#!/bin/bash | |
# This is a modified version of the Supermicro PID Logic Fan Script from https://forums.freenas.org/index.php?resources/fan-scripts-for-supermicro-boards-using-pid-logic.24/ | |
# and is designed to run on Supermicro X9 boards using an Nuvoton WPCM450 BMC. | |
# | |
# IPMI raw commands are gathered from https://www.supermicro.com/support/faqs/faq.cfm?faq=15634 | |
# and https://www.reddit.com/r/homelab/comments/8fhomj/getting_those_supermicro_x9_motherboard_fans/ | |
# | |
# Attention: When i modified this script, i had already configured full fan mode via ipmi web interface. | |
# Therefore this script may not enable full fan mode. Please enable it manually, otherwise the ipmi | |
# fancontrol will interfere with this script. | |
# | |
# Attention: This script is designed to run in a VM and therefore accesses ipmi over the network | |
# Please add your ipmi login credentials in the line beginning with "IPMITOOL=" or change it | |
# to the standard hardware access mode. | |
# spinpid2.sh for dual fan zones. | |
VERSION="2020-05-37" | |
# Run as superuser. See notes at end. | |
############################################## | |
# | |
# Settings | |
# | |
############################################## | |
################# LOG SETTINGS ################ | |
# Create logfile and sends all stdout and stderr to the log, as well as to the console. | |
# To append to existing log, add '-a' to the tee command. | |
LOG=/var/log/fancontrol/fan.log # Change to your desired log location/name | |
exec > >(tee -i $LOG) 2>&1 | |
# CPU output sent to a separate log for interim cycles | |
CPU_LOG=/var/log/fancontrol/cpu.log | |
################# FAN SETTINGS ################ | |
# Supermicro says: | |
# Zone 0 - CPU/System fans, headers with number (e.g., FAN1, FAN2, etc.) | |
# Zone 1 - Peripheral fans, headers with letter (e.g., FANA, FANB, etc.) | |
# Some want the reverse (i.e, drive cooling fans on headers FAN1-4 and | |
# CPU fan on FANA), so that's the default. But you can switch to SM way. | |
ZONE_CPU=1 | |
ZONE_PER=0 | |
# Set min and max duty cycle to avoid stalling or zombie apocalypse | |
DUTY_PER_MIN=5 | |
DUTY_PER_MAX=50 | |
DUTY_CPU_MIN=5 | |
DUTY_CPU_MAX=50 | |
# Your measured fan RPMs at 30% duty cycle and 100% duty cycle | |
# RPM_CPU is for FANA if ZONE_CPU=1 or FAN1 if ZONE_CPU=0 | |
# RPM_PER is for the other fan. | |
# These are my settings for a 36-bay SC847 case using the original fans | |
RPM_CPU_30=4000 # adapt these for your system | |
RPM_CPU_MAX=7000 | |
RPM_PER_30=3450 | |
RPM_PER_MAX=7125 | |
# RPM_CPU_30=500 # My system | |
# RPM_CPU_MAX=1400 | |
# RPM_PER_30=500 | |
# RPM_PER_MAX=1400 | |
################# DRIVE SETTINGS ################ | |
SP=37 # Setpoint mean drive temperature (C) | |
DRIVE_T=1 # time interval for checking drives (minutes). Drives change | |
# temperature slowly; 5 minutes should be frequent enough. | |
Kp=4 # Proportional tunable constant | |
Ki=0 # Integral tunable constant | |
Kd=40 # Derivative tunable constant | |
################# CPU SETTINGS ################ | |
# Time interval for checking CPU (seconds). 1 to 12 may be appropriate | |
CPU_T=3 | |
# Reference temperature (C) for scaling CPU_DUTY (NOT a setpoint). | |
# At and below this temperature, CPU will demand minimum | |
# duty cycle (DUTY_CPU_MIN). | |
CPU_REF=55 # Integer only! | |
