Skip to content

Instantly share code, notes, and snippets.

@tracernz
Created March 16, 2018 07:43
Show Gist options
  • Star 0 You must be signed in to star a gist
  • Fork 0 You must be signed in to fork a gist
  • Save tracernz/e0b8d23655e6323b7e958da6b9a8a784 to your computer and use it in GitHub Desktop.
Save tracernz/e0b8d23655e6323b7e958da6b9a8a784 to your computer and use it in GitHub Desktop.
./scripts/save-test-data.php -o radwin -v 5550-0h50 -m wireless -d -n
Starting snmpsim listening on 127.1.6.1:1161...
snmpsimd.py --data-dir=/opt/librenms/tests/snmpsim/ --agent-udpv4-endpoint=127.1.6.1:1161 --logging-method=file:/tmp/snmpsimd.logOS: radwin
Module: wireless
Variant: 5550-0h50
SQL[SELECT `device_id` FROM `devices` WHERE `hostname` = '127.1.6.1']
SQL[SELECT * FROM `devices` WHERE `device_id` = '']
SQL[SELECT * FROM devices_attribs WHERE `device_id` = '']
No OS to loadSQL[SELECT * FROM `vrf_lite_cisco` WHERE `device_id` = '']
SQL[SELECT hostname FROM devices WHERE device_id = '']
SQL[SELECT COUNT(*) FROM `devices` WHERE `hostname`='127.1.6.1']
SQL[SELECT `name` FROM `port_association_mode` ORDER BY pom_id]
SQL[SELECT `ipv4_address_id` FROM `ipv4_addresses` WHERE `ipv4_address` = '127.1.6.1']
SQL[SELECT `pom_id` FROM `port_association_mode` WHERE name = 'ifIndex']
SNMP Check response code: 0
SQL[SELECT `pom_id` FROM `port_association_mode` WHERE name = 'ifIndex']
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -Ovq -M /opt/librenms/mibs udp:127.1.6.1:1161 SNMPv2-MIB::sysDescr.0]
Wireless Link
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -Ovqn -M /opt/librenms/mibs udp:127.1.6.1:1161 SNMPv2-MIB::sysObjectID.0]
.1.3.6.1.4.1.4458.20.6.1.1
| Wireless Link | .1.3.6.1.4.1.4458.20.6.1.1 |
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -Oqv -M /opt/librenms/mibs udp:127.1.6.1:1161 .1.3.6.1.4.1.12148.10.2.6.0]
No Such Instance currently exists at this OID
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -Oqv -m SNMPv2-MIB -M /opt/librenms/mibs udp:127.1.6.1:1161 sysName.0]
<private>
SQL[SELECT COUNT(*) FROM `devices` WHERE `hostname`='127.1.6.1' OR `sysName`='<private>']
SQL[INSERT INTO `devices` (`hostname`,`sysName`,`os`,`hardware`,`community`,`port`,`transport`,`status`,`snmpver`,`poller_group`,`status_reason`,`port_association_mode`,`snmp_disable`) VALUES ('127.1.6.1','127.1.6.1','radwin','','radwin_5550-0h50','1161','udp','1','v2c','0','','1','0')]
Added device: 31
SQL[SELECT * FROM `devices` WHERE `device_id` = '31']
SQL[SELECT * FROM devices_attribs WHERE `device_id` = '31']
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','NULL','system',NOW(),'3','Device type changed => wireless','')]
SQL[UPDATE `devices` set `type` ='wireless' WHERE device_id='31']
Device type changed to wireless!
