Skip to content

Instantly share code, notes, and snippets.

@tijcolem
Created September 15, 2022 21:46
Show Gist options
  • Star 0 You must be signed in to star a gist
  • Fork 0 You must be signed in to fork a gist
  • Save tijcolem/0760249a7909f97f3eb4ca25aa23c99c to your computer and use it in GitHub Desktop.
Save tijcolem/0760249a7909f97f3eb4ca25aa23c99c to your computer and use it in GitHub Desktop.
Office_HVAC Sample Updated
{
"analysis": {
"display_name": "Office_HVAC",
"name": "Office_HVAC",
"output_variables": [],
"problem": {
"workflow": [
{
"name": "aedg_office_hvac_fan_coil_doas",
"display_name": "AedgOfficeHvacFanCoilDoas",
"measure_type": "RubyMeasure",
"measure_definition_class_name": "AedgOfficeHvacFanCoilDoas",
"measure_definition_directory": "./measures/ad5974a4-c190-4399-9b06-4da7e102c080",
"measure_definition_directory_local": "/Users/tcoleman/git/OpenStudio-PAT/sample_projects/Office_HVAC/measures/ad5974a4-c190-4399-9b06-4da7e102c080",
"measure_definition_display_name": "AedgOfficeHvacFanCoilDoas",
"measure_definition_name": "aedg_office_hvac_fan_coil_doas",
"measure_definition_name_xml": null,
"measure_definition_uuid": "298c5638-bd9d-4d6a-9c8a-e0514df4db4a",
"measure_definition_version_uuid": "3850860d-c4b4-4b99-823f-5ec0bbacdd4e",
"uuid": "298c5638-bd9d-4d6a-9c8a-e0514df4db4a",
"version_uuid": "3850860d-c4b4-4b99-823f-5ec0bbacdd4e",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG.",
"taxonomy": "HVAC.Whole System",
"arguments": [
{
"display_name": "This space type should be part of a ceiling return air plenum.",
"display_name_short": "ceilingReturnPlenumSpaceType",
"name": "ceilingReturnPlenumSpaceType",
"value_type": "string",
"default_value": "Office WholeBuilding - Sm Office",
"value": "Office WholeBuilding - Sm Office"
},
{
"display_name": "Total Cost for HVAC System ($).",
"display_name_short": "costTotalHVACSystem",
"name": "costTotalHVACSystem",
"value_type": "double",
"default_value": 0,
"value": 4000
}
],
"variables": [
{
"argument": {
"display_name": "Skip AedgOfficeHvacFanCoilDoas",
"display_name_short": "Skip entire measure",
"name": "__SKIP__",
"value_type": "boolean",
"default_value": false,
"value": false
},
"display_name": "Skip AedgOfficeHvacFanCoilDoas",
"display_name_short": "Skip entire measure",
"variable_type": "variable",
"units": null,
"minimum": false,
"maximum": true,
"relation_to_output": null,
"static_value": false,
"variable": true,
"uncertainty_description": {
"attributes": [
{
"name": "discrete",
"values_and_weights": []
},
{
"name": "lower_bounds",
"value": false
},
{
"name": "upper_bounds",
"value": false
},
{
"name": "modes",
"value": false
},
{
"name": "delta_x",
"value": null
},
{
"name": "stddev",
"value": null
},
{
"name": "discrete",
"values_and_weights": [
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
}
]
}
],
"type": "discrete"
},
"workflow_index": 0
},
{
"argument": {
"display_name": "Apply recommended availability and ventilation schedules for air handlers?",
"display_name_short": "remake_schedules",
"name": "remake_schedules",
"value_type": "boolean",
"default_value": true,
"value": true
},
"display_name": "Apply recommended availability and ventilation schedules for air handlers?",
"display_name_short": "Apply recommended availability and ventilation schedules for air handlers?",
"variable_type": "variable",
"units": "",
"minimum": true,
"maximum": true,
"relation_to_output": null,
"static_value": true,
"uuid": "",
"version_uuid": "",
"variable": true,
"uncertainty_description": {
"type": "discrete",
"attributes": [
{
"name": "discrete",
"values_and_weights": [
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
}
]
},
{
"name": "lower_bounds",
"value": true
},
{
"name": "upper_bounds",
"value": true
},
{
"name": "modes",
"value": 1
},
{
"name": "delta_x",
"value": null
},
{
"name": "stddev",
"value": null
}
]
},
"workflow_index": 1
}
],
"workflow_index": 0
},
{
"name": "aedg_office_hvac_vav_dx",
"display_name": "AedgOfficeHvacVavDx",
"measure_type": "RubyMeasure",
"measure_definition_class_name": "AedgOfficeHvacVavDx",
"measure_definition_directory": "./measures/750e74e3-ebb1-45c9-a463-9563d1137d03",
