Skip to content

Instantly share code, notes, and snippets.

@thxthx0
Created September 20, 2021 21:51
Show Gist options
  • Save thxthx0/12074f1f5249e14b2a0aada75f590c9b to your computer and use it in GitHub Desktop.
Save thxthx0/12074f1f5249e14b2a0aada75f590c9b to your computer and use it in GitHub Desktop.
Tasmota Script Ver. b for QS-WiFi-D01-TRIAC 150W 1CH-Dimmer
>D
sw=0
tmp=0
cnt=0
tmr=0
hold=0
pwrt=0
slid=0
dim=""
doff="FF550005DC0A"
splo=2 ;short press lolimit
spup=10 ;short press uplimit
ddir=0 ;dim dir 0/1
dmul=2.2 ;dim multipl 1..2.55
dstp=2 ;dim step/speed 1..5
dlo=15 ;dim lolimit min.0
dup=95 ;dim uplimit max.100
dval=50 ;start dim level 0..100
>B
print > Wifi-1CH-Dimmer-Script v2.0b <
print >> QS-WiFi-D01 150W Dimmer <<
;hide cnt webui
->WebSensor1 0
;reset cnt@teleperiod
->SetOption79 1
->Baudrate 9600
;boot sequ
=#snddim(dval)
delay(1000)
->SerialSend5 %doff%
=>Power1 0
>F
cnt=pc[1]
if chg[cnt]>0
;sw press
then sw=1
else sw=0
;sw not pressed
endif
; 100ms timer
tmr+=1
; short press
if sw==0
and tmr>splo
and tmr<spup
then
pwrt^=1
;change on/off
if pwrt>0
then
=#snddim(dval)
=>Power1 1
else
->SerialSend5 %doff%
=>Power1 0
endif
endif
; long press
if sw>0
then
if tmr>spup
then
hold=1
;off then on
if pwrt==0
then
pwrt=1
endif
;dim when on&hold
if pwrt>0
then
if ddir>0
then
;incr dimlevel
dval+=dstp
if dval>dup
then
;up limit change dir
delay(700)
ddir^=1
endif
else
;decr dimlevel
dval-=dstp
if dval<dlo
then
;lo limit change dir
delay(700)
ddir^=1
endif
endif
endif
endif
else
tmr=0
if hold>0
then
hold=0
;change dim dir
ddir^=1
endif
endif
if chg[dval]>0
then
=#snddim(dval)
=>Dimmer %dval%
endif
>E
; slider
slid=Dimmer
if chg[slid]>0
then
; dim per slider
if slid>0
then
dval=slid
else
pwrt=0
endif
endif
>P
; on/off webui
if pwr[1]>0
then
pwrt=1
dim="FF55"+hn(dval*dmul)+"05DC0A"
->SerialSend5 %dim%
else
pwrt=0
->SerialSend5 %doff%
endif
; subroutine
#snddim(tmp)
dim="FF55"+hn(tmp*dmul)+"05DC0A"
->SerialSend5 %dim%
#
@thxthx0
Copy link
Author

thxthx0 commented Sep 20, 2021

Hi, Tasmota 9.5.0 ... Script for QS-WiFi-D01-TRIAC 150W 1CH-Dimmer
(changes the dimming direction when min/max brightness is reached and doesn't stop dimming)

Template:
{"NAME":"QS-WiFi-D01 150W Dimmer","GPIO":[0,3200,0,3232,0,0,0,0,0,352,416,0,0,1],"FLAG":0,"BASE":18}

Info:
https://templates.blakadder.com/qs-wifi_D01_dimmer.html

precompiled tasmota-scripting.bin / tasmota-scripting.bin.gz files:
https://github.com/tasmota/install/tree/main/firmware/unofficial

@oberlinatgithub
Copy link

Hi thxThx0!
Thank you for your great job!
I have an QS-WIFI-D02-TRIAC 1 Chanel Dimmer and your script worked with Tasmota 9.2.0.6 good....
With the button it works perfect, but the toggle in Tasmota dont switch on or off.
When i turn the brightness on minimun the light goes off.
I am too stupid do understand the code, hopefully you can help?
Have a nice day

@thxthx0
Copy link
Author

thxthx0 commented Oct 13, 2021

Hi @oberlinatgithub,
I don't know if there are any differences between QS-WIFI-D01 and D02, I only have D01.

brightness on minimum and the light goes off is ok,
but with power toggle or moving the slider it should come on again.

Maybe the whole script was not inserted due to more memory limitations in previous Tasmota versions (?),
would be worth a try with Tasmota 9.5+

@oberlinatgithub
Copy link

Thanks for the fast respond! Unfortunately, I don't know enough about the material and it is also possible that I destroyed something while soldering? I also have 2 MS-105B, which I implemented with local tuya. Maybe I'll try that one day.
Uploading IMG_20211013_195521.jpg…

@mikketeus
Copy link

Hi, I just upgraded to tastmota 10.0.0.3 and it's the same for me.
The dimmer works, but on/off does not?
In the console I get an error: var not found: Dimmer

@thxthx0
Copy link
Author

thxthx0 commented Nov 29, 2021

The dimmer works, but on/off does not?

Hi,

this must be set in my_user_config.h / user_config_override.h:

#define USE_SCRIPT                               // Add support for script (+17k code)
  #define SCRIPT_POWER_SECTION                   // enable >P section (execute on power changes)

or you may use:
https://github.com/tasmota/install/blob/main/firmware/unofficial/tasmota-scripting.bin
or
https://github.com/tasmota/install/blob/main/firmware/unofficial/tasmota-scripting.bin.gz

@mikketeus
Copy link

Nice! I recompiled v10.0.0.3 with #define SCRIPT_POWER_SECTION and that worked like a charm.
Thanks a lot! :)

Michael