These are are some notes I put together on butchering the rectangular dishy cable.
FOLLOW THESE GUIDELINES AT YOUR OWN RISK. I TAKE NO RESPONSIBILITY FOR ANY DAMAGE OR INJURY YOU SUSTAIN FROM FOLLOWING OR NOT FOLLOWING THESE GUIDELINES.
In general, if you can get away with using the original 75' cable (or the official 150' long replacement cable), then that is ultimately preferable to doing any of this stuff. If you don't already know why you would want to do this then you definitely shouldn't do it. If you run into trouble, the first thing Starlink Support is going to ask is if the cable between your dishy and router has any modifications, and for good reason.
Despite the connectors being proprietary, the underlying technology connecting the router and the rectangular dishy is gigabit ethernet with non-standard PoE(The orange and green pairs are positive, the blue and brown pairs are negative). The cable itself is plain stranded STP CAT5e, suitable for outdoor use. The router acts as a 48V, 2A PoE power supply, so 96 watts are available at the port the router.
Stick with the original router (and possibly the ethernet port dongle) unless you have a good reason to try something else. You cannot power dishy with a standard PoE injector, but if you are enterprising enough you can rearrange the wires (swap blue/green, terminate as Type-B) going into and out-of a passive 4-pair PoE Injector and get it working with a sufficiently large 48V or 52V DC power supply.
Note that most 48V 2A power supplies on Amazon are insufficient! I recommend this 52V power supply, as I have confirmed that it works and I am using it on my own 200+ft run.
Resistance is the primary limiting factor you will run into. As you increase the length of the cable and add additional terminations/connectors, resistance increases. If the resistance is too high, the voltage at the dishy will (perhaps only occasionally) drop too low, causing it to spuriously reboot or not boot at all.
The exact maximum round-trip power resistance that the cable can have before Dishy's stability suffers isn't immediately clear, but 1.8Ω round-trip (~88 watts available for Dishy) appears to be stable while 2.5Ω round-trip is just barely unstable. (neither value includes the resistance of about 20 extra feet of the original CAT5e that is used in my setup)
If you cannot easily measure resistance, you will need to be as conservative as possible:
- Keep the length of your entire run as short as possible and your connectors as few as possible. Continuous runs are almost always preferable to runs with connectors.
- Use outdoor-rated cable for outdoor runs. If riser cable is all you have, paint it.
- Don't directly bury the cable unless it is rated for direct burial. Otherwise, water intrusion will eventually make your connection unreliable. The original cable is NOT rated for direct burial.
- Use 23AWG (or larger) CAT6/CAT6A cable, which will contribute around 0.03Ω/meter for a continuous run.
- The original cable was only 24AWG, so if you are using 23AWG cable then the less length you use from the original cable the better.
- It would appear that connectors will each contribute ~0.02-0.1Ω to the round-trip resistance, but more research is required.
- Avoid unnecessary use of patch panels, they introduce additional connectors and add resistance.
- 150' is likely the most distance you are going to get without changing your approach (like splitting out the power into larger guage wires, etc), but if you use a specialty low-resistance cable (like this) then you might be able to almost double that with some careful terminations.
- Once you get everything set up, try turning on snow pre-heat mode:
- If you can run a few speed tests in a row without problems, then you are likely golden.
- If your dishy reboots (either immediately or after running a few speed tests), your cable resistance is too high.
For longer runs you may need to use a power supply with a larger voltage. I can confirm that the rectangular dishy works fine on 52V.
With a longer run, proper grounding and surge protection becomes more important. Dishy must be grounded in some way. With the unmodified original cable, that grounding comes from the router. Since we are cutting that wire, we need to make sure that we provide that grounding.
- At least the the first RJ45 termination on the dishy side should be a grounded RJ45 plug.
- Use a high-quality, grounded, PoE-compatable ethernet surge
protector at the termination closest to your dishy.
- If you do this at your "service entrance" (where the wire enters your house), then you won't need a shielded ethernet cable after that point---but you might want it to be shielded to reduce RF interference.
- If you do use a shielded cable after the grounded surge protector, make sure you don't have a continuous ground between your surge protector and your Starlink router---that would create a ground loop, and you don't want that. If there is a ground fault, some of the surge current could go through your shielding!
- Alternatively, you could forgo the surge protector and use shielded cables, connectors, and plugs for the entire run and ensure continuity between the starlink router and dishy (presumably the router has some amount of built-in surge protection).
@torrmundi: I haven't received it yet, it should come early next week. I did also order one of the NF488 testers, possibly a slightly different revision since mine is NF-488 not NF-488S. Mine seems to work better than yours; I've done limited testing and it correctly identifies 802.3af and at, mode A (4 pairs, channel 1) and AB (both channels). It doesn't support 802.3bt and plugged into a bt switch it reports it as 802.3at with "4 pairs". The power rating when used with a PD on the PoE "Out" RJ45 seems credible. I suggest testing the accuracy of the DC out and DC in ports if you have a load tester (not that they are necessarily that accurate ;-). It's certainly a return if that doesn't work. On mine the "loopback" port doesn't seem to work but that might be my managed switches rejecting a loopback connector.
I believe the polarity of the channels is reported by the voltage; plugged into a switch with 802.3af I get a negative voltage but into the 802.3bt capable switch the voltage was positive. It would be much better if the pins were displayed with "+", "-" or " " underneath. I haven't tested with passive injectors yet; I've only had the tester 12 hours.
I'm not surprised that gave "unsupported"; channel 1 is (all) positive and channel 2 negative. I haven't hacked the test leads for StarLink together yet but my default would be to fabricate swapped 36/45 pairs at both sides then I would expect to see the tester report something; the swapping makes the tester see 1,2,4,5(V+) 3,6,7,8(V-) which corresponds to the POE-INJ-1000-WT that I have and 802.3a[ft] modes A and B. BTW Tycon sells these injectors direct for $10 each and currently has 2683 (or so) in stock. Shipping is $6 USPS; cheaper than anything on Amazon.
As for the McCown I couldn't access your links; Google Drive shareable links normally work just fine for me so I think they might be something else (like the thing on the address bar when a shareable link is created?) I did get home and eyeball my own McCown 800-GIGE-POE-APC (i.e. the Cat5e APC version, not the Cat6 APC version). The transformer is a LINK-PP LP6062ANL:
http://www.link-pp.com/?product/201408082292.html
From the datasheet the current rating (for PoE) is "720mA continuous over 4 pairs", further described on the second page as "[e]xceeds 802.3at requirements with up to 720mA DC supply current over 2 or 4 pairs". This is better than the Pulse Electronics H6062NL component which it claims it's a clone of:
https://productfinder.pulseelectronics.com/part/h6062nl
The datasheet for that states, "DC CURRENT/VOLTAGE RATING 350mA MAX @57V (CONTINUOUS)", I assume that is per pair so a total current delivery/return of 700mA for 39W. So this is not an 802.3bt capable part. The maximum using 60V would be under 45W at the PSE (less at the dish of course).
I assume the Tycon parts, despite being so cheap, are using 802.3bt capable transformers; the input is up to 2.25A at 80V which means that can handle 180W at the PSE. I haven't worked out how to pop the Tycon box open yet but I think I will use the McCown for testing since the jumpers allow testing on individual pairs and I have Snow Melt off, then use a Tycon and probably order a couple more for disassembly/testing.