# Scalar for scaling CPU_DUTY. | |
# CPU will demand this number of percentage points in additional | |
# duty cycle for each degree of temperature above CPU_REF. | |
CPU_SCALE=4 # Integer only! | |
################# OTHER SETTINGS ################ | |
# Duty cycle isn't provided reliably by all boards. Therefore, by | |
# default we don't try to read them, and the script just assumes | |
# that they are what the script last set. If you want to try reading them, | |
# go to the function read_fan_data and uncomment the first 4 lines, | |
# where it reads/converts duty cycles. | |
IPMITOOL="/usr/bin/ipmitool -I lanplus -H 192.168.1.80 -U fancontrol -Pfancontrol" | |
# Get list of drives | |
DEVLIST="sda | |
sdb | |
sdc | |
sdd | |
sde | |
sdf | |
sdh | |
sdi | |
sdj | |
" | |
############################################## | |
# function get_disk_name | |
# Get disk name from current LINE of DEVLIST | |
############################################## | |
# The awk statement works by taking $LINE as input, | |
# setting '(' as a _F_ield separator and taking the second field it separates | |
# (ie after the separator), passing that to another awk that uses | |
# ',' as a separator, and taking the first field (ie before the separator). | |
# In other words, everything between '(' and ',' is kept. | |
# camcontrol output for disks on HBA seems to change every version, | |
# so need 2 options to get ada/da disk name. | |
function get_disk_name { | |
DEVID=$LINE | |
} | |
############################################################ | |
# function print_header | |
# Called when script starts and each quarter day | |
############################################################ | |
function print_header { | |
DATE=$(date +"%A, %b %d") | |
let "SPACES = DEVCOUNT * 5 + 48" # 5 spaces per drive | |
printf "\n%-*s %3s %16s %29s \n" $SPACES "$DATE" "CPU" "New_Fan%" "New_RPM___________________________________" | |
echo -n " " | |
while read -r LINE ; do | |
get_disk_name | |
printf "%-5s" "$DEVID" | |
done <<< "$DEVLIST" # while statement works on DEVLIST | |
printf "%4s %5s %6s %6s %5s %6s %3s %-7s %s %-4s %5s %5s %5s %5s %5s %5s %5s %5s" "Tmax" "Tmean" "ERRc" "P" "I" "D" "TEMP" "MODE" "CPU" "PER" "FANA" "FANB" "FAN1" "FAN2" "FAN3" "FAN4" "FAN5" "FAN6" | |
} | |
################################################# | |
# function read_fan_data | |
################################################# | |
function read_fan_data { | |
# Read duty cycles, convert to decimal. This is commented out by | |
# default because some boards report incorrect data. In this case, | |
# the script will set the duty cycles and assume those values. | |
# DUTY_CPU=$($IPMITOOL raw 0x30 0x70 0x66 0 $ZONE_CPU) # in hex with leading space | |
# DUTY_CPU=$((0x$(echo $DUTY_CPU))) # strip leading space and decimalize | |
# DUTY_PER=$($IPMITOOL raw 0x30 0x70 0x66 0 $ZONE_PER) | |
# DUTY_PER=$((0x$(echo $DUTY_PER))) | |
# Read fan mode, convert to decimal, get text equivalent. | |
# haven't tested, but i think this should be raw 0x30 0x91 0 | |
# i had already set it to full fan mode via ipmi web interface | |
MODE=$($IPMITOOL raw 0x30 0x45 0) # in hex with leading space | |
MODE=$((0x$(echo $MODE))) # strip leading space and decimalize | |
# Text for mode | |
case $MODE in | |
0) MODEt="Standard" ;; | |
1) MODEt="Full" ;; | |
2) MODEt="Optimal" ;; | |