"measure_definition_directory_local": "/Users/tcoleman/git/OpenStudio-PAT/sample_projects/Office_HVAC/measures/750e74e3-ebb1-45c9-a463-9563d1137d03",
"measure_definition_display_name": "AedgOfficeHvacVavDx",
"measure_definition_name": "aedg_office_hvac_vav_dx",
"measure_definition_name_xml": null,
"measure_definition_uuid": "ffdf05ce-34c2-498e-9ca8-4ef8fe3a9af5",
"measure_definition_version_uuid": "9f791c8c-4419-45b4-8f84-71589a63cfc6",
"uuid": "ffdf05ce-34c2-498e-9ca8-4ef8fe3a9af5",
"version_uuid": "9f791c8c-4419-45b4-8f84-71589a63cfc6",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG.",
"taxonomy": "HVAC.Whole System",
"arguments": [
{
"display_name": "This space type should be part of a ceiling return air plenum.",
"display_name_short": "ceilingReturnPlenumSpaceType",
"name": "ceilingReturnPlenumSpaceType",
"value_type": "string",
"default_value": "Office WholeBuilding - Sm Office",
"value": "Office WholeBuilding - Sm Office"
},
{
"display_name": "Total Cost for HVAC System ($).",
"display_name_short": "costTotalHVACSystem",
"name": "costTotalHVACSystem",
"value_type": "double",
"default_value": 0,
"value": 4000
}
],
"variables": [
{
"argument": {
"display_name": "Skip AedgOfficeHvacVavDx",
"display_name_short": "Skip entire measure",
"name": "__SKIP__",
"value_type": "boolean",
"default_value": false,
"value": false
},
"display_name": "Skip AedgOfficeHvacVavDx",
"display_name_short": "Skip entire measure",
"variable_type": "variable",
"units": null,
"minimum": false,
"maximum": true,
"relation_to_output": null,
"static_value": false,
"variable": true,
"uncertainty_description": {
"attributes": [
{
"name": "discrete",
"values_and_weights": []
},
{
"name": "lower_bounds",
"value": false
},
{
"name": "upper_bounds",
"value": false
},
{
"name": "modes",
"value": false
},
{
"name": "delta_x",
"value": null
},
{
"name": "stddev",
"value": null
},
{
"name": "discrete",
"values_and_weights": [
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
}
]
}
],
"type": "discrete"
},
"workflow_index": 0
},
{
"argument": {
"display_name": "Apply recommended availability and ventilation schedules for air handlers?",
"display_name_short": "remake_schedules",
"name": "remake_schedules",
"value_type": "boolean",
"default_value": true,
"value": true
},
"display_name": "Apply recommended availability and ventilation schedules for air handlers?",
"display_name_short": "Apply recommended availability and ventilation schedules for air handlers?",
"variable_type": "variable",
"units": "",
"minimum": true,
"maximum": true,
"relation_to_output": null,
"static_value": true,
"uuid": "",
"version_uuid": "",
"variable": true,
"uncertainty_description": {
"type": "discrete",
"attributes": [
{
"name": "discrete",
"values_and_weights": [
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
}
]
},
{
"name": "lower_bounds",
"value": true
},
{
"name": "upper_bounds",
"value": true
},
{
"name": "modes",
"value": 1
},
{
"name": "delta_x",
"value": null
},
{
"name": "stddev",
"value": null
}
]
},
"workflow_index": 1
}
],
"workflow_index": 1
},
{
"name": "aedg_office_hvac_radiant_doas",
"display_name": "AedgOfficeHvacRadiantDoas",
"measure_type": "RubyMeasure",
"measure_definition_class_name": "AedgOfficeHvacRadiantDoas",
"measure_definition_directory": "./measures/13d5289f-43f6-4c51-a890-d3542daa7be0",
"measure_definition_directory_local": "/Users/tcoleman/git/OpenStudio-PAT/sample_projects/Office_HVAC/measures/13d5289f-43f6-4c51-a890-d3542daa7be0",
"measure_definition_display_name": "AedgOfficeHvacRadiantDoas",
"measure_definition_name": "aedg_office_hvac_radiant_doas",
"measure_definition_name_xml": null,
"measure_definition_uuid": "3d7edb7b-aeff-4a59-87f2-138766b48c11",
"measure_definition_version_uuid": "5590e265-8ed7-46d6-84af-079f604ee71e",
"uuid": "3d7edb7b-aeff-4a59-87f2-138766b48c11",
"version_uuid": "5590e265-8ed7-46d6-84af-079f604ee71e",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG.",
"taxonomy": "HVAC.Whole System",
"arguments": [
{
"display_name": "This space type should be part of a ceiling return air plenum.",
"display_name_short": "ceilingReturnPlenumSpaceType",