SQL[SELECT * FROM `vrf_lite_cisco` WHERE `device_id` = '31']
SQL[SELECT * FROM devices_attribs WHERE `device_id` = '31']
127.1.6.1 31 radwin SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.01','0.02','0.01','31',NOW())]
SNMP Check response code: 0
SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '31' AND `attrib_type` = 'poll_mib' ]
Attempting to initialize OS: radwin
OS initialized: LibreNMS\OS\Radwin
Modules status: Global+ OS Device
#### Load disco module core ####
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs udp:127.1.6.1:1161 sysName.0 sysObjectID.0 sysDescr.0]
.1.3.6.1.2.1.1.5.0 = <private>
.1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.4458.20.6.1.1
.1.3.6.1.2.1.1.1.0 = Wireless Link
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','NULL','system',NOW(),'3','sysObjectID -> .1.3.6.1.4.1.4458.20.6.1.1','')]
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','NULL','system',NOW(),'3','sysName -> <private>','')]
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','NULL','system',NOW(),'3','sysDescr -> Wireless Link','')]
SQL[UPDATE `devices` set `sysObjectID` ='.1.3.6.1.4.1.4458.20.6.1.1',`sysName` ='<private>',`sysDescr` ='Wireless Link' WHERE device_id='31']
>> Runtime for discovery module 'core': 0.1940 seconds with 1152 bytes
>> SNMP: [7/1.03s] MySQL: [28/1.40s] RRD: [0/0.00s]
#### Unload disco module core ####
Modules status: Global+ OS+ Device
#### Load disco module wireless ####
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='ap-count']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='clients']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='quality']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='capacity']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='utilization']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='rate']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='ccq']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='snr']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='ssr']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='mse']
rssi: SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -OUQnt -M /opt/librenms/mibs udp:127.1.6.1:1161 .1.3.6.1.4.1.4458.1000.1.1.51.7.0]
.1.3.6.1.4.1.4458.1000.1.1.51.7.0 = -150
Discovered LibreNMS\Device\WirelessSensor Array
(
[sensor_class] => rssi
[device_id] => 31
[sensor_oids] => Array
(
[0] => .1.3.6.1.4.1.4458.1000.1.1.51.7.0
)
[sensor_index] => 0
[sensor_type] => radwin
[sensor_descr] => RSSI
[sensor_divisor] => 1
[sensor_multiplier] => 1
[sensor_aggregator] => sum
[sensor_limit] =>
[sensor_limit_warn] =>
[sensor_limit_low] =>
[sensor_limit_low_warn] =>
[sensor_current] =>
[entPhysicalIndex] =>
[entPhysicalIndex_measured] =>
[access_point_id] =>
)
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='rssi' AND `sensor_type`='radwin' AND `sensor_index`='0']
SQL[INSERT INTO `wireless_sensors` (`sensor_class`,`device_id`,`sensor_oids`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_aggregator`,`sensor_limit`,`sensor_limit_warn`,`sensor_limit_low`,`sensor_limit_low_warn`,`sensor_current`,`entPhysicalIndex`,`entPhysicalIndex_measured`,`access_point_id`) VALUES ('rssi','31','[\".1.3.6.1.4.1.4458.1000.1.1.51.7.0\"]','0','radwin','RSSI','1','1','sum',NULL,NULL,NULL,NULL,'-150',NULL,NULL,NULL)]
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','1','wireless_sensors',NOW(),'3','Wireless Sensor Discovered: rssi radwin 0 RSSI','')]
+SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='rssi' AND `sensor_id` NOT IN ('1')]