4) MODEt="HeavyIO" ;; | |
esac | |
# Get reported fan speed in RPM from sensor data repository. | |
# Takes the pertinent FAN line, then 3 to 5 consecutive digits | |
SDR=$($IPMITOOL sdr) | |
FAN1=$(echo "$SDR" | grep "FAN1" | grep -Eo '[0-9]{3,5}') | |
FAN2=$(echo "$SDR" | grep "FAN2" | grep -Eo '[0-9]{3,5}') | |
FAN3=$(echo "$SDR" | grep "FAN3" | grep -Eo '[0-9]{3,5}') | |
FAN4=$(echo "$SDR" | grep "FAN4" | grep -Eo '[0-9]{3,5}') | |
FAN5=$(echo "$SDR" | grep "FAN5" | grep -Eo '[0-9]{3,5}') | |
FAN6=$(echo "$SDR" | grep "FAN6" | grep -Eo '[0-9]{3,5}') | |
FANA=$(echo "$SDR" | grep "FANA" | grep -Eo '[0-9]{3,5}') | |
FANB=$(echo "$SDR" | grep "FANB" | grep -Eo '[0-9]{3,5}') | |
} | |
############################################## | |
# function CPU_check_adjust | |
# Get CPU temp. Calculate a new DUTY_CPU. | |
# Send to function adjust_fans. | |
############################################## | |
function CPU_check_adjust { | |
# Old methods of checking CPU temp: | |
# CPU_TEMP=$($IPMITOOL sdr | grep "CPU Temp" | grep -Eo '[0-9]{2,5}') | |
# CPU_TEMP=$($IPMITOOL sensor get "CPU Temp" | awk '/Sensor Reading/ {print $4}') | |
# Hint: second one is much faster, reads only cpu instead of all sensors | |
CPU_TEMP1=$($IPMITOOL sensor get "CPU1 Temp" | awk '/Sensor Reading/ {print $4}') | |
CPU_TEMP2=$($IPMITOOL sensor get "CPU2 Temp" | awk '/Sensor Reading/ {print $4}') | |
if [[ $CPU_TEMP1 -gt $CPU_TEMP2 ]]; then CPU_TEMP=$CPU_TEMP1; else CPU_TEMP=$CPU_TEMP2; fi | |
#CPU_TEMP=$CPU_TEMP2 | |
#CPU_TEMP="$(( CPU_TEMP1 > CPU_TEMP2 ? CPU_TEMP1 : CPU_TEMP2 ))" | |
# Find hottest CPU core | |
#Hint: not possible in a VM, read CPU temp via IPMI above | |
#MAX_CORE_TEMP=0 | |
#for CORE in $(seq 0 $CORES) | |
#do | |
# CORE_TEMP="$(sysctl -n dev.cpu.${CORE}.temperature | awk -F '.' '{print$1}')" | |
# if [[ $CORE_TEMP -gt $MAX_CORE_TEMP ]]; then MAX_CORE_TEMP=$CORE_TEMP; fi | |
#done | |
#CPU_TEMP=$MAX_CORE_TEMP | |
DUTY_CPU_LAST=$DUTY_CPU | |
# This will break if settings have non-integers | |
let DUTY_CPU="$(( (CPU_TEMP-CPU_REF)*CPU_SCALE+DUTY_CPU_MIN ))" | |
# Don't allow duty cycle outside min-max | |
if [[ $DUTY_CPU -gt $DUTY_CPU_MAX ]]; then DUTY_CPU=$DUTY_CPU_MAX; fi | |
if [[ $DUTY_CPU -lt $DUTY_CPU_MIN ]]; then DUTY_CPU=$DUTY_CPU_MIN; fi | |
adjust_fans $ZONE_CPU $DUTY_CPU $DUTY_CPU_LAST | |
if [[ $DUTY_CPU -gt $DUTY_PER ]]; then | |
adjust_fans $ZONE_PER $DUTY_CPU $DUTY_CPU_LAST | |
else | |
adjust_fans $ZONE_PER $DUTY_PER $DUTY_PER_LAST | |
fi | |
sleep $CPU_T | |
print_interim_CPU | tee -a $CPU_LOG >/dev/null | |
} | |
############################################## | |
# function DRIVES_check_adjust | |
# Print time on new log line. | |
# Go through each drive, getting and printing | |
# status and temp. Calculate max and mean | |
# temp, then calculate PID and new duty. | |
# Call adjust_fans. | |
############################################## | |
function DRIVES_check_adjust { | |
echo # start new line | |
# print time on each line | |
TIME=$(date "+%H:%M:%S"); echo -n "$TIME " | |
Tmax=0; Tsum=0 # initialize drive temps for new loop through drives | |
i=0 # initialize count of spinning drives | |
while read -r LINE ; do | |
get_disk_name | |
/usr/sbin/smartctl -a -n standby "/dev/$DEVID" > /var/tempfile | |
RETURN=$? # have to preserve return value or it changes | |
BIT0=$(( RETURN & 1 )) | |
