Save Lukelectro/6bc73188276159ed62dfa3f00e8d41de to your computer and use it in GitHub Desktop.
How to read data from SDS011 sensor via USB serial connection, from http://opengeiger.de/Feinstaub/FeinstaubDatenLogger.pdf
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
#!/bin/bash | |
# Anpassung für big endian unter RHEL 7 | |
WDIR=~ | |
while true; do | |
stty -F /dev/ttyUSB0 9600 raw | |
INPUT=$(dd conv=swab bs=10 count=1 </dev/ttyUSB0 2>/dev/null | od -x -N10 |head -n 1|cut -f2-10 -d" "); | |
#Ausgabe | |
#echo $INPUT | |
#echo " " | |
FIRST4BYTES=$(echo $INPUT|cut -b1-4); | |
#echo $FIRST4BYTES | |
if [ "$FIRST4BYTES" = "aac0" ]; then | |
# echo "check for correct intro characters: ok" | |
echo " " | |
else | |
echo "incorrect sequence, exiting" | |
exit; | |
fi | |
PPM25LOW=$(echo $INPUT|cut -f2 -d " "|cut -b1-2); | |
PPM25HIGH=$(echo $INPUT|cut -f2 -d " "|cut -b3-4); | |
PPM10LOW=$(echo $INPUT|cut -f3 -d " "|cut -b1-2); | |
PPM10HIGH=$(echo $INPUT|cut -f3 -d " "|cut -b3-4); | |
#zu Dezimal konvertieren | |
PPM25LOWDEC=$( echo $((0x$PPM25LOW)) ); | |
PPM25HIGHDEC=$( echo $((0x$PPM25HIGH)) ); | |
PPM10LOWDEC=$( echo $((0x$PPM10LOW)) ); | |
PPM10HIGHDEC=$( echo $((0x$PPM10HIGH)) ); | |
PPM25=$(echo "scale=1;((( $PPM25HIGHDEC * 256 ) + $PPM25LOWDEC ) / 10 )"|bc -l ); | |
PPM10=$(echo "scale=1;((( $PPM10HIGHDEC * 256 ) + $PPM10LOWDEC ) / 10 )"|bc -l ); | |
echo "Feinstaub PPM25: $PPM25" | |
echo "Feinstaub PPM10: $PPM10" | |
done |