power: SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -OUQnt -M /opt/librenms/mibs udp:127.1.6.1:1161 .1.3.6.1.4.1.4458.1000.1.5.4.0]
.1.3.6.1.4.1.4458.1000.1.5.4.0 = -1
Discovered LibreNMS\Device\WirelessSensor Array
(
[sensor_class] => power
[device_id] => 31
[sensor_oids] => Array
(
[0] => .1.3.6.1.4.1.4458.1000.1.5.4.0
)
[sensor_index] => 0
[sensor_type] => Radwin-Tx
[sensor_descr] => Tx Power
[sensor_divisor] => 1
[sensor_multiplier] => 1
[sensor_aggregator] => sum
[sensor_limit] =>
[sensor_limit_warn] =>
[sensor_limit_low] =>
[sensor_limit_low_warn] =>
[sensor_current] =>
[entPhysicalIndex] =>
[entPhysicalIndex_measured] =>
[access_point_id] =>
)
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -OUQnt -M /opt/librenms/mibs udp:127.1.6.1:1161 .1.3.6.1.4.1.4458.1000.1.5.9.1.0]
.1.3.6.1.4.1.4458.1000.1.5.9.1.0 = -60
Discovered LibreNMS\Device\WirelessSensor Array
(
[sensor_class] => power
[device_id] => 31
[sensor_oids] => Array
(
[0] => .1.3.6.1.4.1.4458.1000.1.5.9.1.0
)
[sensor_index] => 0
[sensor_type] => Radwin-Rx
[sensor_descr] => Rx Power
[sensor_divisor] => 1
[sensor_multiplier] => 1
[sensor_aggregator] => sum
[sensor_limit] =>
[sensor_limit_warn] =>
[sensor_limit_low] =>
[sensor_limit_low_warn] =>
[sensor_current] =>
[entPhysicalIndex] =>
[entPhysicalIndex_measured] =>
[access_point_id] =>
)
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='power' AND `sensor_type`='Radwin-Tx' AND `sensor_index`='0']
SQL[INSERT INTO `wireless_sensors` (`sensor_class`,`device_id`,`sensor_oids`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_aggregator`,`sensor_limit`,`sensor_limit_warn`,`sensor_limit_low`,`sensor_limit_low_warn`,`sensor_current`,`entPhysicalIndex`,`entPhysicalIndex_measured`,`access_point_id`) VALUES ('power','31','[\".1.3.6.1.4.1.4458.1000.1.5.4.0\"]','0','Radwin-Tx','Tx Power','1','1','sum',NULL,NULL,NULL,NULL,'-1',NULL,NULL,NULL)]
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','2','wireless_sensors',NOW(),'3','Wireless Sensor Discovered: power Radwin-Tx 0 Tx Power','')]
+SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='power' AND `sensor_type`='Radwin-Rx' AND `sensor_index`='0']
SQL[INSERT INTO `wireless_sensors` (`sensor_class`,`device_id`,`sensor_oids`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_aggregator`,`sensor_limit`,`sensor_limit_warn`,`sensor_limit_low`,`sensor_limit_low_warn`,`sensor_current`,`entPhysicalIndex`,`entPhysicalIndex_measured`,`access_point_id`) VALUES ('power','31','[\".1.3.6.1.4.1.4458.1000.1.5.9.1.0\"]','0','Radwin-Rx','Rx Power','1','1','sum',NULL,NULL,NULL,NULL,'-60',NULL,NULL,NULL)]
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','3','wireless_sensors',NOW(),'3','Wireless Sensor Discovered: power Radwin-Rx 0 Rx Power','')]
+SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='power' AND `sensor_id` NOT IN ('2','3')]
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='noise-floor']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='errors']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='error-ratio']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='error-rate']
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='frequency']
distance: SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -OUQnt -M /opt/librenms/mibs udp:127.1.6.1:1161 .1.3.6.1.4.1.4458.1000.1.5.29.0]
.1.3.6.1.4.1.4458.1000.1.5.29.0 = 150
Discovered LibreNMS\Device\WirelessSensor Array
(
[sensor_class] => distance
[device_id] => 31
[sensor_oids] => Array
(
[0] => .1.3.6.1.4.1.4458.1000.1.5.29.0
)
[sensor_index] => 0
[sensor_type] => radwin
[sensor_descr] => Link distance