"name": "ceilingReturnPlenumSpaceType",
"value_type": "string",
"default_value": "Office WholeBuilding - Sm Office",
"value": "Office WholeBuilding - Sm Office"
},
{
"display_name": "Total Cost for HVAC System ($).",
"display_name_short": "costTotalHVACSystem",
"name": "costTotalHVACSystem",
"value_type": "double",
"default_value": 0,
"value": 10000
},
{
"display_name": "Apply recommended availability and ventilation schedules for air handlers?",
"display_name_short": "remake_schedules",
"name": "remake_schedules",
"value_type": "boolean",
"default_value": true,
"value": true
}
],
"variables": [
{
"argument": {
"display_name": "Skip AedgOfficeHvacRadiantDoas",
"display_name_short": "Skip entire measure",
"name": "__SKIP__",
"value_type": "boolean",
"default_value": false,
"value": false
},
"display_name": "Skip AedgOfficeHvacRadiantDoas",
"display_name_short": "Skip entire measure",
"variable_type": "variable",
"units": null,
"minimum": false,
"maximum": true,
"relation_to_output": null,
"static_value": false,
"variable": true,
"uncertainty_description": {
"attributes": [
{
"name": "discrete",
"values_and_weights": []
},
{
"name": "lower_bounds",
"value": false
},
{
"name": "upper_bounds",
"value": false
},
{
"name": "modes",
"value": false
},
{
"name": "delta_x",
"value": null
},
{
"name": "stddev",
"value": null
},
{
"name": "discrete",
"values_and_weights": [
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
}
]
}
],
"type": "discrete"
},
"workflow_index": 0
}
],
"workflow_index": 2
},
{
"name": "aedg_office_hvac_vav_ch_w",
"display_name": "AedgOfficeHvacVavChW",
"measure_type": "RubyMeasure",
"measure_definition_class_name": "AedgOfficeHvacVavChW",
"measure_definition_directory": "./measures/54185015-71f9-4397-b3f2-b0f3254fbc54",
"measure_definition_directory_local": "/Users/tcoleman/git/OpenStudio-PAT/sample_projects/Office_HVAC/measures/54185015-71f9-4397-b3f2-b0f3254fbc54",
"measure_definition_display_name": "AedgOfficeHvacVavChW",
"measure_definition_name": "aedg_office_hvac_vav_ch_w",
"measure_definition_name_xml": null,
"measure_definition_uuid": "28e4e4fb-a10a-4f85-82f9-c4ad2dd3cf12",
"measure_definition_version_uuid": "d96bbbef-c5ad-49f5-9825-2e8c998a5def",
"uuid": "28e4e4fb-a10a-4f85-82f9-c4ad2dd3cf12",
"version_uuid": "d96bbbef-c5ad-49f5-9825-2e8c998a5def",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG.",
"taxonomy": "HVAC.Whole System",
"arguments": [
{
"display_name": "This space type should be part of a ceiling return air plenum.",
"display_name_short": "ceilingReturnPlenumSpaceType",
"name": "ceilingReturnPlenumSpaceType",
"value_type": "string",
"default_value": "Office WholeBuilding - Sm Office",
"value": "Office WholeBuilding - Sm Office"
},
{
"display_name": "Total Cost for HVAC System ($).",
"display_name_short": "costTotalHVACSystem",
"name": "costTotalHVACSystem",
"value_type": "double",
"default_value": 0,
"value": 3500
},
{
"display_name": "Apply recommended availability and ventilation schedules for air handlers?",
"display_name_short": "remake_schedules",
"name": "remake_schedules",
"value_type": "boolean",
"default_value": true,
"value": true
}
],
"variables": [
{
"argument": {
"display_name": "Skip AedgOfficeHvacVavChW",
"display_name_short": "Skip entire measure",
"name": "__SKIP__",
"value_type": "boolean",
"default_value": false,
"value": false
},
"display_name": "Skip AedgOfficeHvacVavChW",
"display_name_short": "Skip entire measure",
"variable_type": "variable",
"units": null,
"minimum": false,
"maximum": true,
"relation_to_output": null,
"static_value": false,
"variable": true,
"uncertainty_description": {
"attributes": [
{
"name": "discrete",
"values_and_weights": []
},
{
"name": "lower_bounds",
"value": false
},
{
"name": "upper_bounds",
"value": false
},
{
"name": "modes",
"value": false
},
{
"name": "delta_x",
"value": null
},
{
"name": "stddev",
"value": null
},
{
"name": "discrete",
"values_and_weights": [
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
}
]
}
],
"type": "discrete"
},
"workflow_index": 0
}
],
"workflow_index": 3
},
{
"name": "xcel_eda_tariff_selectionand_model_setup",