BIT1=$(( RETURN & 2 )) | |
if [ $BIT0 -eq 0 ]; then | |
if [ $BIT1 -eq 0 ]; then | |
STATUS="*" # spinning | |
else # drive found but no response, probably standby | |
STATUS="_" | |
fi | |
else # smartctl returns 1 (00000001) for missing drive | |
STATUS="?" | |
fi | |
TEMP="" | |
# Update temperatures each drive; spinners only | |
if [ "$STATUS" == "*" ] ; then | |
# Taking 10th space-delimited field for WD, Seagate, Toshiba, Hitachi | |
TEMP=$( grep "Temperature_Celsius" /var/tempfile | awk '{print $10}') | |
let "Tsum = $Tsum+$TEMP" | |
if [[ $TEMP > $Tmax ]]; then Tmax=$TEMP; fi; | |
let i=i+1 | |
fi | |
printf "%s%-2d " "$STATUS" "$TEMP" | |
done <<< "$DEVLIST" | |
DUTY_PER_LAST=$DUTY_PER | |
# if no disks are spinning | |
if [ $i -eq 0 ]; then | |
Tmean=""; Tmax=""; P=""; D=""; ERRc="" | |
DUTY_PER=$DUTY_PER_MIN | |
else | |
# summarize, calculate PID and print Tmax and Tmean | |
if [[ $ERRc == "" ]]; then ERRc=0; fi # Need value if all drives had been spun down last time | |
Tmean=$(echo "scale=3; $Tsum / $i" | bc) | |
ERRp=$ERRc | |
ERRc=$(echo "scale=3; ($Tmean - $SP) / 1" | bc) | |
# For accurate calc of D, we should round ERRc now as ERRp is | |
ERRc=$(printf %0.2f "$ERRc") | |
P=$(echo "scale=3; ($Kp * $ERRc) / 1" | bc) | |
ERR=$(echo "$ERRc * $DRIVE_T + $I" | bc) | |
I=$(echo "scale=2; ($Ki * $ERR) / 1" | bc) | |
D=$(echo "scale=3; $Kd * ($ERRc - $ERRp) / $DRIVE_T" | bc) | |
PID=$(echo "$P + $I + $D" | bc) # add 3 corrections | |
# round for printing | |
Tmean=$(printf %0.2f "$Tmean") | |
P=$(printf %0.2f "$P") | |
D=$(printf %0.2f "$D") | |
PID=$(printf %0.f "$PID") # must be integer for duty | |
let "DUTY_PER = $DUTY_PER_LAST + $PID" | |
# Don't allow duty cycle outside min-max | |
if [[ $DUTY_PER -gt $DUTY_PER_MAX ]]; then DUTY_PER=$DUTY_PER_MAX; fi | |
if [[ $DUTY_PER -lt $DUTY_PER_MIN ]]; then DUTY_PER=$DUTY_PER_MIN; fi | |
fi | |
# DIAGNOSTIC variables - uncomment for troubleshooting: | |
# printf "\n DUTY_PER=%s, DUTY_PER_LAST=%s, DUTY=%s, Tmean=%s, ERRp=%s \n" "${DUTY_PER:---}" "${DUTY_PER_LAST:---}" "${DUTY:---}" "${Tmean:---}" $ERRp | |
# pass to the function adjust_fans | |
adjust_fans $ZONE_PER $DUTY_PER $DUTY_PER_LAST | |
# DIAGNOSTIC variables - uncomment for troubleshooting: | |
# printf "\n DUTY_PER=%s, DUTY_PER_LAST=%s, DUTY=%s, Tmean=%s, ERRp=%s \n" "${DUTY_PER:---}" "${DUTY_PER_LAST:---}" "${DUTY:---}" "${Tmean:---}" $ERRp | |
# print current Tmax, Tmean | |
printf "^%-3s %5s" "${Tmax:---}" "${Tmean:----}" | |
} | |
############################################## | |
# function adjust_fans | |
# Zone, new duty, and last duty are passed as parameters | |
############################################## | |
function adjust_fans { | |
# parameters passed to this function | |
ZONE=$1 | |
DUTY=$2 | |
DUTY_LAST=$3 | |
# Change if different from last duty, update last duty. | |
if [[ $DUTY -ne $DUTY_LAST ]] || [[ FIRST_TIME -eq 1 ]]; then | |
# Set new duty cycle. "echo -n ``" prevents newline generated in log | |
# Hint: IPMI needs 0-255, not 0-100 | |
SPEED=$(echo "scale=0; ($DUTY * 255) / 100" | bc) | |
echo -n "$($IPMITOOL raw 0x30 0x91 0x5A 0x3 0x1"$ZONE" "$SPEED")" | |
fi | |
} | |
############################################## | |
# function print_interim_CPU | |
# Sent to a separate file by the call | |
# in CPU_check_adjust{} | |
############################################## | |
