blueprint: | |
name: Tado temperature offset | |
description: Ensure the Tado smart valve has the temp of a separate sensor | |
domain: automation | |
input: | |
source_temp_sensor: | |
name: Source Temperature sensor | |
description: This sensor will be used as the source. | |
selector: | |
entity: | |
domain: sensor | |
device_class: temperature | |
target_tado: | |
name: Tado | |
description: The Tado to set the offset on. | |
selector: | |
entity: | |
domain: climate | |
variables: | |
target_tado: !input target_tado | |
source_temp_sensor: !input source_temp_sensor | |
tado_temp: "{{ state_attr(target_tado, 'current_temperature') | float }}" | |
current_offset: "{{ state_attr(target_tado, 'offset_celsius') }}" | |
actual_temp: "{{ states(source_temp_sensor) | float }}" | |
offset: "{{ ( actual_temp - tado_temp ) | round }}" | |
calculated_offset: "{{ ( ( actual_temp - tado_temp ) + current_offset ) | round }}" | |
trigger: | |
- platform: state | |
entity_id: !input target_tado | |
attribute: current_temperature | |
- platform: state | |
entity_id: !input source_temp_sensor | |
condition: | |
- condition: template | |
value_template: "{{ offset != 0 }}" | |
- condition: template | |
value_template: "{{ actual_temp != 0 }}" | |
action: | |
- service: system_log.write | |
data: | |
message: > | |
{{ target_tado }} has temp difference of {{ offset }}. Setting offset to {{ calculated_offset }} | |
level: info | |
logger: blueprints.tado.offset | |
- service: system_log.write | |
data: | |
message: > | |
target: {{ target_tado }} | |
source: {{ source_temp_sensor }} | |
temp difference: {{ offset }} | |
actual_temp: {{ actual_temp }} | |
tado_temp: {{ tado_temp }} | |
current_offset: {{ current_offset }} | |
calculated_offset: {{ calculated_offset }} | |
level: debug | |
logger: blueprints.tado.offset | |
- service: tado.set_climate_temperature_offset | |
data: | |
offset: "{{ calculated_offset }}" | |
entity_id: "{{ target_tado }}" | |
mode: single |
justcop
commented
Mar 26, 2021
via email
Hi! First of all thanks for a great blueprint. I am now using it with an ESP32 temp sensor and it works well but I indeed notice the same, a lot of opening and closing of the valve. And after a day the battery warning pops us, so indeed a significant drain of the battery. @justcop You have updated the script so it prevents the turning on/off of the valve every time offset changes?
I also updated the rounding, addded a decimal. You can see it in the plot. Left side with no decimals, right side with one decimal. So now they are both more alligned. (Blue ESP32 external reader / purple Tado) Will not help with the frequency of opening/closing off course so I hope this gets fixed :)
I suggest you have a look at this script from a different author who has done something similar.
https://github.com/north3221/home-assistant-config
My script is mostly stolen from there but merged with this one
Mine turns on and off less frequently by only triggering when a change would cause the heating to turn from on to off or vice versa and only when I am home and only when the difference is greater than the set tolerance.
I still find the number of changes too frequent, I'd like to edit it to allow for the expectation that if the target temperature is a lot more than the actual temperature it should expect that the thermostat temperature is also going to increase above the actual temperature more significantly, it could therefore increase the offset in larger increments to anticipate this.
The other problem I'm having is that changes in offsets can trigger open window detection. I'd like to temporarily turn this off prior to a change but this isn't possible with the home assistant integration, would need to access the tado api directly.
thanks a lot. I will have a look at that scripts as well.
I would think that if you are geting acces to the tado api then it would probably, if possible, be a lot easier just to have the external temp reader act as the leading temp reader, similar as adding another (70 euro) wireless tado temp unit ?
Unfortunately the api doesn't allow for that, or else none of this would be necessery.
The api has more features than the HA integration but doesn't go as far as that.
HA intergrations are just a shell around apis but as its laborious, they only include the features that the maker of the integration has translated from the API.
Actually, just looked at the API and you can't change open window detection mode from there. I wonder though if you could just read the mode (manual/scheduled etc) prior to the offset change and then reset that afterwards, would that override the open window detection, I think so.
Does anybody have the issue that this does not work when a room as more than one thermostat? The script works fine on one thermostat for me, but for rooms with more than one, the offset is not set.