"display_name": "XcelEDATariffSelectionandModelSetup",
"measure_type": "EnergyPlusMeasure",
"measure_definition_class_name": "XcelEDATariffSelectionandModelSetup",
"measure_definition_directory": "./measures/3ccda33f-1aea-4d7e-a6dc-5113b7ce6719",
"measure_definition_directory_local": "/Users/tcoleman/git/OpenStudio-PAT/sample_projects/Office_HVAC/measures/3ccda33f-1aea-4d7e-a6dc-5113b7ce6719",
"measure_definition_display_name": "XcelEDATariffSelectionandModelSetup",
"measure_definition_name": "xcel_eda_tariff_selectionand_model_setup",
"measure_definition_name_xml": null,
"measure_definition_uuid": "c5ab60e9-b8e5-4653-a502-5ed030f1335d",
"measure_definition_version_uuid": "0233e26b-9ce6-45c9-8f2b-86d30472bb66",
"uuid": "c5ab60e9-b8e5-4653-a502-5ed030f1335d",
"version_uuid": "0233e26b-9ce6-45c9-8f2b-86d30472bb66",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program.",
"taxonomy": "Economics.Life Cycle Cost Analysis",
"arguments": [
{
"display_name": "Select an Electricity Tariff.",
"display_name_short": "elec_tar",
"name": "elec_tar",
"value_type": "string",
"default_value": "Secondary General",
"value": "Commercial"
},
{
"display_name": "Select a Gas Tariff.",
"display_name_short": "gas_tar",
"name": "gas_tar",
"value_type": "string",
"default_value": "Large CG",
"value": "Small CG"
}
],
"variables": [
{
"argument": {
"display_name": "Skip XcelEDATariffSelectionandModelSetup",
"display_name_short": "Skip entire measure",
"name": "__SKIP__",
"value_type": "boolean",
"default_value": false,
"value": false
},
"display_name": "Skip XcelEDATariffSelectionandModelSetup",
"display_name_short": "Skip entire measure",
"variable_type": "variable",
"units": null,
"minimum": false,
"maximum": true,
"relation_to_output": null,
"static_value": false,
"variable": true,
"uncertainty_description": {
"attributes": [
{
"name": "discrete",
"values_and_weights": []
},
{
"name": "lower_bounds",
"value": false
},
{
"name": "upper_bounds",
"value": false
},
{
"name": "modes",
"value": false
},
{
"name": "delta_x",
"value": null
},
{
"name": "stddev",
"value": null
},
{
"name": "discrete",
"values_and_weights": [
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
}
]
}
],
"type": "discrete"
},
"workflow_index": 0
}
],
"workflow_index": 4
},
{
"name": "openstudio_results",
"display_name": "OpenStudio Results",
"measure_type": "ReportingMeasure",
"measure_definition_class_name": "OpenStudioResults",
"measure_definition_directory": "./measures/f8e23017-894d-4bdf-977f-37e3961e6f42",
"measure_definition_directory_local": "/Users/tcoleman/git/OpenStudio-PAT/sample_projects/Office_HVAC/measures/f8e23017-894d-4bdf-977f-37e3961e6f42",
"measure_definition_display_name": "OpenStudio Results",
"measure_definition_name": "openstudio_results",
"measure_definition_name_xml": null,
"measure_definition_uuid": "a25386cd-60e4-46bc-8b11-c755f379d916",
"measure_definition_version_uuid": "96d48c9c-dd58-4ace-b2b0-0a2b36fd603d",
"uuid": "a25386cd-60e4-46bc-8b11-c755f379d916",
"version_uuid": "96d48c9c-dd58-4ace-b2b0-0a2b36fd603d",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data.",
"taxonomy": "Reporting.QAQC",
"arguments": [
{
"display_name": "Model Summary",
"display_name_short": "building_summary_section",
"name": "building_summary_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Annual Overview",
"display_name_short": "annual_overview_section",
"name": "annual_overview_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Monthly Overview",
"display_name_short": "monthly_overview_section",
"name": "monthly_overview_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Utility Bills/Rates",
"display_name_short": "utility_bills_rates_section",
"name": "utility_bills_rates_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Envelope",
"display_name_short": "envelope_section_section",
"name": "envelope_section_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Space Type Breakdown",
"display_name_short": "space_type_breakdown_section",
"name": "space_type_breakdown_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Space Type Summary",
"display_name_short": "space_type_details_section",
"name": "space_type_details_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Interior Lighting Summary",
"display_name_short": "interior_lighting_section",
"name": "interior_lighting_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Plug Loads Summary",
"display_name_short": "plug_loads_section",
"name": "plug_loads_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Exterior Lighting",
"display_name_short": "exterior_light_section",
"name": "exterior_light_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Water Use Equipment",
"display_name_short": "water_use_section",
"name": "water_use_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "HVAC Load Profiles",
"display_name_short": "hvac_load_profile",
"name": "hvac_load_profile",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Zone Conditions",
"display_name_short": "zone_condition_section",
"name": "zone_condition_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Zone Overview",
"display_name_short": "zone_summary_section",
"name": "zone_summary_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Zone Equipment Detail",
"display_name_short": "zone_equipment_detail_section",
"name": "zone_equipment_detail_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Air Loops Detail",
"display_name_short": "air_loops_detail_section",
"name": "air_loops_detail_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Plant Loops Detail",
"display_name_short": "plant_loops_detail_section",
"name": "plant_loops_detail_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Outdoor Air",
"display_name_short": "outdoor_air_section",
"name": "outdoor_air_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Cash Flow",
"display_name_short": "cost_summary_section",
"name": "cost_summary_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Site and Source Summary",
"display_name_short": "source_energy_section",
"name": "source_energy_section",
"value_type": "boolean",
"default_value": true,
"value": true
},
{
"display_name": "Schedule Overview",
"display_name_short": "schedules_overview_section",
"name": "schedules_overview_section",
"value_type": "boolean",
"default_value": true,
"value": true
}
],
"variables": [
{
"argument": {
"display_name": "Skip OpenStudio Results",
"display_name_short": "Skip entire measure",
"name": "__SKIP__",
"value_type": "boolean",
"default_value": false,
"value": false
},
"display_name": "Skip OpenStudio Results",
"display_name_short": "Skip entire measure",
"variable_type": "variable",
"units": null,
"minimum": false,
"maximum": true,
"relation_to_output": null,
"static_value": false,
"variable": true,
"uncertainty_description": {
"attributes": [
{
"name": "discrete",
"values_and_weights": []
},
{
"name": "lower_bounds",
"value": false
},
{
"name": "upper_bounds",
"value": false
},
{
"name": "modes",
"value": false
},
{
"name": "delta_x",
"value": null
},
{
"name": "stddev",
"value": null
},
{
"name": "discrete",
"values_and_weights": [
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": false,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
},
{
"value": true,
"weight": 0.03571428571428571
}
]
}
],
"type": "discrete"
},
"workflow_index": 0
}
],
"workflow_index": 5
}
],
"algorithm": {
"objective_functions": []
},
"analysis_type": null,
"design_alternatives": [
{
"name": "Baseline",
"seed": {
"file_type": "OSM",
"path": "./seeds/proto.osm"
},
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "Xcel",
"description": "Option 1 Description: Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "Report",
"description": "Option 1 Description"
}
]
},
{
"name": "Fan Coil DOAS",
"seed": {
"file_type": "OSM",
"path": "./seeds/proto.osm"
},
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "Fan Coil DOAS",
"description": "Option 1 Description"
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "Xcel",
"description": "Option 1 Description: Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "Report",
"description": "Option 1 Description"
}
]
},
{
"name": "VAV DX",
"seed": {
"file_type": "OSM",
"path": "./seeds/proto.osm"
},
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "VAV DX",
"description": "Option 1 Description"
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "Xcel",
"description": "Option 1 Description: Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "Report",
"description": "Option 1 Description"
}
]
},
{
"name": "Radiant DOAS",
"seed": {
"file_type": "OSM",
"path": "./seeds/proto.osm"
},
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "Radiant DOAS",
"description": "Option 1 Description"
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "Xcel",
"description": "Option 1 Description: Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "Report",
"description": "Option 1 Description"
}
]
},
{
"name": "VAV Chilled Water",
"seed": {
"file_type": "OSM",
"path": "./seeds/proto.osm"
},
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "VAV Chilled Water",
"description": "Option 1 Description"
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "Xcel",
"description": "Option 1 Description: Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "Report",
"description": "Option 1 Description"
}
]
},
{
"name": "Alternative 6",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 7",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 8",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 9",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 10",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 11",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 12",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 13",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 14",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 15",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 16",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 17",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 18",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 19",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 20",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 21",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 22",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 23",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 24",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 25",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 26",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 27",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
},
{
"name": "Alternative 28",
"options": [
{
"measure_name": "aedg_office_hvac_fan_coil_doas",
"workflow_index": 0,
"name": "aedg_office_hvac_fan_coil_doas",
"description": "Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_dx",
"workflow_index": 1,
"name": "aedg_office_hvac_vav_dx",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_radiant_doas",
"workflow_index": 2,
"name": "aedg_office_hvac_radiant_doas",
"description": "Measure replaces existing HVAC system (if any) with a Radiant Heating and Cooling with DOAS HVAC system (one DOAS per floor). The radiant with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "aedg_office_hvac_vav_ch_w",
"workflow_index": 3,
"name": "aedg_office_hvac_vav_ch_w",
"description": "Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG."
},
{
"measure_name": "xcel_eda_tariff_selectionand_model_setup",
"workflow_index": 4,
"name": "xcel_eda_tariff_selectionand_model_setup",
"description": "Add the selected Xcel utility rate, as well as set the timestep and lifecycle costing parameters as required by the Xcel EDA program."
},
{
"measure_name": "openstudio_results",
"workflow_index": 5,
"name": "openstudio_results",
"description": "This measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data."
}
]
}
]
},
"seed": {
"file_type": "OSM",
"path": "./seeds/SmallOffProto.osm"
},
"weather_file": {
"file_type": "EPW",
"path": "./weather/USA_CO_Golden-NREL.724666_TMY3.epw"
},
"file_format_version": 1,
"cli_debug": "",
"cli_verbose": "",
"download_reports": true,
"download_osw": true,
"download_osm": true,
"download_zip": true,
"run_workflow_timeout": 28800,
"upload_results_timeout": 28800,
"initialize_worker_timeout": 28800,
"server_scripts": {}
}
}
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment