Specifications of the Agilent Technologies DSO-X 2024A

Key Features & Specifications

  • See more of your signal more of the time
    • Largest screen in its class: 8.5-inch WVGA display
    • Fastest update rate of 50,000 waveforms per second
    • Deepest memory: 100 kpts standard, up to 1 Mpts optional
  • Do more with the power of 5 instruments in 1:
    • Best-in-class oscilloscope
    • Integrated logic analyzer (MSO, Optional and upgradable with DSOX2MSO)
    • Only hardware-based serial-bus protocol analyzer
    • Only built-in 20-MHz function generator: WaveGen
    • Only built-in 3-digit voltmeter
  • Get more investment protection
    • Upgradability: add bandwidth, digital channels, memory, serial analysis, DVM or WaveGen after purchase
    • Segmented memory
    • Mask Testing

Specification overview

  • Bandwidth (–3 dB): 200 MHz
  • Calculated rise time (10-90%): ≤ 1.75 ns
  • Input channels: 4
  • Maximum sample rate: 2 GSa/s half-channel interleaved, 1 GSa/s per channel
  • Maximum memory depth: 100 kpts per channel (standard), 1 Mpt per channel (optional with DSOX2MEMUP)
  • Display size and type: 8.5-inch WVGA with 64 levels of intensity grading
  • Waveform update rate: > 50,000 waveforms per second

Vertical system analog channels

  • Input coupling: AC, DC
  • Input sensitivity range: 1 mV/div to 5 V/div**
  • Input impedance: 1 MΩ ± 2% (11 pF)
  • Vertical resolution: 8 bits
  • Dynamic range: ±8 divisions from center screen
  • Maximum input voltage:
    • CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk
    • CAT II 300 Vrms, 400 Vpk; with N2862B or N2863B 10:1 probe: 300 Vrms
  • DC vertical accuracy: ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
  • DC vertical gain accuracy: ±3% full scale (≥ 10 mV/div); ±4% full scale (< 10 mV/div) **
  • DC vertical offset accuracy: ±0.1 div ± 2mV ±1% of offset setting
  • Channel-to-channel isolation:
    • 200 MHz ~ 1 GHz: ≥ 40 dB from DC to maximum specified bandwidth of each model
    • 1.5 GHz: ≥ 40 dB from DC to 1 GHz, ≥ 35 dB from 1 GHz to 1.5 GHz
  • Position/offset range: 1 mV to 200 mV/div: ±2 V, > 200 mV to 5 V/div: ± 50V
  • Hardware bandwidth limits: Approximately 20 MHz (selectable)

Horizontal system analog channels

  • Time base range: 2 ns/div to 50 s/div
  • Horizontal resolution: 2.5 ps
  • Time base accuracy: 5 ppm ±5 ppm per year (aging)
  • Time base delay time range:
    • Pre-trigger: Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
    • Post-trigger: 1 s to 500 s
  • Channel-to-channel deskew range: ± 100 ns
  • ∆ Time accuracy (using cursors): ± (time base accuracy* reading) ± (0.0016 * screen width) ± 100 ps

Acquisition modes

  • Normal
  • Peak detect: Capture glitch as narrow as 500 ps at all timebase settings.
  • Averaging: Select from 2,4,8,16, 64... to 65,536
  • High resolution mode: 12 bits of resolution when ≥ 20 μs/div
  • Segmented: Re-arm time= 19 μs (minimum time between trigger events)

Trigger system

  • Trigger modes
    • Normal (triggered): requires trigger event for scope to trigger
    • Auto: triggers automatically in absence of trigger event
    • Single: triggers only once on a trigger event, press [Single] again for scope to find another trigger event, or press [Run] to trigger continuously in either Auto or Normal mode
    • Force: front panel button that forces a trigger
  • Trigger coupling: Coupling selections: AC, DC, noise reject, LF reject and HF reject.
  • Trigger source: Each analog channel, each digital channel (MSO models or DSOX2MSO upgrade, Ext, WaveGen, line)
  • Trigger sensitivity (internal): < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
  • Trigger sensitivity (external): 200 mV (DC to 100 MHz); 350 mV (100 MHz - 200 MHz)
  • External trigger input: Included on all models

Options and Accessories

Part number Kind Price
DSOX2000-001 WaveGen 20 MHz function generator - installed 410 EUR
DSOX2000-010 Memory upgrade - 1 M for 2000 X-series oscilloscopes - installed 161 EUR
DSOX2000-232 RS232/UART Serial Decode and Trigger - installed 401 EUR
DSOX2000-805 Module - LAN/VGA 324 EUR
DSOX2000-806 Module - GPIB 410 EUR
DSOX2000-A6J Certificate of compliance calibration - ANSI Z540, printed 86 EUR
DSOX2000-AB0 Overlay - Traditional Chinese front panel 0 EUR
DSOX2000-AB1 Overlay - Korean front panel 0 EUR
DSOX2000-AB2 Overlay - simplified Chinese front panel 0 EUR
DSOX2000-AB9 Overlay - Portuguese 0 EUR
DSOX2000-ABD Overlay - German 0 EUR
DSOX2000-ABE Overlay - Spanish 0 EUR
DSOX2000-ABF Overlay - French 0 EUR
DSOX2000-ABJ Overlay - Japanese 0 EUR
DSOX2000-ABZ Overlay - Italian 0 EUR
DSOX2000-AKT Overlay - Russian 0 EUR
DSOX2000-AMS CAN and LIN Automotive Serial Decode - installed 401 EUR
DSOX2000-DVM Digital Volt Meter -2.5-digit DVM + 5-digit counter - installed 60 EUR
DSOX2000-EDK Education Kit for DSO X 2000 Series Oscilloscopes - installed 410 EUR
DSOX2000-LMT Limit Mask Testing - installed 246 EUR
DSOX2000-LSS I2C and SPI Low Speed Serial Decode - installed 401 EUR
DSOX2000-PLG Power cord - Continental European, only for EU distributor with multiple power cord standards 0 EUR
DSOX2000-SGM Segmented Memory - installed 246 EUR
DSOX2MASK Mask Limit Testing Application for InfiniiVision 2000 X-Series Oscilloscopes 246 EUR
DSOX2MSO InfiniiVision 2000 X-Series Oscilloscope MSO Upgrades 587 EUR
DSOX2SGM Segmented Memory Acquisition for InfiniiVision 2000 X-Series Oscilloscopes 246 EUR
DSOX2WAVEGEN Built-in Function Generator Option for InfiniiVision 2000 X-Series Oscilloscopes 410 EUR
DSOXDVM Integrated Digital Voltmeter (DVM) Option for InfiniiVision X-Series Oscilloscopes 61 EUR
DSOXEDK Educators Training Kit for InfiniiVision 2000, 3000 and 4000 X-Series Oscilloscopes 410 EUR
DSOXGPIB GPIB connection module for the InfiniiVision 2000 and 3000 X-Series oscilloscope 410 EUR
DSOXLAN LAN/VGA module for the InfiniiVision 2000 and 3000 X-Series Oscilloscope 324 EUR
N2747A Front Panel Cover for the InfiniiVision 2000 and 3000 X-Series oscilloscope 42 EUR
N6456A Rack Mount Kit for the InfiniiVision 2000 and 3000 X-Series oscilloscope 287 EUR
N6457A Soft carrying case and front panel cover for 2000 and 3000 X-Series oscilloscope 123 EUR

Warranty, Calibration & Services

Part Number Kind Price
R-50C-011-3 Assurance Plan - 3 Jahre Agilent Kalibrierung im Servicezentrum 318 EUR
R-50C-011-5 Assurance Plan - 5 Jahre Agilent Kalibrierung im Servicezentrum 599 EUR