function print_interim_CPU { | |
RPM=$($IPMITOOL sdr | grep "$RPM_CPU" | grep -Eo '[0-9]{2,5}') | |
# print time on each line | |
TIME=$(date "+%H:%M:%S"); echo -n "$TIME " | |
printf "%7s %5d %5d \n" "${RPM:----}" "$CPU_TEMP" "$DUTY" | |
} | |
##################################################### | |
# SETUP | |
# All this happens only at the beginning | |
# Initializing values, list of drives, print header | |
##################################################### | |
# Print settings at beginning of log | |
printf "\n****** SETTINGS ******\n" | |
printf "CPU zone %s; Peripheral zone %s\n" $ZONE_CPU $ZONE_PER | |
printf "CPU fans min/max duty cycle: %s/%s\n" $DUTY_CPU_MIN $DUTY_CPU_MAX | |
printf "PER fans min/max duty cycle: %s/%s\n" $DUTY_PER_MIN $DUTY_PER_MAX | |
printf "CPU fans - measured RPMs at 30% and 100% duty cycle: %s/%s\n" $RPM_CPU_30 $RPM_CPU_MAX | |
printf "PER fans - measured RPMs at 30% and 100% duty cycle: %s/%s\n" $RPM_PER_30 $RPM_PER_MAX | |
printf "Drive temperature setpoint (C): %s\n" $SP | |
printf "Kp=%s, Ki=%s, Kd=%s\n" $Kp $Ki $Kd | |
printf "Drive check interval (main cycle; minutes): %s\n" $DRIVE_T | |
printf "CPU check interval (seconds): %s\n" $CPU_T | |
printf "CPU reference temperature (C): %s\n" $CPU_REF | |
printf "CPU scalar: %s\n" $CPU_SCALE | |
# Get number of CPU cores to check for temperature | |
# -1 because numbering starts at 0 | |
#CORES=$(($(sysctl -n hw.ncpu)-1)) | |
CPU_LOOPS=$( echo "$DRIVE_T * 60 / $CPU_T" | bc ) # Number of whole CPU loops per drive loop | |
# standard IPMI hardware access | |
#IPMITOOL=/usr/local/bin/ipmitool | |
# i run freenas in a VM, so i can only use network access | |
I=0; ERRc=0 # Initialize errors to 0 | |
FIRST_TIME=1 | |
# Alter RPM thresholds to allow some slop | |
RPM_CPU_30=$(echo "scale=0; 1.2 * $RPM_CPU_30 / 1" | bc) | |
RPM_CPU_MAX=$(echo "scale=0; 0.8 * $RPM_CPU_MAX / 1" | bc) | |
RPM_PER_30=$(echo "scale=0; 1.2 * $RPM_PER_30 / 1" | bc) | |
RPM_PER_MAX=$(echo "scale=0; 0.8 * $RPM_PER_MAX / 1" | bc) | |
# Remove lines with flash drives, SSDs, other non-spinning devices; edit as needed | |
# and remove virtual drives from ESXi and Xenserver/xcp-ng | |
#DEVLIST="$(echo "$DEVLIST1"|sed '/QEMU/d;/VMware/d;/KINGSTON/d;/ADATA/d;/SanDisk/d;/OCZ/d;/LSI/d;/INTEL/d;/TDKMedia/d;/SSD/d')" | |
DEVCOUNT=$(echo "$DEVLIST" | wc -l) | |
echo "Number of drives : $DEVCOUNT" | |
# These variables hold the name of the other variables, whose | |
# value will be obtained by indirect reference | |
if [[ ZONE_PER -eq 0 ]]; then | |
RPM_PER=FAN1 | |
RPM_CPU=FANA | |
else | |
RPM_PER=FANA | |
RPM_CPU=FAN1 | |
fi | |
read_fan_data | |
# If mode not Full, set it to avoid BMC changing duty cycle | |
# Need to wait a tick or it may not get next command | |
# "echo -n" to avoid annoying newline generated in log | |
if [[ MODE -ne 1 ]]; then | |
# haven't tested, but i think this should be raw 0x30 0x91 0x5A 0x3 0x1 0x0 | |
# i had already set it to full fan mode via ipmi web interface | |
echo -n "$($IPMITOOL raw 0x30 0x45 0x01 0x01)" | |
sleep 1 | |
fi | |
# Need to start drive duty at a reasonable value if fans are | |
# going fast or we didn't read DUTY_* in read_fan_data | |
# (second test is TRUE if unset). | |
if [[ ${!RPM_PER} -ge RPM_PER_MAX || -z ${DUTY_PER+x} ]]; then | |
echo -n "$($IPMITOOL raw 0x30 0x91 0x5A 0x3 0x1$ZONE_PER 127)" | |
DUTY_PER=50 | |
fi | |
if [[ ${!RPM_CPU} -ge RPM_CPU_MAX || -z ${DUTY_CPU+x} ]]; then | |
echo -n "$($IPMITOOL raw 0x30 0x91 0x5A 0x3 0x1$ZONE_CPU 127)" | |
DUTY_CPU=50 | |
fi | |
# Before starting, go through the drives to report if | |
# smartctl return value indicates a problem (>2). | |
# Use -a so that all return values are available. | |
while read -r LINE ; do | |
get_disk_name | |
/usr/sbin/smartctl -a -n standby "/dev/$DEVID" > /var/tempfile | |
if [ $? -gt 2 ]; then | |
printf "\n" | |
printf "*******************************************************\n" | |
printf "* WARNING - Drive %-4s has a record of past errors, *\n" "$DEVID" | |
printf "* is currently failing, or is not communicating well. *\n" | |
printf "* Use smartctl to examine the condition of this drive *\n" | |
printf "* and conduct tests. Status symbol for the drive may *\n" | |
printf "* be incorrect (but probably not). *\n" | |
printf "*******************************************************\n" | |
fi | |
done <<< "$DEVLIST" | |
printf "\n%s %36s %s \n" "Key to drive status symbols: * spinning; _ standby; ? unknown" "Version" $VERSION | |
print_header | |
# for first round of printing | |
#CPU_TEMP=$(echo "$SDR" | grep "CPU1 Temp" | grep -Eo '[0-9]{2,5}') | |
CPU_TEMP1=$($IPMITOOL sensor get "CPU1 Temp" | awk '/Sensor Reading/ {print $4}') | |
CPU_TEMP2=$($IPMITOOL sensor get "CPU2 Temp" | awk '/Sensor Reading/ {print $4}') | |
if [[ $CPU_TEMP1 -gt $CPU_TEMP2 ]]; then CPU_TEMP=$CPU_TEMP1; else CPU_TEMP=$CPU_TEMP2; fi | |
# Initialize CPU log | |
printf "%s \n%s \n%17s %5s %5s \n" "$DATE" "Printed every CPU cycle" $RPM_CPU "Temp" "Duty" | tee $CPU_LOG >/dev/null | |
########################################### | |
# Main loop through drives every DRIVE_T minutes | |
# and CPU every CPU_T seconds | |
########################################### | |
while true ; do | |
# Print header every quarter day. awk removes any | |
# leading 0 so it is not seen as octal | |
HM=$(date +%k%M) | |
HM=$( echo $HM | awk '{print $1 + 0}' ) | |
R=$(( HM % 600 )) # remainder after dividing by 6 hours | |
if (( R < DRIVE_T )); then | |
print_header; | |
fi | |
DRIVES_check_adjust | |
sleep 5 # Let fans equilibrate to duty before reading fans and testing for reset | |
read_fan_data | |
FIRST_TIME=0 | |
printf "%7s %6s %5s %6.6s %4s %-7s %3d %3d %6s %5s %5s %5s %5s %5s %5s %5s" "${ERRc:----}" "${P:----}" $I "${D:----}" "$CPU_TEMP" $MODEt $DUTY_CPU $DUTY_PER "${FANA:----}" "${FANB:----}" "${FAN1:----}" "${FAN2:----}" "${FAN3:----}" "${FAN4:----}" "${FAN5:----}" "${FAN6:----}" | |
# See if BMC reset is needed | |
# ${!RPM_CPU} gets updated value of the variable RPM_CPU points to | |
if [[ (DUTY_CPU -ge 95 && ${!RPM_CPU} -lt RPM_CPU_MAX) || \ | |
(DUTY_CPU -le 30 && ${!RPM_CPU} -gt RPM_CPU_30) ]] ; then | |
$IPMITOOL bmc reset cold | |
printf "\n%s\n" "DUTY_CPU=$DUTY_CPU; RPM_CPU=${!RPM_CPU} -- I reset the BMC because RPMs were too high or low for DUTY_CPU" | |
sleep 60 | |
fi | |
if [[ (DUTY_PER -ge 95 && ${!RPM_PER} -lt RPM_PER_MAX) || \ | |
(DUTY_PER -le 30 && ${!RPM_PER} -gt RPM_PER_30) ]] ; then | |
$IPMITOOL bmc reset cold | |
printf "\n%s\n" "DUTY_PER=$DUTY_PER; RPM_PER=${!RPM_PER} -- I reset the BMC because RPMs were too high or low for DUTY_PER" | |
sleep 60 | |
fi | |
i=0 | |
while [ $i -lt "$CPU_LOOPS" ]; do | |
CPU_check_adjust | |
let i=i+1 | |
done | |
done | |
# For SuperMicro motherboards with dual fan zones. | |
# Adjusts fans based on drive and CPU temperatures. | |
# Includes disks on motherboard and on HBA. | |
# Mean drive temp is maintained at a setpoint using a PID algorithm. | |
# CPU temp need not and cannot be maintained at a setpoint, | |
# so PID is not used; instead fan duty cycle is simply | |
# increased with temp using reference and scale settings. | |
# Drives are checked and fans adjusted on a set interval, such as 5 minutes. | |
# Logging is done at that point. CPU temps can spike much faster, | |
# so are checked and logged at a shorter interval, such as 1-15 seconds. | |
# CPUs with high TDP probably require short intervals. | |
# Logs: | |
# - Disk status (* spinning or _ standby) | |
# - Disk temperature (Celsius) if spinning | |
# - Max and mean disk temperature | |
# - Temperature error and PID variables | |
# - CPU temperature | |
# - RPM for FANA and FAN1-4 before new duty cycles | |
# - Fan mode | |
# - New fan duty cycle in each zone | |
# - In CPU log: | |
# - RPM of the first fan in CPU zone (FANA or FAN1 | |
# - CPU temperature | |
# - new CPU duty cycle | |
# Relation between percent duty cycle, hex value of that number, | |
# and RPMs for my fans. RPM will vary among fans, is not | |
# precisely related to duty cycle, and does not matter to the script. | |
# It is merely reported. | |
# | |
# Hint: this table is wrong, duty cycles 0-100 are sent as 0-255 to IPMI | |
# | |
# Percent Hex RPM | |
# 10 A 300 | |
# 20 14 400 | |
# 30 1E 500 | |
# 40 28 600/700 | |
# 50 32 800 | |
# 60 3C 900 | |
# 70 46 1000/1100 | |
# 80 50 1100/1200 | |
# 90 5A 1200/1300 | |
# 100 64 1300 | |
# Because some Supermicro boards report incorrect duty cycle, | |
# you have the option of not reading that, assuming it is what we set. | |
# Tuning suggestions | |
# PID tuning advice on the internet generally does not work well in this application. | |
# First run the script spincheck.sh and get familiar with your temperature and fan variations without any intervention. | |
# Choose a setpoint that is an actual observed Tmean, given the number of drives you have. It should be the Tmean associated with the Tmax that you want. | |
# Set Ki=0 and leave it there. You probably will never need it. | |
# Start with Kp low. Use a value that results in a rounded correction=1 when error is the lowest value you observe other than 0 (i.e., when ERRc is minimal, Kp ~= 1 / ERRc) | |
# Set Kd at about Kp*10 | |
# Get Tmean within ~0.3 degree of SP before starting script. | |
# Start script and run for a few hours or so. If Tmean oscillates (best to graph it), you probably need to reduce Kd. If no oscillation but response is too slow, raise Kd. | |
# Stop script and get Tmean at least 1 C off SP. Restart. If there is overshoot and it goes through some cycles, you may need to reduce Kd. | |
# If you have problems, examine PK and PD in the log and see which is messing you up. If all else fails you can try Ki. If you use Ki, make it small, ~ 0.1 or less. | |
# Uses joeschmuck's smartctl method for drive status (returns 0 if spinning, 2 in standby) | |
# https://forums.freenas.org/index.php?threads/how-to-find-out-if-a-drive-is-spinning-down-properly.2068/#post-28451 | |
# Other method (camcontrol cmd -a) doesn't work with HBA |