[sensor_divisor] => 1000
[sensor_multiplier] => 1
[sensor_aggregator] => sum
[sensor_limit] =>
[sensor_limit_warn] =>
[sensor_limit_low] =>
[sensor_limit_low_warn] =>
[sensor_current] =>
[entPhysicalIndex] =>
[entPhysicalIndex_measured] =>
[access_point_id] =>
)
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='distance' AND `sensor_type`='radwin' AND `sensor_index`='0']
SQL[INSERT INTO `wireless_sensors` (`sensor_class`,`device_id`,`sensor_oids`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_aggregator`,`sensor_limit`,`sensor_limit_warn`,`sensor_limit_low`,`sensor_limit_low_warn`,`sensor_current`,`entPhysicalIndex`,`entPhysicalIndex_measured`,`access_point_id`) VALUES ('distance','31','[\".1.3.6.1.4.1.4458.1000.1.5.29.0\"]','0','radwin','Link distance','1000','1','sum',NULL,NULL,NULL,NULL,'0.15',NULL,NULL,NULL)]
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','4','wireless_sensors',NOW(),'3','Wireless Sensor Discovered: distance radwin 0 Link distance','')]
+SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='31' AND `sensor_class`='distance' AND `sensor_id` NOT IN ('4')]
>> Runtime for discovery module 'wireless': 0.4110 seconds with 133784 bytes
>> SNMP: [4/0.06s] MySQL: [30/0.34s] RRD: [0/0.00s]
#### Unload disco module wireless ####
SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '31' AND `attrib_type` = 'poll_mib' ]
SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='1.667' WHERE `device_id` = '31']
Discovered in 1.667 seconds
SQL[SELECT * FROM `devices` WHERE `device_id` = '31']
SQL[SELECT * FROM devices_attribs WHERE `device_id` = '31']
SQL[SELECT * FROM `vrf_lite_cisco` WHERE `device_id` = '31']
SQL[SELECT * FROM devices_attribs WHERE `device_id` = '31']
Hostname: 127.1.6.1
Device ID: 31
OS: radwin
SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.01','0.02','0.01','31',NOW())]
SNMP Check response code: 0
Modules status: Global+ OS Device
#### Load poller module core ####
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -OQnUt -m SNMPv2-MIB -M /opt/librenms/mibs udp:127.1.6.1:1161 sysUpTime.0 sysLocation.0 sysContact.0 sysName.0 sysObjectID.0 sysDescr.0]
.1.3.6.1.2.1.1.3.0 = 200261300
.1.3.6.1.2.1.1.6.0 = <private>
.1.3.6.1.2.1.1.4.0 = <private>
.1.3.6.1.2.1.1.5.0 = <private>
.1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.4458.20.6.1.1
.1.3.6.1.2.1.1.1.0 = Wireless Link
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -OQnUst -m HOST-RESOURCES-MIB:SNMP-FRAMEWORK-MIB -M /opt/librenms/mibs udp:127.1.6.1:1161 snmpEngineTime.0 hrSystemUptime.0]
snmpEngineTime.0 = 2002623
hrSystemUptime.0 = No Such Instance currently exists at this OID
Uptime seconds: 2002623
RRD[create /opt/librenms/rrd/127.1.6.1/uptime.rrd --step 300 DS:uptime:GAUGE:600:0:U RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/uptime.rrd N:2002623]
Uptime: 23 days, 4h 17m 3s
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','NULL','system',NOW(),'3','sysContact -> <private>','')]
SQL[INSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('31','31','NULL','system',NOW(),'3','Location -> <private>','')]
SQL[SELECT `lat`,`lng` FROM `locations` WHERE `location`='<private>' LIMIT 1]
Using cached lat/lng from other device
>> Runtime for poller module 'core': 0.0984 seconds with 16176 bytes
>> SNMP: [2/0.02s] MySQL: [3/0.08s] RRD: [0/0.00s]
#### Unload poller module core ####
RRD[create /opt/librenms/rrd/127.1.6.1/poller-perf-core.rrd --step 300 DS:poller:GAUGE:600:0:U RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/poller-perf-core.rrd N:0.098367929458618]
Modules status: Global+ OS Device
#### Load poller module wireless ####
Attempting to initialize OS: radwin
OS initialized: LibreNMS\OS\Radwin
SQL[SELECT * FROM `wireless_sensors` WHERE `device_id` = '31']
SNMP[/usr/bin/snmpget -v2c -c 'radwin_5550-0h50' -OUQnt -M /opt/librenms/mibs udp:127.1.6.1:1161 .1.3.6.1.4.1.4458.1000.1.1.51.7.0 .1.3.6.1.4.1.4458.1000.1.5.4.0 .1.3.6.1.4.1.4458.1000.1.5.9.1.0 .1.3.6.1.4.1.4458.1000.1.5.29.0]
.1.3.6.1.4.1.4458.1000.1.1.51.7.0 = -150
.1.3.6.1.4.1.4458.1000.1.5.4.0 = -1
.1.3.6.1.4.1.4458.1000.1.5.9.1.0 = -60
.1.3.6.1.4.1.4458.1000.1.5.29.0 = 150
rssi:
Array
(
[1] => -150
)
RSSI: -150 dBm
RRD[create /opt/librenms/rrd/127.1.6.1/wireless-sensor-rssi-radwin-0.rrd --step 300 DS:sensor:GAUGE:600:U:U RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/wireless-sensor-rssi-radwin-0.rrd N:-150]
SQL[UPDATE `wireless_sensors` set `sensor_prev` ='-150',`sensor_current` ='-150',`lastupdate` =NOW() WHERE `sensor_id` = '1']
power:
Array
(
[2] => -1
[3] => -60
)
Tx Power: -1 dBm
RRD[create /opt/librenms/rrd/127.1.6.1/wireless-sensor-power-Radwin-Tx-0.rrd --step 300 DS:sensor:GAUGE:600:U:U RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/wireless-sensor-power-Radwin-Tx-0.rrd N:-1]
SQL[UPDATE `wireless_sensors` set `sensor_prev` ='-1',`sensor_current` ='-1',`lastupdate` =NOW() WHERE `sensor_id` = '2']
Rx Power: -60 dBm
RRD[create /opt/librenms/rrd/127.1.6.1/wireless-sensor-power-Radwin-Rx-0.rrd --step 300 DS:sensor:GAUGE:600:U:U RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/wireless-sensor-power-Radwin-Rx-0.rrd N:-60]
SQL[UPDATE `wireless_sensors` set `sensor_prev` ='-60',`sensor_current` ='-60',`lastupdate` =NOW() WHERE `sensor_id` = '3']
distance:
Array
(
[4] => 0.15
)
Link distance: 0.15 km
RRD[create /opt/librenms/rrd/127.1.6.1/wireless-sensor-distance-radwin-0.rrd --step 300 DS:sensor:GAUGE:600:U:U RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/wireless-sensor-distance-radwin-0.rrd N:0.15]
SQL[UPDATE `wireless_sensors` set `sensor_prev` ='0.15',`sensor_current` ='0.15',`lastupdate` =NOW() WHERE `sensor_id` = '4']
>> Runtime for poller module 'wireless': 0.5797 seconds with 6376 bytes
>> SNMP: [1/0.02s] MySQL: [5/0.56s] RRD: [0/0.00s]
#### Unload poller module wireless ####
RRD[create /opt/librenms/rrd/127.1.6.1/poller-perf-wireless.rrd --step 300 DS:poller:GAUGE:600:0:U RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/poller-perf-wireless.rrd N:0.57969689369202]
### Start Device Groups ###
SQL[SELECT * FROM device_groups ORDER BY name]
SQL[SELECT `device_group_id` FROM `device_group_device` WHERE `device_id`='31']
Groups Added:
Groups Removed:
### End Device Groups ###
RRD[create /opt/librenms/rrd/127.1.6.1/ping-perf.rrd --step 300 DS:ping:GAUGE:600:0:65535 RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/ping-perf.rrd N:0.01]
RRD[create /opt/librenms/rrd/127.1.6.1/poller-perf.rrd --step 300 DS:poller:GAUGE:600:0:U RRA:AVERAGE:0.5:1:2016 RRA:AVERAGE:0.5:6:1440 RRA:AVERAGE:0.5:24:1440 RRA:AVERAGE:0.5:288:1440 RRA:MIN:0.5:1:720 RRA:MIN:0.5:6:1440 RRA:MIN:0.5:24:775 RRA:MIN:0.5:288:797 RRA:MAX:0.5:1:720 RRA:MAX:0.5:6:1440 RRA:MAX:0.5:24:775 RRA:MAX:0.5:288:797 RRA:LAST:0.5:1:1440 ]
RRD[update /opt/librenms/rrd/127.1.6.1/poller-perf.rrd N:1.742]
Polled in 1.742 seconds
Updating 127.1.6.1
SQL[UPDATE `devices` set `uptime` ='2002623',`sysContact` ='<private>',`location` ='<private>',`last_ping` =NOW(),`last_ping_timetaken` ='0.01',`last_polled` =NOW(),`last_polled_timetaken` ='1.742' WHERE `device_id` = '31']
UPDATED!
Array
(
)
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment