system capacity. It states that additional capacity is being requested or if it is not being requested.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"EmergencyRequestedDemand\",\"Value\":\"0.0\",\"display_name\":\"Emergency Heat Request\",\"description\":\"Request for emergency heating (emergency heat is used when the system needs to bypass the primary heat source and run backup heat immediately). This value is for internal use only and indicates if the system is requesting emergency heat or not.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AuxRequestedDemand\",\"Value\":\"0.0\",\"display_name\":\"Auxiliary Heat Request\",\"description\":\"Request for auxiliary heating (the auxiliary heat command is used to run the backup heat source as supplemental heating when the primary heat source is unable to satisfy the thermostat demand). This value is for internal use only and indicates if the system is requesting auxiliary heat or not.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HumidificationRequestedDemand\",\"Value\":\"0.0\",\"display_name\":\"Humidify Request\",\"description\":\"Request for humidification.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DehumidificationRequestedDemand\",\"Value\":\"0.0\",\"display_name\":\"Dehumidify Request\",\"description\":\"Request for dehumidification. This is a value used by the internal algorithm during dehumidification. 0% means dehumidification is not being requested. All other values mean dehumidification is being requested.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"ModeCode\",\"Value\":\"Normal Thermostat Call\",\"display_name\":\"Operation Mode\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"RefreshTimer\",\"Value\":0,\"display_name\":\"Refresh Timer\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"HeatCall\",\"Value\":\"0.0\",\"display_name\":\"Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"CoolCall\",\"Value\":\"0.0\",\"display_name\":\"Cool Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FanCall\",\"Value\":\"0.0\",\"display_name\":\"Fan Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"EmergencyHeatCall\",\"Value\":\"0.0\",\"display_name\":\"Emergency Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AuxHeatCall\",\"Value\":\"0.0\",\"display_name\":\"Auxiliary Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DefrostCall\",\"Value\":\"0.0\",\"display_name\":\"Defrost Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"SpecialHeatRelay1Call\",\"Value\":\"0.0\",\"display_name\":\"Special Heat 1 Call\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"SpecialHeatRelay2Call\",\"Value\":\"0.0\",\"display_name\":\"Special Heat 2 Call\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DeHumCall\",\"Value\":\"0.0\",\"display_name\":\"Dehumidification Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HumCall\",\"Value\":\"0.0\",\"display_name\":\"Humidification Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"VentCall\",\"Value\":\"0.0\",\"display_name\":\"Ventilation Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AccRelay1Call\",\"Value\":\"0.0\",\"display_name\":\"Accessory Relay 1 Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AccRelay2Call\",\"Value\":\"0.0\",\"display_name\":\"Accessory Relay 2 Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"RequestedHeat/CoolDemand\",\"Value\":0,\"display_name\":\"Requested Heat/Cool Demand\",\"description\":\"Slated for deletion\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"CurrentCycleStage1RunTime\",\"Value\":0,\"display_name\":\"Stage 1 Current Cycle Time\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"CurrentCycleStage2RunTime\",\"Value\":0,\"display_name\":\"Stage 2 Current Cycle Time\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"PreviousCycleStage1RunTime\",\"Value\":0,\"display_name\":\"Previous Cycle Stage 1 Run Time\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"PreviousCycleStage2RunTime\",\"Value\":0,\"display_name\":\"Previous Cycle Stage 2 Run Time\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"NextCalculatedStage1RunTime\",\"Value\":0,\"display_name\":\"Next Calculated Stage 1 Run Time\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"NextCalculatedStage2RunTime\",\"Value\":0,\"display_name\":\"Next Calculated Stage 2 Run Time\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"Current%DemandCalculation\",\"Value\":\"0.0\",\"display_name\":\"Current Calculated Demand\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"Previous%DemandCalculation\",\"Value\":\"0.0\",\"display_name\":\"Previous Calculated Demand\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"NextCalculated%DemandCalculation\",\"Value\":\"0.0\",\"display_name\":\"Next Calculated Demand\",\"description\":\"Used by FUSS algorithm to determine efficient staging (according to comfort setting parameters)\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"TargetSatisfyTime\",\"Value\":0,\"display_name\":\"Target Satisfy Time\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"CurrentStageUpCounter\",\"Value\":0,\"display_name\":\"Stage Up Cycles\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"SystemOffTimer\",\"Value\":0,\"display_name\":\"System Off Timer\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"StageUpTargetCount\",\"Value\":0,\"display_name\":\"Stage Up Target Count\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"CurrentStageDownCounter\",\"Value\":0,\"display_name\":\"Stage Down Cycles\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"StageDownTargetCounter\",\"Value\":0,\"display_name\":\"Stage Down Target Count\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"PowerOnTimeinMinute\",\"Value\":\"-\",\"display_name\":\"Total On Time\",\"description\":null,\"value_unit\":\"minutes\",\"visible\":\"Hide\"},{\"Key\":\"ConstantFanCycle\",\"Value\":0,\"display_name\":\"Number of Constant Fan Cycles\",\"description\":\"Approximate number of times this thermostat has made a constant fan request\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"CoolingCycle\",\"Value\":0,\"display_name\":\"Number of Cooling Cycles\",\"description\":\"Approximate number of times this thermostat has made a cooling request\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"HPHeatingCycle\",\"Value\":0,\"display_name\":\"Number of Heat Pump Heat Cycles\",\"description\":\"Approximate number of times this thermostat has made a heat pump heat request\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"GasHeatCycle\",\"Value\":0,\"display_name\":\"Number of Gas Heat Cycles\",\"description\":\"Approximate number of times this thermostat has made a gas heat request\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"ElectricHeatCycle\",\"Value\":0,\"display_name\":\"Number of Electric Heat Cycles\",\"description\":\"Approximate number of times this thermostat has made an electric heat request\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"SpecialHeatCycle\",\"Value\":0,\"display_name\":\"Number of Special Heat Cycles\",\"description\":\"Approximate number of times this thermostat has made a special heat request\",\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"DefrostCycle\",\"Value\":0,\"display_name\":\"Number of Defrost Cycles\",\"description\":\"Approximate number of times this thermostat has made a defrost call\",\"value_unit\":null,\"visible\":\"Hide\"}]}"},
{"arr": "52,01,03,01,B3,FF,01,00,01,02,00,01,03,00,01,05,00,00,08,00,00,0B,00,00,0D,00,FF,0E,00,00,0F,00,FF,11,00,00,12,00,FF,13,00,00,14,00,00,15,00,00,16,00,00,17,00,00,18,00,00,19,00,00,1A,00,00,1C,00,FF,1D,00,00,1E,00,00,1F,00,00,20,00,00,21,00,00,22,00,00,23,00,00,24,00,00,25,00,00,26,00,00,27,00,00,28,00,00,29,00,00,2A,00,00,2D,00,00,2E,00,00,2F,00,00,30,00,00,31,00,00,32,00,00,33,00,00,34,00,00,36,00,00,37,00,00,38,00,00,3A,00,00,3B,00,00,3C,00,00,3D,00,01,3E,00,00,3F,00,00,40,00,00,41,00,00,44,00,00,45,00,00,48,00,00,49,00,00,4A,00,00,00,4B,00,00,00,4C,00,00,00#", "data": "{\"screen\":\"Status\",\"data\":[{\"Key\":\"HVACOperation\",\"Value\":\"Legacy Thermostat\",\"display_name\":\"Thermostat Type\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"OperatingHeat/CoolMode\",\"Value\":\"Idle/Off\",\"display_name\":\"HVAC Operating Mode\",\"description\":\"Current operating mode of the furnace. Shows how the system is running according to any calls being made by the thermostat or phone app.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"OperatingHum/DeHum/VentMode\",\"Value\":\"Idle/Off\",\"display_name\":\"Accessory Device Operating Mode\",\"description\":\"Current operating mode of an accessory relay board, if one is connected to the system.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"W1SignalInput\",\"Value\":\"Off\",\"display_name\":\"24V Tstat - W Terminal\",\"description\":\"Shows if the system has an active heating call by the thermostat.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"Y1SignalInput\",\"Value\":\"Off\",\"display_name\":\"24V Tstat - Y Terminal\",\"description\":\"Shows if the system has an active cooling call from the thermostat\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"GSignalInput\",\"Value\":\"Off\",\"display_name\":\"24V Tstat - G Terminal\",\"description\":\"Shows if the system has an active fan only call from the thermostat.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"HumSignalInput\",\"Value\":\"Not Available\",\"display_name\":\"Humidification Signal\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"DeHumSignalInput\",\"Value\":\"Off\",\"display_name\":\"24V Tstat - DH/Y2 Terminal\",\"description\":\"Shows if the system has an active 24VAC thermostat signal on the DH/Y2 terminal. If this system is wired as a non-communicating system with a two-stage outdoor unit, this terminal will act as a Y2 terminal and track high-stage compressor calls to the outdoor unit. In all other cases this terminal will act as a DeHum terminal and track calls for dehumidification. Go to the Air Handler Settings menu to choose whether dehumidification should occur when this terminal is On or Off according to the Dehumidification Logic setting.\",\"value_unit\":null,\"visible\":\"Show\"},{\"Key\":\"VentSignalInput\",\"Value\":\"Not Available\",\"display_name\":\"Ventilation Call Signal\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"FanRequestedRate/Slew\",\"Value\":0,\"display_name\":\"Fan Requested Rate/Slew\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"FanRequestedDelay\",\"Value\":\"-\",\"display_name\":\"Fan Requested Delay\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"FanRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Constant Fan Airflow Request\",\"description\":\"This value is for internal algorithm use. During operation, the indoor unit's control algorithm will request a certain amount of fan only airflow. This value represents how much airflow being requested as a percentage of the maximum airflow.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HeatRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Heat Capacity Request\",\"description\":\"The request for heat. This is a value used by the internal algorithm to make sure the appropriate staging will occur. This value does not necessarily correspond to heat capacity. 0% means the system is off. All other values mean the system is running.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"CoolRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Cool Capacity Request\",\"description\":\"The request for cooling. This is a value used by the internal algorithm to make sure the appropriate staging will occur. This value does not necessarily correspond to cooling capacity. 0% means the system is off. All other values mean the system is running.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DefrostRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Heat Capacity Request During Defrost\",\"description\":\"Indoor heat request during defrost operation. This is a value used by the internal algorithm during defrost operation. The outdoor unit will request supplemental heating while a defrost cycle is running. 0% means defrost is not being requested and additional heating is not required. All other values mean defrost is being requested and additional heat is being requested. The internal algorithms will determine what to do with a non zero percentage. This value does not represent overall system capacity. It states that additional capacity is being requested or if it is not being requested.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"EmergencyRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Emergency Heat Request\",\"description\":\"Request for emergency heating (emergency heat is used when the system needs to bypass the primary heat source and run backup heat immediately). This value is for internal use only and indicates if the system is requesting emergency heat or not.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AuxRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Auxiliary Heat Request\",\"description\":\"Request for auxiliary heating (the auxiliary heat command is used to run the backup heat source as supplemental heating when the primary heat source is unable to satisfy the thermostat demand). This value is for internal use only and indicates if the system is requesting auxiliary heat or not.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HumRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Humidify Request\",\"description\":\"Request for humidification.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DehumRequestedDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Dehumidify Request\",\"description\":\"Request for dehumidification. This is a value used by the internal algorithm during dehumidification. 0% means dehumidification is not being requested. All other values mean dehumidification is being requested.\",\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"ModeCode\",\"Value\":\"Not Available\",\"display_name\":\"Operation Mode\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"RefreshTimer\",\"Value\":0,\"display_name\":\"Refresh Timer\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"HeatCall\",\"Value\":\"0.0\",\"display_name\":\"Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"CoolCall\",\"Value\":\"0.0\",\"display_name\":\"Cool Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FanCall\",\"Value\":\"0.0\",\"display_name\":\"Fan Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"EmergencyHeatCall\",\"Value\":\"0.0\",\"display_name\":\"Emergency Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AuxHeatCall\",\"Value\":\"0.0\",\"display_name\":\"Auxiliary Heat Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DefrostCall\",\"Value\":\"0.0\",\"display_name\":\"Defrost Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"SpecialHeatRelay1Call\",\"Value\":\"0.0\",\"display_name\":\"Special Heat 1 Call\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"SpecialHeatRelay2Call\",\"Value\":\"0.0\",\"display_name\":\"Special Heat 2 Call\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"DeHumCall\",\"Value\":\"0.0\",\"display_name\":\"Dehumidification Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"HumCall\",\"Value\":\"0.0\",\"display_name\":\"Humidification Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"VentCall\",\"Value\":\"0.0\",\"display_name\":\"Ventilation Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AccRelay1Call\",\"Value\":\"0.0\",\"display_name\":\"Accessory Relay 1 Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"AccRelay2Call\",\"Value\":\"0.0\",\"display_name\":\"Accessory Relay 2 Call Capacity\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FUSSFanDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Fan Demand Percent\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FUSSCompressorHeatDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Compressor Heat Demand Percent\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FUSSGasHeatDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Gas Heat Demand Percent\",\"description\":\"Gas heating percentage demand that is being requested by the internal control algorithm\",\"value_unit\":\"%\",\"visible\":\"Show\"},{\"Key\":\"FUSSCompressorCoolDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Compressor Cool Demand Percent\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FUSSDefrostDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Defrost Demand Percent\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FUSSHumDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Hum Demand Percent\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FUSSDeHumDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"DeHum Demand Percent\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FUSSVentilatorDemandPercent\",\"Value\":\"0.0\",\"display_name\":\"Ventilator Demand Percent\",\"description\":null,\"value_unit\":\"%\",\"visible\":\"Hide\"},{\"Key\":\"FlameCurrent\",\"Value\":0,\"display_name\":\"Flame Current\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"PressureSwitch#1Input\",\"Value\":\"Open\",\"display_name\":\"Pressure Switch #1\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"PressureSwitch#2Input\",\"Value\":\"Open\",\"display_name\":\"Pressure Switch #2\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"HighLimitSwitchInput\",\"Value\":\"Open\",\"display_name\":\"High Limit Switch\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"RolloutLimitSwitchInput\",\"Value\":\"Open\",\"display_name\":\"Rollout Limit Switch\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"AuxLimitSwitchInput\",\"Value\":\"Open\",\"display_name\":\"Aux Limit Switch Input\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"CondensateSwitchInput\",\"Value\":\"Closed\",\"display_name\":\"Condensate Switch\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"RetryCount\",\"Value\":0,\"display_name\":\"Retry Count\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"RecycleCount\",\"Value\":0,\"display_name\":\"Recycle Count\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"InducerStageRelay1\",\"Value\":\"Off\",\"display_name\":\"Inducer Stage 1 Relay\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"InducerStageRelay2\",\"Value\":\"Off\",\"display_name\":\"Inducer Stage 2 Relay\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"GasValveStageRelay1\",\"Value\":\"Off\",\"display_name\":\"Gas Valve Stage Relay 1\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"GasValveStageRelay2\",\"Value\":\"Off\",\"display_name\":\"Gas Valve Stage Relay 2\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"EACRelay\",\"Value\":\"Off\",\"display_name\":\"EAC Relay\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"IgnitorRelay\",\"Value\":\"Off\",\"display_name\":\"Ignitor Relay\",\"description\":null,\"value_unit\":null,\"visible\":\"Hide\"},{\"Key\":\"IndoorBlowerAirflow\",\"Value\":0,\"display_name\":\"Current Airflow\",\"description\":\"The current airflow being produced by the indoor unit.\",\"value_unit\":\"CFM\",\"visible\":\"Show\"},{\"Key\":\"FanCurrentOnDelayRemainingStatus\",\"Value\":0,\"display_name\":\"Remaining Fan On Delay\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"},{\"Key\":\"FanCurrentOffDelayRemainingStatus\",\"Value\":0,\"display_name\":\"Remaining Fan Off Delay\",\"description\":null,\"value_unit\":\"seconds\",\"visible\":\"Hide\"}]}"}]